Accessories Range
Accessories components
Flashing components made to supplement the complete roof and COLOUR RANGE
wall systems Kingspan, are manufactured from coated galvanized Standard colours available according to Kingspan colour chart
metal sheets 1,250 mm wide maximum and up to 8,000 mm long Please contact Kingspan for special colour shades requirements
(the recommended length of flashing components is 6,000 mm).
Wall flashing
Corner and internal corner flashing
Panel joint strips
Panel junctions to adjoining buildings Corner flashings Head and Cill
Cill flashings
Openings flashing
Window, door and gate flashing
Louvers flashings
MATERIAL SPECIFICATION
Source material
Galvanized metal sheet with coating 1,250 mm wide maximum
(fully spread).
Metalsheet thickness
Standard thickness of 0.6 mm is available in standard colours,
other thicknesses are possible according to suppliers production Verge components
technology (0.5 mm, 0.6 mm, 0.75 mm, galvanized metalsheet
1 mm)
7.1.2
Rainwater
Accessories system
System components
Hanging gutter (gutter connections)
Downpipe (angular)
Gutter support
Outlet
Downpipe sleeve
Sill and spout elbow-pipe accessories (rivets, fasteners, caps,
sealant, stub nail)
7.1.3
Corner components,
Steel sheets, steel
Accessories in coils
Steel in coils
Rewinding is secured on Kingspan equipment
Delivery of the quantity according to the customer requirement
(maximal weight of one coil is 2 t depending on steel thickness)
Width of the coil is between 1,058 and 1,250 mm
Thickness of the steel is between 0.5 and 0.75 mm
Colour shades of the steel in PES coating available according to
the current standards
Other coating and colours available according to actual stock
situation
Coils are powered by protective foil on the exterior side
7.1.4
Accessories Tophats
Vertical tophats are used for overlap of the cross joint at horizontally
laid panels.
Max. length: 8 m
Materials
Zinc coated steel with final surface coating
Steel thickness:
Standard steel thickness 0.6 mm is delivered for Kingspan standard
colour shades
atypical tophats
7.1.5
Accessories Wall-Lite™
Application
Wall light panel KS1000 WL can be used for vertical and horizontal
cladding. Maximal span is determined by the static tables
calculation.
Materials
Polycarbonate chamber board, thickness 38 mm. Colour: clear. It
is possible to offer other colour shades according to actual stock
situation.
Construction
Modular width 1,000 mm
Weight: 4.7 kg / m2
Panel joint shape corresponds to the joint of panel KS1000 AWP
Thickness difference between panel KS1000 AWP and panel
KS1000 WL is solved by aluminium distance profiles
Distance profiles are available for thicknesses of following panels:
KS1000 AWP 60, 80, 100
Length: max. 6,000 mm
Exterior side is provided with UV filter.
Thermal characterictics - U value = 1.26 W / m2K
Light transmission
Transmission range is 55 % for clear colour. In case of other colour
shade, please contact Accessories department Kingspan.
7.1.6
KS1000 PC,
Accessories KS1000 PC Double Skin
Standard
cut back
= 175 m
m
The lower part of the rooflight panel is made with standard overlap
(cutback) 175 mm.
1,000 mm
333 mm 333 mm 333 mm
35 mm
D
d
7.1.7
Rooflight panels
Accessories HTL
Rooflight is an optimal appliance to enable daylight to the interior of the building. This applies
especially to longspan roofs, where skylights or rooflight panels are the only way to effectively
fulfill requirements of even daylight spread inside the building. Rooflight panels are laid at the roof
surface level. In case of rooflight panels there is no light loss compared to skylights (skylight support,
transversal skylight walls).
Standard length: max. 6,250 mm (including overlap 250 mm) * Fire performance was tested according czech standards. For
more information about european standards please contact your
Width: 1,000 mm (polycarbonate)
local technical team.
Light transmission
Approximately 55 %
1,000 ± 3 mm
333.3 mm 333.3 mm
d
D
D = d + 35 mm
KS1000 RW/HTL
d U weight
[mm] [W / m2K] [kg]
25 1.639 5.9
32 1.470 6.6
1,000 ± 3 mm
250 mm 250 mm 250 mm
d
D
D = d + 34 mm
KS1000 FF/HTL
d U weight
[mm] [W / m2K] [kg]
25 1.639 5.9
32 1.470 6.6
7.1.8
Aluminium
Accessories programme
Aluminium products, which are very effective and easy for Different dimensions can be produced upon agreement.
installation with faultless functionality, can highlight the originality
High shape variability
of any building. Primary material used is aluminium sheet with
No standard shapes
final komaxit coating. This guarantees a high quality and life time
of the parts as well as a colour range according to the request of Upstands for RW and FF panel
a customer. Production to individual needs of a customer
Komaxit coating
Al louvres
The advantages of these products are shape variability and Finished product, no other completion works
possibility of any colour coating.
