3-1-1J

MAINTENANCE MODE

■How to Enter Maintenance Mode

While showing Stand-by Screen,


press following key in order
simultaneously keep pressing
Function Key.

1. Press F2 key 1 time.


2. Press F3 key 1 time.
3. Press F4 key 5 times.

Then the display indicates


Maintenance Mode Screen.

Keep
Pressing 1 time 1 time 5 times

(Image for K12)

Maintenance Mode Stand-By Display


Display

Maintenance Mode Screen is the


illustration on the right.

The display returns Stand-By Screen


by pressing F5 key “Exit “.

Press F5 Key “Exit” to


reset.
3-1-2J
MAINTENANCE MODE

■Contents of Maintenanc Mode


No. Item Contents
1 Version / Info Indication of Display, Main and Validator Firmware Versions
2 Install Firmware Updating
Setting of Memory Switch “SW”, System, Test Note Mode, Serial
3 System Setting
Code
4 Logging Logging Data Read, Data Backup, Logging Clear
5 Test Aging, sensor check, drive test
6 Adjustment Adjustment of sensors
7 Validator Adjsutment Adjustment of Validator
8 Validator Info Indication of Validator result by distribution chart.
9 Memory Read Performing Memory Read.

1. Version

1. Move the cursor to Version / Info by


pressing ▲▼ key key.
And press F1 key “ENT”.

ENT Exit

2. The display indicates Display, Main and


Validator Firmware Versions and issued
date.
In addition, it indicates version of each
currency below Firmware Version.

3. Move to Info screen by pressing ▲▼key

The display returns Stand-By Screen by


pressing F5 key “Exit “.

(Image for K12)


4. The display indicates Date, Time, Serial
number and Security Chip Version.

5. Move to Version screen by pressing


▲▼key.

The display returns Stand-By Screen by


pressing F5 key “Exit “.
3-1-3J
MAINTENANCE MODE

2. Install

1. Move the cursor to 2. Install by pressing▲▼key


and press F1 key “ENT”.

ENT Exi
2. The display indicates three items:
1. Display Firmwarer,
2 Main Firmware
3 Validator Firmware.

3. Move the cursor to the firmware to be update by


pressing▲▼ key and press F1 key “ENT”.

The display returns Stand-By Screen by pressing F5


key “Exit “.

ENT Exi
4. The display indicates present firmware version and
the file name in CF card (Compat Flash Card).

5. Move the cursor to desire version by pressing ▲▼


key. And press F1 key “ENT”.

The display returns Stand-By Screen by pressing F5


key “Exit “.

(Image for K12)

(Image for K4, K8 Rev.1)


ENT Exi
3-1-4J
MAINTENANCE MODE
6. The display indicates as the illustration on the right.

7. If the firmware version is correct, press F1 key


“ENT” to start overwriting.

The display returns Stand-By Screen by pressing F5


key “Exit “.

(Image for K12 Display Firmware)

K12:
The updating takes about 2 minutes for Display
Firmware, 5 minutes for Main Firmware and 8 minutes
for Validator Firmware.

K4, K8:
The updating takes about 5 minutes for Display
Firmware, 5 minutes for Main Firmware and 8 minutes
for Validator Firmware.

(Image for K4, K8 Rev.1 Display Firmware.)

8. When the update completes normaly, the display


indicates “Install completed normal termination.” or
“Succesfully completed update” as the illustration on
the right.

9. For K12, turn off and on the power.


For K4, K8, press F5 key “Exit “ and turn off and on
the power.

(Image for K12)

(Image for K4, K8 Rev.1)


3-1-5J
MAINTENANCE MODE
In case of Abnormal Termination
10. In case, the display indicated “abnormal
tremination”, there was a trouble during the
update.

11. Press F5 “Exit “ key. Turn off an on the power.


If the display does not indicates Exit, turn off and
on the power.

12. Enter the maintenance and perform Firmware


update again.

(Image for K12)

(Image for K4, K8)


3-1-6J
MAINTENANCE MODE

3. System Setting
1. Move the cursor to 3. System Setting by
pressing▲▼key and press F1 key “ENT”.

ENT Exit
2. Move the cursor to desired item by pressing▲▼key.
3. Press F1 key “ENT”.

The procedure of each setting is described below.

