You are on page 1of 50

LED/LCD TV T-CON & Screen Panel Repair Guide 191

Try to replace the old T-con board EEPROM IC to the new T-con board there,
but still no help.

Finally found that it same as the LG T-con board, it has a special place to
modify their setting through hardware method. That is to change their resistor
position as change their T-con board setting. Refer to photo below:

• Original resistor position (Display Upside Down):


R459, R458, R451, R455, R453

• After changed resistor position (Display back to normal position):


R459, R458, R452, R455, R454

After changed these SMD resistors position, the TV display was back to normal
now.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 192

How to Solve Display Upside Down


Problem in Universal LCD/LED TV
Mainboard

When the TV is complaint upside down (or after replace Universal Mainboard)
problem, if this is a Universal Mainboard, they have two methods to solve this
problem.

1) Make adjustment in Factory Setting

- Some universal mainboard built in a feature call it as “Mirror Mode” or


similar function name feature. So we can go there to adjust their setting
and the display will back to normal position.

For Example:

6M48/6M182/6M30 Series Universal Flat TV Mainboard

# After login in the TV Factory Setting, go to “Panel Adjust” and select


the “6M30”. (Refer to 6M182.21B Universal Mainboard)

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 193

Inside the 6M30 Adjust menu, found the 6M30 “MIRROR MODE”
button. This “MIRROR MODE” has 4 selections: 1,2,3,4. Each control
Upside Down and Left Right reverses. From here you can choose which one
is suit the TV screen position. So the display upside down problem can be
solving it easily.

2) Replace or Upgrade their Universal Mainboard Firmware

- Some of the universal mainboard, one model/part number mainboard, but


it has two types of firmware. One is normal position firmware, another
one is upside down firmware. For example, some of the V59 series
universal mainboard. So if you’re facing the display upside down
problem in universal mainboard but their Factory Setting not provided the
Mirror Mode or similar function to control the display position, then you

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 194

need to find out another same manufacturer and spec firmware, also
confirm that is a upside down firmware. After that programmed or
upgrade the firmware into the Mainboard or their flash memory IC there.

- With this method, you can solve the Universal Mainboard upside down
problem easily. Before that, lots of the TV repairer when they facing
these type of Universal LCD/LED TV Mainboard, they don’t know how
to do it. So they just replaced a whole Mainboard or return back to
customer and said that’s the panel, not worth to repair it. But when you
know how to repairing it, so it will not the problem to repair display
upside down problem in Universal Mainboard.

- If the above method also can’t solve the display upside down problem,
please refer to this ebook Part-3 & 4 of troubleshooting & repairing
display upside down problem. Because some of the T-con board/section
has design a feature to control the display position.

Notes:
If the above TV setting after changed is back to normal display, but after restart
the TV, it’s still same problem like before. Then you need to checking
Mainboard EEPROM, Flash Memory IC and their voltage supply (make sure
that voltages are normal and stable).

Extra Notes:
Some of the Universal Mainboard built in above 10 types of LCD/LED Panel
“Firmware” (not the settings). So this type of Universal Mainboard no need to
programmed their firmware when replace different LCD Panel. Some of them
can use the USB thumb drive to upgrade their firmware without the ISP
Programmer. But if their main firmware corrupted, then you also need to use
ISP Programmer to transfer or copy the firmware from a good mainboard
EEPROM or Flash IC. So the ISP Programmer is a must have tool to repair TV
or other electronic devices.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 195

Display Left Right Reverse Problem Solved


T-con Board: Sharp 4224TP CPWBX RUNTK DUNTK

Panel: Sharp 42 inches Panel

This Sharp LCD Panel has a common fault of display left half and right half
was reversed. Please refer to the photos above. This TV even re-programming
their Mainboard firmware also can’t solve the problem. So confirm the problem
was in the T-con board there. But this part number of T-con board EEPROM
firmware is not available. So it is hard to repair it or maybe need to replace a
new or working T-con board to give it a try.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 196

Fortunately found this model of T-con board (Panel) has a common fault of this
symptom. And the manufacturer also created the solution or service bulletin to
repair this T-con board. The method is easy just solder a wire to shorted the smd
inductor nearby the LVDS connector. Please refer to the photos below. After
that this TV display problem solved!

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 197

White Screen Problem on V315B3-C04


T-con Board
T-con Board: V315B3-C04

Panel Model: V315B3-L04

This T-con board has using in lots of brands and model LCD Tv, for example
Sony, Hisense, Konka and etc.

