23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 1

DESIGN 38-CPB BULLETIN CAPB-101

CAST
ALUMINUM
PRESSURE
BLOWER

CHICAGO BLOWER CORPORATION


23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 2

The same marque that has identified higher quality,


extremely durable industrial fans for over 50 years is now
cast into a new series of aluminum pressure blowers.

Chicago Blower’s
new series of cast
aluminum pressure
blowers fills the
Chicago castings blend aluminum with “Industrial Quality” has
diverse needs high-strength alloys to create strong, long described Chicago’s
of high pressure corrosion-free housings and wheels rugged construction and
ideal for adverse industrial environ- guarantees exceptional
applications from ments. Aluminum also stands up to performance and reliability.
sub-zero ambients without material Our fan’s most important feature is
combustion air deterioration. Since aluminum is non- the reliability we are able to add to
to fume and dust magnetic and non-toxic, Chicago’s your product. If you are unsure of a
pressure blowers are recommended fan selection for a specific application,
control to food for both electronic and food related your Chicago representative will help
processing. applications. The non-sparking proper- provide recommendations. Chicago
ties qualify Chicago’s pressure blowers Blower offices are located throughout
for AMCA Type B spark resistant rating. North America and around the world.

2
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 3

Blower
size 1000
is available
with five
wheels of
differing
widths and
diameters.

Each of the eight pressure blower wheel can be easily fitted to meet the Chicago’s Wheel
housings can be fitted with multiple new requirement. No wasted motion.
wheel/inlet configurations to match The housing and motor will usually Designs Meet
the volume required for the application. remain unchanged.
Depending on any one size there is up
Your Precise
to 24 combinations available. Chicago’s Design 38 cast aluminum Performance
pressure blowers are offered in eight
With all these possible selections, the sizes from 8" to 18-1/2" in combina-
Requirement with
user gains the efficiency and maintenance- tion with 64 unique wheels, all stocked Direct Drive
free advantages of direct drive with for quick assembly. They produce flows
the performance versatility of belt drive. to 5000 CFM and static pressures to Reliability
Even if performance needs should 20" wg. and have been performance
change in the future, an alternate verified in an AMCA certified lab.

3
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 4

Six- Eight- Back-


bladed bladed ward
radial radial curved
wheel wheel wheel

WHEELS
Chicago offers two basic types of
cast aluminum wheels. Radial blades
are the most commonly used and
provide the best overall performance.
They consist of either six or eight
blades depending on wheel diameter.
Backward curved blades have
inherently different performance
characteristics, are somewhat quieter,
but are not self-cleaning.
Housings
Wheels with tip speeds to 13,000 can be
fpm are cast of 319 aluminum while rotated to
higher speed wheels are 356 alu- all eight
minum and heat treated. All wheels standard
utilize an integral straight bore hub discharge
and are statically and dynamically positions
balanced.
HOUSINGS
Chicago’s Design 38 pressure blower’s flow is reversable for
blowers have housings cast of either clockwise or counterclock-
Quality 319 aluminum. Their unique split wise rotation. In addition, the
Features housing design with both inlet housings are rotatable to eight
and drive side cover plates provide standard discharge positions.
from the more installation and application Bolted construction facilitates field
Quality versatility. changeover and also simplifies
With bolted cover plates, the periodic cleanout.
Company

4
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 5

SHAFT SEAL
A virgin teflon sheet is bolted to the
drive side of the housing. The seal is
designed to reduce airstream leak-
age and contamination through the
blower shaft opening in the housing.

RUGGED MOTOR BASE


A heavy gauge steel pedestal holds
the motor firmly in place. The
flanged and welded construction
provides exceptional rigidly.

Motors from recognized manufac-


turers are factory mounted and
tested at running speed for
vibration and balance.

