GENERAL NOTES: CONCRETE WORK: STRUCTURAL TIMBER:

T.1 THE TYPE, QUALITY, PLACEMENT & FIXING OF ALL STRUCTURAL TIMBER SHALL
C.1 ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH AS 3600 & AS 2870 COMPLY WITH THE REQUIREMENTS OF AS1720 OR AS1684 WHERE
G.1 THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL
C.2. CONCRETE QUALITY SHALL BE AS TABULATED BELOW U.N.O AND SHALL BE VERIFIED BY APPROPRIATE.
AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH
TEST. T.2 ALL TIMBER MEMBERS INCLUDING STRAP OR PLY BRACINGS SHALL BE
OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF
SELECTED IN ACCORDANCE WITH THE ABOVE CODES.
THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE
T.3 ALL SCREWS AND BOLTS TO BE GALVANIZED AND FIXED IN ACCORDANCE WITH
ARCHITECT/ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK.
AS 1720.
G.2 DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE STRUCTURAL
MAX SIZE T.4 ALL TIMBER TO BE MINIMUM STRESS GRADE F7 U.N.O.
DRAWINGS. SLUMP CEMENT EXPOSURE CONCRETE COVER
ELEMENT AGG. T.5 TIMBER JOINTS SHALL BE FREE OF DEFECTS.
G.3 SETTING OUT DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY (mm) TYPE CLASS. GRADE (mm)
(mm) T.6 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE DURING
THE BUILDER.
CONSTRUCTION THAT THE TIMBER IS PROTECTED FROM WEATHER AND THAT
G.4 DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE
THE STRENGTH IS NOT IMPAIRED IN ANY WAY.
CONDITION AND NO PART SHALL BE OVERSTRESSED.
T.7 ROOF TRUSSES ARE TO BE DESIGNED IN ACCORDANCE WITH AS 1720.
G.5 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE SLABS ON 40 TOP T.8 THE TRUSS DESIGNER SHALL PROVIDE CERTIFIED DETAILS OF ALL PLATES AND
REQUIREMENTS OF THE CURRENT EDITIONS OF THE AS CODES AND THE 100 20 A A2 N32
BY-LAWS AND ORDINANCES OMA MA GRADE 45 EXT. CLEATS TO BE ATTACHED TO STEEL WORK TO SUPPORT ROOF TRUSSES, AS
PER MANUFACTURES SPECIFICATION.
G.6 THE STRUCTURAL ELEMENTS SHOWN ON THE DRAWINGS HAVE BEEN
DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:
FOOTINGS & T.9 ROOF TRUSS DEFLECTION IS TO BE LIMITED TO SPAN/600 UNDER LONG TERM
100 20 A A2 N32 65 DEAD LOAD U.N.O.
CONCRETE - AS 3600 PIERS T.10 ROOF TRUSSES TO BE SPACED AT MAXIMUM 600 CENTERS U.N.O.
FOOTING - AS 2870
SUSPENDED 30 TOP T.11 FOR ALL ROOFING, INSULATION AND CEILING DETAILS REFER TO
STEEL - AS 4100 & AS 4600
80 20 A A2 N32 ARCHITECTURAL DRAWINGS.
SLAB 30 BTM
LINTEL SCHEDULE
FOUNDATIONS AND FOOTINGS:
C.3 ALL CONCRETE SHALL BE PLACED AND CURED IN ACCORDANCE WITH AS 3600 WHERE CURING
F.1 FOOTINGS HAVE BEEN DESIGNED FOR AN ASSUMED BEARING PRESSURE OF SPAN (mm) DESCRIPTION END BEARING
COMPOUNDS ARE USED IT MUST BE APPLIED AS FOLLOWS;
100kPa. BUILDER TO CONFIRM BEFORE PROCEEDING WITH CONCRETE POUR.
F.2 ASBESTOS HAS BEEN IDENTIFIED AT SITE AS PER CLIENT BRIEF. BUILDER TO
A) ONTO SLAB WITHIN 2HRS OF FINISHING OPERATION. 0- 900 75x10mm PLATE 100mm
B) ONTO WALLS AND COLUMNS IMMEDIATELY AFTER REMOVAL OF FORMWORK. 900-1050 100x10mm PLATE 100mm
ASSESS THE SOIL CONTAMINATION AND SEEK QUALIFIED OPINION AND
C.4 SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FORMWORK.