This LCD Panel V315B3-L04 has a common fault that is “White Screen’
problem. This is because of the V315B3-C04 T-con Q2 (A18E, P-channel MOS)
was shorted. When this LCD Panel with white screen problem measures their
VAAP (or calls it as VDA) is 0V. Power of the TV, using Ohm meter to
measure the VAAP point to GND is about 2 ohm only! That’s mean some of the
VAAP circuit component/s is shorted. After checking VAAP circuit found the
Q2 was short circuit.

Remember! Please don’t direct replace the Q2 and power on the TV. Because it
maybe will short or burn the Q2 or maybe take some time it will come back
again with the same symptom. This is because of their LCD Pane l design bug!
Their Source PCB and above metal shield not put an isolated pad in between

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 198

them. So it will easily Source PCB components touch the metal shield and
shorted T-con board.

So insert a thin plastic pad or any insulated material to isolate the Source PCB
and their above metal shield. Remember to put insulated of both left and right
side Source PCB. After modify, this LCD Panel can last long to use.

Note: This T-con board VAAP to Ground good ohm values is about 26Kohm or
above.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 199

No Display or Grey Screen - Common Fault


on LG 370WX4-SLA1_(6870C-0158A)
Panel: LG 370WX4-SLA1

T-con Board: 6870C-0158A

Symptom: No display or grey screen (no display but backlight lit)

This LG 370WX4-SLA1 has a common fault in its T-con board. The common
fault symptom is No Display or Grey Display (because the backlight is lit).
After checked the T-con board found that VHGM no voltage, but VGH has
about 26V.

Found the U7 IC has VGH voltage input, but their VGHM is no output. After
replaced U7 (RT8901), the TV No Display problem solved.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 200

LG 470WU5-SLA1(6870C-0140B) No
Display Problem Solved
T-con Board: 6870C-0140B

LCD Panel: LC470WU5-SLA1

A 47 inches LCD TV came with complaint no display problem. After power on


the TV, TV sound ok and backlight lit. So suspect the T-con board problem.
After checked the T-con, found their VGH voltage abnormal just about 2V only.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 201

Trace the VGH circuit line and found the SMD R128 (82ohm) was opened
circuit. After replaced this resistor, the Tv can show the display perfectly.
Below is the VGH waveform for this T-con.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 202

AUO T460HB01 V0 (46T12-C01) T-con


Board with Randomly No Display Problem
T-con Board: AUO T460HB01 V0 / 46T12-C01

Tv Model: TCL LE468810 LED TV

This T-con Board has a common fault as randomly no display. Actually this
type of symptom is very hard to troubleshoot. Unless we have all the working
PCB boards use one by one to swap and test. Finally found the problem was
their T-con board defective.

When the TV no display, checking their T-con and found that Q201 pin S
(Source) is about 15.5v. Pin G (Gate) is 13.2v, but the pin D (Drain) is 0v, no
output! After replaced this Q201 with AO3041A on T-con board, this TV is
back to working now.

schematic4you.blogspot.com
http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 203

How to Solve Samsung LCD TV Oil


Painting Display Problem
The customer bought in a LCD TV with the symptom like display oil painting.
You can refer to the photo below:

This LCD TV didn’t have any logo in front of the TV cover and the rear cover
also no any tv manufacturer details or the model too. But the customer said it is
a Samsung LCD TV. After dismantle this LCD TV, their PCBs are use as photo
below:

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 204

This LCD TV is using a Universal LCD/LED TV Mainboard, not the Samsung


mainboard as usual we look inside the Samsung Tv. This mainboard part
number is: VS.T811_V2.1. The photo of this universal mainboard:

This universal mainboard was using in many OEM brands LCD & LED TV.
But this mainboard has a common fault it was the symptom of “Oily Painting
Display” problem or Display Distortion problem on the screen.

Normally this symptom was causing by the TV Panel setting problem. Because
of this universal mainboard(VS.T811_V2.1) can support several model panels
for LCD/LED TV, so it has panel setting inside their Factory Setting.
Use the Universal Mainboard TV remote control and press the “SOURCE”
button, after that press buttons 2, 0, 8 (within 3 seconds) and it will show the
Factory Setting page on the screen.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 205

Choose the “Panel Adjust” button, inside there to select “Ti Map 10 Bit T-=1”.
Exit the factory setting and restart the TV. The TV is back to normal now.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 206

Yes! This Tv is showing the Samsung logo on the screen. This is a clone or
copycat Samsung LCD TV!

