QE Report

Subject: ICD Hardware Test Report Rev.: 01


Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-30 Page 1 of 3

Electrostatic Discharge Immunity Test


I. MODEL:
Model name Serial number
DT320RA-R111 32RAR111T1430004
DT340RA-R111 34RAR111T1430004
DT360LA-L222 36LAL222T1430003

II. STANDARD:
EN61326-1, (2005/12),Sec. 6.2

III. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
ESD
1 Noiseken ESS-2000 2011/10/26 2012/10/25
SIMULATOR
2. Thermal couple CAHO K-type N/A N/A

IV. CONDITION:
Environment temperature: 21.9 ℃, humidity: 66 %RH
Line length: Power line: 100 cm(18AWG)
Electrostatic discharge: Air discharge, Contact discharge
Polarity of output voltage:Positive and negative
Mode of operation:Single discharge
Discharge times of single point:On pre-selected points at least ten single discharge
The duration between successive discharges:1 s.
Laboratory: 3F Lab., Taiyuan

V. SETUP:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-30 Page 2 of 3

Figure 1:Setup Figure 2:Setup photo(DT320)

Figure 3: Setup photo(DT360) Figure 4 :Setup photo(DT340)

VI. RESULT:
Energy-Storage Capacitor: 150pF Discharge Resistor :330Ω Discharge
Times :10 times/ each condition
\Discharge Mode Contact Discharge Air discharge
\ESD Voltage 4KV 8KV
\Polarity + - + -
DT320RA-R111 A A B B
DT340RA-R111 A A B B
DT360LA-L222 A A B B

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-30 Page 3 of 3

performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.
The phenomenon:
B:AIR +/-8KV
1. DT340 / DT360 / DT320 測試中顯示畫面受干擾,測試後會自動回復。

CRITARIA:
Temporary degradation or loss of function or performance that is self-recoverable.

VII. DETERMINE:
V PASS FAIL

Tested By:
Date: 2011/11/30
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-29 Page 1 of 3

Radiated electromagnetic field immunity Test


I. MODEL:
Model name Serial number
DT320RA-R111 32RAR111T1430004
DT340RA-R111 34RAR111T1430004
DT360LA-L222 36LAL222T1430003

II. STANDARD:
Safety Spec. : IEC 61000-4-3, IEC 61131-2 9.6

III. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 SMGL generator Electronics Testing Center (ETC) Equipment
2 Amplifier
3 GTEM CELL
4 Antenna

IV. CONDITION:
EUT Power: 220 V AC ;frequency: 50/60 Hz
Environment temperature: 20.1 ℃, humidity: 52 %RH
Modulation: 80% AM 1kHz Sinusoidal
Test Frequency: 80-1000 MHz, 1.4-2.0 GHz, 2.0-2.7 GHz
Laboratory: Electronics Testing Center (ETC)

V. SETUP:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-29 Page 2 of 3

Figure 1:Setup photo

VI. RESULT:
Frequency
:80 MHz ~ 1000 MHz Field Strength :10 V/m Modulation (AM 1kHz 80%)
Range
Sweep -3
:≤ 1.5×10 decades/s Step Size :≤ 1 % of preceding frequency value Dwell Time :2.9 s
Rate
Frequency Range (MHz) Test Axis Polarization of Device Test Result

80~1000 x-axis Ver. A

80~1000 x-axis Hor. A

Frequency
:1000 MHz ~ 2700 MHz Field Strength :10 V/m Modulation (AM 1kHz 80%)
Range
Sweep -3
:≤ 1.5×10 decades/s Step Size :≤ 1 % of preceding frequency value Dwell Time :2.9 s
Rate
Frequency Range (MHz) Test Axis Polarization of Device Test Result

1000~2700 x-axis Ver. A

1000~2700 x-axis Hor. A

Note : “ N ” means the EUT function was correct during the test .
“ -- ” means the test could not be carried out.

VII. CRITARIA:
Normal performance within the specification.
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT3-Series Release Date: 2011-11-29 Page 3 of 3

VIII. DETERMINE:
V PASS FAIL

Tested By:
Date: 2011/11/29
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 1 of 4

Conducted Susceptibility Test


I. MODEL:
Model name Serial number
DT320RA-R111 32RAR111T1430004

II. STANDARD:
Safety Spec.: EN61000 Chapter 4-6, IEC61131-2 Chapter 9.10
Delta Spec.: EMR-Q007 Chapter5.12

III. EQUIPMENTS LIST FOR TESTING


Item Name Manufacturer Model Calibration Date Recommended
Racal. Date
1 CONDUCTED FRANKONIA CIT-10/75 2011/07/25 2012/07/24
IMMUNITY CDN M2+M3 2010/02/08 2011/02/07
2 FRANKONIA
TEST SYSTEM
3 CLAMP (FOR SCFAFFNER KEMZ 801 2011/02/09 2012/02/08
CS TEST)
4 6 dΒ Bird 75-A-FFN-06 2011/01/31 2012/01/30
ATTENUATOR

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 53 %RH
Setup value:

Laboratory: 3F Lab., Taiyuan


QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 2 of 4

V. SETUP:
Figure 1:Setup photo

Figure 2: Setup -Power line Figure 3: Setup -Signal line

DT320
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 3 of 4

VI. RESULT:
Frequency range: 0.15~80MHz, Field strength: 3V/M, Modulation (AM 1kHz 80%)
-3
Sweep Rate: ≦ 1.5×10 decades/s , Step size : ≦1% of preceding frequency value , Dwell time: 2.9Sec
Frequency Range Test Line Test Result
150KHz~80MHz Power line A
150KHz~80MHz Signal line A

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Normal performance within the specification.

