Acute — Limited in duration. Examples include but are not limited to:
• Sprains • Incisional pain • Muscle strain
-4- -5-
TU 3000 TENSunits.com TENSunits.com TU 3000
-6- -7-
TU 3000 TENSunits.com TENSunits.com TU 3000
-8- -9-
TU 3000 TENSunits.com TENSunits.com TU 3000
CAUTION WHILE USING THE STIMULATOR • The long-term effects of electrical stimulation are unknown.
• If the stimulator is not functioning properly or you feel discomfort, • Apply stimulation to only normal, intact, clean, dry, and healthy skin.
immediately stop using the device. • TENS is not effective in treating the original source or cause of the pain,
• Do not use for any other purpose except for what it is intended for. including headache.
• Do not insert the electrode plug into any place other than the jack • TENS is not a substitute for pain medications and other
on the main unit. pain management therapies.
• Do not mix Alkaline and Manganese batteries as this will shorten • TENS devices do not cure disease or injuries.
the battery life. • TENS is a symptomatic treatment and, as such, suppresses the sensation
• Do not pull on the electrode cord during treatment. of pain that would otherwise serve as a protective mechanism.
• Do not use the device while wearing electronic devices such as • Effectiveness is highly dependent upon patient selection by a practitioner
watches as this may damage the device. qualified in the management of pain patients.
• Do not use near a cell phone as this may cause the stimulator to malfunction. • You may experience skin irritation or hypersensitivity due to the electrical
stimulation or electrical conductive medium (gel).
• Do not bend or pull the end of the cord.
• If you have suspected or diagnosed heart disease, you should follow
• When pulling out the cord from the device, hold the plug and pull.
precautions recommended by your physician.
• Replace the cord when broken or damaged.
• If you have suspected or diagnosed epilepsy, you should follow precautions
• Do not throw the batteries into a fire. The batteries may explode.
recommended by your physician.
• Dispose of the device, batteries, and components according to applicable
• Use caution if you have a tendency to bleed internally, such as following
legal regulations. Unlawful disposal may cause environmental pollution.
an injury or fracture.
• The size, shape and type of pads may affect the safety and effectiveness
• Consult with your physician prior to using the device after a recent surgical
of electrical stimulation.
procedure, because stimulation may disrupt the healing process.
• The electrical performance characteristics of pads may affect the safety
• Use caution if stimulation is applied over the menstruating or pregnant uterus.
and effectiveness of electrical stimulation.
• Use caution if stimulation is applied over areas of skin that lack
• Using pads that are too small or incorrectly applied, could result in
normal sensation.
discomfort or skin burns.
• Keep unit away from young children. The unit contains small pieces
that may be swallowed. The electrode cord can cause strangulation.
Immediately contact your physician should any of these things occur.
• Use this device only with the leads, electrodes, and accessories
recommended by the manufacturer.
• Keep unit out of the reach of young children.
- 10 - - 11 -
TU 3000 TENSunits.com TENSunits.com TU 3000
6F22
INSTRUCTION MANUAL
www.tensunits.com
- 12 - - 13 -
TU 3000 TENSunits.com TENSunits.com TU 3000
- 14 - - 15 -
TU 3000 TENSunits.com TENSunits.com TU 3000
5. PARAMETER CONTROLS
- 16 - - 17 -
TU 3000 TENSunits.com TENSunits.com TU 3000
1) Keep the battery and the product out of the range of children.
2) Battery may not be dismantled, thrown into fire or short-circuited.
3) Protect battery from excess heat; Take the battery out of the product if the 6.2 Parameter Settings
product is not used for a long period of time. 1. Mode Control
4) Always replace with the same type of battery. Expose the controls by moving the slide panel down. This switch
has 3 positions; B for Burst stimulation, N for Constant Stimulation,
and M for modulation stimulation. Slide the Mode Selector to the
desired position.
- 18 - - 19 -
TU 3000 TENSunits.com TENSunits.com TU 3000
2. Display LED
Each of the display LEDs illuminate and
pulsate according to the frequency set
3. Pulse Width Control
whenever the device is turned on
Adjusts the length of time each electrical signal is applied through the (one LED per channel).
skin. This controls the strength and sensation of the stimulation. If no
NOTE: Due to the limitations of the human eye, the pulsations of
instructions regarding the pulse width were given by your physician or
therapist, set the control to the suggested 70µs – 120μs. the lamp can only be recognized up to a frequency of
approximately 30Hz. At higher frequencies, the lamp will
appear to be constantly on.