The display turns to previous display by pressing F5 key


“Exit”.

3-1 Memory Switch


1. Move the cursor to desired memory switch number
by pressing ▲▼ key.
2. Press F1 key “ENT” to indicate setting display.

The display turns to previous display by pressing F5 key


“Exit”.

ENT Exit
3. Move the cursor to desired memory switch bit by
pressing F1 and F2 key.
4. Press F3 key to set ON and press F4 key to set OFF

The display turns to previous display by pressing F5 key


“Exit”.

Please refer to the function of Memory Switch in this


Manual.
3-1-7J
MAINTENANCE MODE

3-2 Load Country Setting


Setting for default Country.
1. Move the cursor to desired county by pressing
▲▼ key.
2. Press F1 key “ENT” to set the country.

The display turns to previous display by pressing F5 key


“Exit”.

Contents of Cuntry Setting are language, date


indication pattern, Fitness Sorting Level “Default
Setting”, CF Level “Default Setting”.

3-3 Genuine Chck


Setting of Genuine, Demonstrate and Test Mode.
1. Move the cursor to desired mode by pressing ▲▼
key.
2. Press F1 key “ENT” to set desired mode.

The display turns to previous display by pressing F5 key


“Exit”.
1.Genuine : Genuine Note Counting
2.Demonstrate : Specified Size Note Counting
Validator checks only note size for
demonstration.
3.Test : LAUREL Test Note Counting

3-4 Serial Code (K4、K8 Rev. 2, K12)


The machine serial number is set at default. In case
main board is replaced, set the serial number according
to the serial number label.

1. Move the cursor to the desired digit by pressing F1


key or F2 key and set number by pressing ▲▼ key.

2. Press F3 key “ENT” to complete the setting.

The display turns to previous display by pressing F5 key


“Exit”.
3-1-8J
MAINTENANCE MODE

3-5 Main Default Load


Factory Use only.
Default setting of electrical adjustments for Main Unit.

1. Press F1 key “ENT”.

If pressing F5 key “Exit”, the display turns to previous


display.

3-6 Fitness Menu


This function is to arrange sorting pattern for Rev.1.
Setting sorting pattern for K4K8 Rev.2 refer to 3-1-9

3-6-1 Fitness Menu for K4K8 Rev.1

1. Move the cursor to desired item by pressing ▲▼


key.

2. Press F1 key “ENT”.

If pressing F5 key “Exit”, the display turns to previous


display.
3. Move the cursor to desired item by pressing ▲▼
key.

4. Press F1 key “ENT”.

If pressing F5 key “Exit”, the display turns to previous


display.

5. Select the pocket pattern in the Mode by pressing


▲▼ key.

6. Press F1 key “ENT”.

If pressing F5 key “Exit”, the display turns to previous


display.

(The screen for K4 is different form the illustration on


the right.)
3-1-9J
MAINTENANCE MODE

7. The display indicates the present pocket pattern.


Top right of pocket in the display is blinking.

8. Select a desired sort listed left line by pressing by


pressing ▲▼ key. The desired sort will be put at the
blinking pocket.

9. Press F2 key to set next pocket.

10. After the setting, press F1 ENT key save the


setting.

If pressing F5 key “Exit”, the display turns to previous


display.
EX 1
Note) Be sure sorting pattern should not conflict the
logic.

<EX1>
Fit pocket and Fit facing pocket must not exist in the
same pattern.
Fit and Fit A conflict
the logic.
Unfit Face and Unfit
conflict the logic.

2nd denom. come


EX2
before 1st denom.
It is not logical.

<EX2>
To set 1st and 2nd denomination, 2nd denomination
pocket must not come before 1st denomination. 1st
denomination must come first.
3-1-10J
MAINTENANCE MODE

3-6-1 Fitness Menu for K4K8 Rev.2, K12 Step.2


Select edit Currency from SC1 to SC4.
Edit sorting pattern have Auto Edit mode and
Fix Edit mode. Step.2
Select Auto (Auto mode) or Custom (Fix
Edit Auto Mode: (Press F1 key) mode) by Function F1 or F2.
Currency
Direction of sorting pocket automatically
selects in order of sorted denominations.

(Icon: Square)

Meaning of above icon is first counted


denomination.