INLETS/OUTLETS BLOWER ARRANGEMENTS


The basic slip fit inlet is standard on DIRECT DRIVE
Chicago’s pressure blowers and is • Arrangement 4, with c-face flange
cast into the inlet coverplate. and/or foot mounted motor.
Diameters are available from 4" to • Arrangement 4V, vertical mount
10" for convenient fit of ductwork. with c-face flange mounted motor.
The variety of inlet sizes helps fine Includes flanged inlet.
tune performance for direct drive
blowers. BELT DRIVE
• Arrangement 1 includes heavy
The outlet is cast into each housing steel bearing pedestal.
half in 4" to 8" diameters for a slip • Arrangement 9 as above except
fit duct connection. includes motor slide base. Motor
and drives are factory mounted.

5
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 6

OPTIONAL ACCESSORIES

FLANGED INLETS/OUTLETS
Cast aluminum flanges mount to
either inlet or outlet. Inlet flange
holes are on centerline. Outlet
flange holes straddle centerline.
INLET/OUTLET SCREENS
HOUSING DRAIN Spiral welded steel screen with zinc,
To facilitate cleanout, a 1/2" drain clear chromate finish mounts over the
with plug is located in the lowest standard slip fit inlet or outlet. Screens
point of the housing. are strongly recommended for installa-
tions with unducted inlets or outlets.
VIBRATION ISOLATORS
Rubber-In-Shear (RIS) isolators with INLET FILTER
steel mounting plate molded in Efficient inlet filters are available as
are available for vibration sensitive either a disposable paper type or as a
installations. They provide 1/4" static cleanable, reusable wire mesh. The
deflection. cannister has a flanged base for
mounting to a flanged inlet.
SLIDE GATE DAMPERS
Dampers allow manual adjust of
air volume to suit the application.
Housings are cast aluminum with a
galvanized steel gate and screwlock
Half cut-off slide gate
to hold gate firmly in place. Dampers
damper on a Series 1400
are available for inlet or outlet in
blower with bottom
either full cutoff style mounted on
angular up discharge.
the housing, or half cutoff style that
Ductwork not shown.
mounts to ductwork.

6
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 7

PRESSURE BLOWER SELECTION


Blower capacity tables are based on Corrected SP is 1.10 X 2.75" SP = Correct the BHP. Divide 2.46 by the
standard air at 70°F and sea level. 3.025" SP at 70°F and sea level. correction factor (1.10). 2.46 ÷ 1.10 =
For other operating conditions, To simplify, use 3.00"SP. 2.24 BHP at 100°F and 1000' altitude.
correct the required Static Pressure FOR DIRECT DRIVE FOR BELT DRIVE
(SP) before using the rating tables.
Using the Direct Drive Performance Using the Belt Drive Performance
The Brake Horsepower (BHP) is
tables, enter the tables at the tables, one selection for 1000 CFM at
corrected after blower selection
required Static Pressure, 3.00" SP. 3" SP would also be a Model 1400.
has been made.
Reading down the column, find The blower will run at 2470 RPM and
the CFM rating(s) that meet the require 1.45 BHP at 70°F and sea
EXAMPLE: required 1000 CFM. Several level. (Actual RPM and BHP was cal-
Select a pressure blower to han- blowers meet this requirement, culated by interpolating between the
dle 1000 CFM at 2.75" SP, 100°F one of which is a Model 1400 with 1050 and 900 CFM in the tables.)
and at 1000 feet above sea level. a 12-1/4" x 2-7/8" wheel and 6" Correct the BHP. Divide 1.45 by the
Refer to the Temperature/Altitude inlet. The blower will run at 3450 correction factor (1.10). 1.45 ÷ 1.10 =
table. At 1000 feet and 100°F, the RPM and require 2.46 BHP at 70°F 1.32 BHP at 100°F and 1000' altitude.
correction factor is 1.10. and sea level.
NOTE:
When several ratings meet the
Temperature and Altitude Correction requirements, usually the lowest
ALTITUDE (feet) with BAROMETRIC PRESSURE (HG)
AIR brake horsepower requirement
TEMP 0´ 500´ 1000´ 1500´ 2000´ 2500´ 3000´ 3500´
(F°) 29.92 29.38 28.86 28.33 27.82 27.31 26.82 26.32 will provide the most efficient
Correction factors
-15 .79 .81 .82 .84 .85 .87 .88 .90 for temperature (F) and quietest selection.
0 .87 .88 .90 .92 .93 .95 .97 .99 and altitude (above sea
70 1.00 1.02 1.04 1.06 1.08 1.10 1.12 1.14 level); standard air = .075
100 1.06 1.08 1.10 1.12 1.14 1.16 1.18 1.20 lbs.per cubic foot at sea
150 1.15 1.17 1.19 1.22 1.24 1.26 1.28 1.31 level, 29.92” barometric Identical performances can be
200 1.25 1.27 1.29 1.32 1.34 1.36 1.39 1.42 pressure and 70° F achieved by different blower
sizes by varying the wheel
widths and diameters. Often
installation requirements will
Refer to Chicago Blower’s determine the blower size.
Selection program, fan.net,
for performance, fan curves
and sound data. Contact
your local Chicago Blower
sales engineer for software
and assistance.

