You are on page 1of 1

WATER REQUIREMENT; RESIDENTIAL

PROJECT :
LOCATION :
PREPARED BY :
SUBJECT: WATER TANK FOR RESIDENTIAL AREA 28.35 HECTARES
33.33 UNITS PER HECTARE
DATE MARCH : 28, 2006
A. DESIGN CRITERIA
1. NO. OF HOUSEHOLD : 945.00 UNITS
2. DESIGN PERIOD : 5.00 YEARS
3. AVERAGE 5SQ.M. PER CAPITA : 5.00 PERSONS
4. WATER CONSUMPTION RATE (WCR) : 200.00 LPCD (liters per capita per day)
5. TOTAL POPULATION (TP) : NO. OF HOUSEHOLD * AVE. NO. OF HOUSEHOLD
6. DOMESTIC CONSUMPTION (DC) : TP x WCR
7. NON-DOMESTIC CONSUMPTION (NDC) :
8. TOTAL POPULATION CONSUMPTION (TPC) : DC + NDC
9. UNACCOUNTED FOR WATER (UW) : 15% OF ADD
10. AVERAGE DAY DEMAND (ADD) : TPC + UW
11. MAXIMUM DAY DEMAND (MDD) : 130% OF ADD
12. PEAK HOUR DEMAND (PKD) : 250% OF ADD / 24 HRS.

B. WATER DEMAND
1. TOTAL POPULATION (TP) : 4,725.00 PERSONS
2. DOMESTIC CONSUMPTION (DC) : 945.00 CUMD
3. NON-DOMESTIC CONSUMPTION (NDC) : 94.50 CUMD
4. TOTAL POPULATION CONSUMPTION (TPC) : 1,039.50 CUMD
5. UNACCOUNTED FOR WATER (UW) : 183.44 CUMD
CUMD LPS GPM
6. AVERAGE DAY DEMAND (ADD) : 1,222.94 14.15 112.34
7. MAXIMUM DAY DEMAND (MDD) : 1,589.82 18.40 146.04
8. PEAK HOUR DEMAND (PHD) : 3,057.35 35.39 280.84
C. DESIGN CAPACITY OF DISTRIBUTION STORAGE TANK
1. FIRE RESERVED (Q in GPM) : 1020xSQRT(P)x(1-0.01xSQRT(P))
If the population is less than or equal to 200,000;
2. TOTAL POPULATION (P inTHOUSANDS) : 4.73
3. REQUIRED DISCHARGE (Q) : 23,612.45 CUMD 273.29 2,168.99
4. NO. OF HYDRANTS (FH) : 16.68
SAY 17.00
5. DISCHARGE PER HYDRANT (qFH) : 1,388.97 16.08 127.59
6. FOR 2 OPERATING HYDRANTS (V) : 7,655.00 GALS. in 30.00 MINUTES
(FIRE RESERVED=2 HYDRANTS in 30 MINUTES)
7. CAPACITY OF RESERVOIR : 20% OF ADD + qFH
: 72,330.00 GALS.
N0. OF WATER TANK REQUIRED SAY 1- 75,000.00 GALS.

8. N0. OF WELLS REQUIRED : MDD / (60% x 150)


(WELL CAPACITY=250GPM) : 0.97
SAY 1.00

Page 1