Edit Fix Mode: Icon changed to Square Bracket


Edit Fix Mode: (Press F2 key) when press F2 (Custom).
Direction of sorting pockets fixed for each
denomination.

(Icon: Square Bracket)

Meaning of above icon [1] is highest


denomination. (Example: $100 for USD)

Example of Setting: Edit Auto Mode: Icon changed to Square type


press F1 (Auto).
Mode Denomination
Step.3
Select Pocket position and Issue, directions.
Direction
Issue (<1> is latest issue) Auto Mode

Select Face AB

Select Face CD

Other Settings
Deatail of Auto Edit mode
1. Select LED color
LED color can select depends customer of
request. Fix Mode

2. Select count result of pocket in Total


When select “Excludes”, sorting pocket of
count result will not apply in Total.

3. Select Preset Number


Preset Number can select for each pocket.
Detail of Fix Edit Mode
3-1-11J
MAINTENANCE MODE

3-6-2 RJ Setting

1. Move the cursor to 2. RJ Setting by pressing ▲▼


key.

2. Press F1 key “ENT”.

3. Display indicates RJ Setting Screen.

4. Select desired reject reson by pressing ▲▼ key.

5. Select destination Unfit or Reject pocket by


pressing F1 or F2 key.

6. Press

The display turns to previous display by pressing F5


key “Exit”. Exit after setting.

Tape Lv (Level) setting

Fit Mode / ATM Mode:


Lv setting is not available in RJ Setting.
Set Unfit or Rejedt.

Note:
Tape detection setting for Fit and ATM mode is
available at Fittness Detail Setting.
Sort Mode / Face Mode / Issue Mode:
Lv setting is available in RJ Setting
When Lv was set, this setting has priority to Fitness
Detail Setting.

Lv0: Tape and CF Tape Detection are OFF.


Lv1: Tape Detection is OFF and CF Tape
Detection is ON.
Lv2: Tape Detection is the most less sensitive.
Lv10: Tape Detection is the most sensitive.

Caution:
This Lv level’s are same scale with tape setting in
Fitness Detail Setting.
If this Lv setting was made, Tape setting in Fitness
Detail Setting is not possible to change.
If it was set Unfit or Reject, Tape detection
functions according Fitness Detail Setting.
3-1-12J
MAINTENANCE MODE
CF Tape setting

When Tape detection was set Unfit, the destination


of CF Tape is selectable CF pocket or Unfit pocket.

Reference: CF Tape
The counterfeit which is partly genuine bank note
may be jointed with long tape. Therefore such
long taped notes are specified as CF Tape note.
The destination of CF Tape note is selected
separataly from normal Tape note.

When Tape detection was set Reject, CF Tape


automatically set Reject.

CF Tape Lv (Level) setting

When Tape detection was set Lv, CF Tape level


changes according Tape Lv level.

Lv0: CF Tape Detection is OFF.


Lv1: CF Tape Detection is ON.
Lv2: as above
:
Lv10: as above
3-1-13J
MAINTENANCE MODE

3-6-3 Issue RJ Setting

This setting is to select either accepting or rejecting


old issue of notes by each currency or by each mode
according to request of customer.

3-6-4 Default Setting

This function is to restore all setting in Fitmess Menu


to default.
3-1-14J
MAINTENANCE MODE
3-7 System Clear
This function is to clear setting data.

3-7-1 Admin Password Clear

Purpous:
This function may be used, if Administrator forget the
password.
After clearing the password, it becomes default.

1. Move the cursor to 1. Admin Password Clear by


pressing ▲▼ key.
(Image for K12)
2. Press F1 ENT key.

(Image for K4,K8)


3. Press F1 key “ENT” again to clear the password.

If F5 key “Exit” is pressed, the display turns to previous


display without clearing the password.

3-7-2 Fitness Setting Clear

Purpous:
This function may be used when updating Validator
firmware such as adding data for new issued
denomination along with security chip replacement.
Please follow the instruction for the subject Validaor
firmware update.

1. Move the cursor to 2. Fitness Setting Clear by


pressing ▲▼ key.

2. Press F1 ENT key.


3-1-15J
MAINTENANCE MODE

3. Move the cursor to the desired currency by pressing


▲▼ key.

4. Press F1 ENT key.

5. Press F1 ENT key.

After Fitness setting clear, the fitness settings for


subject currency become default.

