You are on page 1of 12

CHINT Solar

CHINT Solar System Solution


Contents:

I- About CHINT 01-02

1. Introduction 01-02

2. CHINT Photostatic( PV) around the world 03-04

II- Business scope and competitive advantage 05-06

1. PV equipment supply 05-06


2. PV system design 05-06

3. Professional on-site construction guidance and after-sales service 05-06

III- PV System solution 07-19

1. System application environment 07-08

2. Working Principle 07-08

3. Main equipment 09-12

4. System Solution 13-18

5. Project reference 19-19


New Energy Power P&D

Low Voltage CHINT Power


CHINT Solar
Power

s
Instruments & Mete
Automation

NOARK

Total Solution provider

CHINT Group Presentation


CHINT is committed to providing the world with safe, reliable and date, with the annual sales revenue exceeding more than 725 million
Real-time power
stable lectrical equipment and clean energy solutions. USD and over 30,000 employees around the world, CHINT has generation
After more than 30 years of growth, CHINT has developed from Asia's provided reliable electrical equipment and solutions for more than
PV
largest LV apparatus supplier to leading global electrical equipment 130 countries and regions worldwide as an active player of electric Modules
PV Combiner
Box
DC
switchboard
Inverter AC
switchboard Transformer Ring Network
Cabinet
AC Power
Grid

and integrated supplier, with strength from power generation, storage, power construction in the global market.
transmission, transformation,distribution to terminal consumption.To

01 http://en.chint.com/ http://en.chint.com/ 02
CHINT Projects Worldwide

GANSU NEIMENG

NINGXIA JIANGSU JAPAN


QINGHAI

Cases

Turn Key Solution


EPC Service Turnkey Solution

Design Measurement Manufacting Construction Installation Completion&Operation

EPC Business Scope


● Solar & Wind Power Plants and other Conventional Energy Power Plants ● Substations and Transmission Lines up to 500kV ● Oil, Gas & Chemical Industry Power System Solution ● Mining & Metallurgy Industry Power System Solution ● Civil Infrastructure Industry Power System Solution

03 http://en.chint.com/ http://en.chint.com/ 04
Business scope and competitive advantages
PV equipment supply Professional on-site construction guidance and
As the world’s leading electrical industrial chain and solutions provider, CHINT is committed to providing the
after-sales service
world leading clean energy solutions. Provided equipment includes PV module, Inverter, combiner box, power
The company has a strong and experienced team in product develo pment, system design and engineering
distribution cabinet, transformer, cables and control system, e tc. These equipment have been widely used in
construction. It can provide comprehensive PV system solutions, professional on-site construction technical
various types of PV systems. Besides, CHINT electrical equipmen t received complete approval from customers
guidance and stable after sales service.
based on their reliable and stable performance.

PV Modules Inverter AC Cabinet Transformer

Cable

Control System

System integration, scheme design

Modular design, reasonable combination of the elements of


each product based on excellent PV system integration
capabilities and abundant oversea PV sales experience won
the trust of the customers. The PV system has high power
generation efficiency, safe and reliable performance, and
can meet the requirements of various applications environ -
mental conditions.

05 http://en.chint.com/ http://en.chint.com/ 06
System solution
Based on the strong industry chain advantages, cost advantages and PV plants development, design and
construction advantage, CHINT provides the world-leading One-stop solution for PV plants.
Working Principle

System application environment


PV Inverter
Distributed PV plant is to build PV power plant by utilizing idle roof or open
and shadowless ground resources of house, industrial factories to realize
“self-sufficiency and surplus electricity feed-in to the power grid ”,
which has certain energy saving benefits. At the same time, installing
components on the roof can increase the thermal insulation performance.
In recent years, distributed PV plant has been accepted by more and Meters Grid
PV Modules
more users as an economic and environmental protection energy mode.

