NET POSITIVE SUCTION HEAD
by Ross Mackay
“Never, in this world of human conflict, Consequently, every major pump manufacturer can tell
have so many been indebted to so few you the NPSH required by their pump when operat-
for so much.” ing at a particular Head-Capacity condition. When
exactly that amount is supplied, the pump will be cavi-
These words were delivered by Winston Churchill tating, but at such a low level of energy that the result-
when he was Prime Minister of Britain, in praise of ing symptoms (i.e. noise, vibration and impeller dam-
the Royal Air Force during the early days of the World age) will be difficult to detect, and the long term det-
War II. Today, they could be easily attributed to NPSH riment to the operation of the pump will be minimal.
and Cavitation. Engineers all over the world are
indebted to a very tiny percentage of the operating So Let’s Get Practical...... Before you start getting
family of pumps for an over-abundance of analysis, involved in detailed analysis and discussion of your
discussion and confusion. cavitation problem, make sure you are first following
the basic rules of engagement.
More paragraphs have been penned on this topic than
on every other aspect of pumping combined, yet the To avoid cavitation in the vast majority of cases, the
vast majority of the world’s pumps have never NPSH Available from the system must be greater that
experienced the problem because those involved the NPSH required by the pump. Usually a few feet of
followed one simple rule. a difference will be sufficient.
Conclusion
First of all, is this really cavitation I am dealing with, Ross Mackay specializes in helping companies
or is it air entrainment or recirculation? If it isn’t reduce pump operating and maintenance costs
Cavitation, no amount of adjustment of NPSH will be by conducting training courses in person,
effective. and through a self-directed video program.
Secondly, am I providing enough NPSH to the pump? Ross Mackay Associates Ltd.
P.O. Box 670-PMB-29, Lewiston, NY, 14092
If you can say ‘yes’ to both these questions, the 4 Simmons Crescent, Aurora, ON, Canada L4G 6B4
likelihood is that your cavitation will disappear. If it Tel: 1-800-465-6260 Fax: 1-905-726-2420
doesn’t, you have one of these very special and Email: ross@rossmackay.com
Web Site: www.rossmackay.com
important cases that are being discussed in the other
articles in this issue of Pumps and Systems.