You are on page 1of 1

Outdoor Dual-band Combiner

CM-DW2-ODxG, CM-DW2D-ODxG (x=1, 2, 3 or 4, Preconfigured DC-pass)


Band 1:1710-1880MHz Band 2:1920-2170MHz

 Co-siting purpose for feeder sharing


 Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
 High isolation-minimizes interference
 High power handling and low loss – maximizes system performance
 Built-in lightning protection
 Available as a single unit or double units
Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications
1710-1880 1920-2170
Insertion Loss (dB) ≤0.3
Isolation between Ports (dB) ≥50
Return Loss (dB) ≥20
Maximum Input Power per Port (W) 250
Intermodulation Products (dBc) ≤-155@2x43dBm
Impedance (Ω) 50

Mechanical Specifications
Parameters Specifications
Dimensions, LxWxH (excluding connectors) Single Unit 210x124x49 / 7.6x4.9x1.9
(mm) / (in) Double Units 210x124x124 / 7.6x4.9x4.9
Single Unit 1.9 / 4.2
Weight (including connectors) (kg) / (lb)
Double Units 3.9 / 8.6
Color Light Grey
RF Connectors 7/16 DIN-Female
Mounting Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Operating Temperature Range (°C) -40 to +65
Operational Humidity (%) ≤95
Environmental Class IP67
Single Unit 415x200x130 / 16.3x7.9x5.1
Shipping Dimensions, LxWxH (mm) / (in)
Double Units 415x200x195 / 16.3x7.9x7.7
Single Unit 2.9 / 6.3
Shipping Weight (kg) / (lb)
Double Units 5.4 / 11.9
Lightning Protection Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information Block Diagram


Single Unit Double Unit Port 3
DC Bypass Optional
Model Number Model Number
CM-DW2-OD1G CM-DW2D-OD1G No DC Bypass
CM-DW2-OD2G CM-DW2D-OD2G DC Bypass @1710-1880
DC/AISG Bypass

CM-DW2-OD3G CM-DW2D-OD3G DC Bypass @1920-2170


DC/AISG Bypass

CM-DW2-OD4G CM-DW2D-OD4G Full DC Bypass

Port1 Port 2
1710-1880 1920-2170

Example: View of Single Unit CM-DW2-OD4G

© Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering. Page 1 of 1
Specifications may differ depending on region and customers’ requirements.
DS-Control:3-0-0 / 0116