Technical parameters:
Louvers can be produced upon agreement in dimensions and
shapes according to individual needs of a customer, in max. length
up to 3,000 mm and width up to 1,500 mm.
Roof upstands
Aluminium Upstands allow trouble free sealing for installation on the
roof. As a final product it does not require any other finishing works.
7.1.9
Aluminium
Accessories programme
00 mm)
I (min. 5
650 mm
00 mm)
CB J (min. 3
mm)
(20-300
250 mm
d
H (0-300
mm)
)
530 mm
A (430;
7.1.10
Passage Piping
Accessories Packing
Dektite® Square
Pipe Collar
Suitable for the sealing of metall roofs and pipes.
Benefits:
Perfect sealing for wall and roof.
Thermal change in lengths of the pipes will not be disabled.
Fatigue fractures are impossible.
for pipes with ∅ Base Roof Pitch EJOPLAST cartridge EJOT COLORDRIL®
Reference Order Number
[mm] [mm] [°] [ml] Drilling screws pcs.
P23a DFE 0–35 0–35 99 × 99 0–60 80 8
P23b DFE 5–55 5–55 137 × 137 0–35 80 8
P23c DFE 50–70 50–70 178 × 178 0–35 80 12
P23d DFE 5–120 5–120 218 × 218 0–35 80 16
P23e DFE 110–170 110–170 284 × 284 0–35 80 20
P23f DFE 160–220 160–220 365 × 365 0–35 80 28
P23g DFE 160–300 160–300 453 × 453 0–35 310 32
P23h DFE 290–440 290–440 581 × 581 0–35 310 40
Dektite® Retrofit
Pipe Collar
Suitable for the sealing of pipes in bad reachable locations.
Benefits:
Ideal for the repair of already existing pipesystems .
7.1.11
Passage Piping
Accessories Packing
Remark:
For the installation of rectangular pipes you need to use rivets
and drilling screws. Potentially the pipe needs to be drilled
through.
Dektite® Soaker
Pipe Collar
Suitable for the sealing of pipes with huge openings.
Benefits:
Ideal positioning because of the huge base.
Simple and safe installation.
Sealing of pipes and roofs in one working step. Prevention from
rainwater back pressure.
for pipes with ∅ Base Roof Pitch EJOPLAST cartridge EJOT COLORDRIL®
Reference Order Number
[mm] [mm] [°] [ml] Drilling screws pcs.
P23i DF 602 75–155 410 × 360 0–60 80 30
P23j DF 603 114–254 485 × 460 0–60 80 36
P23k DF 605 254–406 708 × 635 0–60 310 52
P23l DF 606 380–610 1 415 × 905 0–60 310 96
7.1.12
Fastening & Sealing
Accessories Components
Ref. Description
P01 Self-drilling or self-tapping screw with sealing washer, callot and plastic cap – to be determined by the designer (for panel/construction –
crown locations) (see chapter Fixing srews)
P02 Self-drilling or self-tapping screw (with thread under head) with sealing washer, plastic cap – to be determined by the designer (for panel/
construction – crown locations) (see chapter Fixing srews)
P03 Self-drilling screw with groove under the head and sealing washer – to be determined by the designer (for sheet steel/sheet steel)
P04 Self-drilling or self-tapping screw (with thread under head) with sealing washer (plastic cap) – to be determined by the designer (for
panel/construction – valley locations) (see chapter Fixing srews)
P06 Self-drilling or self-tapping screw with countersunk head – to be determined by the designer (for panel/construction)
P07 Single side rivet 4 × 10 AI/E (for sheet steel/sheet steel – inside)
P08 Single side closed rivet 4.8 × 10 AI/E (for sheet steel/sheet steel – outside)
P09 Single side rivet 4.8 × 15.1 AI/E (for sheet steel/construction)
P10 Shank with a nut (2 pieces), sealing washer (2 pieces), callot (2 pieces) and plastic cap (As per eaves gutter specification)
P11 PU self-adhesive sealant tape – 10 × 2 – (10 mm expanded)
(to seal points between flashing components and panel with wave profile)
P12 PE profiled sealing filler „B“ (outside) – specify type of panel
P13 PE profiled sealing filler „A“ (inside) – specify type and thickness of panel
P14 PE self-adhesive sealant tape – 9 × 3 mm (Under flashing components)
P15 PVC self-adhesive sealant tape – 9 × 6 mm (to panel side lap)
