You are on page 1of 8

www.link-ltd.

com

Dış Cephe Askı ve Ankraj Sistemleri / Uygulama Örnekleri

Body Anchor Fixing System


Installation Details Installation at horizontal joints

A Fdw/1 Fdw/1

Load Bearing
1 & Restraint

Stone Slab

Wall
4
5
6
In this instance the dead load of
the slab is divided by two, as
2 half the weight of the slab is
11
transferred to the load bearing
anchors.
3
Anchor Set
Installation at vertical joints
8

7 Fdw/1 Fdw/1
9

10
Insulation 1- Through Bolt
2- Wedge Washer
3- Anchor Body Restraint
A 4- Lock Washer
Load Bearing
5- Round Washer For Through Bolt
6- Hex Nut for Through Bolt
7- Locking Plate
8- Hex Bolt In this instance the dead load of
Section A-A 9- Adjustable Arm the slab is divided by one, as the
10- Plastic Tube whole weight of the slab is
11- Flanged Pin transferred to the load bearing
anchors.
Installation at horizontal joints Installation Details
Elevation view
TA
A

TA TA TA TA TA TA TA TA

Restraint
TB TB TB TB TB TB TB
TB
TB
TB TB TB TB TB TB TB
AX04 Body Anchor

Load Bearing
TB TB TB TB TB TB TB & Restraint

TC
TB TB TB TB TB TB TB

TC TC TC TC TC TC TC
A TC Load Bearing
Installation at vertical joints
Elevation view
A

TD TD TD TA TA TD
TD
TE TE TE

TD TD TD TB TB
TE
Restraint
TE TE TE

TD TD TD TB TB TE
HSR3 Restraint Anchor
TE TE TE

TD TD TD TB TB
Load Bearing
TE TE TE

TD TD TD TB TB

TE TE TE
TC TC
A

AX04 Body Anchor

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Body Anchor

LBA
Technical Details

Fdw
For anchoring into
concrete ≥ C20/25
K
Cement
groul
E.b.
LBA 700125
Load
Bearing
LBA 70085
x

LBA 60055 Fws/Fwp


T M

LBA 60030
Restraint Ø
EAL
Plastic
tube

St F St=20-50 mm
Fdw
For anchoring into
concrete ≥ C20/25
K
Cement
groul
E.b.
Load
Bearing

x
Fws/Fwp
T M

Ø
Ø
Restraint
EAL
Plastic
tube

St F St=20-50 mm

• Optimum static performance & low engineering feature


Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm X
Product tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length Size
Code tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm) x (mm)
LBA 60030 60 50 75 900 28 1100 770 60
LBA 60055 90 75 105 800 46 700 700 80
M8X80 5 M12 4.5 50
LBA 70085 125 100 140 700 75 650 650 90
LBA 700125 165 150 180 700 115 600 600 90

• Material : Stainless Steel 1.4301 (A2) & 1.4401 (A4).


• Loads stated are characteristic resistance loads.
• Bolts are provided separately.
• Test results are available upon order.

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Uygulama Örnekleri

Body Anchor Fixing System


Technical Details

HMPC-HC1H
Technical Profil Sistemi:
Details
Direct fixing in to concrete walls with expansion bolts. Indirect fixing on to sub
channel systems with hex bolts.
Three dimensional adjustability - Quick and easy fixing.
Installation at horizontal and vertical joints.
Optimum static performance and low engineering for higher loads and larger
projection sizes.
AX01 Anchor Recommended projection sizes up to 260 mm and loads up to 1300 N.

Three dimensional adjustability

AX02 Body Anchor


± 11 mm

± 15 mm

15˚ 15˚
1) Vertical adjustment is provided 2) Adjusting the projection size by 3) Adjusting the anchor left and
AX03 Body Anchor through the body space. The anchor moving the adjustable arm without right is provided by sliding the
is fixed onto the bolt through the rotating. The adjustable arm is safely body up to 15 degrees left or
wedge washer and the lock washer fixed to the anchor body with the lock right.
at the desired level. nut and hex bolt.

