l. Power ON, release E-Stop, push Stand By key, wait for Hydraulic to start then
press E-Stop.
3. Check Diagnostic screen: Press Return to get to home page, press Oper./lvlaint.,
press F4 System, use affow keys to highlight #2 Diagnose, press Input, press F6 X
contact. (DGN) X004 Bit 0:0 Bit 1 : l(turret is unclamped)
5. Clamp the Turret by pressing SPINDLE STOP and TAPE keys simultaneously.
6. Check Diagnostic screen: Press Return to get to home page, press Oper./Maint.,
press F4 System, use arrow keys to highlight #2 Diagnose, press lnput, press F6 X
contact. (DGN) X004 Bit 0: t Bit 1 = 0.(turret is clamped)
9. Turn machine parameter change enable on: press Return to get to home page,
press F5 set, use arrow keys to highlight Rewrite Parameter Enable Valid, press
Input.
10. Turn Fanuc parameter change on (SETTINGS page): press Retum to get to home
page, press Oper./Maint., F4 System, use anow keys to highlight #30 FMENU,
press Input, use arrow keys to highlight F_SETTING press input use arrow keys
to highlight Parameter enable turn on?????
1 1. Press Returnto get to home page, press Maint., press F4 System, Param??Change
:
NC-Parameters #101 5 2 to 4 (fourth axis number for the turret), #1 8l 5.4 1 to 0
(absolute position detector for fourth axis).??????
12. Press Return to get to home page, press Maint., press F4 System, use arrow keys
to highlight #30 FMENU, press lnput, Highlight F_PMC press input, press F??
PMC PRM, press F?? KEEPRL, Change PC-Parameter K00.3 :0 to l???????
¡
,
14. Tum on the control release E-STOP and press STAND BY key.
16. Unclamp turret head by pressing SPINDLE STOP and TAPE keys
simultaneogply. Check Diagnostic screen. @ress Return to get to home page,
press Oper./IvÍaint., press F4 System, use arrow keys to highlight #2 Diagnose,
press Input, pross F6 X contact.) (DGN) X004 Bit 0:0 Bit I = I (Turet is
Unclamped)
18. Press and release SPINDLE STOP and TURRET INDEX keys simultaneously.
20. Rotate the tünet one revolution in + direction by using the handte. Look at the F- l
21. Clamp the Turret by pressing SPINDLE STOP and TAPE keys simultaneously.
Check Diagnostic screen (Press Return to get to home page, press Oper./Ivlaint.,
press F4 System, use rurow keys to highlight #2 Diagnose, press Input,'press F6 X
contact.) (DGN) X004 Bit 0 = I Bit 1 :0. (Turret is Clamped)
25. Lock Parameters, machine parameters enable off, and Fanuc parameter change
off.
27. Power machine up, release E-STOP, and press STAND BY.
29.ln MDI mode fiytool change, ex: T200; insert, Cycle Start.