This universal mainboard is using in many OEM LCD/LED TV. So you can
learn this method to repair different OEM brands LCD/LED TV now.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 207

Samsung Display Distortion (Oily Painting


Display) Repair Solution

Many Samsung main boards are designed to support multiple models. Each
board comes with a simple set of instructions that will generate a picture. The
Option Bytes are programmable to support different screen sizes, different
feature sets or even different panel types. If a new main PCB is installed the
option bytes must be verified to ensure proper operation.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 208

Option Bytes data can be obtained from the service manual. Each model and
panel type must be matched to ensure proper operation.

These are examples of incorrect option byte settings. The picture on the left not
only shows incorrect picture color but the picture is upside down.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 209

The above display problem need to login to their Option Bytes menu to make an
adjustment there to repair this display problem. Here are the steps to login:

1) Using the customer remote control enter [MENU] + [1]+[8]+[2]+[POWER]

2) Enter into the Option Bytes menu

There are a variety of test patterns that can be used to isolate panel failures from
a Mainboard issue. There are under the FBE or Enhancement sub menu. Here
are the steps to login:

1) Using the customer remote control enter [MENU] + [1]+[8]+[2]+[POWER]

2) Enter into the Option Bytes menu

3) Enter the code listed below:

- 540 series and lower 0000 + Exit

- 550 series and higher 0214 + Exit

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 210

4) Exit the option byte menu, the grayed out option (FBE3 or Enhancement)
should be available now (If the option still isn’t available re enter the code).

5) Scroll down and enter the FBE or Enhancement option.

6) PATT SEL should be the first option

7) Scroll through the test patterns

If these test patterns display without error the problem is not with the Panel or
T-con/FRC boards.

Note: The patterns are not available on some lower end models TV.

T-con Board Failure Modes

If the T-con board failures can be all over the screen or localized. T-con board
failures can cause half the screen to go black of full white. T-con board defects
do not go away with content or connection. If the problem disappears when the
input s changed it is not the T-con board. If the problem completely disappears
with a darker or brighter scene the problem is not the T-con board.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 211

FRC Board Troubleshooting

The FRC board can be tested by accessing the FRC Test Pattern under the
control submenu of the service mode. Both of the FRC patterns are generated on
the FRC Board. If the test patterns are displayed without error the problem is
before the FRC board, either the Mainboard or the video source. Additionally if
the FRC board cannot communicate with the Mainboard the front panel LED
will flash at startup.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 212

How to Solve Display Distortion (Oily


Painting Display) Problem in Universal
LCD/LED TV Mainboard

1) T.VST29.03 / T.VST59S81 Series Universal Mainboard

After login to the Factory Setting menu, go to “Panel Config”. After that, select
the “LVDS MAP” and change its values from 0 ~15 until the screen display
back to normal. After change the LVDS MAP setting and logout Factory
Setting. The TV Display Distortion (Oily Painting Display) problem solved.

2) 6M48/ 6M182/6M30 Series Universal Mainboard

As usual, after login to their Factory Setting, go to select “Panel Adjust” and
then select “LVDS MAP”.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 213

Change the LVDS MAP values from 0~15 through control the remote
controller left & right buttons, until the normal or good display present.
Normally for AUO55LED & AUO65LED using LVDS MAP “0 or 15” is ok.
ChiMei(CMO) 65LED panel is using “9 or 10” is ok. Other brands panel
manufacturer, you can try to check one by one.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 214

3) MST6M18-V2 Universal Mainboard

After successfully login to the Factory Setting, select “Special Set” and select
“LVDS TI MODE”. Press the Left and Right arrow buttons to adjust or change
their setting. If still not help, then go to select their “LVDS Swap Polarity” to
change to 6 Bits, 8 Bits or 10Bits mode till the display back to normal
(Especially the display also has Ghosting problem).

Notes:
If the above TV setting after changed is back to normal display, but after restart
the TV, it’s still same problem like before. Then you need to checking
Mainboard EEPROM, Flash Memory IC and their voltage supply (make sure
that voltages are normal and stable).