3-7-3 CF Setting Clear

Purpous:
This function may be used when updating Validator
firmware such as adding data for new issued
denomination along with security chip replacement.
Please follow the instruction for the subject Validaor
firmware update.

1. Move the cursor to 3. CF Setting Clear by pressing


▲▼ key.

2. Press F1 ENT key.

3. Move the cursor to desired currency by pressing


▲▼ key.

4. Press F1 ENT key.


3-1-16J
MAINTENANCE MODE
5. Press F1 ENT key

After CF setting clear, the CF settings for subject


currency become default.

4. Logging

ENT Exit
1. Move the cursor to desired item by pressing ▲▼
key and press F1 key “ENT” to show the logging.

2. The display turns to previous display by pressing


F5 key “Exit”..

4-1 Latest 100 Errors


The display indicates error logs in temporal sequence.

1. Turn the page by pressing ▲▼ key.

The display turns to previous display by pressing F5


key “Exit”..
3-1-17J
MAINTENANCE MODE

4-2 Error Frequency


The display indicates cumulative error logs.

1. Turn the page by pressing ▲▼ key.

The display turns to previous display by pressing F5


key “Exit”..

4-3 LOG Counter


The display indicates cumulative number of RJ
“reject” resons.

Turn the page by pressing ▲▼ key.

The display turns to previous display by pressing F5


key “Exit”.

4-4 Life Counter


The display indicates life counter of each part.

1. Turn the page by pressing ▲▼ key.

The display turns to previous display by pressing F5


key “Exit”..

The value is operation hour for Motors and operation


times for clutchs, brakes and solenoid.

4-5 Log Backup


This function is to correct Backup data by CF card
(Compact Flash Card) .

1. Move the cursor to desired item by pressing ▲▼


key.
2. Press F1 key “ENT” to set.

The display turns to previous display by pressing F5


key “Exit”..
3-1-18J
MAINTENANCE MODE

While reading Backup log, the display indicate as


illustration on the right.

3. Insert CF card to the card slot on Display PCB.


Press F1 key “ENT” to collect Backup data.

The display turns to previous display by pressing F5


key “Exit”..

4-6 Log Clear


This function will clear each logging data.

1. Move the cursor to item to be cleared by pressing


▲▼ key.
2. Press F1 key “ENT”.

The display turns to previous display by pressing F5


key “Exit”..

3. Press F1 key “ENT” to clear the data.

The display turns to previous display by pressing F5


key “Exit”..
3-1-19J
MAINTENANCE MODE
4. After clearing logging data, press F5 key “Exit” and
the display turns 4-6 Log Clear display.

5.Test

ENT Exit
1. Move the cursor to desired function by pressing
▲▼ key and press F1 key “ENT”.

The display turns to previous display by pressing F5


key “Exit”.

(Image for K4, K8 Rev2 and K12)

(Image for K4, K8 Rev.1)


3-1-20J
MAINTENANCE MODE

5-1 Aging
Factory use only. The machne moves without notes
continuously.

The function starts by pressing F2 key.


The function stops by pressing F1 key. Times

The display turns to previous display by pressing F5


key “Exit”.
3-1-21J
MAINTENANCE MODE

5-2 Sensor
Sensor Check

1. Move the cursor to desired sensor by pressing ▲▼key.


2. Increas or decreas the light emittion by pressing F1 key
or F2 key.
When the sensor correspond to the cursor is blocked,
the beep sounds. Turn on or off the beep by F3 key.
3. Auto Adjustment for the sensor correspond to the
cursor starts by pressing F4 key.

The display turns to previous display by pressing F5 key


“Exit”.
List of Sensors for K12 is following.
(Function is not readly for K12.)
Page1/10 Page2/10 Page3/10 Page4/10 Page5/10 Page6/10 Page7/10 Page8/10 Page9/10 Page10/10
201A 301C 303B 402A 407B 409A 503B 551 603B 651
251A 301D 304A 403A 408A 409B 504 552 604 652
251B 301E 304B 403B 451A 509A 505A 553 605A 653
ITU 301F 351A 404A 452A 509B 505B 554 605B 554
ITD 302A 352B 405A 453A 501A 506A 601A 606 SSW
ITB 302B 352C 405B 454A 501B 507A 601B 607A USW2
301A 302C 401A 406A MSW 502A 507B 602 607B
301B 303A 401B 407A USW1 503A 508 603A 608

List of Sensors for K8 is following.

