MAINTENANCE MODE
Keep
Pressing 1 time 1 time 5 times
1. Version
ENT Exit
2. Install
ENT Exi
2. The display indicates three items:
1. Display Firmwarer,
2 Main Firmware
3 Validator Firmware.
ENT Exi
4. The display indicates present firmware version and
the file name in CF card (Compat Flash Card).
K12:
The updating takes about 2 minutes for Display
Firmware, 5 minutes for Main Firmware and 8 minutes
for Validator Firmware.
K4, K8:
The updating takes about 5 minutes for Display
Firmware, 5 minutes for Main Firmware and 8 minutes
for Validator Firmware.
3. System Setting
1. Move the cursor to 3. System Setting by
pressing▲▼key and press F1 key “ENT”.
ENT Exit
2. Move the cursor to desired item by pressing▲▼key.
3. Press F1 key “ENT”.
ENT Exit
3. Move the cursor to desired memory switch bit by
pressing F1 and F2 key.
4. Press F3 key to set ON and press F4 key to set OFF
<EX1>
Fit pocket and Fit facing pocket must not exist in the
same pattern.
Fit and Fit A conflict
the logic.
Unfit Face and Unfit
conflict the logic.
<EX2>
To set 1st and 2nd denomination, 2nd denomination
pocket must not come before 1st denomination. 1st
denomination must come first.
3-1-10J
MAINTENANCE MODE
(Icon: Square)
Select Face AB
Select Face CD
Other Settings
Deatail of Auto Edit mode
1. Select LED color
LED color can select depends customer of
request. Fix Mode
3-6-2 RJ Setting
6. Press
Note:
Tape detection setting for Fit and ATM mode is
available at Fittness Detail Setting.
Sort Mode / Face Mode / Issue Mode:
Lv setting is available in RJ Setting
When Lv was set, this setting has priority to Fitness
Detail Setting.
Caution:
This Lv level’s are same scale with tape setting in
Fitness Detail Setting.
If this Lv setting was made, Tape setting in Fitness
Detail Setting is not possible to change.
If it was set Unfit or Reject, Tape detection
functions according Fitness Detail Setting.
3-1-12J
MAINTENANCE MODE
CF Tape setting
Reference: CF Tape
The counterfeit which is partly genuine bank note
may be jointed with long tape. Therefore such
long taped notes are specified as CF Tape note.
The destination of CF Tape note is selected
separataly from normal Tape note.
Purpous:
This function may be used, if Administrator forget the
password.
After clearing the password, it becomes default.
Purpous:
This function may be used when updating Validator
firmware such as adding data for new issued
denomination along with security chip replacement.
Please follow the instruction for the subject Validaor
firmware update.
Purpous:
This function may be used when updating Validator
firmware such as adding data for new issued
denomination along with security chip replacement.
Please follow the instruction for the subject Validaor
firmware update.
4. Logging
ENT Exit
1. Move the cursor to desired item by pressing ▲▼
key and press F1 key “ENT” to show the logging.
5.Test
ENT Exit
1. Move the cursor to desired function by pressing
▲▼ key and press F1 key “ENT”.
5-1 Aging
Factory use only. The machne moves without notes
continuously.
5-2 Sensor
Sensor Check
Page 1/8 Page 2/8 Page 3/8 Page 4/8 Page 5/8 Page 6/8 Page 7/8 Page 8/8
201A 301C 303B 402A 407B 409A 505B 554A
251A 301D 304A 403A 501A 506A USW1
408A
251B 301E 304B 403B 501B 507A USW2
It1 (ITU) 301F 351A 404A 451A 502A 507B
It2 (ITD) 302A 352B 405A 452A 503A 508A
It3 (ITB) 302B 352C 405B 453A 503B 551A
301A 302C 401A 406A 504A 552A
454A
301B 303A 401B 407A 505A 553A
MSW
SSW
3-1-22J
MAINTENANCE MODE
Page 1/5 Page 2/5 Page 3/5 Page 4/5 Page 5/5
201A 301C 303B 402A 407B
251A 301D 304A 403A
408A
251B 301E 304B 403B
It1 (ITU) 301F 351A 404A 451A
It2 (ITD) 302A 352B 405A 452A
It3 (ITB) 302B 352C 405B 453A
301A 302C 401A 406A
454A
301B 303A 401B 407A
MSW
USW1
5-5 Display
1. Move the cursor to desired function by pressing
▲▼key.
5-5-2 Backlight
Backlight ON or OFF Test
6. Adjustment
ENT Exit
Length
Corrected
value
7. Validator Adjustment
Refer to “4-4. Validator Adjustment” for more detail.
8. Validator Info
This function is to indicate validator detection result.
2. Count Notes.
3-1-31J
MAINTENANCE MODE
3. Select the manu by pressing ▲▼ key. Press F1 key
ENT.
Unit is digre
8.Memory Read
Factory Use Only.
Do not use this function.