AC Charging Pole

Loads

DC Cable
AC Cable

Power Grid

Loads
PV Modules Inverter AC Box

07 http://en.chint.com/ http://en.chint.com/ 08
Main equipment On-grid Inverter
PV modules

Single phase PV Inverter

1~1.5kW 2~3.6kW 3~5kW 6kW

Three phase PV Inverter

4/5/6/8/10kW 20/25kW 30/36kW 50/60kW 70kW

Monocrystalline Polycrystalline BlackSerie Centralized Inverter

500kW/630kW 1.25MW/
1MW/1.26MW/2MW/2.5MW/3MW
/1MW 1.5MW(1500V)

Inverter For NA
Monocrystalline Polycrystalline BlackSerie

Cells 60-72 60-72 60-72

Output 275Wp-370Wp 255Wp-345Wp 275Wp-370Wp


3/45/6kW/US 14kW 20kW 23/28/36kW 50kW 60kW
Module Efficiency Up to 19.7% Up to 18.5% Up to 19.7% /US-208 /US-480 /US-480 /US-480 /US-480

1648x990x35mm 1648x990x35mm 1648x990x35mm


Size
1954x990x40mm 1954x990x40mm 1954x990x40mm

09 http://en.chint.com/ http://en.chint.com/ 10
Mounting system Cables and accessories

Metal Sheet Roof

Concrete Flat Roof

AC box
Tile Roof-Hook

Wooden beam roof-Hoop

11 http://en.chint.com/ http://en.chint.com/ 12
System Solution
1. 330Wp / 340Wp polycrystalline silicon PV Modules (2) PV system: From 6kW to 15KW
(1) PV system: From 1kW to 5KW

Equipment List of Distribution PV System Equipment List of Distribution PV System


System Parameter System Parameter
Capacity (kW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW Capacity (kW) 6kW 6.6kW 7.2 kW 10kW 12kW 15kW
CHSM6612P- CHSM6612P-
PV Module(W) 330 330 330 330 330 330 PV Module(W) 330 330 330 330 330 330
330W,Poly 330W,Poly
Qty of Modules 4 7 8 10 13 16 Qty of Modules 20 22 26 32 40 52
Actural Power (kW) 1.32 2.31 2.64 3.3 4.29 5.28 Actural Power (kW) 6.6 7.26 8.58 10.56 13.2 17.16

Main Equipment Main Equipment


Mounting System
Mounting System
(Tile roof/
(Tile roof/Flat Unit: set 1 1 1 1 1 1
Unit: set 1 1 1 1 1 1 Flat roof/Metal
roof/Metal sheet
sheet roof/Ground)
roof/Ground)
1*CPS SCA3KTL-S
Model Name CPS SCA1KTL-S CPS SCA2KTL-S CPS SCA2.5KTL-S CPS SCA3KTL-S CPS SCA3.6KTL-S CPS SCA5KTL-SM Model Name CPS SCA6KTL-SM 2*CPS SCA3.6KTL-S CPS SCA10KTL CPS SCA12KTL CPS SCA15KTL
1*CPS SCA3.6KTL-S
Rated AC Power(KW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW Rated AC Power(KW) 6kW 3kW+3.6kW 3.6kW+3.6kW 10kW 12kW 15kW
Max.Number of DC Max.Number of DC
1 1 1 1 1 2 On-grid Inverter 2 1+1 1+1 2 4 4
On-grid Inverter Input Input
Rated AC Rated AC
Voltage/Range 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 277-520V 277-520V 277-520V
Voltage/Range
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Disconnector 32A 32A 32A 32A 32A 32A Disconnector 32A 32A 32A 32A 32A 32A
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
Cable Cable
PV1-F-1*4mm2(m)- Cable PV1-F-1*4mm2(m)-
DC Cable 20 30 30 40 40 60 DC Cable 80 80 80 80 100 160
Estimated Estimated
MC4 Connector Female and Male 3 3 3 4 4 6 MC4 Connector Female and Male 6 6 6 6 6 10
ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - Mode ZC-YJV 0.6/1kV ZC-YJV 0.6/1kV- ZR-YJV 0.6/1kV ZC-YJV 0.6/1KV ZC-YJV 0.6/1KV ZC-YJV 0.6/1KV
Mode 3*4mm2 3*6 mm2 3*6mm2 -3*6+2*4 mm2 -3*6+2*4 mm2 -3*6+2*4 mm2
3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2
AC Cable AC Cable
Length (m)- Length (m)-
40 40 40 40 40 40 40 40 40 40 40 40
Estimated Estimated

Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the grid-connected point.
grid-connected point.