7
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 8

PERFORMANCE DESIGN 38-CPB CHICAGO BLOWER CORPORATION


Direct Drive
3450
RPM

Performance shown is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the air stream.
Maximum temperature 150°F.

8
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 9

CHICAGO BLOWER CORPORATION DESIGN 38-CPB PERFORMANCE


Direct Drive
3450
RPM

Performance shown is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the air stream.
Maximum temperature 150°F.

9
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 10

PERFORMANCE DESIGN 38-CPB CHICAGO BLOWER CORPORATION


Belt Drive
Inlet O.D. 4” Maximum BHP = 0.016 (RPM / 1000)3
Wheel Diameter 8” Outlet Area 0.072 sq. ft. Tip Speed (FPM) = 2.094 x RPM

800

Inlet O.D. 5” Maximum BHP = 0.016 (RPM / 1000)3


Wheel Diameter 9” Outlet Area 0.072 sq. ft. Tip Speed (FPM) = 2.356 x RPM

900

Inlet O.D. 6” Maximum BHP = 0.043 (RPM / 1000)3


Wheel Diameter 10 5/8” Outlet Area 0.117 sq. ft. Tip Speed (FPM) = 2.782 x RPM

1000

Inlet O.D. 7” Maximum BHP = 0.107 (RPM / 1000)3


Wheel Diameter 12 1/4” Outlet Area 0.173 sq. ft. Tip Speed (FPM) = 3.207 x RPM

1200

Inlet O.D. 7” Maximum BHP = 0.134 (RPM / 1000)3


Wheel Diameter 14” Outlet Area 0.165 sq. ft. Tip Speed (FPM) = 3.665 x RPM

1400

Performance shown is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the air stream.
Power ratings (BHp) do not include drive losses. Maximum temperature 200°F.

10
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 11

CHICAGO BLOWER CORPORATION DESIGN 38-CPB PERFORMANCE


Belt Drive
Inlet O.D. 5” Maximum BHP = 0.257 (RPM / 1000)3
Wheel Diameter 15.5” Outlet Area 0.307 sq. ft. Tip Speed (FPM) = 4.058 x RPM

1500

Inlet O.D. 8” Maximum BHP = 0.333 (RPM / 1000)3


Wheel Diameter 18” Outlet Area 0.150 sq. ft. Tip Speed (FPM) = 4.712 x RPM

1800

Inlet O.D. 10” Maximum BHP = 0.536 (RPM / 1000)3


Wheel Diameter 18.5” Outlet Area 0.287 sq. ft. Tip Speed (FPM) = 4.843 x RPM

1829

Performance shown is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the air stream.
Power ratings (BHp) do not include drive losses. Maximum temperature 200°F.

