MicroCAS Supervision Relay


Table of Contents

Table of Contents
TECHNICAL DATA................................................................................................................................. 2
Technical data......................................................................................................................................2

MicroCAS Supervision Relay Technical specification 1


TECHNICAL DATA

TECHNICAL DATA
Technical data
The MicroCAS is an electro-mechanical supervision relay intended for monitoring the
stator temperature in Flygt sewage pumps.
The thermal contacts mounted inside the stator winding are connected to the MicroCAS. If
the temperature should exceed the limit value set for the thermal contacts, the built-in
interlock relay will change over, and the red alarm LED will light up at the same time.
The interlock relay will stop the pump.
Power supply: 24 V AC, 50/60 Hz ± 15%

Ambient temperature: in operation: 0°C to 50°C


in storage: –25°C to 70°C

Ambient humidity: 90% RH

Input signal criteria: The thermal contacts must be connected to the sensor
input
1. Normal conditions R = 0 ohm
2. High temperature R = ∞ ohm

Relay output1 Change-over relay, 5 A/240 V


The relay is de-energized when power supply is switched
on and conditions are normal (thermal contacts closed)

Power consumption 3.5 VA

OPERATION

Temperature alarm function: Change-over relay output:


1-3 normally closed (operation)
1-4 alarm

Reset: By external push-button at terminals 6-11 or by


interrupting the power supply

Indications: Power supply OK: green LED


Alarm: red LED
APPROVALS

LV Directive: IEC-947/1
SS-EN 60 335-1
SS-EN 60 204-1

INSTALLATION

On 11-pole base which, in turn, is mounted on a


symmetrical DIN rail.

1 Note:
Avoid inadvertent starting of the pump:
In the event of an alarm (thermal contacts open) and inadvertent loss of power supply ( 24 V AC), the alarm interlock will open (the pump
will start) if there are different voltages at the power supply (10-2/24 V AC) and at the alarm relay output (1-4-3/220 V AC).
It is therefore recommended that a common source of power supply (24 V AC) should be used for the power supply (2-10) and the
auxiliary relay (1-3-4).

2 MicroCAS Supervision Relay Technical specification


TECHNICAL DATA

DIMENSIONS:

Width 33 mm
Height 79 mm
Depth 75 mm

PART NUMBER: 835843


N.B. The MicroCAS is not interchangeable with the MiniCAS II without electrical
reconnection of the 11-pole base. See the wiring diagram on the side of the relevant
product.

CAUTION:
Isolate the power supply before carrying out work on the MicroCAS.
The relay base may be live at 250 V AC.

Figure 1

MicroCAS Supervision Relay Technical specification 3


Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company

We're 12,000 people unified in a common purpose: creating


innovative solutions to meet our world's water needs. Developing new
technologies that will improve the way water is used, conserved, and
re-used in the future is central to our work. We move, treat, analyze,
and return water to the environment, and we help people use water
efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with
customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of
innovation.

For more information on how Xylem can help you, go to xyleminc.com

Xylem Water Solutions AB Visit our Web site for the latest version of this document and
more information
Gesällvägen 33
174 87 Sundbyberg The original instruction is in English. All non-English
instructions are translations of the original instruction.
Sweden
Tel. +46-8-475 60 00 © 2011 Xylem Inc

Fax +46-8-475 69 00
http://tpi.xyleminc.com

893394_1.1_en.GB_2012-01_TS_MICROCAS

You might also like