P16 PE self-adhesive sealant tape – 20 × 3 mm (for panel overlap and flashing components)
P17 PE self-adhesive sealant tape – 20 × 5 mm (between panel and structure)
P18 PU self-adhesive sealant tape – 20 × 4 – (20 mm expanded) (to seal joints between panel and wall, concrete or dilatation)
P19 PE self-adhesive sealant tape – 30 × 8 mm or 2 pieces of tape – 20 × 5 mm (to seal winder joints)
P20 Butyl self-adhesive sealant tape – 15 × 5 mm or 15 × 6 mm (P20B) (for waterproof and vapor connections)
P21 Butyl self-adhesive sealant tape – 10 × 3 mm (for waterproof and vapor connections)
P22 Nailing screw with dowel – to be determined by the designer (see chapter Fixing srews)
P23 Passage piping packing – to be determined by the designer (see chapter Passage piping)
P24 Concrete anchorage – steel – to be determined by the designer
P25 Self-drilling screw with groove under the head and sealing washer – to be determined by the designer (for sheet/insulation/sheet – with
thickness 6–20 mm)
P26 PE profiled sealing filler (or piece of sealant tape P18) for side lap of panel FH and AWP – specify type of panel
P27 Laplox/Translap stitching screw 9 × 16 – to be determined by the designer (for the connection of roof panel – HTL, PC
and PC Double Skin)
P28 Galvanised self-drilling screw and plate washer – to be determined by the designer (for fixing of the membrane coated metal to panels)
P29 Butyl self-adhesive sealant tape – 4 mm diameter (for waterproof and vapor connections)
P30 Nailing rivet – to be determined by the designer (for concrete, metal, wood, masonry)
P31 Nailing dowel with pre – assembled nail and thread for dismantling – to be determined by designer (for concrete, solid and hollow
masonry, atc.)
P32 Single side rivet TPR with sealing washer (for fixing panels and gutters)
P33 Fab-Lok stainless single side screw (for fixing KS1000 TOP-DEK to cold rolled purlins)
P34 Self-tapping screw with plate – to be determined by the designer (for fixing the plastic spacers profile under the roof panels HTL, PC and
PC Double Skin)
P35 Insulating pipe ARMAFLEX AC – to be determined by the designer (for the expansion joint)
P37 Self-drilling screw with drill washer – to be determined by the designer (for the fixing roof panel TOP-DEK or XM, XB or XG)
P38 Self-tapping or self-drilling screw and plate washer – to be determined by the designer (for the fixing flat roof – panel/construction)
P39 Nailing spike and sealing washer – to be determined by the designer (for the fixing panel/concrete)
P40 PE profiled sealing according to thickness of the AWP panel – to be determined by the designer (under WL panel)
P41 Butyl self-adhesive sealant tape – 22 × 1.5 mm (for waterproof and vapor connections)
Note: Index “p” indicates bigger diameter of sealing washer for applications as below:
∅ 19 mm for KS1000 PC or PC Double Skin fixing system
∅ 22 mm for KS1000 FR, FH, FA and FF fixing system
∅ 29 mm for KS1000 HTL (in position valley)
7.1.13
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15 α 15 α = specify roofslope (° or %)
K101 110 110 max. length = 6,000 mm
1
1,000
°
121
varies for RW, FF, TOP-DEK (SR) panels
1
K102 46 indication of roof panel type required
1–1 34 max. length = 1,000 mm
1 21°
cut-out panel profile
α
300 300 α = specify roofslope (° or %)
K103a
max. length = 6,000 mm
12 12
30 30
280
α
280
α = specify roofslope (° or %)
K103b 60°
max. length = 6,000 mm
15 15
120 120
20 20 α = specify roofslope (° or %)
K103c
160 180° − 2α − 8° 160 max. length = 6,000 mm
15 15
235 235
α = specify roofslope (° or %)
K103d
max. length = 6,000 mm
180° − 2α − 8°
15 15
15 α
80 α = specify roofslope (° or %)
K104 60
max. length = 6,000 mm
15
7.2.14
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
X
X = specify dimension
165°
K105
20 max. length = 6,000 mm
15 20
5
15
60