APPROVAL IF NEEDED. 1050-1200 90x90x6 EA 100mm
C.5 CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE TO THE APPROVAL OF THE ENGINEER.
F.3 FOOTINGS SHALL BE PLACED CENTRALLY UNDER WALLS AND COLUMNS UNLESS
C.6 BEAM DEPTH ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS. IF ANY. 1200-1500 90X90X8 EA 100mm
OTHERWISE NOTED.
C.7 HORIZONTAL FORMWORK SHALL BE STRIPPED WHEN APPROVED OF BY THE ENGINEER. 1500-1800 100X100X8 EA 150mm
F.4 ALL WORKMANSHIP & MATERIALS SHALL BE IN ACCORDANCE WITH AS 2870.
C.8 UNLESS NOTED OTHERWISE NO ALLOWANCE HAS BEEN MADE FOR STACKED MATERIALS OR
F.5 FILL USED IN CONSTRUCTION OF A SLAB EXCEPT WHERE THE SLAB IS 1800-2400 150X90X8 UA 150mm
MACHINERY ON THE CONCRETE STRUCTURE.
SUSPENDED SHALL CONSIST OF A CONTROLLED FILL OR ROLLED FILL IN
C.9 NO HOLES OR CHASES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE 2400-3000 150X90X10 UA 150mm
ACCORDANCE WITH AS 2870
MADE IN CONCRETE ELEMENTS WITHOUT THE PRIOR APPROVAL OF THE ENGINEER. 3000-3700 150X90X12 UA 150mm
A) ROLLED FILL CONSISTS OF MATERIAL COMPACTED IN LAYERS BY REPEATED
C.10 REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY.
ROLLING WITH AN EXCAVATOR. ROLLED FILL SHALL NOT EXCEED 600mm 3700-5900 250 PFC + 12mm PLATE 150mm
C.11 SPLICES IN REINFORCEMENT MADE IN POSITIONS OTHER THAN SHOWN SHALL BE TO THE
COMPACTED IN LAYERS NOT MORE THAN 300mm FOR SAND MATERIAL OR
APPROVAL OF THE ENGINEER. WHERE THE LAP LENGTH IS NOT SHOWN IT SHALL BE SUFFICIENT WELDED TO BTM FLANGE
400mm COMPACTED IN LAYERS NOT MORE THAN 150mm FOR OTHER MATERIAL.
TO DEVELOP THE FULL STRENGTH OF THE REINFORCEMENT. OR EQUIVALENT GALINTEL
B) CONTROLLED FILL SHALL CONSIST OF WELL GRADED SAND FILL UP TO 800mm
C.12 WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS SHOWN ON THE STRUCTURAL
DEEP WELL COMPACTED IN NOT MORE THAN 300mm LAYERS BY VIBRATING
DRAWINGS.
PLATE OR VIBRATING ROLLER. NON SAND FILL UP TO 400mm DEEP, WELL NOTES:
C.13 PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER TO REINFORCEMENT
COMPACTED IN NOT MORE THAN 150 LAYERS BY A MECHANICAL ROLLER. CLAY 1. SET ANGLES WITH LONG LEG VERTICAL.
WITHOUT THE APPROVAL OF THE ENGINEER.
FILL SHOULD BE MOIST DURING COMPACTION. FOR COMPACTED DEPTHS 2. LINTELS EXCEPT FOR INTERNAL WALLS TO BE HOT DIPPED GALVANIZED.
C.14 ALL REINFORCING BARS SHALL COMPLY WITH AS 4671 ALL FABRIC SHALL COMPLY WITH
GREATER THAN THAT GIVEN ABOVE THE FILL SHALL BE SUBJECT TO CONTROL
AS 4671 AND SHALL BE SUPPLIED IN FLAT SHEETS.
AND TESTING. IF TEST FAILS THEN PIERS ARE REQUIRED. CONTACT THIS OFFICE
PRIOR TO FURTHER CONSTRUCTION.