VIII. DETERMINE:
V PASS FAIL

Tested By:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 4 of 4

Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 1 of 3

EFT/Burst Immunity Test


I. MODEL:
Model name Serial number
DT320RA-R111 32RAR111T1430004

II. STANDARD:
EN61000-4-4, (2004-07)
EN61131-2, (2007-07), Chapter 9.8

III. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 EMC test System EMC PARTNER TRA2000IN6 2011/09/06 2012/09/05
Capacitive
2 N/A N/A N/A N/A
coupling clamp

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 49 %RH
Coupling/decoupling network
EFT V-peak:2000V
Polarity +/-:POS/NEG
Burst period(Repetition): 300ms±20%
Burst duration: 15ms±20%
Spike frequency:5KHz
Test-time:60sec
Random spikes: OFF
EFT trigger: AUTO
Burst Syncro: ON
The relation with wave and power: Asynchronous
Line length: Power line(18AWG): 30 cm
Communication lin(24AWG): 3 m
Laboratory: 3F Lab., Taiyuan
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 2 of 3

V. SETUP:
DT320RA-R111
Figure 1:Setup photo Figure 2:Power line

Figure 3:Communication line

VI. RESULT:
Pulse:5/50ns
repetition Rate:5KHz below and Test time:1min/each condition
\Voltage\Polarity 1KV 2KV
\Test point\Mode\Result + - + -
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-23 Page 3 of 3

L
Power Line N A A A A
L-N
Communication line RS-485 A A -- --
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Temporary degradation or loss of function or performance that is self-recoverable.

VIII. DETERMINE:
V PASS FAIL

Tested By:
Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-10 Page 1 of 5

Radiated Emission Test


I. MODEL:
Model name Serial number
DT320RA-R111 32RAR111T1430004

II. STANDARD:
Delta Spec. : EMR-Q007-5.3
Safety Spec. : EN 55011, EN61131-2

III. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 Biconilog antenna Electronics Testing Center (ETC) Equipment
2 Receiver
3 Spectrum analyzer

IV. CONDITION:
EUT Power: 220 V AC ;frequency: 50/60 Hz
Environment temperature: 20 ℃, humidity: 60 %RH
Carrier frequency: Maximum carrier frequency
Direction of antenna:Vertical/Horizontal
Height of antenna:1~4m
Laboratory: ETC CHMBER 4
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-10 Page 2 of 5

V. SETUP:
Figure 1:setup
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-10 Page 3 of 5

VI. RESULT:
DT320
Horizontal:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 98.3974 19.94 peak 9.04 28.98 50.00 -21.02


2 157.4677 24.88 peak 13.17 38.05 50.00 -11.95
3 246.0737 23.98 peak 11.82 35.80 57.00 -21.20
4 396.8590 23.60 peak 15.63 39.23 57.00 -17.77
5 451.2660 20.19 peak 16.92 37.11 57.00 -19.89
6 530.5448 15.65 peak 18.15 33.80 57.00 -23.20
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-10 Page 4 of 5

Vertical:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 40.8814 25.94 peak 12.98 38.92 50.00 -11.08


2 40.8814 25.94 peak 12.98 38.92 50.00 -11.08
3 155.9135 21.71 peak 13.16 34.87 50.00 -15.13
4 191.6667 22.40 peak 11.00 33.40 50.00 -16.60
5 238.3013 25.21 peak 11.65 36.86 57.00 -20.14
6 396.8590 22.05 peak 15.63 37.68 57.00 -19.32
7 594.2788 22.89 peak 19.21 42.10 57.00 -14.90
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-01
Model Name: DT320 Release Date: 2011-11-10 Page 5 of 5

Test Engineer:XYZ
備註X
1. Result = Level + Factor
2. Margin = Result - Limit
3. Factor = 天線因子 + 信號電纜損失 – 放大器增益(有使用時)
4. 接收天線調整高度為 1~4m
5. 表中如有: 〝----〞, 表示 QP Result 小於 AVG Limit,不必再使用平均值檢波器測量
〝***〞, 表示干擾值太小,故不予記錄
〝#〞, 表示干擾值很低,記錄其峰值
6. 量測不準確度: ±4.6dB (30MHz≦fZ300MHz)
±4.2dB (300MHz≦fZ1eHz)
±4.1dB (1eHz≦f≦1VeHz)

VII. CRITARIA:
The measured noise shall be below limits

VIII. DETERMINE:
V PASS FAIL

Tested By: Adun.Lin_


Date: _2011/11/10_
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 1 of 4

Conducted Emission Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. STANDARD:
IEC 61326-1-7.2:2006

III. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

IV. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 Receiver R&S ESCI 2011/11/08 2012/11/07
2 LISN R&S ENV4200 2011/11/08 2012/11/07
3 Thermocouples CAHO J type N/A N/A
4 HMI DELTA DOP-B10S411 N/A N/A
5 DC Power Supply DELTA EOE12010002 N/A N/A

V. CONDITION:
Input voltage: 110 VAC
Environment temperature: 26 ℃, humidity: 50 %RH
Line length: Power line 1 meter (L, N),
Communication line 3 meter
Laboratory: 3F

VI. SETUP:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 2 of 4

Figure 1:Setup photo Figure 2:Setup photo

VII. RESULT:
DT330 / DOP-B10S411

Freq. Limits Limits


Phase QP AV
(MHz) (dBμV) (dBμV)
0.306 47.76 79 43.20 66
0.510 54.69 73 48.17 60
0.530 L1 53.68 73 40.04 60
1.982 47.81 73 31.81 60
7.746 56.68 73 40.43 60
0.206 47.46 79 40.80 66
0.526 52.58 73 41.27 60
0.538 L2 48.19 73 31.18 60
2.546 47.54 73 35.52 60
7.770 56.67 73 39.04 60
SCOPE PLOTS:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 3 of 4

Figure 3: L1 Figure 4: L2
RBW 9 kHz RBW 9 kHz
MT 1 s MT 1 s
Att 20 dB PREAMP OFF Att 20 dB PREAMP OFF

FREQUENCY 7.7460000 MHz FREQUENCY 7.7700000 MHz


QPK 56.68 dBµV (57.5 7.746000 MHz) QPK 56.67 dBµV (57.5 7.746000 MHz)
AV 40.43 dBµV (48.2 510.0000 kHz) AV 39.04 dBµV (48.2 510.0000 kHz)
TDF TDF

0 10 20 30 40 50 60 70 80 6DB 0 10 20 30 40 50 60 70 80 6DB
AC AC

Marker 1 [T1 ] Marker 1 [T1 ]


60.90 dBµV 60.23 dBµV
7.746000000 MHz 7.770000000 MHz
dBµV 1 MHz 10 MHz dBµV 1 MHz 10 MHz
90 90
A
80 C2 QP A
80 C2 QP
70 C2 AV
A 70 C2 AV
A
1 PK 1 1 PK 1
MAXH 60 MAXH 60
50 50
40 TDF 40 TDF
30 30
20 20
10 6DB 10 6DB
AC AC
150 kHz 30 MHz 150 kHz 30 MHz

Date: 17.AUG.2012 10:53:14 Date: 17.AUG.2012 10:55:37

DT330

Freq. Limits Limits


Phase QP AV
(MHz) (dBμV) (dBμV)
0.510 54.85 73 48.17 60
0.534 52.83 73 37.06 60
1.942 L1 48.64 73 36.89 60
2.122 47.03 73 29.05 60
7.922 56.67 73 39.04 60
0.510 54.08 73 47.30 66
0.534 52.05 73 36.46 60
1.126 L2 48.09 73 39.10 60
1.866 47.04 73 32.73 60
7.918 56.16 73 37.73 60
SCOPE PLOTS:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 4 of 4

Figure 5: L1 Figure 6: L2
RBW 9 kHz RBW 9 kHz
MT 1 s MT 1 s
Att 20 dB PREAMP OFF Att 20 dB PREAMP OFF

FREQUENCY 7.9220000 MHz FREQUENCY 7.9180000 MHz


QPK 56.69 dBµV (57.5 7.746000 MHz) QPK 56.16 dBµV (57.5 7.746000 MHz)
AV 37.94 dBµV (48.2 510.0000 kHz) AV 37.73 dBµV (48.2 510.0000 kHz)
TDF TDF

0 10 20 30 40 50 60 70 80 6DB 0 10 20 30 40 50 60 70 80 6DB
AC AC

Marker 1 [T1 ] Marker 1 [T1 ]


61.28 dBµV 60.53 dBµV
7.922000000 MHz 7.918000000 MHz
dBµV 1 MHz 10 MHz dBµV 1 MHz 10 MHz
90 90
A
80 C2 QP A
80 C2 QP
70 C2 AV
A 70 C2 AV
A
1 PK 1 1 PK 1
MAXH 60 MAXH 60
50 50
40 TDF 40 TDF
30 30
20 20
10 6DB 10 6DB
AC AC
150 kHz 30 MHz 150 kHz 30 MHz

Date: 17.AUG.2012 10:58:20 Date: 17.AUG.2012 10:59:33

VIII. CRITARIA:
The measured noise shall be at least 6dB below limits

IX. DETERMINE:
V PASS FAIL

Tested By:
Date: 08/17/2012
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 1 of 4

Conducted Susceptibility Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
IEC 61326-1-6.2:2006

IV. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 CONDUCTED FRANKONIA 2012/07/25 2013/07/24
CIT-10/75
IMMUNITY
2 FRANKONIA CDN M2+M3 2011/11/07 2012/11/06
TEST SYSTEM
3 CLAMP (FOR SCFAFFNER KEMZ 801 2011/11/07 2011/11/06
CS TEST)
4 6 dΒ Bird 75-A-FFN-06 2011/11/04 2012/11/03
ATTENUATOR

