Professional Documents
Culture Documents
Model
TRACE AI 1200
Trace AI 1200 F: F with optional GF, VG,
TRACE 1800
Trace 1800 F/GF: F /Gfsystem and
TRACE Series
and/or Autosampler Autosampler, with optional VG
Atomic Absorption Spectrometers
Switchable Compact optional design with switchable All-reflective, high efficiency optic design,
single/double beam optic single/double beam switchable optic single/double beam
Monochromator Czerny-Turner
Wavelength 185-900nm
Wavelength scan rate 300nm/min 1200nm/min
6 lamp turret with automatic lamp selection, 8 lamp 2-D motorized array with automatic
Lamps
positioning and alignment lamp selection, positioning and alignment
TRACE 1800
Gas control Automatic gas control with auto ignition, optimization, and change-over
Flame Sensitivity 2 mg/L Cu: Abs≥0.4; RSD <0.5%
Advanced safety features including: burner head identification, automatic gas control
Safety emergency gas shut down, gas pressure monitoring, flame sensor, over temperature
Other and over current protection
Aurora has achieved ISO 9001 certification for the development, manufacturing and marketing of analytical instruments. ISO 9001
REGISTERED
PLEASE NOTE: Instrument specifications may change without notice due to ongoing product improvement.
North American Sales: Aurora Biomed Inc. International Sales: Aurora Instruments Ltd.
1001 East Pender Street 1001 East Pender Street
SOLUTIONS FOR LIFE & ENVIRONMENTAL SCIENCES
Vancouver BC Canada V6A 1W2
Phone: 1.800.883.2918 • 604-215-8700
Email: info@aurorabiomed.com
Website: www.aurorabiomed.com
urora
Illuminating Solutions
Vancouver BC Canada V6A 1W2
Phone: 604-215-8700 • Fax: 604-215-9700
Email: info@aurora-instr.com
Website: www.aurora-instr.com
TRACE Atomic Absorption Spectrometers Universal XYZ Autosampler Fast Dry Furnace Technology Online Dilution
The TRACE series of atomic absorption spectrometers ensures Aurora’s extensive robotics experience has led to the creation The Fast Dry technology allows analysis of Online dilution allows for the creation of calibration curves
the highest levels of sensitivity, accuracy and reproducibility. of the most advanced autosampler on the market. This one samples under 30 seconds. By adjusting from standard solutions using the digital micro-piston pump.
Aurora’s industry leading optics provide the sharpest image universal XYZ autosampler is compatible with all of the the preheating and cooling temperatures This dramatically decreases sample preparation times and
possible for highly accurate elemental analysis. Switching atomizers giving the most flexibility for automating protocols. and injection speeds, drying potential contamination.
between atomizers (flame, graphite furnace and The autosampler is fully capable of 3-dimentional movement times are decreased.
vapor/hydride generator) is easy with one click in the and allows sampling from almost any container including
Background Correction
software using motorized platforms. The transversely-heated bottles, tubes and microtiter plates (24, 96 and 384 well Samples are injected at an To resolve background interferences, the TRACE Series comes
graphite furnace tube provides industry-leading heating plates). optimized speed into the graphite complete with the following background correction
rates while sustaining high throughput efficiencies with furnace tube, which is preheated to a temperature techniques:
Aurora's Fast Dry technology. The universal XYZ autosampler higher than the solvent boiling point. Optimization
enables automated, high throughput analysis from almost Flame (F) Atomizer of the sample injection speed and temperature results in
ŸDeuterium
any container. The TRACE Series combines excellent Advanced features include: decreased sample splattering and drying times. This in turn ŸSmith-Hieftje
performance, reliable software and great values for a provides improved reproducibility, sensitivity and detection ŸTime-resolved
complete solution in trace metal analysis. Ÿ Fully inert Teflon spray chamber limits.
Ÿ Titanium burner head
Features Ÿ Pre-adjusted high-efficiency nebulizer
Clear, well- defined
Ÿ Automatic gas flow rate optimization When used in
Auto-Aligned 8-Lamp Array conjunction with an signals can be achieved
Ÿ Extensive safety interlocks
Ÿ Computer-controlled turret holds up to eight (8) pre- autosampler, the using the time-resolved
heated hollow cathode lamps Safety interlocks to detect: absorbance value for background correction.
- Combustion head type 1 ppb cadmium is up
Quick Switch between F, GF and VG Atomizers - Gas pressure to 0.45 Abs, with an
Ÿ Flame, graphite furnace and vapor/hydride generator - Liquid trap level RSD of less than 3%.
atomizers quickly transition using the manual or - Flame status Software
motorized platforms - Atomizer installation Key Features of the Software:
Power outage protection: Vapor/Hydride Generator (VG)
ŸSingle and batch run modes
Switchable Single/Double Beam Optics - Automatic gas valve closure Aurora's vapor/hydride generator provides enhanced ŸReal-time data output
Ÿ Switch between single beam and true double beam - Internal air tank to prevent flashback sensitivities, reduced interference and incredibly low
optics with just a single click ŸAdjustable wavelength scanning range and speed
detection limits for the determination of sub-trace levels of
mercury and hydride-forming elements. ŸLIMS support
Transversely-Heated GF Tube ŸTitle 21 CFR Part 11 compliance
Ÿ Unique design allows for a perfectly uniform ŸData output to Excel
temperature distribution, creating spatially isothermal
atomization conditions Hydride Generator & Atomizer
Model
TRACE AI 1200
Trace AI 1200 F: F with optional GF, VG,
TRACE 1800
Trace 1800 F/GF: F /Gfsystem and
TRACE Series
and/or Autosampler Autosampler, with optional VG
Atomic Absorption Spectrometers
Switchable Compact optional design with switchable All-reflective, high efficiency optic design,
single/double beam optic single/double beam switchable optic single/double beam
Monochromator Czerny-Turner
Wavelength 185-900nm
Wavelength scan rate 300nm/min 1200nm/min
6 lamp turret with automatic lamp selection, 8 lamp 2-D motorized array with automatic
Lamps
positioning and alignment lamp selection, positioning and alignment
TRACE 1800
Gas control Automatic gas control with auto ignition, optimization, and change-over
Flame Sensitivity 2 mg/L Cu: Abs≥0.4; RSD <0.5%
Advanced safety features including: burner head identification, automatic gas control
Safety emergency gas shut down, gas pressure monitoring, flame sensor, over temperature
Other and over current protection
Aurora has achieved ISO 9001 certification for the development, manufacturing and marketing of analytical instruments. ISO 9001
REGISTERED
PLEASE NOTE: Instrument specifications may change without notice due to ongoing product improvement.
North American Sales: Aurora Biomed Inc. International Sales: Aurora Instruments Ltd.
1001 East Pender Street 1001 East Pender Street
SOLUTIONS FOR LIFE & ENVIRONMENTAL SCIENCES
Vancouver BC Canada V6A 1W2
Phone: 1.800.883.2918 • 604-215-8700
Email: info@aurorabiomed.com
Website: www.aurorabiomed.com
urora
Illuminating Solutions
Vancouver BC Canada V6A 1W2
Phone: 604-215-8700 • Fax: 604-215-9700
Email: info@aurora-instr.com
Website: www.aurora-instr.com