Page 1/8 Page 2/8 Page 3/8 Page 4/8 Page 5/8 Page 6/8 Page 7/8 Page 8/8
201A 301C 303B 402A 407B 409A 505B 554A
251A 301D 304A 403A 501A 506A USW1
408A
251B 301E 304B 403B 501B 507A USW2
It1 (ITU) 301F 351A 404A 451A 502A 507B
It2 (ITD) 302A 352B 405A 452A 503A 508A
It3 (ITB) 302B 352C 405B 453A 503B 551A
301A 302C 401A 406A 504A 552A
454A
301B 303A 401B 407A 505A 553A
MSW
SSW
3-1-22J
MAINTENANCE MODE

List of Sensors for K4 is following.

Page 1/5 Page 2/5 Page 3/5 Page 4/5 Page 5/5
201A 301C 303B 402A 407B
251A 301D 304A 403A
408A
251B 301E 304B 403B
It1 (ITU) 301F 351A 404A 451A
It2 (ITD) 302A 352B 405A 452A
It3 (ITB) 302B 352C 405B 453A
301A 302C 401A 406A
454A
301B 303A 401B 407A
MSW
USW1

5-3 Drive Test


Test for motors, solenoids or clatch / brake.

1. Move the cursor to desired motor or solenoid by


presing ▲▼key.
2. Test the movement by pressing F2 key or F1 key.

The display turns to previous display by pressing F5


key “Exit”..

List of drive for K12 is following.


Page1/7 Page2/7 Page3/7 Page4/7 Page5/7 Page5/7 Page5/7
MHM PKM1 PKG1 SHM2 PKG4 PKM9 PKG8
THM PKM2 PKG2 PKG5 PKG5 PKM10 PKG9
SHM1 PKM3 PKG3 PKG6 PKG6 PKM11 S6G
BPM PKM4 CLT PKG7 S5G PKM12
PKMR RJGSL BRK PKM8 SHM3 PKG7
3-1-23J
MAINTENANCE MODE

List of drive for K8 is following.


Page 1/5 Page 2/5 Page 3/5 Page 4/5 Page 5/5
MHM PKM1 PKG1 SHM2 PKG4
THM PKM2 PKG2 PKG5 PKG5
SHM1 PKG3 PKG6 PKG6
PKM3
BPM CLT PKG7 K8G
RJM PKM4 BRK PKM8
RJG

List of drive for K4 is following.


Page 1/3 Page 2/3 Page 3/3
MHM PKM1 PKG1
THM PKM2 PKG2
SHM1 PKM3 PKG3
BPM PKM4 CLT
RJM RJG BRK

5-4 Power Voltage


The display indicates each voltage of power souse.

The display turns to previous display by pressing F5


key “Exit”.

(Image for K12)


3-1-24J
MAINTENANCE MODE

The display for K8 indicates as illustration on the right.

(Image for K8)

The display for K4 indicates as illustration on the right.

(Image for K4)

5-5 Display
1. Move the cursor to desired function by pressing
▲▼key.

The display turns to previous display by pressing F5


key “Exit”..

5-5-1 LCD Test


When pressing F5 key “Exit”, the display turns to
previous display.
3-1-25J
MAINTENANCE MODE

5-5-2 Backlight
Backlight ON or OFF Test

Backlight turns OFF or ON by pressing F1 or F2 key.

The display turns previous display by pressing F5 key


“Exit”..

5-5-3 LED Test (Function is not ready for K12.)


LED ON or OFF Test

The LED turns ON or OFF by pressing F1 key or F2


key.

The display turns previous display by pressing F5 key


“Exit”..

5-6 Key Test


Press operation panel key. And correspond key
illustration on the display indicates.

The disply turns previous display by pressing F5 key “Exit”


consecutively two times.

5-7 Touchpanel Test (K4K8 Rev.2, K12)


Touch Sensor Test

The display invertes the area where you make a contact


with display.
3-1-26J
MAINTENANCE MODE
5-7 Interface Test (K4, K8 Rev.1)
Press F1 key “ENT” to enter 1.I/F Loop Test.

