You are on page 1of 1

Standard Operating Procedure

(Stenter Machine)
1. Check Requirement
Batch Card 2. DIA, GSM, Stitch Length, Yarn Count
3. Follow any Special Instruction

1. Need Clean or not/ Filter


Machine 2. Air & Gas Pressure Sufficient or not
3. Temperature all burner same?

1. Dia wise width set up

Parameter 2. Overfeed, Under feed & Speed


3. Temperature Set fabrics type wise

1. Back side-1, Operating Side-1, Front side-1

Manpower 2. Quality Check & Fabrics feeding-1 person


3. Softener Preparation-1 person

1. Width & GSM Check

Check 2. Shade give to Quality for confirm


3. Hand feel, Quality issue confirm from Quality

Note: 1. If suddenly machine stop please open the door otherwise may be
caught fire.
2. If you got width plus from required please the Supervisor,
3. Filter keep clean,
4. If caught firing, stop the machine, blower also, can’t open the door
also & keep the mind, a fire that cannot carried outside of machine