How to Repair LCD TV Symptom with


Blue Screen and Vertical Bars
Brand: Hisense TLM-3233D LCD TV
Symptom: No Display but Blue Screen with Two Vertical White Bars

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 215

When power on this lcd tv, the screen show no display but blue screen with two
vertical white bars. The two vertical white bars will flash but no any content
inside. The LCD TV can hear the sound and remote control to change channel
properly. Try other video signals input like AV and PC also same results. Even
try to call out the OSD menu also same problem too.
Since the LCD TV cannot show the OSD menu and the TV got sound and
change channel properly, so that the mainboard is normal. After observation this
lcd tv, found that the problem could be in the T-CON board or LCD panel.
Check LVDS and FPC cables, they are show as normal, then check the T-CON
board voltages. All voltages in T-CON board are ok, so that i will suspect the T-
CON board mainchip (N39) or their memory chip (N31) defective. I got the
junk T-CON board with same part number, but their DC-DC chip was burnt. So
the mainchip and memory IC can be use.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 216

Because of the N39 (CM2681) have many pins and the memory IC N31
(24LC128) only have 8 pins, so that I choose to replace the N31 first. After
replace the N31, I try to power on the TV, and it was show display perfectly!
Since this N31 is a memory IC, does that mean IC itself damage or just the
firmware corrupt and caused this problem happen? To find out this answer, I
use my programmer to copy the working memory IC firmware and write it into
the original memory IC. Do you guess what has happen? Yes, the LCD TV
working perfectly too! So the problem solved and it was causing by the
firmware corrupted.
The T-CON board memory chip or their firmware corrupt also can cause the
screen problem. So that we need to save their firmware and must prepare some
junk boards of T-con board, mainboard and inverter board for future use.

How to Repair the Display Washed Out


Screen Problem
Model: Samsung LA-37A550P1RXXM LCD TV

LCD Panel: T370HW02 V.4

T-Con Board: T370HW02

When power on the tv, the screen is normal. But after about 10 seconds, it
becomes blurring or nearly white screen/washed out. Like the picture below:

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 217

From the previous experience it is the T-con board problem. As usual, first
check their T-con board top 5 voltages and other related voltages:

Vcc input= 11.63V

VGH= 27.01V

VGHC= 25.89V

VGL= -6V

AVDD= 15.61V

Vcom= 6.33V

VGMA_REF= 15.56V

So the above voltages are normal. So next will checking the Gamma section.

*Below is the Gamma Voltage on T-con Board testing result:

No. Marking Code Bad Values Good Values


1. VGMA22 0.362v 0.365v
2. VGMA21 0.419v 0.42v
3. VGMA20 0.544v 0.545v
4. VGMA19 2.903v 2.905v
5. VGMA18 3.574v 3.578v
6. VGMA17 4.37v 4.37v
7. VGMA16 4.84v 4.84v
8. VGMA15 5.06v 5.07v
9. VGMA14 6.31v 6.31v
10. VGMA13 6.6v 6.6v
11. VGMA12 6.64v 6.64v
12. VGMA11 13.75v 7.91v
13. VGMA10 13.78v 7.96v
14. VGMA9 13.84v 8.31v
15. VGMA8 14.23v 9.83v
16. VGMA7 14.27v 10.1v
17. VGMA6 14.36v 10.66v
18. VGMA5 14.98v 11.62v
19. VGMA4 15.5v 12.43v
20. VGMA3 15.54v 15.28v
21. VGMA2 15.54v 15.43v
22. VGMA1 15.55v 15.5v

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 218

From the above table, found the VGMA3~VGMA12 are abnormal. Because it is
not a smooth ascending or descending voltage values for a Gamma voltages.
Suspect their Gamma IC failure. After remove the heat pad and saw that’s a
“popular” Gamma IC, AS-15F (U201)! So highly confident after replace this
Gamma IC, it can cure the white screen problem from this TV.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 219

Why After Replaced the AS15-G IC to


AS15-HG The TV Still Has Problem?
The AS15 series IC is a 15 x Op Amp IC. It is 14 + 1 Op-Amp, 14 Op-Amp is
for the GAMMA use and another one is for VCOM. Some TV repairer said
after replace the AS15-HF to AS15-HG, the TV screen problem not solve or
more serious than before. Sometime after replace the AS15 IC, the TV display
is ok about 20 minutes, then whole screen change to nearly white screen about
3~5 seconds, and then screen back to normal about 5 minutes and then changed
to white screen again. So the screen is non-stop to change like that, and the new
replace AS15 IC can feeling extremely heat. Are the AS15G and AS15HG
compatible? But when change to another batch of AS15 IC, the T-Con board
problem solved!

