Professional Documents
Culture Documents
Basket TB 0078....
Basket TB 0078....
Date of manufacture: -
If this the first examination after installation or after Yes If the answer to the question on the left is yes, has the Yes
assembly at a new site or location? No x equipment been installed correctly? No
Identification of any part found to have a defect which is or could become a danger to
persons and a description of the defect: (if none state none) none
Particulars of any repair, renewal or alteration required to remedy the defect identified
above:
A visual examination for general condition and a magnetic particle inspection was carried out on the lifting point welds of the above mentioned
equipment. No cracks or defects indication were noted at the time of inspection
The undersigned, ABS inspector, hereby certify that the here above mentioned supply was thoroughly examined, and the above particulars are correct.
It’s to further certify that this lifting equipment complies in all respect with the appropriate provisions and is free from defects affecting safety.
In the case of any modification of the equipment which has not been agreed upon with us in writing, this certificate becomes invalid.
Examination of lifting equipment only- this does not include accessories or vehicle on which it is mounted.
Rev. 1 (02/06/2014)
ABS / INSPECTION REPORT – IR14