You are on page 1of 1

SWELLING TEST

PROJECT : GUDANG HYPERMART DATE : 28 ~ 31 JAN. 2020


LOCATION : MPPA DC HYPERMART BALARAJA, TESTED BY : Bw. Cs
TOBAT, TANGERANG - BANTEN

Sample code DB. 1 DB. 2 NOTES


Mold No. 1
Before After Before After Before After
Swelling cm. - 0.865 - 0.430
Wt. of water absorbed gr. - 318.000 - 62.000
Diameter of sample cm. 15.000 15.000 15.200 15.200
Height of sample cm. 11.800 12.665 11.800 12.230
Volume of sample cm3. 2,084.18 2,236.92 2,140.12 2,218.06
Wt. of mold gr. 4,165.000 4,165.000 4,110.000 4,110.000
Wt. of mold+sample gr. 7,934.000 8,252.000 8,106.000 8,168.000
Wt. of sample gr. 3,769.000 4,087.000 3,996.000 4,058.000
Water Content. % 30.000 37.056 20.800 36.083
Wt. of dry sample gr. 2,982.000 2,982.000 2,982.000 2,982.000
Wet Density gr/cm3. 1.808 1.827 1.867 1.830
Dry Density gr/cm3. 1.391 1.333 1.546 1.344
Specific gravity - 2.638 2.578
Void ratio - 0.896 0.979 0.707 0.962
Degree of Saturation % 88.288 99.863 75.878 98.928

SWELLING RECORDS
Swell Reading Swell Reading Swell Reading NOTES
Date Time
mm % mm % mm %

28 JAN 2020 : 11.00 WIB 0 0 0 0 0


30' 1.078 0.914 0.110 0.093
1 hr. 2.295 1.945 0.222 0.188
2 hr. 3.050 2.585 0.470 0.398
3 hr. 3.182 2.697 0.772 0.654
4 hr. 3.535 2.996 1.090 0.924
29 JAN 2020 24 hr. 6.229 5.279 2.172 1.841
30 JAN 2020 48 hr. 7.953 6.740 3.239 2.745
31 JAN 2020 76 hr. 8.648 7.329 4.297 3.642

AFTER SOAKING
Wt. of Mold + Soil
- After Soaking gr. 8252.00 8168.00
- Before Soaking gr. 7934.00 8106.00
Wt. of water absorbed gr. 318.00 62.00
Water absorbed %. 8.44 1.55

NO. :