11
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 12

DESIGN 38-CPB CHICAGO BLOWER CORPORATION

DIMENSIONS
Direct Drive

GENERAL ASSEMBLY DIMENSIONS BLOWER HOUSING DIMENSIONS


MOTOR
MODEL FRAME AA B C D E F G H M N O P R S T DD MD
800 56 4 1 4 9-3/8 3-3/16 2-15/16 12-3/16 14-1/4 4-3/8 1-1/8 4-5/8 5-5/8 6-1/2 4-7/8 1-1/8 4 8-9/16
56 5 1 4-3/8 9-3/8 3-3/8 3-1/8 13-5/16 14-5/8 5-3/4 1-3/16 6-1/8 7-3/8 7-7/8 6-5/8 1 4 10-7/16
900 143T–145T 5 1 4-3/8 11-1/4 4-3/16 3-1/8 13-13/16 16-1/2 5-3/4 1-3/16 6-1/8 7-3/8 7-7/8 6-5/8 4 11-7/8
56 6 1 4-1/2 9-3/8 3-7/16 3-3/16 13-7/16 14-3/4 6-3/4 1 6-7/8 9 9-7/16 7-13/16 5 10-7/16
1000 143T–145T 6 1 4-1/2 11-1/4 4-1/4 3-3/16 13-15/16 16-5/8 6-3/4 1 6-7/8 9 9-7/16 7-13/16 5 11-7/8
56 7 1-3/8 5-3/16 9-3/8 4-1/4 3-15/16 14-11/16 15-13/16 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 11-7/8
1200 143T–145T 7 5-3/16 11-1/4 4-9/16 3-15/16 15 17-11/16 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 11-7/8
182T–184T 7 5-5/16 13-15/16 5 3-15/16 19-3/16 20-3/8 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 11-7/8
56 6, 7, 8 6-5/16 9-3/8 5-1/2 4-1/2 20-1/4 16-15/16 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6 15-3/16
1400 143T–145T 6, 7, 8 6-5/16 11-1/4 5-1/2 4-1/2 20-1/4 18-13/16 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6
182T–184T 6, 7, 8 6-7/16 13-15/16 5-1/2 4-1/2 20-1/4 21-1/2 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6
182T–184T 6, 8, 10 7-5/16 13-15/16 5-15/16 4-15/16 21-1/8 22-3/8 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8
1500 213T–215T 6, 8, 10 7-5/16 15-9/16 6-1/8 4-15/16 21-5/16 24 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8
254T–256T 6, 8, 10 7-5/16 19-19/32 6-1/8 4-15/16 25-9/16 28-1/32 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8
182T–184T 6, 8, 10 6-5/16 13-15/16 5-7/16 4-7/16 20-1/8 21-3/8 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6
1800 213T–215T 6, 8, 10 6-5/16 15-9/16 5-5/8 4-7/16 20-5/16 23 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6
254T–256T 6, 8, 10 6-5/16 19-19/32 5-5/8 4-7/16 24-9/16 27-1/32 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6 15-3/16
182T–184T 8, 10 8-1/8 13-15/16 6-1/2 5-11/32 24-3/32 23-3/16 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 8 18
213T–215T 8, 10 8-1/8 15-9/16 6-1/2 5-11/32 24-3/32 24-13/16 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 8 18
1829 254T–256T 8, 10 8-1/8 19-19/32 6-1/2 5-11/32 29-3/32 28-27/32 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 8 18
284T–286T 8, 10 1-3/8 8-1/8 21-13/16 6-1/2 5-11/32 29-3/32 31-1/16 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 1 8 18