AX04 Body Anchor

Installation vertical joints Installation horizontal joints

Fdw/1 Fdw/1 Fdw/1 Fdw/1

HSR3 Restraint Anchor

Restraint Load Bearing


Load Bearing & Restraint

Suitable for concrete walls. Anchors are fixed on to concrete walls with expansion bolts.
Projection sizes between 60 and 260 mm and loads up to 1300 N.
In horizontal installation, slabs are pinned on the bottom and upper sides. The anchors act as load bearing, carrying half the weight
of the slabs above. Anchors also act as restraint holding the slabs below and restraining against wind suction and pressure.
In vertical installation, slabs are pinned at the left and right sides. The anchors on the bottom are load-bearing anchors carrying the
whole weight of the slab. Half the weight of the slab on the left and half the weight of the slab on the right. The anchors on the top
are restraint anchors holding the slabs and restraining against wind suction and pressure.
Three dimensional adjustability allows quick and easy installation.
The design and structural calculations of these anchors are made in our technical department. Special design and manufacturing
can be made for the requirements of the project.

LINK www.link-ltd.com
www.link-ltd.com

Facade Fixings and Anchoring Systems / Surface Anchor

Surface Anchor
Technical Details

Profile

Fdw

Cement K
groul
Load S
Bearing

Fwp Ød
T

Restraint EAL

Plastic
tube

St
(20-50mm)
A

Surface
Lock Nut
L
W

Dead Load
Fdw Fdw Fwp
Ød A L W t K
Product Min. Max. Max.
(Acc. to Projection Distance)
Code Projection Projection Wind
30 mm 40 mm 60 mm 80 mm 100 mm Load
mm mm mm mm mm mm N N N N N N
DTM.30010 M.8 9x15 60 35 2 30 50 250 170 - - - 500
DTM.30020 M.10 11x22 70 40 3 40 80 - 370 312 250 - 750
DTM.30030 M.10 13x25 75 40 4 40 80 - 420 362 320 - 820
DTM.30040 M.12 13x25 90 45 6 50 110 - - 590 532 483 1200

T EAL Ø S
Adj.Arm Adj.Arm
Product Profile Surface
Flat Length
Section Lock Nut
Code Thickness Pin Size Bolt
Size
mm mm

DTM.30010 3 40-60 21x35 - 35x35 PLCKK.100 5 M8x20


DTM.30020 3,5 50-90 21x41 - 41x41 PLGMK.2100 5 M10x25
DTM.30030 3,5 50-90 21x41 - 41x41 PLGMK.2100 5 M10x25
DTM.30040 4,5 60-120 45x45 - 45x60 PLGMK.2200 5 M12x30

• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4).


• For more specific data is about section and surface lock nuts, please see PROLINK G and PROLINK C catalogue.
• For Adjustable Arm, please see the data sheet of ‘LBE Adjustable Arm’.
• Bolts, Surface Lock Nut, Adjustable Arm are provided separately.

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Z Anchor

ZS
Technical Details

Fdw
For anchoring into
concrete ≥ C20/25
Cement
groul K
E.b.
Load
Bearing

Fws/Fwp Drilled hole may be


T M required for closely
spaced walls.

Ø
Restraint EAL

Plastic
tube
F
St=20-50 mm
St

Technical Details
Projec- Min. Max. Dead Forming Wind- Wind- Expansion Pin Adj. Arm Adj. Arm Adj. Arm
Product
tion Projec- Projec- Load Size Pressure Suction Bolt Size Size Metric Flat Length
Code
tion tion Size Thickness
K (mm) K - (mm) K + (mm) Fdw (N) F (mm) Fwp (N) Fws (N) E.b. (mm) ø (mm) M (mm) T (mm) EAL (mm)
ZS.27.15.M10 40 35 55 15 60
ZS.27.35.M10 50 45 65 35 60
200 312 219 M8X80 5 M10 3.5
ZS.27.55.M10 70 55 85 55 70
ZS.27.75.M10 90 75 105 75 70
ZS.40.20.M10 55 50 70 20 60
ZS.40.40.M10 75 60 90 40 60
300 468 328 M8X80 5 M10 3.5
ZS.40.60.M10 95 80 105 60 60
ZS.40.80.M10 115 100 125 80 60
ZS.27.15.M12 50 40 65 15 70
ZS.27.35.M12 70 55 85 35 80
400 624 437 M8X80 5 M12 4.5
ZS.27.55.M12 90 75 105 55 80
ZS.27.75.M12 110 95 125 75 80
ZS.40.20.M12 75 60 90 20 80
ZS.40.40.M12 95 80 110 40 80
500 780 546 M8X80 5 M12 4.5
ZS.40.60.M12 115 100 130 60 80
ZS.40.80.M12 135 120 150 80 80

• Material: Stainless Steel 1.4301 (A2) & 1.4401 (A4).


