C10.8.

The cell class includes carbon black for sunlight and ultraviolet light protection.

Corrugated plastic duct to be completely embedded in concrete shall be constructed from either
polyethylene or polypropylene. The minimum acceptable radius of curvature shall be established by
the duct supplier according to standard test methods. The duct shall have a thickness as shown in
Table 10.8.3-1. Ducts shall have a white coating on the outside or shall be of white material with
ultraviolet stabilizers added. Polyethylene duct shall be fabricated from resins meeting or exceeding
the requirements of ASTM D3350 with a cell classification of 345464A. Polypropylene duct shall be
fabricated from resins meeting or exceeding the requirements of ASTM D4101 with a cell
classification range of PP0340B14541 to PP0340B67884. Use resin containing antioxidant(s) with a
minimum Oxidation Induction Time (OIT) according to ASTM D3895 of not less than 20 min. The OIT
test shall be performed on samples taken from the finished product.