Professional Documents
Culture Documents
AASHTO LRFD BridgeDesignSpecifications 2017 8th Ed. - Tolerancia de Agujeros
AASHTO LRFD BridgeDesignSpecifications 2017 8th Ed. - Tolerancia de Agujeros
—
6. 13. 2. 4. 1d Long-Slotted Holes
The minimum spacing between centers of bolts in In uncoated weathering steel structures, pack-out is
standard holes shall be no less than three times the not expected to occur in joints where bolts satisfy the
diameter of the bolt. When oversize or slotted holes are maximum spacing requirements specified in
used, the minimum clear distance between the edges of Article 6.13.2.6.2 (Brockenbrough, 1983).
adjacent bolt holes in the direction of the force and
transverse to the direction of the force shall not be less
than twice the diameter of the bolt.
Provided by IHS Markit under license with AASHTO © 2017 by the American Association of State Highway and Transportation Officials.
All rights reserved. Duplication is a violation of applicable law.