You are on page 1of 1

TROMP CURVE CALCULATION

Plant : Guayaquil CM1 Circ. factor = 2.7 [-]


Separator : Polysius Sepol 250/4 D75/D25= 1.85 [-]
Date : 12.3.2007 By-pass = 8 [%]
Cement : CEM 1PGU n (RRSB) = 0.98 [-]
2.34 [%]R48[µm] d' = 13.1 [µm]
Residue 11.72 [%]R32[µm] Std.Dev.= 0.983 [-]
Particle size Feed size Tailings Fines Tromp value Efficiency
[µm] [%] [%] [%] [%] [%]
1 4.4 1.6 9.0 23.0 76.7
1.5 6.1 2.3 12.7 21.8 76.8
2 8.0 2.9 16.6 23.4 77.1
3 11.1 4.1 23.0 20.5 77.0
4 13.4 4.8 27.9 13.7 77.4
6 16.9 5.6 36.0 7.8 79.2
8 19.7 6.0 42.9 10.9 81.1
12 24.7 6.8 54.8 14.3 82.7
16 29.1 7.8 64.9 22.8 83.1
24 36.1 10.4 79.3 53.5 82.0
32 43.2 16.5 88.3 79.4 76.1
48 60.2 37.9 97.7 94.1 60.5
64 74.1 58.8 99.9 99.7 50.2
96 90.1 84.3 100.0 100.0 41.3
128 96.9 95.1 100.0 100.0 38.4
192 100.0 100.0 100.0
Blaine 1801 1066 4004 [cm²/g]
Umlauf= #DIV/0!

Uq = #DIV/0!

TROMP CURVE - Guayaquil CM1 Polysius Sepol 250/4

100

90

80
SEPARATION / EFFICIENCY [%]

70

60

50

40

30

20

10

0
1 10 100 1000
PARTICLE SIZE [µm]

461294648.xls Vers.2.0/PWi/17.07.01 Holcim Group Support Ltd / CTS