Actually the AS15F, AS15G, AS15-HF & AS15-HG all are compatible and
equivalent to use! But the problem is lots of the AS15 series IC in the market
now is not in good condition or call is as recon IC. Especially the cheapest price
of AS15 IC, this type of IC mostly has higher chances is not a good IC.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 220

The above picture of AS15-F IC, this batch of IC: 0452A, we found that after
change to this IC, the IC is extremely heat on the T-con. Finally found the
AS15-HG IC batch no: 1032B, after replace AS15-F with this AS15-HG, the
TV display problem solved and the IC temperature is just feeling warm only.
Even the AS15-HG batch no: 1210C also not good to use.

Note:

I have a tip for this AS15 series IC or even the AS19 series also same. When
they replace the equivalent or compatible AS15 IC on the T-con board, if the
finger can feel AS15 IC surface is very hot, but the display is ok, then I will
recommend change another AS15 IC. Because it will cause this T-con board
cannot last long to use. Or the AS15 IC is extremely heat on the IC surface and
their TV display also abnormal, then direct removes it and replaces another one
to try again. So lots of the TV repairer if they facing this problem before,
hopefully they know what can do now and don’t confuse about it again.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 221

How to Easily Remove AS-15F IC without 3


Minutes
Here has a question, how to remove this AS-15F spider IC easily? Because lots
of the repairer facing a problem is hardly to remove this IC even using their
soldering reworks station!

This method you just need to use a utility knife and a normal soldering iron can
easily remove this IC! Yes, within 3 minutes you can do it. But make sure
you’re trying many time before. ☺

Use a small utility knife, put on the top of their IC pins, move the knife with one
way only! Please don’t move the knife two ways, because it will hard to cut the
pins and easy to damage the PCB board circuit line. One side of IC pins just
moves 3~4 times and then next side. The strength and pressure to move the
knife will depend by you to adjust it. After cut out four sides of IC pins, you can
feel that IC can take out from the PCB.

For your information, if the Gamma IC is AF-15HF or AS-15HG type, below or


bottom of the IC has a ground or heat zinc solder on PCB there. So this type of
IC is very hard to remove from PCB if using the rework station or hot air gun.
But with this method it is easily to take out the IC. After cut out four sides of IC
pins, use a flathead screwdriver to take (tilt) out the IC! So it is not a problem to
remove this IC from T-con board.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 222

After removed the IC, use soldering iron, flux, goot wick and alcohol to clean it
up.

When need to solder new IC on the T-con board, first solder one pin of each
side of the IC to make sure IC pins on the right position. After that we can
solder all the IC pins.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 223

Before power on the Tv, please double check the Gamma IC AF-15F on the T-
con board. Is it any pin/s short together or any dirty solder on the pins there or
not? If everything ok, power on the TV. Finally this TV is ok now.

Note:

After replaced the AS-15F IC, if you found that LCD Display show a bit
darkness than a normal display, that’s mean your AS-15F IC not soldering
properly. You also can use the finger to press down a bit of this AS-15F IC, if
the display quality can change a bit, that’s mean the AS-15F not soldering
properly. So you need to re-solder this IC again.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 224

This LCD Panel Display Problem is Beyond


Repair
Do you know which type of display problem is can’t be repair? Here is the
sample of the display problem you can refer:

1) Broken Screen or Screen Crack

Sure the LCD Panel if screen crack is beyond repair. If this is new TV, the TV
manufacturer will not cover in their 2 or 3 years guarantee policy.

2) LCD Panel Liquid Crystal was Leakage Inside

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 225

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 226

Troubleshooting & Repairing Hisense


RSAG7.820.5129 T-CON Board
This T-CON board schematic diagram was included in this ebook. The
RSAG7.820.5129 T-CON board is widely used in these HISENSE TV Model:

HE390GF-B51, HE460HFR-B51, HE500HF-B52 and HE500HFR-B52.

All the above TV is using this T-CON board, but their program/firmware is
different only.