• Table above is prepared according to DIN 18516 standards.
• Loads stated are working resistance loads.
• Other sizes are available for production upon request.
• Bolts are provided separately.
• Structural calculation reports are available upon order.

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Uygulama Örnekleri

Z Anchor Fixing System


Installation Details Installation at horizontal joints

A Fdw/1 Fdw/1

Load Bearing
1 & Restraint

Stone Slab

Wall
3
4
5 In this instance the dead load of
9 the slab is divided by two, as
half the weight of the slab is
transferred to the load bearing
anchors.
2
Anchor Set
Installation at vertical joints
6

7
Fdw/1 Fdw/1
8

Insulation
1- Through Bolt
2- Anchor Body
Restraint
A 3- Serrated Washer
4- Round Washer Load Bearing
5- Hex Nut For Through Bolt
6- Hex Nut for Adjustable Arm
7- Adjustable Arm
8- Plastic Tube In this instance the dead load of
Section A-A 9- Flanged Pin the slab is divided by one, as the
whole weight of the slab is
transferred to the load bearing
anchors.
Installation at horizontal joints Installation Details
Elevation view
TA
A
TA

TA TA TA TA TA TA TA

Restraint
TB TB TB TB TB TB TB

TB
TB TB TB TB TB TB TB
HZ02 Z Anchor TB

Load Bearing
TB TB TB TB TB TB TB & Restraint

TC
TB TB TB TB TB TB TB

TC TC TC TC TC TC TC
A TC Load Bearing
Installation at vertical joints
Elevation view
TD
A TD
TD TD TD TA TA

TE TE TE TE

TD TD TD TB TB Restraint

TE TE TE
TE
TD TD TD TB TB
HZ02 Z Anchor
TE TE TE
Load Bearing
TD TD TD TB TB

TE TE TE
TB
TD TD TD TB TB

TE TE TE
TC TC
Load Bearing
A
& Restraint
HRS1 Restraint Anchor

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Uygulama Örnekleri

Z Anchor Fixing System


Technical Details

HMPC-HC1H
Technical Profil Sistemi:
Details
Direct fixing into concrete walls with expansion bolts. Indirect fixing into sub
channel system with hex bolts
Three dimensional adjustability - Quick and easy fixing
Recommended projection sizes up to 135 mm & loads up to 800 N.
HZ02 Z Anchor

Three Dimensional adjustability

HZ05 Z Anchor With Reveted Nut

± 10mm

HRS1 Restraint Anchor

±15mm 150 150

1) Vertical adjustment is 2) Adjustment of the 3) Adjustment of the


provided by the slotted projection size is anchor left and right is
hole. The anchor is fixed provided by rotating the provided by sliding the
on to the bolt with the adjustable arm. The body up to 15 degrees
serrated washer at the adjustable arm is locked side ways.
desired level. with the hexagon nut.
HX08 Z Anchor for large projections

Installation vertical joints Installation horizontal joints

Fdw/1 Fdw/1 Fdw/1 Fdw/1

HZ01 Z Anchor

Restraint Load Bearing


Load Bearing & Restraint

HZ07 Soffit Anchor

Suitable for concrete walls. Anchors are fixed directly on to concrete walls with expansion bolts.
Recommended projection size between 45 mm to 135 mm and loads up to 800 N.
In horizontal joint installation, slabs are pinned on the bottom and upper sides. Anchors act as load bearing carrying half the weight
of the slabs above. Anchors also act as restraints, holding the slabs below and restraining against wind suction and pressure.
In vertical joint installation slabs are pinned on the left and right sides. Anchors on the bottom are load-bearing anchors carrying the
whole weight of the slab. Half the weight of the slab on the left and half the weight of the slab on the right. Anchors on the top are
restraint anchors holding the slabs and restraining against wind suction and pressure.
Three - dimensional adjustability allows quick and easy installation.
The design and structural calculations of these anchors are made in our technical department. Special design and manufacturing
can be made for the requirements of each project.