APPROX NOTES:
PEDESTAL DIMENSIONS VERTICAL
SHIP All motors available with C-face flange.
MODEL PA PB PC PH PJ WEIGHT KK MM Shipping weights based on heaviest combination in series.
Dimensions are shown in inches.
800 7 7-1/8 5-1/16 5-1/2 5 20 1-5/16 3-1/4 Do not use for construction unless certified.
7 7-7/8 6-15/16 5-1/2 5-3/4 25 1-5/16 3-7/16 Dimensions shown are for BH discharge only and may vary for other discharges
900 9 8 8-3/8 7-1/2 5 30 1-5/16 3-7/16 Maximum speed is 3600 RPM.
7 7-7/8 6-15/16 5-1/2 5-3/4 32 1-5/16 3-1/2
1000 9 8 8-3/8 7-1/2 5 35 1-5/16 3-1/2
9 8 8-3/8 7-1/2 5 45 1-11/16 4-1/4
1200 9 8 8-3/8 7-1/2 5 45 4-1/4
12 11-3/4 7-3/8 9-7/8 8-3/4 56 4-1/4 DIMENSIONS
1400
12
12
11-3/4
11-3/4
11-11/16
11-11/16
8-3/4
8-3/4
75
75
4-13/16
4-13/16 Vertical Mount
12 11-3/4 10-11/16 8-3/4 75 4-13/16
12 11-3/4 10-11/16 8-3/4 85 5-1/4
1500 12 11-3/4 9-15/16 8-3/4 92 5-1/4
16-1/2 16 8-15/16 13 105 5-1/4
12 11-3/4 10-11/16 8-3/4 90 4-3/4
1800 12 11-3/4 9-15/16 8-3/4 95 4-3/4
16-1/2 16 8-15/16 9-7/8 13 110 4-3/4
16-1/2 13-3/4 13-1/2 12-1/2 10-3/4 130 5-21/32
16-1/2 13-3/4 12-3/4 12-1/2 10-3/4 130 5-21/32
1829 16-1/2 18-3/4 11-3/4 12-1/2 15-3/4 135 5-21/32
16-1/2 18-3/4 11 12-1/2 15-3/4 130 1-11/16 5-21/32

12
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 13

CHICAGO BLOWER CORPORATION DESIGN 38-CPB

DIMENSIONS
Belt Drive

GENERAL ASSEMBLY DIMENSIONS NOTES:


MOTOR Shipping weights (less
MODEL FRAME AA B C D E F G H I ML motor)based on
800 56 4 1 3-15/16 16-1/8 5-3/8 2-15/16 21-1/16 23-3/16 2-1/8 15 heaviest combination
in series.
900 56 5 1 4-5/16 16-1/8 5-13/16 3-1/8 21-7/16 23-9/16 2-1/8 15
56 6 1 4-7/16 16-1/8 5-7/8 3-3/16 21-9/16 23-11/16 2-1/8 15 Unit shown is right side
1000 mount. Left side mount
143T–145T 6 1 4-7/16 16-1/4 5-7/8 3-3/16 21-9/16 24-1/16 2-1/8 15
available.
56 7 1-3/8 5-1/4 16-1/16 6-1/4 3-15/16 22-11/16 24-13/16 2-1/8 15
1200 143T–145T 7 5-1/4 16-1/16 6-1/4 3-15/16 22-11/16 25-3/16 2-1/2 15 (ML) Max. motor length.
182T–184T 7 5-1/4 16-1/16 6-1/4 3-15/16 25-11/16 28-11/16 3 19
Dimensions are shown
56 6, 7, 8 6-3/8 16 6-3/4 4-1/2 23-3/4 25-7/8 2-1/8 19 in inches.
143T–145T 6, 7, 8 6-3/8 16 6-3/4 4-1/2 23-3/4 26-1/4 2-1/2 19
1400 Do not use for
182T–184T 6, 7, 8 6-3/8 19 6-3/4 4-1/2 26-3/4 29-3/4 3 19
213T–215T 6, 7, 8 6-3/8 19 6-3/4 4-1/2 26-3/4 30-3/8 3-5/8 19 construction unless
certified.
182T–184T 6, 8, 10 7-1/4 19 7-3/8 4-15/16 27-5/8 30-5/8 3 19
1500 213T–215T 6, 8, 10 7-1/4 19 7-3/8 4-15/16 27-5/8 31-1/4 3-5/8 19 Dimensions shown are
254T–256T 6, 8, 10 7-1/4 25-1/2 7-3/8 4-15/16 34-1/8 38-3/8 4-1/4 26 for BH discharge only
and may vary for other
182T–184T 6, 8, 10 6-1/4 19-3/16 6-7/8 4-7/16 26-13/16 29-13/16 3 19
discharges.
1800 213T–215T 6, 8, 10 6-1/4 19-3/16 6-7/8 4-7/16 26-13/16 30-7/16 3-5/8 19
254T–256T 6, 8, 10 6-1/4 25-11/16 6-7/8 4-7/16 33-5/16 37-9/16 4-1/4 26 Maximum speed is
182T–184T 8, 10 8-1/16 19-5/32 7-3/4 5-11/32 28-19/32 31-19/32 3 19 3600 RPM.
1829 213T–215T 8, 10 8-1/16 19-5/32 7-3/4 5-11/32 28-19/32 31-7/32 3-5/8 19
254T–256T 8, 10 1-3/8 8-1/16 25-21/32 7-3/4 5-11/32 35-3/32 39-11/32 4-1/4 26