C.15 REINFORCING SYMBOLS: STRUCTURAL STEEL:
N - DENOTES GRADE D500 HIGH STRENGTH DEFORMED BARS TO AS 4671. S.1 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH
F.6 EDGE BEAMS MAY BE FOUNDED ON CONTROLLED FILL. EDGE BEAMS SHALL NOT
R - DENOTES GRADE R250 HOT ROLLED PLAIN BARS TO AS 4671. AS 4100 EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.
BE FOUNDED ON ROLLED FILL.
SL - DENOTES HARD-DRAWN WIRE SQUARE REINFORCEMENT FABRIC TO AS 4671. S.2 UNLESS OTHERWISE NOTED, ALL STEEL SHALL BE IN ACCORDANCE WITH:
F.7 TOP SOIL CONTAINING GRASS ROOTS OR OTHER ORGANIC MATERIAL SHALL BE
RL - DENOTES HARD-DRAWN WIRE RECTANGULAR REINFORCING FABRIC TO AS 4671. AS 3679.1 GRADE 300 FOR ROLLED SECTIONS.
REMOVED FROM THE AREA ON WHICH THE SLAB IS TO REST.
THE NUMBER IMMEDIATELY FOLLOWING THESE SYMBOLS IS THE BAR DIAMETER IN MILLIMETER AS 1163 GRADE 350 FOR RHS SECTIONS.
F.8 IF ANY FOOTING IS LOCATED SUCH THAT A LINE DRAWN AT 45 DEGREES FOR
C.16 FABRIC REINFORCEMENT TO BE LAPPED ONE MESH PLUS 30mm. LAPS IN POSITIONS OF MAXIMUM AS 1163 GRADE 350 FOR CHS SECTIONS.
CLAY AND 30 DEGREES FOR SAND FROM ITS BASE INTERSECTS A SERVICE
MOMENT ARE NOT PERMITTED. AS 3378 GRADE 350 FOR ALL PLATE.
TRENCH THE PIERS ARE REQUIRED AS PER DETAIL BELOW.
C.17 ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON INSULATED STEEL. PLASTIC OR AS 3679.1 GRADE 350 FOR ALL FLAT.
CONCRETE CHAIRS GENERALLY AT NOT GREATER THAN 800 CENTERS BOTH WAYS. RODS SHALL AS 1397 GRADE 450 FOR 1.5, 1.9, 2.4 AND 3.0 BMT OF COLD-FORMED STEEL
450 DIA CONCRETE PIERS BE TIED AT ALTERNATE INTERSECTIONS. SECTIONS.
FOUND BELOW LINE OF C.18 ALL TENSILE REINFORCEMENT TO BE LAPPED AS SHOWN (u.n.o) S.3 UNLESS NOTED OTHERWISE ALL WELDS SHALL BE 6mm CONTINUOUS FILLET
ZONE OF INFLUENCE WELDS AND ALL GUSSET PLATES SHALL BE 10mm THICK.
INTO NATURAL GROUND S.4 BUTT WELDS WHERE INDICATED IN THE DRAWINGS ARE TO BE COMPLETE
PENETRATION BUTT WELDS AS DEFINED IN AS 1554.
CL REINFORCED BAR N12 N16 N20 N24
S.5 UNLESS OTHERWISE SHOWN ALL BOLTS SHALL BE 16 DIA HIGH STRENGTH (H.S.)
BOLTS SHALL CONFORM TO AS 1252 AND SHALL BE INSTALLED IN ACCORDANCE
LAP LENGTH (mm) 500 600 700 800 WITH AS 4100 AS DIRECTED BY THE ENGINEER.
S.6 UNLESS NOTED OTHERWISE ALL BEAMS TO BE SUPPORTED ON BRICKWORK /
SERVICE ENGAGED BRICK PIERS PLACE INCOMPRESSIBLE PACKING AS REQUIRED UNDER
TRENCH THE ENDS OF THE BEAM TO ENSURE EVEN BEARING ON BRICKWORK. ALL
AY
CL STEELWORK IN CONTACT WITH EXTERNAL BRICKWORK TO BE HOT DIPPED
R GALVANIZED TO SPECIFICATION.
FO ND
45 SA
F OR
30

SERVICE TRENCH DETAIL NOT FOR CONSTRUCTION


NOT TO SCALE

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DESCRIPTION DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 NA
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
GENERAL NOTES CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S1 0