You are on page 1of 2

DATA SHEET FOR OVERHEAD CRANE 3 of 3

CLIENT : PT. PERUSAHAAN GAS NEGARA (Persero) Tbk. REV A B 0


LOGO PROJECT : SOUTH SUMATRA - WEST JAVA GAS PIPELINE PROJECT BY
JOB NO. : C22H2G5018 / 05-1307 CHKD
ITEM NO. : 20-M-1112 APVD
DOC. NO. : 005-20-M-DS-211 DATE Jul 06, '06 Jan 22, '07 Feb 19, '07

1 SITE : LOCATION : o OUTDOOR n INDOOR o UNDER SHELTER


2 SERVICE : OHC FOR WORKSHOP MFR. #7.
3 NO. REQUIRED : 1 MODEL NO.: #7. DRIVER : n ELECTRIC MOTOR o AIR MOTOR o MANUAL
4 OPERATING CONDITIONS UTILITY
5 ELECTRICAL
6 USAGE o MAINTENANCE n WAREHOUSE o ________________________ POWER : 380 V, 3 PH, 50 HZ
7 MAIN HOOK AUXILIARY HOOK CONTROL : 220 V, 1 PH, 50 HZ
8 MAX. CAPACITY 5 #6. TONS 2 #6. TONS AIR
9 _____________ psig _____________ F
10 LIFT 3.75 #6. m 3.75 #6. m CONSUMPTION ___________ MMSCFD
11 SPAN 13 m DRIVER #5.
12 TRAVERSING DISTANCE : 12.5 #6. m AMBIENT TEMPERATURE MIN. : 72 o
F HOISTING TRAVERS'G TRAVELLING

13 TRAVELLING DISTANCE : 9.5 #6. m MAX. : 93 o


F NO. REQ'D #7. #7. #7.
14 OPERATING HOURS _______________ hr/day RELATIVE HUMIDITY MIN. : 81.5 % MOTOR MFR. #7. #7. #7.
15 CODE & STD. n FEM n AGMA n MIGAS n IEC MAX. : 90.2 % POWER (KW) #7. #7. #7.
16 AREA CLASS n NON HAZARDOUS o HAZARDOUS: ENCLOSURE TEFC / IP 55
17 OPERATING METHOD INSULATION CLASS F
18 HOISTING o MANUAL n PENDANT o CABIN o TIME RATING INTERMITTENT
19 TRAVERSING o MANUAL n PENDANT o CABIN o
20 TRAVELLING o MANUAL n PENDANT o CABIN o INSPECTION AND TEST
21 LOCATION OF CONTROL o END OF CRANE o CENTER n ALONG SIDE FABRICATION n REQ'D o WITNESS
22 MATERIAL HANDLED : MAINTENANCE PART OF STATION EQUIPMENT MATERIAL INSP. n REQ'D o WITNESS
23 CONSTRUCTION FEATURES APPEARANCE CHK n REQ'D n WITNESS
24 DIMENSION CHECK n REQ'D n WITNESS
25 DESIGN TEMPERATURE : 95 O
F RATED LOAD TEST n REQ'D n WITNESS #4
26 TYPE n OVERHEAD o SUSPENSION o GANTRY o JIB o WALL o PILLAR OVERLOAD TEST n REQ'D n WITNESS #4
27 o MONORAIL n SINGLE GIRDER o DOUBLE GIRDER STATIC LOAD TEST n REQ'D n WITNESS #4
28 PERFORMANCE DATA MAIN HOOK AUXILIARY HOOK SHIPPING PREP. n REQ'D o WITNESS
29 LIFTING SPEED NORMAL 5 m/min. 8 m/min. WPS / PQR n REQ'D o WITNESS
30 LOW 0.8 m/min. 1.5 m/min. OTHER SPECIFICATION
31 TRAVERSING SPEED MAXIMUM : 20 m/min. LOW : 5 m/min.
32 TRAVELLING SPEED MAXIMUM : 20 m/min. LOW : 6.3 m/min. PAINTING Refer to Painting Spec. #8
33 WINCH TYPE o CRAB n HOIST o FINISH COLOR (HOLD)
34 HOOK TYPE n SINGLE o RAM HORN o LUBRICANT SPEC. Grease
35 OPERATING SWITCH n ON OFF n UP DOWN n EAST WEST n SOUTH NORTH LUBRICANT Q'TY lb
36 n NORMAL - LOW SPEED CONSTRUCTION MATERIAL #1
37 WIRE ROPE SPECIFICATION
38 TWIST #7. o Z TYPE o S TYPE o XIP GIRDER CARBON STEEL
39 DIAMETER #7. mm WHEEL CARBON STEEL
40 POWER FEEDING SYSTEM DRUM CARBON STEEL
41 HOISTING n FLEXIBLE CABLE o CABLE REEL o COLLECTOR HOOK CARBON STEEL
42 TRAVERSING n FLEXIBLE CABLE o CABLE REEL o COLLECTOR
43 TRAVELLING n FLEXIBLE CABLE o CABLE REEL o COLLECTOR ACCESSORIES AND SPARE PARTS
44 BUILDING / STRUCTURE INFORMATION
45 COLUMN CENTER SPAN 15000 mm RAIL SPAN 14200 mm MAINTENANCE STAGE n YES o NO
46 LONGITUDINAL LENGTH 10000 mm MAIN SWITCH BOX n YES o NO
47 CLEARANCE BETWEEN RAIL AND EAVES #7. mm ALARM EQUIPMENT n YES o NO
48 RAIL SPECIFICATION #7. OVERLOAD CUT-OFF DEVICE n YES o NO
49 ALLOWABLE WHEEL LOAD #7. kN/wheel RUNWAY RAIL AND CLAMP n YES o NO
50 REMARKS SUPPORT FOR CABLE n YES o NO
51 #1: ASTM grade material or eq. to be specified by Vendor POWER INDICATOR LAMP n YES o NO
52 #2: All internal cables/wiring up to main switch box shall be provided by Vendor END STOPPERS W/BOLT & NUT n YES o NO
53 #3: Space heater for motor to be provided if rating>3,7 kW TRAVEL & TRAVERSE LIMIT SWITCH n YES o NO
54 #4: To be done at site. Test load and other necessary equipment and material CABLE/WIRING #2 n YES o NO
55 for load test shall be provided by Vendor. SPACE HEATER #3 n YES o NO
56 #5: For motor rated 0.4 KW and below, use 220V / 1 Ph / 50 Hz SPARE PARTS FOR 1-YEAR n YES o NO
57 #6: For reference and will be finalized when maintenance requirement is fixed
58 #7: By Vendor
59 #8: General Specification for Painting and Protective Coating Doc. No. 005-20-M-SP-204
60 #9. This data sheet shall refer to General Specification No. 005-20-M-SP-211
61 #10. Motor shall comply with Individual Specification for
62 Induction Motor No. 005-20-E-SP-205.
63 NET WEIGHT : #7. kg GROSS WEIGHT __#7. kg SHIPPING VOLUME #7. m3