V. ASSOCIATED PERIPHERALS
Item Name Manufacturer Model Serial No. Description
1 HMI DELTA DOP-B10S411 B10S4116T216B001 Communication
2 MULTIMETER APPA APPA101 N/A N/A

VI. CONDITION:
Input voltage: 110 VAC
Environment temperature: 24.1 ℃, humidity: 53 %RH
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 2 of 4

Line length: Power line: 30 cm ,Communication line RS-485: 3 m ,I/O line: 3 m


Setup value: Setup value:
PWR RS-485

Laboratory: 3F

VII. SETUP:
Figure 1:Setup photo-Power line Figure 2:Setup photo
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 3 of 4

Figure 3:Setup -Communication line Figure 4:Setup photo

VIII. RESULT:
Frequency range: 0.15~80MHz, Field strength: 3V/M, Modulation (AM 1kHz 80%)
-3
Sweep Rate: ≦ 1.5×10 decades/s , Step size : ≦1% of preceding frequency value , Dwell time: 2.9Sec
Frequency Range(MHz) Test Line Test Result
015~80 Power Line A
015~80 Communication Line(RS-485 unshielded) A
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

IX. CRITARIA:
Normal performance within the specification.

X. DETERMINE:
V PASS FAIL
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 4 of 4

Tested By:
Date: 08/17/2012
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 1 of 3

EFT/Burst Immunity Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
IEC 61326-1-6.2:2006

IV. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 EMC Test
EMC PARTNER TRA1000 2011/11/04 2012/11/03
System
2 Capacitive N/A N/A N/A N/A
coupling clamp

V. ASSOCIATED PERIPHERALS
Item Name Manufacturer Model Serial No. Description
1 HMI DELTA DOP-B10S411 B10S4116T216B001 Communication
2 MULTIMETER FLUKE FLUKE 45 N/A N/A

VI. CONDITION:
Input voltage: 110 VAC
Environment temperature: 26 ℃, humidity: 60 %RH
Line length: Power line: 50 cm(18AWG) ,RS-485: 3 m ,I/O line: 3 m
Coupling/decoupling network
EFT V-peak: Power line:1000~3000V; Communication line: 1000~2000 V
Polarity +/-:POS/NEG
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 2 of 3

Burst period(Repetition): 300ms±20%


Burst duration: 15ms±20%
Spike frequency:5KHz
Test-time:60sec
Random spikes: OFF
EFT trigger: AUTO
Burst Syncro: OFF
The relation with wave and power: Asynchronous
Laboratory: 3F

VII. SETUP:
Figure 1:Setup photo-Power line Figure 2:Setup photo

Figure 3:Setup -Communication line

N/A
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 3 of 3

VIII. RESULT:
Pulse:5/50ns
repetition Rate:5KHz below and equal 4.0Kv
Test time:1min/each condition
\Voltage\Polarity 2KV 3KV
\Test point\Mode\Result + - + -
L A A A A

Power Line N A A A A

L+N A A B B
\Voltage\Polarity 1KV 2KV
\Test point\Mode\Result + - + -
RS-485 A A A A
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.
“--” means the test could not be carried out.
IX. CRITARIA:
Temporary degradation or loss of function or performance that is self-recoverable.

X. DETERMINE:
V PASS FAIL

Tested By:
Date: 08/17/2012
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 1 of 3

Electrostatic Discharge Immunity Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
IEC 61326-1-6.2:2006

IV. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 ESD Noiseken ESS-2000 2011/10/26 2012/10/25
SIMULATOR

V. ASSOCIATED PERIPHERALS
Item Name Manufacturer Model Serial No. Description
1 HMI DELTA DOP-B10S411 B10S4116T216B001 Communication
2 MULTIMETER FLUKE FLUKE 45 N/A N/A

VI. CONDITION:
Input voltage: 110 VAC
Environment temperature: 25.7 ℃, humidity: 58 %RH ,Pressure: 1048 mbar
Line length: Power line(18 AWG): 50 cm ,
Communication line RS-485 unshielded : 3 m
I/O line: 3 m
Electrostatic discharge: Air discharge, Contact discharge
Polarity of output voltage:Positive and negative
Mode of operation:Single discharge
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 2 of 3

Discharge times of single point:On pre-selected points at least ten single discharge
The duration between successive discharges:1 s.
Laboratory: 3F

VII. SETUP:
Figure 1:Setup Figure 2:Setup photo

Figure 3:Test point Figure 4:Test point

VIII. RESULT:
Energy-Storage Capacitor: 150pF Discharge Resistor :330Ω Discharge Times :10 times/ each
condition
\Discharge Mode Contact Discharge Air discharge
\ESD Voltage 4KV 8KV
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 3 of 3

\Polarity + - + -
Result A A A A
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

CRITARIA:
Temporary degradation or loss of function or performance that is self-recoverable.