Equipment List of Distribution PV System Equipment List of Distribution PV System


System Parameter System Parameter
Capacity (kW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW Capacity (kW) 6kW 6.6 kW 7.2 kW 10kW 12kW 15kW
CHSM6612P- CHSM6612P-
PV Module(W) 340 340 340 340 340 340 PV Module(W) 340 340 340 340 340 340
340W,Poly 340W,Poly
Qty of Modules 3 7 8 10 12 16 Qty of Modules 20 22 24 32 40 52
Actural Power (kW) 1.02 2.38 2.72 3.4 4.08 5.44 Actural Power (kW) 6.8 7.48 8.16 10.88 13.6 17.68
Main Equipment
Main Equipment
Mounting System
Mounting System (Tile roof/Flat roof/
(Tile roof/Flat roof/ Unit: set 1 1 1 1 1 1
Unit: set 1 1 1 1 1 1 Metal sheet roof/
Metal sheet roof/ Ground)
Ground)
CPS SCA6KTL-SM 1*CPS SCA3KTL-S
Model Name CPS SCA1KTL-S CPS SCA2KTL-S CPS SCA2.5KTL-S CPS SCA3KTL-S CPS SCA3.6KTL-S CPS SCA5KTL-SM Model Name 1*CPS SCA3.6KTL-S 2*CPS SCA3.6KTL-S CPS SCA10KTL CPS SCA12KTL CPS SCA15KTL
Rated AC Power(KW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW Rated AC Power(KW) 6kW 3kW+3.6kW 3.6kW+3.6kW 10kW 12kW 15kW
Max.Number of DC Max.Number of DC
1 1 1 1 1 2 On-grid Inverter 2 1+1 1+1 2 4 4
On-grid Inverter Input Input
Rated AC Rated AC
Voltage/Range 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V 277-520V 277-520V 277-520V
Voltage/Range
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Disconnector 32A 32A 32A 32A 32A 32A Disconnector 32A 32A 32A 32A 32A 32A
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
Cable Cable
PV1-F-1*4mm2(m)- PV1-F-1*4mm2(m)-
DC Cable 20 30 30 40 40 60 DC Cable 80 80 80 80 100 160
Estimated Estimated
MC4 Connector Female and Male 3 3 3 4 4 6 MC4 Connector Female and Male 6 6 6 6 6 10
ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV -
Mode Mode
3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*6 mm2 3*6 mm2 3*6+2*4 mm2 3*6+2*4 mm2 3*6+2*4 mm2
AC Cable AC Cable
Length (m)- Length (m)-
40 40 40 40 40 40 40 40 40 40 40 40
Estimated Estimated
Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the grid-connected point.
from the grid-connected point.

13 http://en.chint.com/ http://en.chint.com/ 14
2.360Wp/365Wp Monocrystalline silicon PV Modules
(1) PV system: From 1kW to 5KW
(3) PV system: From 17kW to 60KW

