INITIALIZING TURRET INDEXING DESCREPANCY

TSIS X(SIGMA) Control

l. Power ON, release E-Stop, push Stand By key, wait for Hydraulic to start then
press E-Stop.

2. Unclamp turret head by pressing SPINDLE STOP and TAPE keys


simultaneously.

3. Check Diagnostic screen: Press Return to get to home page, press Oper./lvlaint.,
press F4 System, use affow keys to highlight #2 Diagnose, press Input, press F6 X
contact. (DGN) X004 Bit 0:0 Bit 1 : l(turret is unclamped)

4. Bring Turret Station #1 to cutting position by rotating by hand.

5. Clamp the Turret by pressing SPINDLE STOP and TAPE keys simultaneously.

6. Check Diagnostic screen: Press Return to get to home page, press Oper./Maint.,
press F4 System, use arrow keys to highlight #2 Diagnose, press lnput, press F6 X
contact. (DGN) X004 Bit 0: t Bit 1 = 0.(turret is clamped)

7. Go to F-SYSTEM screen: press Return to get to home page, press Oper./Maint.,


F4 System, use arrow keys to highlight #30 FMENU, press Input,use arrow keys
to highlight F_SYSTEM, press Input write down the 4th axis position.

8. Press ALT 3 times to back out of F-SYSTEM screen

9. Turn machine parameter change enable on: press Return to get to home page,
press F5 set, use arrow keys to highlight Rewrite Parameter Enable Valid, press
Input.

10. Turn Fanuc parameter change on (SETTINGS page): press Retum to get to home
page, press Oper./Maint., F4 System, use anow keys to highlight #30 FMENU,
press Input, use arrow keys to highlight F_SETTING press input use arrow keys
to highlight Parameter enable turn on?????

1 1. Press Returnto get to home page, press Maint., press F4 System, Param??Change
:
NC-Parameters #101 5 2 to 4 (fourth axis number for the turret), #1 8l 5.4 1 to 0
(absolute position detector for fourth axis).??????

12. Press Return to get to home page, press Maint., press F4 System, use arrow keys
to highlight #30 FMENU, press lnput, Highlight F_PMC press input, press F??
PMC PRM, press F?? KEEPRL, Change PC-Parameter K00.3 :0 to l???????

13. Tum off the control.

¡
,

14. Tum on the control release E-STOP and press STAND BY key.

15. Press the E-STOP:

16. Unclamp turret head by pressing SPINDLE STOP and TAPE keys
simultaneogply. Check Diagnostic screen. @ress Return to get to home page,
press Oper./IvÍaint., press F4 System, use arrow keys to highlight #2 Diagnose,
press Input, pross F6 X contact.) (DGN) X004 Bit 0:0 Bit I = I (Turet is
Unclamped)

17. Release E-STOP and press STAND BY key.

18. Press and release SPINDLE STOP and TURRET INDEX keys simultaneously.

19. Turn safety key to HAND mode.

20. Rotate the tünet one revolution in + direction by using the handte. Look at the F- l

SYSTEM screen (press Retum to get to home page, press Oper./I\4aint., F4


System, use rurow keys to highlight #30 FMENU, press Input,use arrow keys to
highlight F-SYSTEM, press Inpu| and stop at the position recorded in step 5.

21. Clamp the Turret by pressing SPINDLE STOP and TAPE keys simultaneously.
Check Diagnostic screen (Press Return to get to home page, press Oper./Ivlaint.,
press F4 System, use rurow keys to highlight #2 Diagnose, press Input,'press F6 X
contact.) (DGN) X004 Bit 0 = I Bit 1 :0. (Turret is Clamped)

22. Press the E{TOP.

23. Reset NC-Parameters #1015 = 2,#1815.4: I.

24. Reset PC-Parameter KEEPRLY K00.3 = 0.

25. Lock Parameters, machine parameters enable off, and Fanuc parameter change
off.

26. Power maclÉne down.

27. Power machine up, release E-STOP, and press STAND BY.

28. Go to F-SYSTEM screer! check value of 4ü axis posiüon, it should be close to 0.

29.ln MDI mode fiytool change, ex: T200; insert, Cycle Start.