IX. DETERMINE:
V PASS FAIL

Tested By:
Date: 08/17/2012
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 1 of 4

Radiated Emission Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
Delta Spec. : EMR-Q026-5.3
Safety Spec. : IEC61326(2005),IEC61000-6-2

IV. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 Biconilog antenna Electronics Testing Center (ETC) Equipment
2 Receiver
3 Spectrum analyzer

V. CONDITION:
Input voltage: 110 VAC
Environment temperature: 25 ℃, humidity: 61 %RH
Carrier frequency: Maximum carrier frequency
Direction of antenna:Vertical/Horizontal
Height of antenna:1~4m
Laboratory: ETC B1
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 2 of 4

VI. SETUP:
Figure 1:setup photo

VII. RESULT:
水平:
EUT : Model : DT330VA-0200 Status :

Condition : Horizontal Date : 2012/08/31 Temp. : 25℃ Humi. : 61%


QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 3 of 4

No. Frequency Reading Detector Corrected Result Limit Margin

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB)

1 54.8718 21.61 peak 12.78 34.39 50.00 -15.61


2 70.4167 22.30 peak 10.81 33.11 50.00 -16.89
3 163.6860 17.86 peak 14.60 32.46 50.00 -17.54
4 253.8462 19.01 peak 13.50 32.51 57.00 -24.49
5 351.7788 17.93 peak 16.46 34.39 57.00 -22.61
6 902.0673 20.89 peak 26.02 46.91 57.00 -10.09
Test Request: CNS13438-A

垂直:
EUT : Model : DT330VA-0200 Status :

Condition : Horizontal Date : 2012/08/31 Temp. : 25℃ Humi. : 61%

No. Frequency Reading Detector Corrected Result Limit Margin

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB)

1 33.1090 29.76 peak 13.31 43.07 50.00 -6.93


2 64.1987 27.96 peak 11.63 39.59 50.00 -10.41
3 173.0128 18.40 peak 14.52 32.92 50.00 -17.08
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 4 of 4

4 246.0737 19.97 peak 13.31 33.28 57.00 -23.72


5 460.5930 17.72 peak 19.16 36.88 57.00 -20.12
6 911.3942 18.68 peak 26.09 44.77 57.00 -12.23

測試工程師:
備註:
1. Result = Level + Factor
2. Margin = Result - Limit
3. Factor = 天線因子 + 信號電纜損失 – 放大器增益(有使用時)
4. 接收天線調整高度為 1~4m
5. 表中如有: 〝----〞, 表示 QP Result 小於 AVG Limit,不必再使用平均值檢波器測量
〝***〞, 表示干擾值太小,故不予記錄
〝#〞, 表示干擾值很低,記錄其峰值
6. 量測不準確度: ±4.6dB (30MHz≦f<300MHz)
±4.2dB (300MHz≦f<1eHz)
±4.1dB (1eHz≦f≦1VeHz)

6.

VIII. CRITARIA:
The measured noise shall be at least 6dB below limits

IX. DETERMINE:
V PASS FAIL

Tested By:
Date: 2012/08/31
QE Record
Subject: ICD TEST REPORT Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 1 of 4

Radiated Susceptibility Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
Delta Spec. : EMR-Q007-5.6
Safety Spec. : IEC 61326-1(2005), IEC61000-4-3&IEC61000-6-2

IV. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 SMGL generator Electronics Testing Center (ETC) Equipment
2 Amplifier
3 GTEM CELL
4 Antenna

V. ASSOCIATED PERIPHERALS
Item Name Manufacturer Model Serial No. Description
1 PLC DELTA DVP32EH00T2-L 32EHR-L2T8250003 Control

VI. CONDITION:
Input voltage: 110 VAC
Environment: temperature: 20 ℃, humidity: 60 %RH
Carrier frequency: Maximum carrier frequency
Laboratory: Electronics Testing Center (ETC)
QE Record
Subject: ICD TEST REPORT Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 2 of 4

VII. SETUP:
Figure 1. setup photo Ver. X axis Figure 2. setup photo Hor. X axis

Figure 3. setup photo Ver. Y axis Figure 4. setup photo Hor. Y axis

Figure 5. setup photo Ver. Z axis Figure 6. setup photo Hor. Z axis
QE Record
Subject: ICD TEST REPORT Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 3 of 4

VIII. RESULT:
Frequency
:80 MHz ~ 2700 MHz Field Strength :10 V/m Modulation (AM 1kHz 80%)
Range
Sweep -3
:≤ 1.5×10 decades/s Step Size :≤ 1 % of preceding frequency value Dwell Time :2.9 s
Rate
Frequency Range (MHz) Test Axis Polarization of Device Test Result

80~2700 X-axis Ver. A


80~2700 X-axis Hor. A
80~2700 Y-axis Ver. A
80~2700 Y-axis Hor. A
80~2700 Z-axis Ver. A
80~2700 Z-axis Hor. A

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.
“--” means the test could not be carried out.
QE Record
Subject: ICD TEST REPORT Rev.: 00
Project Code: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/31 Page 4 of 4

IX. CRITARIA:
Normal performance within the specification.

X. DETERMINE:
V PASS FAIL

Tested By:
Date: 2012/08/31
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 1 of 3