Equipment List of Distribution PV System Equipment List of Distribu on PV System


System Parameter System Parameter
Capacity (kW) 17kW 20kW 22kW 30kW 50kW 60kW Capacity (kW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW
CHSM6612P- CHSM6612M-360W,
PV Module(W) 330 330 330 330 330 330 PV Module(W) Mono 360 360 360 360 360 360
330W,Poly
Qty of Modules 60 68 72 102 180 216 Qty of Modules 3 6 8 10 12 16
Actural Power (kW) 19.8 22.44 23.76 33.66 59.4 71.28 Actural Power (kW) 1.08 2.16 2.88 3.6 4.32 5.76
Main Equipment Main Equipment
Mounting System Mounting System
(Tile roof/Flat (Tile roof/Flat roof/
Unit: set 1 1 1 1 1 1 Metal sheet roof/ Unit: set 1 1 1 1 1 1
roof/Metal sheet Ground)
roof/Ground)
Model Name CPS SCA1KTL-S CPS SCA2KTL-S CPS SCA2.5KTL-S CPS SCA3KTL-S CPS SCA3.6KTL-S CPS SCA5KTL-SM
Model Name CPS SCA17KTL CPS SCA20KTL CPS SCA22KTL CPS SCA30KTL CPS SCA50KTL- CPS SCA60KTL-
DO/400/480 DO/480 Rated AC Power(KW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW
Rated AC Power(KW) 17kW 20kW 22kW 30kW 50kW 60kW Max.Number of DC
1 1 1 1 1 2
On-grid Inverter Input
Max.Number of DC
4 4 4 6 9 12 Rated AC
On-grid Inverter Input 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V
Voltage/Range
Rated AC
Voltage/Range 277-520V 277-520V 277-520V 277-520V 320-460V/422-528V 422-528V Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Disconnector 32A 32A 32A 32A 32A 32A
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
Disconnector 63A 63A 63A 63A 100A 100A
Cable
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
PV1-F-1*4mm2(m)-
Cable DC Cable 20 30 30 40 40 60
Estimated
PV1-F-1*4mm2(m)-
DC Cable 160 180 180 300 550 600 MC4 Connector Female and Male 3 3 3 4 4 6
Estimated
Mode ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV -
MC4 Connector Female and Male 10 10 10 14 22 30 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2
AC Cable
ZC-YJV 0.6/1KV ZC-YJV 0.6/1KV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - Length (m)-
Mode 40 40 40 40 40 40
-3*6+2*4 mm2 3*10+2*6mm2 3*10+2*6mm2 3*16+2*10mm2 3*35+1*16mm2 3*35+1*16mm2 Estimated
AC Cable
Length (m)- Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic
Estimated 40 40 40 40 40 40
power station is about 30 meters away from the grid-connected point.
Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from
the grid-connected point.

Equipment List of Distribution PV System Equipment List of Distribu on PV System


System Parameter System Parameter
Capacity (kW) 17kW 20kW 22kW 30kW 50kW 60kW Capacity (kW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW
CHSM6612P- CHSM6612M-365W,
PV Module(W) 340 340 340 340 340 340 PV Module(W) Mono 365 365 365 365 365 365
340W,Poly
Qty of Modules 60 64 72 96 162 180 Qty of Modules 3 6 8 10 12 16
Actural Power (kW) 20.4 21.76 24.48 32.64 55.08 61.2 Actural Power (kW) 1.095 2.19 2.92 3.65 4.38 5.84
Main Equipment Main Equipment
Mounting System
Mounting System (Tile roof/Flat roof/
(Tile roof/Flat roof/ Unit: set 1 1 1 1 1 1 Metal sheet roof/ Unit: set 1 1 1 1 1 1
Metal sheet roof/ Ground)
Ground)
Model Name CPS SCA1KTL-S CPS SCA2KTL-S CPS SCA2.5KTL-S CPS SCA3KTL-S CPS SCA3.6KTL-S CPS SCA5KTL-SM
Model Name CPS SCA17KTL CPS SCA20KTL CPS SCA22KTL CPS SCA30KTL CPS SCA50KTL- CPS SCA60KTL-
DO/400/480 DO/480 Rated AC Power(KW) 1kW 2kW 2.5kW 3kW 3.6kW 5kW
Rated AC Power(KW) 22kW 30kW 50kW 60kW Max.Number of DC
17kW 20kW 1 1 1 1 1 2
Max.Number of DC On-grid Inverter Input
4 6 9 12
On-grid Inverter Input 4 4 Rated AC
Voltage/Range 180-280V 180-280V 180-280V 180-280V 180-280V 180-280V
Rated AC
Voltage/Range 277-520V 277-520V 277-520V 277-520V 320-460V/422-528V 422-528V Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz Disconnector 32A 32A 32A 32A 32A 32A
50Hz/60Hz 50Hz/60Hz
Disconnector 63A 63A 100A 100A Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
63A 63A
Surge Protector 40kA 40kA 40kA 40kA Cable
40kA 40kA
Cable PV1-F-1*4mm2(m)-
DC Cable 20 30 30 40 40 60
Estimated
PV1-F-1*4mm2(m)-
DC Cable 160 180 180 240 450 500 MC4 Connector Female and Male 3 3 3 4 4 6
Estimated
MC4 Connector Female and Male 10 14 22 30 Mode ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV -
10 10 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2 3*4mm2
ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV- ZC-YJV 0.6/1KV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - AC Cable
Mode Length (m)-
3*6+2*4 mm2 3*10+2*6mm2 3*10+2*6mm2 3*16+2*10mm2 3*35+1*16mm2 3*35+1*16mm2 40 40 40 40 40 40
AC Cable Estimated
Length (m)-
Estimated 40 40 40 40 40 40 Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the
grid-connected point.
Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away
from the grid-connected point.

