Professional Documents
Culture Documents
Made Easy
Product at a Glance
Eurotherm by Schneider Electric piccolo™ controllers offer precision • Precision PID control
PID control of temperature and other processes with many advanced • Easy to use and apply
features not normally found in this class of controllers. • High reliability and quality
• Three year warranty
Designed to offer outstanding performance in an affordable package
providing a complete solution for a wide variety of applications, this • Ramp-soak timer and soft start
Ideal for:
• Precision PID controller • Furnaces and ovens
• Plastics extrusion • Incubators
• Food and beverage • Laboratory equipment
Piccolo Controller Data Sheet eurotherm.com/piccolo-controller 2
Power Requirements
Recovery Point Undo Function
P116: 100 to 230 ±15%,
A new feature is provided in the piccolo controller, named RECOVERY POINT. 48 to 62 Hz, max 6 W
Through this feature the user can create a snapshot of the current instrument 24 V AC, –15%, +10%
24V DC, –15% +20% ±5% ripple voltage
settings (operative and configuration parameters). These values can be max 6 W
subsequently restored to reverse changes made during use. P108 and P104: 100 to 230 ±15%,
48 to 62 Hz, max 8 W
Values in the Recovery Point table are modified by an authorized operator 24V AC, –15%, +10%
saving a working configuration through front panel or through PC based 24V DC –15% +20% ±5% ripple voltage
max 8 W
configuration tools. Transmitter PSU (not P116)
Rating: 24 V DC, >28 mA, <33 mA
Configuration Adaptor Isolation: 264V ac double insulated
iTools configuration to piccolo controllers can be achieved by using a
configuration adaptor. It provides iTools with the ability to communicate with Communications
and configure devices without the need for any power being connected. Serial Communications Option
Protocol: Modbus RTU slave
iTools Wizard Modbus RTU Master broadcast
(1 parameter)
Used to simplify the set up of piccolo controllers. The wizard guides the Isolation: 264 V AC, double insulated
user through the configuration process with interactive help and graphical Transmission standard: EIA485 (2 wire)
demonstrations of features.
Piccolo Controller Data Sheet eurotherm.com/piccolo-controller 3
Digital Input (DigIn 1/2, 2 not on P116) Modes Dwell when setpoint reached
Delayed control action, Soft start limits
Contact closure: Open >600 Ω power below PV threshold
Closed <300 Ω
Input current: <13 mA Current Monitor
Isolation: None from PV or system
264 V AC double insulated from PSU and Alarm types: Over current, SSR short circuit,
communications SSR open circuit
Functions: Includes alarm acknowledge, SP2 select, Indication type: Flashing beacon
manual, keylock, timer functions, Special Features
standby select
Features Energy monitoring, recovery point
Logic Output Module
Output
Notes
Rating: ON 12 V DC @ <44 mA 1. Calibration accuracy quoted over full ambient operating range and for all input
OFF <300 mV @ 100 μA linearization types
Isolation: None from PV or system. 2. Contact Eurotherm® for details of availability of custom downloads for
264V ac double insulated from PSU alternative sensors
and communications 3. Voltage output can be achieved by external adaptor
Functions: Control outputs, alarms, events
Triac Output
Order Codes
1 2 3 4 5 6 7 8 9 10
Accessories
HA031260 Engineering/CD manual
SUB35/ACCESS/249R.1 2.49R Precision resistor
RES250 250R resistor for 0-5 V DC OP
RES500 500R resistor for 0-10 V DC OP
CTR100000/000 10 A Current transformer
CTR200000/000 25 A Current transformer
CTR400000/000 50 A Current transformer
CTR500000/000 100 A Current transformer
iTools/None/3000CK Configuration clip
SUB21/IV10 0-10 V input adaptor
Piccolo Controller Data Sheet eurotherm.com/piccolo-controller 5
+ + NO 2A Dig in 1 LA AC NC
48 mm OP2
– – C 2B COM HD VI
RTD
L A(+) HE V+
100 to 230 V AC 50/60 Hz mV/V mA
or 24 V AC/DC N
Panel cut-out 45 mm (–0.0 +0.6) x 45 mm (–0.0 +0.6) B(–) HF V–
P108
48 mm 90 mm
+ NO NO
1A AA
OP1
Panel cut-out 45 mm (–0.0 +0.6) x 92 mm (–0.0 +0.8) – C
1B AB C OP4
NO
2A AC NC
OP2
C
2B HD COM
P104 LB HE A(+)
Dig in 2
96 mm 90 mm LC HF B(–)
+ NO 3A CT
CT
OP3
– C 3B C
Dig in 1
96 mm + 3C LA
24V
– 3D VI
RTD
L V+
100 to 230 V AC 50/60 Hz
mV/V mA
or 24 V AC/DC
N V–
Eurotherm USA
44621 Guilford Drive, Suite 100
Ashburn, VA 20147
Phone: +1-703-724-7300
Fax: +1-703-724-7301
www.eurotherm.com
Document No. HA031232USA Issue 2 ®2018 Schneider Electric. All Rights Reserved. Life Is On Schneider Electric, Eurotherm, EurothermSuite, eCAT, EFit, EPack, EPower, Eycon, Eyris, Chessell,
Mini8, nanodac, optivis, piccolo and versadac are trademarks and property of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks are the property of their