High-energy Surge Immunity Test


I. MODEL:
Model name Serial number
DT330VA-0200 33VA0200T2290010

II. VERSIONS
Hardware versions:DISP BD:2945209900 / PWR BD:2945207200 /
OPTION BD:2945210000 / PULSE-V BD:2945209001
Firmware versions: 1.30

III. STANDARD:
IEC 61326-1-6.2:2006

IV. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 TRANSIENT
EMC Test System EMC PARTNER 2011/11/04 2012/11/03
1000
2 DN-LF2 DN-LF2
EMC-PARTNER 2011/09/05 2012/09/04
CDN-KIT1000 CDN-KIT1000
3 CN-U CN-U
EMC-PARTNER 2011/09/05 2012/09/04
CDN-KIT1000 CDN-KIT1000

V. ASSOCIATED PERIPHERALS
Item Name Manufacturer Model Serial No. Description
1 HMI DELTA DOP-B10S411 B10S4116T216B001 Communication
2 MULTIMETER FLUKE FLUKE 45 N/A N/A

VI. CONDITION:
Input voltage: 110 VAC
Environment temperature: 26 ℃, humidity: 52 %RH
Coupling/decoupling network
Line length: Power line(18 AWG): 50 cm ,Communication line RS-485 : 3 m,
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 2 of 3

Polarity +/-:POS/NEG
Test-time:60sec
SURGE trigger: AUTO
The relation with wave and power: Asynchronous
Laboratory: 3F

VII. SETUP:
Figure 1:Setup photo-Power line Figure 2:Setup photo

Figure 3:Setup photo unshielded line Figure 4:Setup photo RS-485

VIII. RESULT:
Waveform: 1.2/50μs (8/20μs) Repetition rate: 60sec Times: 5time /each condition
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-120814H-01
Model Name: DT330VA-0200 Release Date: 2012/08/17 Page 3 of 3

\Phase
0° 90° 180° 270°
\Voltage\Mode\Polarity\Result

+ A A A A
1KV L+N(DM)
- A A A A

+ A A A A
2KV L+N(DM)
- A A A A

SIGNAL LINE 90°

+ A
1KV RS-485
- A

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual
restart or power off/power on.

IX. CRITARIA:
Temporary degradation or loss of function or performance that is self-recoverable.

X. DETERMINE:
V PASS FAIL

Tested By:
Date: 08/17/2012
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 1 of 4

Conducted Susceptibility Test


I. MODEL:
Model name Serial number
DT340RA-R111 34RAR111T1430004

II. STANDARD:
Safety Spec.: EN61000 Chapter 4-6, IEC61131-2 Chapter 9.10
Delta Spec.: EMR-Q007 Chapter5.12

III. EQUIPMENTS LIST FOR TESTING


Item Name Manufacturer Model Calibration Date Recommended
Racal. Date
1 CONDUCTED FRANKONIA CIT-10/75 2011/07/25 2012/07/24
IMMUNITY CDN M2+M3 2010/02/08 2011/02/07
2 FRANKONIA
TEST SYSTEM
3 CLAMP (FOR SCFAFFNER KEMZ 801 2011/02/09 2012/02/08
CS TEST)
4 6 dΒ Bird 75-A-FFN-06 2011/01/31 2012/01/30
ATTENUATOR

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 53 %RH
Setup value:

Laboratory: 3F Lab., Taiyuan


QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 2 of 4

V. SETUP:
Figure 1:Setup photo

Figure 2: Setup -Power line Figure 3: Setup -Signal line

DT340
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 3 of 4

VI. RESULT:
Frequency range: 0.15~80MHz, Field strength: 3V/M, Modulation (AM 1kHz 80%)
-3
Sweep Rate: ≦ 1.5×10 decades/s , Step size : ≦1% of preceding frequency value , Dwell time: 2.9Sec
Frequency Range Test Line Test Result
150KHz~80MHz Power line A
150KHz~80MHz Signal line A

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Normal performance within the specification.

VIII. DETERMINE:
V PASS FAIL

Tested By:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 4 of 4

Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 1 of 3

EFT/Burst Immunity Test


I. MODEL:
Model name Serial number
DT340RA-R111 34RAR111T1430004

II. STANDARD:
EN61000-4-4, (2004-07)
EN61131-2, (2007-07), Chapter 9.8

III. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 EMC test System EMC PARTNER TRA2000IN6 2011/09/06 2012/09/05
Capacitive
2 N/A N/A N/A N/A
coupling clamp

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 49 %RH
Coupling/decoupling network
EFT V-peak:2000V
Polarity +/-:POS/NEG
Burst period(Repetition): 300ms±20%
Burst duration: 15ms±20%
Spike frequency:5KHz
Test-time:60sec
Random spikes: OFF
EFT trigger: AUTO
Burst Syncro: ON
The relation with wave and power: Asynchronous
Line length: Power line(18AWG): 30 cm
Communication lin(24AWG): 3 m
Laboratory: 3F Lab., Taiyuan
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 2 of 3

V. SETUP:
DT340RA-R111
Figure 1:Setup photo Figure 2:Power line

Figure 3:Communication line

VI. RESULT:
Pulse:5/50ns
repetition Rate:5KHz below and Test time:1min/each condition
\Voltage\Polarity 1KV 2KV
\Test point\Mode\Result + - + -
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-23 Page 3 of 3

L
Power Line N A A A A
L-N
Communication line RS-485 A A -- --
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Temporary degradation or loss of function or performance that is self-recoverable.