15 http://en.chint.com/ http://en.chint.com/ 16
(2) PV system: From 6kW to 15KW (3) PV system: from 17kW to 60KW

Equipment List of Distribu on PV System Equipment List of Distribu on PV System


System Parameter System Parameter
Capacity (kW) 6kW 6.6 kW 7.2 kW 10kW 12kW 15kW Capacity (kW) 17kW 20kW 22kW 30kW 50kW 60kW
CHSM6612M-360W, CHSM6612M-360W,
PV Module(W)
Mono 360 360 360 360 360 360 PV Module(W)
Mono 360 360 360 360 360 360

Qty of Modules 20 22 26 32 40 48 Qty of Modules 52 64 72 96 162 192


Actural Power (kW) 7.2 7.92 9.36 11.52 14.4 17.28 Actural Power (kW) 18.72 23.04 25.92 34.56 58.32 69.12
Main Equipment Main Equipment
Mounting System Mounting System
(Tile roof/Flat roof/ (Tile roof/Flat roof/
Unit: set 1 1 1 1 1 1 Unit: set 1 1 1 1 1 1
Metal sheet roof/ Metal sheet roof/
Ground) Ground)
1*CPS SCA3KTL-S CPS SCA50KTL CPS SCA60KTL
Model Name CPS SCA6KTL-SM 2*CPS SCA3.6KTL-S CPS SCA10KTL CPS SCA12KTL CPS SCA15KTL Model Name CPS SCA17KTL CPS SCA20KTL 2*CPS SCA22KTL CPS SCA30KTL DO/400/480 DO/480
1*CPS SCA3.6KTL-S
Rated AC Power(KW) 6kW 3kW+3.6kW 3.6kW+3.6kW 10kW 12kW 15kW Rated AC Power(KW) 17kW 20kW 22kW 30kW 50kW 60kW
Max.Number of DC Max.Number of DC
On-grid Inverter 2 1+1 1+1 2 4 4 On-grid Inverter 4 4 4 6 9 12
Input Input
Rated AC 180-280V 180-280V 180-280V 277-520V 277-520V 277-520V Rated AC 277-520V 277-520V 277-520V 277-520V 320-460V422-528V 422-528V
Voltage/Range Voltage/Range
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Disconnector 32A 32A 32A 32A 32A 32A Disconnector 63A 63A 63A 63A 100A 100A
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
Cable Cable
PV1-F-1*4mm2(m)- 80 PV1-F-1*4mm2(m)-
DC Cable 80 80 80 100 160 DC Cable 160 180 180 250 450 550
Estimated Estimated
MC4 Connector Female and Male 6 6 6 6 6 10 MC4 Connector Female and Male 10 10 10 14 22 30
ZC-YJV 0.6/1KV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV -
Mode 3*4mm2 Mode
3*6 mm2 3*6 mm2 3*6+2*4 mm2 3*6+2*4 mm2 3*6+2*4 mm2 3*6+2*4 mm2 3*10+2*6mm2 3*10+2*6mm2 3*16+2*10mm2 3*35+1*16mm2 3*35+1*16mm2
AC Cable AC Cable
Length (m)- Length (m)-
40 40 40 40 40 40 40 40 40 40 40 40
Estimated Estimated

Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the grid-connected point. Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the grid-connected point.

