You are on page 1of 9

8 7 6 5 4 3 2 1

H H

IOT HUB

G G
OPC UA Gateway
Web Portal
https://github.com/Azure/iot-gateway-opc-ua
Deployment
Development

F F

56eATM-OPC UA
OPC UA
Server
E OPC UA Configure E
Mobile App
Server
Development
Configure OPC UA
Server
Configure
Configure
D OPC UA D
Server
OPC
UA
Server

IOT
C Configure Gateway C

OPC UA
Server

GAA-DX-145111:dataFEED uaGate SI:


B Gateway OPC UA and MQQT B

Configure

IIOT Solution 1

Using PLC with OPC UA Server and Microsoft Azure


A Cloud Services
A
SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 1 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

IOT HUB

G G

MQTT BROKER SERVICE


Development

F F

MQTT OPC UA
Client Server + IOT
Gateway
MQTT
Broker IOT Mqtt
E Gateway
Configure Mobile App E
MQTT
PROFIBUS®,
Client
PROFINET® or Development
EtherNet/IP™
Mqtt
Mobile App
D D
Development

IOT
Gateway
Configure
C C

MQTT Client

GAA-DX-145111:dataFEED uaGate SI:


B Gateway OPC UA and MQQT B

Configure

AZURE IIOT Solution 2

Using PLC and MQTT Gateway and Microsoft Azure


A A
MQTT Design :Nebojša Lazarević SIZE
A4
FSCM NO
Cloud Services
DWG NO
IIOT – 001 - 2017
REV
1
SCALE SHEET 2 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

vCloud Suite
H PUBLIC CLOUD SERVICE
H
Design
PRIVATE / LOCAL CLOUD SERVICE
MQTT BROKER Deployment
MQTT BROKER
And
Development

G G

Mqtt Mqtt
Mobile App Mobile App

F Development F

MQTT OPC UA
MQTT
Client Server + IOT
Client
Gateway
Configure
E MQTT Configure E
IOT
Broker
Gateway
PROFIBUS®,
PROFINET® or
Configure EtherNet/IP™
Mqtt
Mobile App
D D
Development

IOT
Gateway
Configure
C C

MQTT Client

GAA-DX-145111:dataFEED uaGate SI:


Gateway OPC UA and MQQT
B B
Configure

IIOT Solution 3

A MQTT Using PLC with MQTT gateway and Standard Cloud


MQTT Broker
A
SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 3 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

G G

F F

E E

D D

C C

B B

IIOT Solution 4

Using TwinCAT on Beckhoff PLC platform and Beckhoff


A Cloud Services
A
SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 4 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

AnyViz Portal

G Configuration
G
And Design

AnyViz Protocol
F F

AnyViz - PLC Connection (CODESYS)


https://www.youtube.com/watch?v=E1DGNyQqfN4
App
Development
E E

D D

C C

B B

IIOT Solution 5

Using CODESYS SoftPLC on brandname industrial PC


A platform and AnyViz Cloud Adapter
A
SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 5 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
https://www.com-tom.de

H H

G G

F F

E E

D D

C C

B B

IIOT Solution 6

A Using Beck IPC com.tom solution A


SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 6 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

http://www.osisoft.com/pi-system/

H H

G G

F F

E E

D D

C C

B B

IIOT Solution 7

A Using Standard PC and OsiSoft PI solution A


SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 7 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

G G

F F

E E

D D

C C

B B

IIOT Solution 8

A Using Standard PC and COPADATA solution A


SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 8 OF 9
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

G G

F F

E E
This system architecture satisfies all the requirements of connected manufacturing:

Control level: At the control level, response times and sampling resolution in the sub-millisecond
range allow you to do things like sense mechanical vibrations with extremely high precision. Data at
this level is stored only temporarily, with volumes in the kilobyte or megabyte range.
D Local APROL: Data is preprocessed and stored in the local APROL system for intermediate archiving. D
"Here, you have access to the data for hours, days or months," explains Reichinger. Depending on
computing power and storage capacity, the data can have a time resolution in the microsecond range.
"That allows us to mine real-time data directly in the local APROL system."
Cloud APROL: For long-term archiving and data mining on a larger time scale, data is aggregated in
the cloud, where it can be stored indefinitely and the storage volume is virtually unlimited. "In the
cloud you're looking at a time resolution in range of minutes or even hours," says Reichinger. "That
C explains why it's still not a good idea to move control tasks into the cloud. Today's standard solutions C
don't yet ensure the necessary response times and availability."

B B

IIOT Solution 9

A Using Standard PC and B&R APROL solution A


SIZE FSCM NO DWG NO REV
Design :Nebojša Lazarević
A4 IIOT – 001 - 2017 1
SCALE SHEET 9 OF 9
8 7 6 5 4 3 2 1

You might also like