T-CON Board Circuit Structure

http://www.lcdrepairguide.com/tcon-panel/

schematic4you.blogspot.com
LED/LCD TV T-CON & Screen Panel Repair Guide 227

Test Voltage Test Voltage (V) Test Voltage (V)


Point (V) Point Point
1.2V 1.1~1.3 GMA1 15.1~15.4 GMB1 14.5~14.9
1.8V 1.7~1.9 GMA2 13.4~13.7 GMB2 12.4~12.8
3.3V 3.2~3.4 GMA3 11.8~12.1 GMB3 11.7~12.1
1V 0.9~1.1 GMA4 11.4~11.7 GMB4 10.6~11.0
2.5V 2.4 ~2.6 GMA5 10.7~11.0 GMB5 10.3~10.6
VGH 28 ~ 31 GMA6 8.7~9.0 GMB6 9.8~10.2
VGL -9.0~ -10.0 GMA7 7.6~7.9 GMB7 7.4~7.8
VSS -6.0~ -7.0 GMA8 7.0~7.3 GMB8 6.3~6.8
AVDD1 15.5~16.0 GMA9 6.8~7.1 GMB9 4.8~5.2
VDDD1 3.2~3.4 GMA10 4.8~5.1 GMB10 4.4~4.7
VCOM 6.2~6.8 GMA11 4.0~4.3 GMB11 4.0~4.4
GMA12 3.5~3.9 GMB12 2.8~3.2
GMA13 2.0~2.3 GMB13 2.2~2.5
GMA14 0.6~0.9 GMB14 0.3~0.8

Panel Control Signals & Mini-LVDS Timing Chart Waveform


Timing Control Waveform:

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 228

Control Signals DC Voltage Range


Control Signal PCB Marking DC Voltage (V)
STV GSP 0.002 ~ 0.3
TP SOE 0.2 ~ 0.5
DATA - 1.0 ~ 1.5
POL POL 1.2 ~ 1.9
CPV GSC 0.15 ~ 0.5
LC LC 2~3

Critical T-CON Board Output Voltage Values


Test Point Standard Values Voltage
(V) Tolerance
VCC_PANEL 12 ± 1.2V
1.8V 1.8 ± 0.1V
3.3V 3.3 ± 0.15V
AVDDA1 15.8 ± 0.25V
VGH 29 ± 1.0V
VDDD 3.3 ± 0.15V
VGL -5.8 ± 0.5V

RSAG7.820.5129 T-CON Board Module Features

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 229

Module Features Location Testing Point


A. Gamma Generate NN7 GMA1~GMA14\
Circuit GM1~GM14 & (IML7991D) VCOM
VCOM voltage

B. DC-DC Generate 1.0V NN14 1.33V


(MP1484)

C. DC-DC Generate 3.3V NN12 3.3V


(MP1484)

D. NT71790 T-CON IC NN1

E. DDR DDR buffer NN2

F. Level Shifter Gate driving NN19 (RT8922) HC_L1~ HC_L6


signals

I. Flash Memory save T- N24 or NN5


CON firmware (25B40 or F40)

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 230

Introduce Module Features & Their Common Faults in T-CON


1) Module -A => Generate the Gamma & VCOM voltage

Common Fault:

a) White Screen:
Because the VCOM voltage abnormal or NN7 failure.

b) Display compares to normal display more darkness:


One or more of their Gamma voltages is 0V. First check the VDD_OP1 is
it in 15.85 ± 0.2V normal voltage range. If yes, then check the VCOM &
GM1~GM14. If their voltage is 0V, that’s mean the problem is NN7
failure.

c) Left or Right side of the Screen their display darkness.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 231

2) Module-B => 12V convert to 1.0V


This module provides the 1.0V core voltage to T-CON IC.

Common Fault:

a) 1.0V no voltage:
Normally is their NN14 dry solder joint or failure or RN234 & CN144
damage.

b) 1.0V voltage out of their normal tolerance range:


Normally is causing by the CN39 or RN6 failure.

3) Module-C => 12V convert to 3.3 Voltage Module


This module provides the T-CON board 3.3V

Common Fault:

a) No 3.3V:
It could be their NN12 dry solder joint, RN235 & CN102 failure.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 232

b) 3.3V Voltage out of the normal range:


Commonly it’s their CN2 or RN2 failure.

4) Module D & E => Is T-CON IC and DDR buffer IC.

T-CON IC

Common Fault:

a) NN1 dry solder joint


b) IC NN1 & NN2 chip defective

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 233

5) Module-F => GOA Signal Control IC

How to know this IC is working or not?

Use multimeter/voltmeter to measure the LC_L1 point, if the voltage range is in


between 25V and -6V change, that’s mean this IC is working normally. If not,
then this IC is abnormal.

