Professional Documents
Culture Documents
02
Replaces: 02.99
Series 1X
H/D 20489/98
Type VT 11118-1X
Table of contents
VT 11118 – 1X / *
Amplifier module for direct operated proportional direc- Further details in clear text
tional valves (type 4WRA, series 1X only), pilot operated
proportional directional valves (type .WRZ, from series 5X) and
proportional pressure reducing valves (type 3DREP 6)
Series 10 to 19 = 1X
(10 to 19: unchanged technical data and pin assignment)
© 2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.
3,5 A 4 7 9 10
power Solenoid
1 + 7,5 V U 7 “a“
1 >I
+ UB I
Operating + DC 8
– 7,5 V S
1000 µF
voltage DC M0
2
0V –1
9 10 Solenoid
∑ U 9 “b“
3 I
5 10
t
Differential input: 2
4 I
Comm. value ± 10 V u 8 U
5 –1 11
Reference potential u 6
GW2 11
>I
12 12
GW1
3 H1
Enable 1 13
6 H2
Enable 2
1 Power supply unit 7 Short-circuit detector GW1 Setting of command value call-up 1
2 Differential amplifier 8 Clock-pulse generator GW2 Setting of command value call-up 2
3 Ramp generator 9 Current regulator
t Ramp time setting
4 Step function generator 10 Output stage
5 Summator 11 Solenoid current measurement S Jump height at Ucomm = ± 10 V
6 Command value change- 12 Overcurrent detector H1 Indicator of command value call-up 1
over and output stage enable 13 Valve type selector switch H2 Indicator of command value call-up 2
Switch positions 1 and 2 for valve types 4WRA (series 1X), Switch position 3 for valve types .WRZ (series 5X and 6X)
.WRZ (series 7X) and 3DREP 6 (series 2X) and 3DREP 6 (series 1X)
Output current in mA →
600
1000
400
500
200
– 10 –5 0 +5 + 10 – 10 –5 0 +5 + 10
← Command value voltage in V → ← Command value voltage in V →
+ UB 1 7
Operating
voltage Solenoid a
0V 2 8
Enable 1 + UF1 3 9
Solenoid b
± Ucomm 4 10
Differenti-
al input Reference 5 11 n.c. 1)
potential 1) These terminals must not
Enable 2 + UF2 6 12 n.c. 1) be used!
7 8 9 10 11 12 Potentiometers:
“Gw1“ → Imax at enable voltage UF1 > 10 V
REXROTH “Gw2“ → Imax at enable voltage UF2 > 10 V
VT 11118
“S“ → jump height
H1
power
“t“ → ramp time
Gw1
79
H2 LED lamps:
1
2
Gw2 “power“ → operating voltage ON
3 S “H1“ → enable voltage UF1 > 10 V
t
“H2“ → enable voltage UF2 > 10 V
1 2 3 4 5 6 Switch positions:
“1“ → for valves 4WRA6 (series 1X),
85,5 40 .WRZ (series 7X) and 3DREP 6 (series 2X)
“2“ → for valves 4WRA10 (series 1X)
“3“ → for valves .WRZ (series 5X and 6X) and
3DREP 6 (series 1X)
– The amplifier module may only be wired when disconnected from the power supply!
– Ensure a sufficient distance to radio sources (>> 1 m)!
– Shield solenoid cables, never lay solenoid cables near power cables;
shield solenoid cables in pairs!
– Do not use free-wheeling diodes in solenoid cables!
– In the case of heavy fluctuations in the operating voltage, it may be required to use an external smoothing capacitor having a
capacitance of at least 2200 µF.
Recommended: Capacitor module VT 11 073 (see RE 29 750); sufficient for up to 3 amplifier modules
Bosch Rexroth AG Bosch Rexroth Limited The data specified above only serves to describe
Industrial Hydraulics the product. No statements concerning a certain
D-97813 Lohr am Main Cromwell Road, St Neots, condition or suitability for a certain application can
Zum Eisengießer 1 • D-97816 Lohr am Main Cambs, PE19 2ES be derived from our information. The details stated
Telefon 0 93 52 / 18-0 Tel: 0 14 80/22 32 56 do not release you from the responsibility for
Telefax 0 93 52 / 18-23 58 • Telex 6 89 418-0 Fax: 0 14 80/21 90 52 carrying out your own assessment and verification.
eMail documentation@boschrexroth.de E-mail: info@boschrexroth.co.uk It must be remembered that our products are
Internet www.boschrexroth.de subject to a natural process of wear and ageing.