4. Timer Control To reduce the current strength or switch the device off, turn the
This switch has 3 positions — 15min., 30min. and C (Continuous). controls counter clockwise to the required intensity or off-position.
Slide the Timer Control to the desired position.
- 20 - - 21 -
TU 3000 TENSunits.com TENSunits.com TU 3000
5. Check/Replace the Battery 6.4 Skin Care Tips
Over time, in order to ensure the functional safety of TENS, changing
To avoid skin irritation, especially if you have sensitive skin, follow
the battery is necessary.
these suggestions:
1. Make sure that both intensity controls are switched to off position.
1. Wash the area of skin where you will be placing the electrodes
2. Move the slide panel down and remove to access the battery
using mild soap and water before applying electrodes and after taking
compartment (Note the polarity indicated on the battery and in
them off. Be sure to rinse soap off thoroughly and dry skin well.
the compartment).
2. Excess hair may be clipped with scissors; do not shave
3. Pull the battery ribbon to remove the battery from the compartment.
stimulation area.
4. Insert the new battery into the compartment (See page 15 for
3. Wipe the area with the skin preparation your clinician has
replacement battery information).
recommended. Let this dry. Apply electrodes as directed.
5. Replace the battery compartment cover and slide up to close.
4. Many skin problems arise from the “pulling stress” from adhesive
patches that are excessively stretched across the skin during
application. To prevent this, apply electrodes from center outward;
avoid stretching over the skin.
5. To minimize “pulling stress”, tape extra lengths of lead wires to the
skin in a loop to prevent tugging on electrodes.
6. When removing electrodes, always remove by pulling in the direction
of hair growth.
7. It may be helpful to rub skin lotion on electrode placement area
when not wearing electrodes.
8. Never apply electrodes over irritated or broken skin.
- 22 - - 23 -
TU 3000 TENSunits.com TENSunits.com TU 3000
Removal
1. Lift at the edge of electrodes and peel; do not pull on the lead wires
CAUTION
because it may damage the electrodes.
2. Place the electrodes on the liner and remove the lead wire by twisting 1. T he life of electrodes may vary by the frequency of washing, skin condition,
and pulling at the same time. and storage state.
2. If the electrodes no longer stick to your skin or the electrodes are broken,
you should replace new electrodes.
3. B efore applying the self-adhesive electrodes, it is recommended to wash
and degrease the skin, and then dry it.
4. D o not turn on the device when the electrodes are not positioned on the body.
5. N ever remove the self-adhesive electrodes from the skin while the device
is still turned on.
6. If replacement electrodes are necessary, use only electrodes that are the
same size (2" x 2") as the electrodes provided with the TU 3000.
7. U se of electrodes that are larger may reduce the effect of the stimulation.
Use of electrodes that are much smaller than the electrodes provided with
7. CLEANING AND STORAGE the TU 3000 may increase the chance of skin irritation or electrode burns
occurring under the electrodes.
7.1 Cleaning the Unit 8. A lways use electrodes that have been cleared for marketing in the
USA by the FDA.
1) Turn unit off and disconnect the lead wires from the unit.
2) Clean the device after use with a soft, slightly moistened cloth
and wipe gently. 7.3 Storing The Electrode Pads and Lead Wires
• Do not use chemicals (like thinner, benzene).
1) Turn the device off and remove the lead wires from the unit.
• Do not let water get into the internal area.
2) Remove the electrodes from your body and disconnect the lead wires
from the electrodes.
Note: T
his device and accessories (including the electrodes) do not
3) Place the electrodes onto the plastic film and then store into the
require sterilization.
sealed package.
4) Wrap the lead wires and store into the sealed package.
7.2 Cleaning the Electrode Pads
1) Turn the power off and remove the lead wires from the electrodes.
2) Wash the electrodes when the adhesive surface becomes dirty and/or 7.4 Storing the Unit
the electrodes are difficult to attach. 1) Place the unit, electrodes, lead wires and manual back into
• To “wash” the pads, place a small drop of water on your clean the carrying case. Store the box in a cool, dry place, -10ºC ~ 55ºC;
fingertip and rub the water across the entire gel part. Place the 10% ~ 90% relative humidity.
adhesive part face up and let it air dry until the water is absorbed 2) Do not keep in places that can be easily reached by children
and has been reconstituted. Do not wipe with a tissue paper or 3) When not in use for a long period, remove the battery before storage.
cloth. If the electrode still does not stick properly, replace them
with new electrodes.