When pressing F5 key “Exit”, the Interface Roop Test will


turminate and the display turns to previous display.

5-8 Factory Test (K12、K4, K8 Rev.2)


Factory use only.
Do not use this function.
3-1-27J
MAINTENANCE MODE

6. Adjustment

ENT Exit

6-1. Adjustment Sensor


(Function is not ready for K12)

1. Move the cursor to Adjustment Sensor by pressing


▲▼ key.

The display turns to previous display by pressing F5 key


“Exit”.display.

(Image for K4, K8 Rev.2, K12)

(Image for K4, K8 Rev.1)

2. Press F1 key “Adjustment Sensor” to perform all


sensors adjustment.

The display turns to previous display by pressing F5 key


“Exit”.display.

In case sensor adjustment failure, the display indicates


the number. Find the sensor correspond to the number in
blow table.
Perform sensor adjustment again after cleaning the
sensor which failed adjustment.
3-1-28J
MAINTENANCE MODE

Table of number on display and Sensor (K4, K8)

Number Sensor Number Sensor Number Sensor


1 201A 21 405A 65 251A
2 301A 22 405B 66 251B
3 301B 23 407A 73 351A
4 301C 24 407B 74 351B
5 301D 25 402(402A) 75 351C
6 301E 26 404(404A) 81 451A
7 301F 27 406(406A) 82 452A
- - 28 408(408A) 83 453A
9 302A 29 502(502A) 84 454A
10 302B 30 504(504A) 89 551A
11 302C 31 506(506A) 90 552A
12 303A 32 508(508A) 91 553A
13 303B 33 501A 92 554A
14 304A 34 501B
15 304B 35 503A
409(409A
16 36 503B
)
17 401A 37 505A
18 401B 38 505B
19 403A 39 507A
20 403B 40 507B

6-2 Feed Read


1. Move the cursor to Feed Read by pressing ▲▼ key.
And Press F1 key “ENT”.

The display turns to previous display by pressing F5 key


“Exit”.

2. The display indicates normal distribution of notes


transoprtation after counting notes.
The display changes Feed ->Length -> Pitch ->
Skew-. Feed in order by pressing ▲▼ key.

The display turns to previous display by pressing F5 key


“Exit”.
3-1-29J
MAINTENANCE MODE
Pitch
Note
direction
Note Feed Note

Length

6-3 Adjustment Drive


1. Move the cursor to Adjustment Drive by pressing ▲▼
key. And Press F1 key “ENT”.

2. Move the cursor to desired motor.


Press F2 key to Start motor adjustment.
Then Press F1 to stop the adjustment.

3. Motor stops automaticaly when the adjustment was


completed normaly.

Adjustment of THM and MHM is only available.


In case adjustment is failed, the display indicates
abnormal termination.

The display turns to previous display by pressing F5 key


“Exit”..

(Image for K12)

Corrected
value

(Image for K4, K8)


3-1-30J
MAINTENANCE MODE
6-4 Adjustment Touchpanel

1. Move the cursor to Adjustment Touchpanel by


pressing ▲▼ key. And Press F1 key “ENT”.

The display turns to previous display by pressing F5 key


“Exit”..

2. Point the center of circle A by tip of a pen.

The display turns to previous display by pressing F5 key


“Exit”..

7. Validator Adjustment
Refer to “4-4. Validator Adjustment” for more detail.

8. Validator Info
This function is to indicate validator detection result.

1. Enter the maintenance mode -> Validator Info and press


F1 key ENT.

2. Count Notes.
3-1-31J
MAINTENANCE MODE
3. Select the manu by pressing ▲▼ key. Press F1 key
ENT.

4. The display indicates normal distribution of each


detection.

<8-1 Length Data (L)>

Length of left shorter edge.

<8-2 Length Data (R)>

Length of right shorter edge.

<8-3 Width Data>

Length of longer edge.


3-1-32J
MAINTENANCE MODE
<8-4 Skew Data>

Unit is digre

<8-5 Dirt Data>

<8-6 Hole Data>

<8-7 Tear Data>


3-1-33J
MAINTENANCE MODE
<8-8 Fold Data>

<8-9 Other 1 Data>

This function is not used.

<8-10 Other 2 Data>

This function is not used.

8.Memory Read
Factory Use Only.
Do not use this function.