GENERAL ASSEMBLY DIMENSIONS PEDESTAL DIMENSIONS APPROX.


MOTOR SHIP
MODEL FRAME M N O P R S T DD BD CD +/– CD PA PB PH PJ WEIGHT
800 56 4-3/8 1-1/8 4-5/8 5-5/8 6-1/2 4-7/8 1-1/8 4 14 11-1/2 1-1/16 13-3/8 15 11-3/8 10 65
900 56 5-3/4 1-3/16 6-1/8 7-3/8 7-7/8 6-5/8 1 4 14 11-1/2 1-1/16 13-3/8 15 11-3/8 10 70
56 6-3/4 1 6-1/8 9 9-7/16 7-13/16 5 14 11-1/2 1-1/16 13-3/8 15 11-3/8 10 75
1000
143T–145T 6-3/4 1 6-7/8 9 9-7/16 7-13/16 5 14 11-1/2 1-1/16 13-3/8 15 11-3/8 10 80
56 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 14 11-7/8 1-1/32 13-3/8 15 11-3/8 10 95
1200 143T–145T 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 14 11-7/8 1-1/32 13-3/8 15 11-3/8 10 95
182T–184T 7-5/16 7/8 8 9-5/8 10-1/2 9-7/16 6 18 14-1/2 1-7/32 18 18 16 13 125
56 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6 18 11-7/8 1-1/32 18 18 16 13 105
143T–145T 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6 18 11-7/8 1-1/32 18 18 16 13 105
1400
182T–184T 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6 18 14-1/2 1-1/8 18 18 16 13 135
213T–215T 8-1/16 1-1/8 8-11/16 10-1/4 11-5/16 10-1/4 6 18 15-1/4 1-7/32 18 18 16 13 135
182T–184T 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8 18 14-9/16 1-7/32 18 18 16 13 155
1500 213T–215T 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8 18 15-1/4 1-1/4 18 18 16 13 155
254T–256T 8-5/8 1 9-13/16 11-3/8 12-7/8 10-13/16 8 23 17-15/16 1-7/16 19-1/4 24-1/2 17-1/4 19-1/2 200
182T–184T 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6 18 14-15/16 1-1/16 18 18 16 13 165
1800 213T–215T 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6 18 15-5/8 1-1/4 18 18 16 13 165
254T–256T 10-1/2 15/16 10-1/2 12-11/16 13-3/4 11-3/8 6 23 18-15/16 1-7/16 19-1/4 24-1/2 17-1/4 19-1/2 215
182T–184T 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 8 18 14-15/16 1-1/16 18 18 16 13 175
1829 213T–215T 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 8 18 15-5/8 1-3/16 18 18 16 13 180
254T–256T 9-27/32 7/8 11 12-7/8 14-3/32 11-13/16 1 8 23 18-5/16 1-7/16 19-1/4 24-1/2 17-1/4 19-1/2 225

