You are on page 1of 2

ICE Check certificate: TW-D-066

Check Certificates for Temporary Works


(Clause F7 of the additional conditions of contract)

Contract No. NE/2017/07


Cross Bay Link, Tseung Kwan O – Main Bridge and Associated Works

Description of Temporary Works:


This certificate covers the Design of Hoist Beam inside E&M Plant Room

The following document(s) are included in this temporary works submission:

Reference No. Rev. Title

TWD066-CAL1 - Design Calculation for Formwork for Cross Beam of V-Pier (W2,W3,E2 to E7)

TWD066-SK01 - Hoist Beam Inside E&M Plant Room

I/We+ certify that the Temporary Works described above have been properly and safely designed and the
design has been checked and found satisfactory by the checking engineer.

Date: Signed: *

for and on behalf of: China Road and Bridge Corporation (Hong Kong)
(the Contractor)

I certify that the Temporary Works described above have been properly and safely designed and that I
have checked the design and found it satisfactory.

Date: 08 January 2020 Signed:


Name: James Penny
On behalf of: Arcadis Design & Engineering
Limited

Delete as appropriate.

Person signing shall be duly authorised by the Contractor.
NOTES:
600 2200 250 1. DESIGN OF HOIST BEAM IS IN ACCORDANCE WITH CODE OF PRACTICE FOR THE
20mm THK. STIFFENER PLATE STRUCTURAL USE OF STEEL 2011, BE EN 1993-6:2007
400 400 2. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH SKETCH NO. 60329339/C1/SK0011,
SUR-I5-4
350 350 350 0012, 9511A
50 50
F2 (450X500) F2
3. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE

70
130
4. ALL STEELWORK TO BE GRADE S275 TO BS EN 10365:2017, BS EN 10025, BS EN
10210-1&2:2006, BS EN 10034:1993, BS EN 10056-1:2017, BS EN 10056-2:1993, BS EN 10067:1997

F1

F1
HOISTING BEAM HB2

190

525

525
WELDING OF STEEL SHALL BE IN ACCORDANCE WITH BS EN 1011-1 AND BS EN 1011-2 AND
(UC 203X203X86)
ELECTRODES SHALL BE IN ACCORDANCE WITH BS EN ISO 2560:2009, BE EN ISO 14341:2008,

130
BS EN ISO 14171:2010, BS EN ISO 14174:2012, BS EN ISO 14343:2009.
F2 F2 All WELDS TO BE MIN. 6mm F.W ALL ROUND UNLESS OTHERWISE NOTED.
7. ALL STEELWORK SHALL BE HOT-DIP GALVANIZED TO BS EN ISO 1461 AND PAINTED.
8. SWL PER HOIST BEAM 7000KG (LIFTING LOAD) + 80KG(TROLLEY WEIGHT)
M24 ANCHOR BOLT (EFFECTIVE EMBEDMENT DEPTH =
C 9. DESIGN OF HOIST BEAM ASSUMES MINIMUM DISTANCE BETWEEN WHEEL LOAD ALONG THE
150mm) (HEX HEAD BOLT (ISO GRADE 8.8))
TYPE 2 FIXING PLATE, RUNWAY BEAM, xw = 20mm
1150X330X20mmTHK.)
(1100X330X20mm THK 10. UNDER NO CIRCUMSTANCES SHALL EACH OF HB1 AND HB2 BE SUBJECTED TO MAX.
WORKING LOAD OF 7000KG SIMULTANEOUSLY, LIFTING LOAD OF 7000KG SHALL BE SHARED
BY HB1 AND HB2 EQUALLY DURING TRANSITION FROM ONE BEAM TO ANOTHER.
11. CONCRETE GRADE FOR PLANT ROOM STRUCTURE: C45
D
HOISTING BEAM HB1
525
M24 ANCHOR BOLT (EFFECTIVE EMBEDMENT DEPTH =
(UC 203X203X86) 130mm) (HEX HEAD BOLT (ISO GRADE 8.8)) 200mm SLAB
2800

150

150
SUR-I5-4 12mm THK. STIFFENER PLATE
Z1 (450X500) Z1
M24 ANCHOR BOLT
(EFFECTIVE EMBEDMENT PFC 150X75X10mm

Y1

Y1
450
DEPTH = 150mm) (HEX HEAD
X1
BOLT (ISO GRADE 8.8)) UC 152x152x23kg/m
HOISTING BEAM HB2 12mm THK. STIFFENER PLATE
(UC 203X203X86)
4 NOS. OF M12
BOLTS (GRADE 8.8)
SECTION C
20mm THK. STIFFENER PLATE 500
TYPE 1 FIXING PLATE, UR-I6-2 M24 ANCHOR BOLT (EFFECTIVE EMBEDMENT DEPTH
1150X300X20mmTHK.)
(1100X300X20mm THK (500X500) 200mm SLAB = 150mm) (HEX HEAD BOLT (ISO GRADE 8.8))

150

150
100

12mm THK. STIFFENER PLATE


SUR-I5-4
200

100
(450X500) PFC 150X75X10mm

310
RC WALL UC 152x152x23kg/m
200

350 350 350


4 NOS. OF M12
BOLTS (GRADE 8.8)
A
HOISTING BEAM HB2
(UC 203X203X86)
SECTION D
M24 ANCHOR BOLT (EFFECTIVE EMBEDMENT DEPTH = 130mm)
B (HEX HEAD BOLT (ISO GRADE 8.8))

200mm SLAB SUR-I5-4 200mm SLAB


UR-I6-2

150
(450X500)
(500X500)
200 100
M24 ANCHOR BOLT (EFFECTIVE EMBEDMENT DEPTH = 130mm)130 190 130 SUR-I5-4
(HEX HEAD BOLT (ISO GRADE 8.8)) (450X500)
HOISTING BEAM INSIDE E&M
130

130
100
PLANTROOM
HOISTING BEAM HB1
(UC 203X203X86) HOISTING BEAM HB2
(UC 203X203X86)

TYPE 1 FIXING PLATE, TYPE 2 FIXING PLATE, 20mm THK


1150X300X20mm THK
(1100X300X20mm THK.) 1150X330X20mm THK.)
(1100X400X20mm THK STIFFENER TWD066-SK01
TYPE 2 FIXING PLATE,
PLATE
1150X330X20mm THK
(1100X400X20mm THK.)
SECTION A SECTION B
20mm THK STIFFENER PLATE
HOISTING BEAM HB1