- 24 - - 25 -
TU 3000 TENSunits.com TENSunits.com TU 3000
8. TROUBLESHOOTING
Problem Possible Causes Possible Solution Problem Possible Causes Possible Solution
Are the batteries Charge or replace the Improper electrode place- Reposition the electrodes
The unit cannot exhausted? batteries. Stimulation is ment at least 1-1∕2” apart.
power on ineffective.
Are the batteries installed Insert the batteries Unknown Contact clinician.
correctly? observing polarity.
Re-position the
Electrodes dried out or Replace with new Using the electrodes on the electrodes. If at any time
contaminated electrodes same site every time. you feel pain or discomfort
Stimulation weak stop use immediately.
Electrodes are not securely
or cannot feel any Reconnect the electrodes
attached to the skin. Ensure the electrodes
stimulation The electrodes aren’t stuck
Lead wires Replace with new The skin becomes are stuck securely on
onto the skin properly
Old/worn/damaged lead wires red and/or you feel the skin.
a stabbing pain Clean the electrodes
Intensity is too high Decrease intensity.
according to description
The electrodes are dirty.
Electrodes are too close Reposition the electrodes in this manual or replace
together at least 1-1∕2" apart. with new electrodes.
Replace electrodes with The surface of the electrode Replace with a new
Stimulation is Electrode active area size ones that have an active was scratched. electrode.
uncomfortable is too small. area no less than 25.0cm2
(5cm*5cm). The electrodes come Turn off the device and
off the skin. place the electrodes again.
May not be operating the Output current
Please check the manual The lead wires are Turn off the device and
device according to the stops during
before use disconnected reconnect the lead wires.
manual. therapy
Verify connection is The power of the batteries Charge or replace the
secure. has been exhausted. batteries.
- 26 - - 27 -
TU 3000 TENSunits.com TENSunits.com TU 3000
- 28 - - 29 -
TU 3000 TENSunits.com TENSunits.com TU 3000
Guidance and manufacturer’s declaration — electromagnetic emissions Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
The device is intended for use in the electromagnetic environment The device is intended for use in the electromagnetic environment
specified below. The customer or the user should assure that it is used specified below. The customer or the user should assure that it is used
in such an environment. in such an environment.
Electromagnetic Environment Electromagnetic
Emissions Test Compliance EC 60601 Compliance
— Guidance Immunity Test Environment
Test Level Level
— Guidance
The device uses RF energy only for
its internal function. Therefore, its Floors should be wood,
RF emissions
Group 1 RF emissions are very low and are concrete or ceramic tile.
CISPR 11 Electrostatic
not likely to cause any interference ±6 kV contact ±6 kV contact If floors are covered with
discharge (ESD)
in nearby electronic equipment. ±8 kV air ±8 kV air synthetic material, the
lEC 61000-4-2
relative humidity should
RF emissions
Class B be at least 30 %.
CISPR11
The device is suitable for use in all
Electrical fast
Harmonic establishments including domestic
transient/ burst Not applicable Not applicable Not applicable
emissions lEC Not applicable and those directly connected to the
IEC 61000-4-4
61000-3-2 public low-voltage power supply
network that supplies buildings used Surge IEC
Voltage fluctuations Not applicable Not applicable Not applicable
for domestic purposes. 61000-4-5
/ flicker emissions Not applicable
lEC 61000-3-3 Voltage dips,
short
interruptions and
voltage varia- Not applicable Not applicable Not applicable
tions on power
supply IEC
61000-4- 11
Power frequency
Power frequency magnetic fields should
(50/ 60 Hz) mag- be at levels characteristic
3 A/m 3 A/m
netic field IEC of a typical location in
61000-4-8 a typical commercial or
hospital environment.
- 30 - - 31 -
TU 3000 TENSunits.com TENSunits.com TU 3000
- 32 - - 33 -
TU 3000 TENSunits.com TENSunits.com TU 3000
Note: E
MC tests conducted including attached electrode cord
of 1.5 m length.
- 34 - - 35 -
Distributed by:
TENSunits.com
12399 S. Belcher Rd., Ste 160
Largo, FL 33773
Ph: 866-237-4013
www.tensunits.com
42-DI3088_00 ©2015
Printed in China