VIII. DETERMINE:
V PASS FAIL

Tested By:
Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-10 Page 1 of 5

Radiated Emission Test


I. MODEL:
Model name Serial number
DT340RA-R111 34RAR111T1430004

II. STANDARD:
Delta Spec. : EMR-Q007-5.3
Safety Spec. : EN 55011, EN61131-2

III. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 Biconilog antenna Electronics Testing Center (ETC) Equipment
2 Receiver
3 Spectrum analyzer

IV. CONDITION:
EUT Power: 220 V AC ;frequency: 50/60 Hz
Environment temperature: 20 ℃, humidity: 60 %RH
Carrier frequency: Maximum carrier frequency
Direction of antenna:Vertical/Horizontal
Height of antenna:1~4m
Laboratory: ETC CHMBER 4
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-10 Page 2 of 5

V. SETUP:
Figure 1:setup
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-10 Page 3 of 5

VI. RESULT:
DT340
Horizontal:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 68.8622 21.69 peak 10.26 31.95 50.00 -18.05


2 99.9518 22.11 peak 9.29 31.40 50.00 -18.60
3 168.3494 20.24 peak 13.70 33.94 50.00 -16.06
4 191.6666 21.33 peak 11.00 32.33 50.00 -17.67
5 250.7372 21.40 peak 11.91 33.31 57.00 -23.69
6 396.8590 22.49 peak 15.63 38.12 57.00 -18.88
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-10 Page 4 of 5

Vertical:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 56.4263 26.12 peak 11.93 38.05 50.00 -11.95


2 98.3974 22.99 peak 9.04 32.03 50.00 -17.97
3 169.9038 19.18 peak 13.79 32.97 50.00 -17.03
4 191.6667 21.91 peak 11.00 32.91 50.00 -17.09
5 246.0737 24.23 peak 11.82 36.05 57.00 -20.95
6 396.8590 19.12 peak 15.63 34.75 57.00 -22.25
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-02
Model Name: DT340 Release Date: 2011-11-10 Page 5 of 5

Test Engineer:XYZ
備註X
1. Result = Level + Factor
2. Margin = Result - Limit
3. Factor = 天線因子 + 信號電纜損失 – 放大器增益(有使用時)
4. 接收天線調整高度為 1~4m
5. 表中如有: 〝----〞, 表示 QP Result 小於 AVG Limit,不必再使用平均值檢波器測量
〝***〞, 表示干擾值太小,故不予記錄
〝#〞, 表示干擾值很低,記錄其峰值
6. 量測不準確度: ±4.6dB (30MHz≦fZ300MHz)
±4.2dB (300MHz≦fZ1eHz)
±4.1dB (1eHz≦f≦1VeHz)

VII. CRITARIA:
The measured noise shall be below limits

VIII. DETERMINE:
V PASS FAIL

Tested By: Adun.Lin_


Date: _2011/11/10_
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 1 of 4

Conducted Susceptibility Test


I. MODEL:
Model name Serial number
DT360LA-L222 36LAL222T1430003

II. STANDARD:
Safety Spec.: EN61000 Chapter 4-6, IEC61131-2 Chapter 9.10
Delta Spec.: EMR-Q007 Chapter5.12

III. EQUIPMENTS LIST FOR TESTING


Item Name Manufacturer Model Calibration Date Recommended
Racal. Date
1 CONDUCTED FRANKONIA CIT-10/75 2011/07/25 2012/07/24
IMMUNITY CDN M2+M3 2010/02/08 2011/02/07
2 FRANKONIA
TEST SYSTEM
3 CLAMP (FOR SCFAFFNER KEMZ 801 2011/02/09 2012/02/08
CS TEST)
4 6 dΒ Bird 75-A-FFN-06 2011/01/31 2012/01/30
ATTENUATOR

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 53 %RH
Setup value:

Laboratory: 3F Lab., Taiyuan


QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 2 of 4

V. SETUP:
Figure 1:Setup photo

Figure 2: Setup -Power line Figure 3: Setup -Signal line

DT360
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 3 of 4

VI. RESULT:
Frequency range: 0.15~80MHz, Field strength: 3V/M, Modulation (AM 1kHz 80%)
-3
Sweep Rate: ≦ 1.5×10 decades/s , Step size : ≦1% of preceding frequency value , Dwell time: 2.9Sec
Frequency Range Test Line Test Result
150KHz~80MHz Power line A
150KHz~80MHz Signal line A

Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Normal performance within the specification.