13
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 14

DESIGN 38-CPB CHICAGO BLOWER CORPORATION

DIMENSIONS
Inlet/Outlet Flange

NO. of NOTES:
AA FG * Meets ANSI-125 lb.
or DD FA FB* FC* FD FE HOLES FH flange dimensions.
FA fits over the Inlet
4 4-1/16 9 7-1/2 3-11/16 4-9/16 4 15/16 (AA) or Discharge (DD)
5 5-1/16 11 8-1/2 4-9/16 5-9/16 4 15/16
6 6-1/16 11 9-1/2 5-1/2 6-9/16 4 1-1/16
7 7-1/16 11 9-1/2 6-7/16 7-5/8 8 15/16
8 8-1/16 13-1/2 11-3/4 7-1/2 8-5/8 8 1
10 10-1/16 16 14-1/4 9-11/16 10-9/16 8 1
Dimensions are shown in inches.
Do not use for construction unless certified.

DIMENSIONS
Full Cut-Off Damper

SIZE A B C D E F G H K L WGT.
4 3-7/8 6-3/4 2-1/4 3-1/2 6-3/4 5 4-1/8 1-1/8 3-1/4 5/16 1
5 4-15/16 8-5/8 2-3/4 5 9-1/4 6 5-3/8 1-1/8 4-5/8 3/8 1-3/4
6 5-15/16 10-1/4 3-1/4 5-1/4 10 7-1/4 6-1/2 1-1/2 5-3/8 3/8 2-1/4
7 6-7/8 11-1/4 3-3/4 5-3/4 11-3/4 8 7-1/4 1-1/4 6-3/4 3/8 2-1/2
8 7-15/16 12-5/8 4-1/4 6-3/4 14 9-5/8 8-5/8 1-3/4 7-1/2 7-1/6 3-3/4
10 9-15/16 17-7/8 5-3/4 7-5/8 17 11-3/4 10-1/2 2-1/8 9-1/2 9/16 7-3/4
Dimensions are shown in inches. Do not use for construction unless certified.

14
23902_Design 38-CPB:Design 38/CPB 4/8/08 11:42 AM Page 15

ENGINEERING
SPECIFICATIONS GENERAL:
Provide a high performance, low maintenance, centrifugal fan with radial
Centrifugal CPB Fans wheel. Fan shall be air performance tested based on tests and procedures
in accordance with AMCA 211. Fans must be manufactured and assembled
in the U.S.A.
Acceptable vendors: Chicago Blower Corporation

PERFORMANCE:
Performance shall include steep pressure and overloading horsepower char-
acteristics. Mechanical efficiency shall be no less than 60%. System static
pressure changes of 30% shall result in no more than 10% CFM reduction.

HOUSING:
Housing shall be cast with 319 cast aluminum, having a 3/16" minimum
wall thickness. Housing should consist of two halves which are bolted and
sealed. Inlets and outlets shall be round of nominal diameters for slip fit of
ductwork, flexible connector, or hose. Housings include a Teflon shaft seal.
All housing sizes shall be reversible for clockwise or counterclockwise
and capable of being rotated to all eight standard discharge positions.

WHEEL:
Wheels with tip speeds to 13,000 feet per minute shall be 319 cast
aluminum. Wheels with tip speeds over 13,000 feet per minute shall be
356 cast aluminum with T6 heat treatment. All wheels shall have an inte-
gral straight bore hub keyed with set screws for mounting. Wheels to be
statically and dynamically balanced to G 6.3 standards in accordance with
ISO 1940 and ANSI S2.19 specifications. The addition of weights is not
allowed, thus balancing shall be accomplished by material removal only.

MOUNTING:
Motorbase-Fan shall be mounted with heavy gauge steel pedestal.

FACTORY MOUNTED MOTORS:


Motors to be factory mounted. Unit to be tested at running speed for
vibration and balance. Filtered vibration readings, taken at bearings, not to
exceed .22 inches per second.

ACCESSORIES:
• Flanged Inlet/Outlet – 319 Cast Aluminum with Punched Holes
• 1/2" NPT Housing Drain with Plug
• Inlet/Outlet Screen
• RIS Isolators
• Inlet Filter
• Slide Gate Damper
• Belt Guard
• Shaft and Bearing Guard

15