6) Module-H => Panel Voltage Generated Circuit


(VDDD/AVDDA1/VGL)

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 234

Common Fault:
a) VDDD/VDDA/VGL no output voltage. The TV screen is no display
but the backlight is lit:
NN3 IC damage causes the VDDD/VDDA/VGL no output voltage.
Check the NN3 pin-15 & 16 both pins is it short circuit. If yes, that’s
mean the IC NN3 is damage and need to replace.

b) When connect to Panel, the inductor noisy, screen display has


horizontal line interference:
Normally it is the CN212 failure.

7) Module-I => Flash Memory to save the T-CON IC Firmware

Common Fault:

a) Flash memory NN5 failure


Will affect screen no display (but the backlight is lit).

b) NN5 IC lost firmware


Will affect screen no display (but the backlight is lit).

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 235

Other Common Faults in this T-CON Board


1) Dry Soldering Joint or Pins Shorted

Display Symptom Problem Location Failure Reason


Left side screen no XSN3 connector dry
display or abnormal solder joint
display

Right side screen no XSNN4 connector


display or abnormal pins shorted
display

Left side screen NN19 or NN21 dry


abnormal display solder joint

Display Grey Scale NN1 damage


abnormal

schematic4you.blogspot.com

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 236

2) Gate/Source COF Problem (Glass Cell Problem)

This type of screen problem is not repairable, unless you’ve TAB


bonding machine. If their ITO line/s defective inside the screen glass then
this type of problem is beyond repair.

Description Display Symptom


Vertical Line

Horizontal Line

Vertical Block/Bar

Horizontal Block/Bar

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 237

3) GOA Horizontal Lines on the screen

This GOA horizontal line evenly spaced (vertical 6 pixels). The Panel itself
defective or the T-CON board Module-F (NN19 or NN21- RT8922) failure also
can causing this type of screen problem.

Check the IC NN19 or NN21 pins have dry soldering joint or not. If soldering
ok and just replace this IC.

4) The bottom of Screen have some horizontal line/s jumping


When the TV is in PC25 or HDMI mode, the screen bottom display has
horizontal line/s (1 or 2 lines) jumping. But in other TV Mode, the screen
is normal.

This is because of the TV when in high density signals, their LVDS


output signals is not standard type. And causing the T-CON IC output TE
& STV signals time interval is 1.84ms (~1840us), but the original design
is requirement is 147us! Use the oscilloscope to check the STV and TE
signals and found like picture below:

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 238

So the solution to solve this problem is updating the NN5 IC firmware to


the latest version of LCM_T-TP_161240_B007.

5) Display Grey Scale Abnormal

Mostly, this type of screen problem is causing by the T-CON IC,


Especially the production before 1240, their T-CON IC is the common
fault.

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 239

6) After Power On TV, Screen will show the Red, Green & Blue Display
Non-stop Testing Mode

Normally this problem is causing by their TVS (FN2/FN3/FN4/FN5/FN6)


damage. Use the Multimeter testing this TVS, is the ohm values to GND
is lower than 1K ohm, that’s mean this TVS is damage by ESD already.
Need to replace it with a good one. Or you can just remove this damage
TVS and without connect anything, power on the TV. The TV should be
ok now!

7) Display Abnormal in DTV Mode

http://www.lcdrepairguide.com/tcon-panel/
LED/LCD TV T-CON & Screen Panel Repair Guide 240

This problem is causing by the T-CON IC NT71790. Especially the T-


CON Board production batch before 1240.

8) No Display/ Grey Display (Backlight Lit)

a) The PMU circuit abnormal (Module H), NN3 (AAT1133) abnormal


and causing the VDDD/AVDDA1/VGL no output or output abnormal
voltages. Replace NN3 IC.
b) Gamma circuit abnormal (Module-A). If Gamma IC output voltage
abnormal, the output voltage range is about 6.7V~ 7.0V. Replace
Gamma IC (iML7991D).
c) NN1 dry soldering joint inside the bottom of this T-CON IC. Because
of this IC is BGA package type, so we can use the oscilloscope to
check their STV, LC, TP, POL & etc control signals waveform to
confirm the T-CON IC is ok or not. If these signals got output, then
this IC is Ok, if not, then it is T-CON IC failure.

http://www.lcdrepairguide.com/tcon-panel/