VIII. DETERMINE:
V PASS FAIL

Tested By:
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 4 of 4

Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 1 of 3

EFT/Burst Immunity Test


I. MODEL:
Model name Serial number
DT360LA-L222 36LAL222T1430003

II. STANDARD:
EN61000-4-4, (2004-07)
EN61131-2, (2007-07), Chapter 9.8

III. EQUIPMENTS LIST FOR TESTING


Item Recommended
Name Manufacturer Model Calibration Date
Racal. Date
1 EMC test System EMC PARTNER TRA2000IN6 2011/09/06 2012/09/05
Capacitive
2 N/A N/A N/A N/A
coupling clamp

IV. CONDITION:
Input voltage: 220 Vac , Frequency: 60 HZ
Environment temperature: 21.1 ℃, humidity: 49 %RH
Coupling/decoupling network
EFT V-peak:2000V
Polarity +/-:POS/NEG
Burst period(Repetition): 300ms±20%
Burst duration: 15ms±20%
Spike frequency:5KHz
Test-time:60sec
Random spikes: OFF
EFT trigger: AUTO
Burst Syncro: ON
The relation with wave and power: Asynchronous
Line length: Power line(18AWG): 30 cm
Communication lin(24AWG): 3 m
Laboratory: 3F Lab., Taiyuan
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 2 of 3

V. SETUP:
DT360LA-L222
Figure 1:Setup photo Figure 2:Power line

Figure 3:Communication line

VI. RESULT:
Pulse:5/50ns
repetition Rate:5KHz below and Test time:1min/each condition
\Voltage\Polarity 1KV 2KV
\Test point\Mode\Result + - + -
QE Report
Subject: ICD Hardware Test Report Rev.: 01
Project Number: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-23 Page 3 of 3

L
Power Line N A A A A
L-N
Communication line RS-485 A A -- --
Note:
“A” means the EUT shall continue to operate as intended. No loss of function or
performance.
“B” means the EUT shall continue to operate as intended. Temporary degradation of
performance must be self-recoverable.
“C” means the EUT shall continue to operate as intended automatically, after manual restart
or power off/power on.

VII. CRITERIA:
Temporary degradation or loss of function or performance that is self-recoverable.

VIII. DETERMINE:
V PASS FAIL

Tested By:
Date: 2011/11/23
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-10 Page 1 of 5

Radiated Emission Test


I. MODEL:
Model name Serial number
DT360LA-L222 36LAL222T1430003

II. STANDARD:
Delta Spec. : EMR-Q007-5.3
Safety Spec. : EN 55011, EN61131-2

III. EQUIPMENT:
Item Description Cat # / Model # / ser # Cal due Date #/
Recommend recal. Date
1 Biconilog antenna Electronics Testing Center (ETC) Equipment
2 Receiver
3 Spectrum analyzer

IV. CONDITION:
EUT Power: 220 V AC ;frequency: 50/60 Hz
Environment temperature: 20 ℃, humidity: 60 %RH
Carrier frequency: Maximum carrier frequency
Direction of antenna:Vertical/Horizontal
Height of antenna:1~4m
Laboratory: ETC CHMBER 4
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-10 Page 2 of 5

V. SETUP:
Figure 1:setup
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-10 Page 3 of 5

VI. RESULT:
DT360
Horizontal:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 132.5961 22.35 peak 12.83 35.18 50.00 -14.82


2 165.2403 20.55 peak 13.51 34.06 50.00 -15.94
3 228.9744 26.53 peak 11.37 37.90 50.00 -12.10
4 288.0448 20.75 peak 13.16 33.91 57.00 -23.09
5 396.8590 22.39 peak 15.63 38.02 57.00 -18.98
6 594.2788 22.38 peak 19.21 41.59 57.00 -15.41
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-10 Page 4 of 5

Vertical:

No. Frequency Reading Detector Corrected Result Limit Margin Height Degree Comment

(MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) (cm) (°)

1 37.7724 26.24 peak 12.87 39.11 50.00 -10.89


2 98.3974 22.09 peak 9.04 31.13 50.00 -18.87
3 166.7950 19.52 peak 13.61 33.13 50.00 -16.87
4 235.1923 22.61 peak 11.56 34.17 57.00 -22.83
5 288.0450 20.89 peak 13.16 34.05 57.00 -22.95
6 396.8590 20.46 peak 15.63 36.09 57.00 -20.91
QE Report
Subject: ICD Hardware Test Report Rev.: 00
Project Code: Doc. No.: QE-I-110812H-03
Model Name: DT360 Release Date: 2011-11-10 Page 5 of 5

Test Engineer:XYZ
備註X
1. Result = Level + Factor
2. Margin = Result - Limit
3. Factor = 天線因子 + 信號電纜損失 – 放大器增益(有使用時)
4. 接收天線調整高度為 1~4m
5. 表中如有: 〝----〞, 表示 QP Result 小於 AVG Limit,不必再使用平均值檢波器測量
〝***〞, 表示干擾值太小,故不予記錄
〝#〞, 表示干擾值很低,記錄其峰值
6. 量測不準確度: ±4.6dB (30MHz≦fZ300MHz)
±4.2dB (300MHz≦fZ1eHz)
±4.1dB (1eHz≦f≦1VeHz)

VII. CRITARIA:
The measured noise shall be below limits

VIII. DETERMINE:
V PASS FAIL

Tested By: Adun.Lin_


Date: _2011/11/10_