LINK www.link-ltd.com
www.link-ltd.com

Dış Cephe Askı ve Ankraj Sistemleri / Adjustable Arm

LBE
Technical Details

Technical Detail
Product Distance
Flat length Flattening Pin Stone
MetricSize
Reveal Size Length between
Code Size Thickness Diameter Thickness
Edge & Hole
M (mm) L (mm) AF (mm) T (mm) ø (mm) St (mm) A (mm)
LBE 51001 8 50 A+6 3 4 20 12-13
LBE 51002 8 60 A+6 3 4 25 14-16
LBE 51003 8 70 A+6 3 4 30 16-17
LBE 51010 10 50 A+8 3.5 5 40 22-24
LBE 51011 10 60 A+8 3.5 5 50 26-29
LBE 51012 10 70 A+8 3.5 5
LBE 51013 10 80 A+8 3.5 5
LBE 51030 12 50 A+8 4.5 5 T
LBE 51031 12 60 A+8 4.5 5
AF
LBE Adjustable Arm LBE 51032
LBE 51033
12
12
70
80
A+8
A+8
4.5
4.5
5
5 A
LBE 51040 14 50 A+8 5.5 6
LBE 51041 14 60 A+8 5.5 6 Ø
LBE 51042 14 70 A+8 5.5 6
LBE 51043 14 80 A+8 5.5 6
LBE 51050 16 50 A+8 6 6
LBE 51051 16 60 A+8 6 6
LBE 51052 16 70 A+8 6 6 L
LBE 51053 16 70 A+8 6 6

Type 2 With welded pin Type 3 With welded plate Type 4 With welded plate&pins Type 5 With welded shim

LBE-FP Technical Details PLGMK-TP Technical Details


Flanged Pin Product
Diameter Length
Flange Toothed P. Washer Product Thick-
Height Width Length
Code Diameter Code ness

ø (mm) L (mm) Fø (mm) T (mm) H (mm) W (mm) L (mm)


LBE-FP 61001 4 50 5 PLGMK-TP 4010 2.5 22 30 ø7
LBE-FP 61010 5 60 6 PLGMK-TP 4011 2.5 22 30 ø9
LBE-FP 61020 5 70 6 PLGMK-TP 4012 3 26 34 ø11
LBE-FP 61030 6 70 7 PLGMK-TP 4013 3 26 34 ø13
LBE-TP Technical Details PLGMK-PW Technical Details
Traced Pin Product Trace
Plain Washer
Diameter Length Product Thick-
Height Width Length
Code Height Code ness

ø (mm) L (mm) TH (mm) T (mm) H (mm) W (mm) L (mm)


LBE-TP 61040 5 70 5.2 PLGMK-PW 4000 2.5 22 30 ø7
LBE-TP 61050 6 75 6.2 PLGMK-PW 4001 2.5 22 30 ø9
PLGMK-PW 4002 3 26 34 ø11
PLGMK-PW 4003 3 26 34 ø13
LBE-SP Technical Details PLGMK-LN Technical Details
Straight Pin Product Lock Nut Product Thick-
Diameter Length Height Width Metric
Code Code ness
Hole
ø (mm) L (mm) T (mm) H (mm) W (mm) M (mm)
LBE-SP 71001 4 60 PLGMK-LN 2900 6 20 34 M6
LBE-SP 71010 5 60 PLGMK-LN 3000 8 20 34 M8
LBE-SP 71020 5 70 PLGMK-LN 3100 9 20 34 M10
LBE-SP 71030 6 70 PLGMK-LN 3200 10 20 34 M12
LBE-UP PLGMK-SP
Technical Details Technical Details
U Shaped Pin Product
Shim Plate Product Thick- Slot
Diameter Height Width Height Width
Code Code ness Hole

ø (mm) L (mm) W (mm) T (mm) H (mm) W (mm) ø x SL


LBE-UP 81001 4 20 50 PLGMK-SP 4020 2 40 30 7x20
LBE-UP 81010 5 25 50 PLGMK-SP 4021 2 40 30 9x25
LBE-UP 81020 6 30 50 PLGMK-SP 4022 3 40 50 11x25
PLGMK-SP 4023 4 40 50 13x30

LBE-CP Technical Details LBE-PT Technical Details


Capped Pin Product Cap
Plastic Tube Product Inner Outer
Diameter Length Length
Code Diameter Code Diameter Diameter

ø (mm) øC (mm) L (mm) In. ø (mm) Ou. ø (mm) L (mm)


LBE-CP 91001 4 6 35 LBE-PT 91030 4.5 6 30
LBE-CP 91010 5 7 40 LBE-PT 91040 5.5 7 40
LBE-CP 91020 6 8 45 LBE-PT 91050 6.5 8 40

• Material : Stainless Steel 1.4301 (A2) & 1.4401 (A4). Material for Plastic Tube: Polyacetal.

LINK www.link-ltd.com

You might also like