Equipment List of Distribu on PV System Equipment List of Distribu on PV System


System Parameter System Parameter
Capacity (kW) 6kW 6.6 kW 7.2 kW 10kW 12kW 15kW Capacity (kW) 17kW 20kW 22kW 30kW 50kW 60kW
CHSM6612M-365W, PV Module(W) CHSM6612M-365W, 365 365 365 365 365 365
PV Module(W) 365 365 365 365 365 365 Mono
Mono
Qty of Modules 18 22 24 32 36 48 Qty of Modules 52 60 64 90 144 180
Actural Power (kW) 6.57 8.03 8.76 11.68 13.14 17.52 Actural Power (kW) 18.98 21.9 23.36 32.85 52.56 65.7
Main Equipment Main Equipment
Mounting System Mounting System
(Tile roof/Flat roof/ (Tile roof/Flat roof/
Unit: set 1 1 1 1 1 1 Unit: set 1 1 1 1 1 1
Metal sheet roof/ Metal sheet roof/
Ground) Ground)
1*CPS SCA3KTL-S CPS SCA50KTL- CPS SCA60KTL-
Model Name CPS SCA6KTL-SM 2*CPS SCA3.6KTL-S CPS SCA10KTL CPS SCA12KTL CPS SCA15KTL Model Name CPS SCA17KTL CPS SCA20KTL 2*CPS SCA22KTL-S CPS SCA30KTL
1*CPS SCA3.6KTL-S DO/400/480 DO/480
Rated AC Power(KW) 6kW 3kW+3.6kW 3.6kW+3.6kW 10kW 12kW 15kW Rated AC Power(KW) 17kW 20kW 22kW 30kW 50kW 60kW
Max.Number of DC Max.Number of DC
On-grid Inverter 2 1+1 1+1 2 4 4 On-grid Inverter 4 4 4 6 9 12
Input Input
Rated AC Rated AC 277-520V 277-520V 277-520V 277-520V 320-460V/422-528V 422-528V
Voltage/Range 180-280V 180-280V 180-280V 277-520V 277-520V 277-520V Voltage/Range
Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz Rated Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Disconnector 32A 32A 32A 32A 32A 32A Disconnector 63A 63A 63A 63A 100A 100A
Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA Surge Protector 40kA 40kA 40kA 40kA 40kA 40kA
Cable Cable
PV1-F-1*4mm2(m)- PV1-F-1*4mm2(m)-
DC Cable 80 80 80 80 100 160 DC Cable 160 180 180 220 420 550
Estimated Estimated
MC4 Connector Female and Male 6 6 6 6 6 10 MC4 Connector Female and Male 10 10 10 14 22 30
ZC-YJV 0.6/1KV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1kV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV- ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV - ZC-YJV 0.6/1KV -
Mode Mode
3*4mm2 3*6 mm2 3*6 mm2 3*6+2*4 mm 2 3*6+2*4 mm 2 3*6+2*4 mm 2 3*6+2*4 mm 2 3*10+2*6mm2 3*10+2*6mm2 3*16+2*10mm2 3*35+1*16mm2 3*35+1*16mm2
AC Cable AC Cable
Length (m)- Length (m)-
40 40 40 40 40 40 40 40 40 40 40 40
Estimated Estimated
Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the Note: The cable length refers to the flat layout of the tilted roof . Suppose the building elevation is 15 meters and the photovoltaic power station is about 30 meters away from the grid-connected point.
grid-connected point.

17 http://en.chint.com/ http://en.chint.com/ 18
Project reference

Singapore 10KW Project

France Grosdenier 243 KW Rooftop Project

Ghana 10KW PV System

Japan Kumenan 100KW Project

Brazil Natal Project

Thailand Saraburi Project Brazil Roof PV Project

19 http://en.chint.com/

You might also like