K106 max. length = 6,000 mm
60
15
90
K107 45 120° max. length = 6,000 mm
15
15 α
25
α = specify roofslope (° or %)
K108 d+40 d = specify panel insulation thickness
max. length = 6,000 mm
15
40 15 α
α = specify roofslope (° or %)
K109 60 max. length = 6,000 mm
15
80
α 15
α
°+
50
120
α = specify roofslope (° or %)
°
150
15
7.2.15
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
45°
250
15
15
100
K112 max. length = 6,000 mm
100
15
15
30
20
70 20 30
15
10
45°
200
α = specify roofslope (° or %)
K114
max. length = 6,000 mm
α
250
15
7.2.16
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
45°
200
α = specify roofslope (° or %)
K115
max. length = 6,000 mm
α
250
15
30
d = specify panel insulation thickness
K117 d
max. length = 6,000 mm
30
60°
45°
10
135°
50
K121 40 40 max. length = 6,000 mm
350 350
15 15
15 15
75 75
K122 40 40 max. length = 6,000 mm
50
7.2.17
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
° 92
K123 65 45 max. length = 6,000 mm
30 63
15 15
15 15
K124 max. length = 6,000 mm
90
°
60
95
D+20
D = specify wall panel thickness
K125 60
max. length = 6,000 mm
65
45°
30
15
35
α
15
°+
α
90
+
0°
90 10
18 35
(89)
160°
85
10
0°
(84)
175 (173)
A
K127 B B β see gutter system specification
β
15 15
7.2.18
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
45°
200
K128 max. length = 6,000 mm
120
°
235
35
15
270
−α
0°
10
90
15
160°
α = specify roofslope (° or %)
K129 85 max. length = 6,000 mm
10
0°
50
75
15
D + (X + d) + 55
97
°
°
93
80 90
15
160°
75
15
7.2.19
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
270
15
0°
10
90
160°
50
75
15
25
K132 30 max. length = 6,000 mm
25
67
°
95
18
30 15
7.2.20
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
∅D
15
45°
350
15
55
30
d
α = specify roofslope (° or %)
55
K139 d = specify insulation core thickness
α max. length = 6,000 mm
250
15
50
°
45 120
X
15 X = specify dimension
°
90
15
7.2.21
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
10
45°
250
15
200
15
15
100
D = specify wall panel thickness
K143
°
93
53
D = specify wall panel thickness
K144 D(d) + 2 d = specify insulation core thickness
15 max. length = 6,000 mm
50
35
5°
15
K146 15 20 60 max. length = 6,000 mm
50
7.2.22
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
20
15
35
K149 15 30 30 15 max. length = 6,000 mm
40 40
15 15
K150 30 15 15 30 max. length = 6,000 mm
135
° 30
95
°
20 40
K151 max. length = 6,000 mm
45° 50
15
15
7.2.23
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
20 15
20
K155 45° max. length = 6,000 mm
70
15
3°
d + 100
D + 20
45°
40
15
25 15
20
°
50 45°
15
°
93
n.
mi
15 X = specify dimension
K161 X + 30
45° max. length = 6,000 mm
40
15
7.2.24
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
100
K162 20 max. length = 6,000 mm
3°
9 D = specify wall panel thickness
n.
30
mi
35
K164 15 30 30 15 max. length = 6,000 mm
80 80
15
70
15
15
D = specify roof panel thickness
K167 D − 10
max. length = 6,000 mm
120 15
85
70
°+
α = specify roofslope (° or %)
α
K168
250
max. length = 6,000 mm
15
7.2.25
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
15 15
K170 50 13 20 20 50 max. length = 6,000 mm
°
5 ° 150 135
90
30
°+
α
15
15
15
70
34
°
°
K173 45° X−D+56 X = specify dimension
35 max. length = 6,000 mm
15
15
50
K174 max. length = 6,000 mm
15
50
7.2.26
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
max. length = 6,000 mm
X X assembled
24
K175b 15 26 15 X = specify dimension
15
26 1
Xmin = 35, Xmax = 90
Xstandard = 60
°.3
min
20 D + 53
60
D = specify wall panel thickness
K176
max. length = 6,000 mm
72
45°
30
15
33
35
D = specify wall panel thickness
K178 D
max. length = 6,000 mm
15
55
34
85
°
56
95
45
15
45°
7.2.27
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
90
30
K183 3 items per meter recommended
30
30
150
D = specify wall panel thickness
K184
max. length = 6,000 mm
°
95
D + 30
45°
35
15
35
K185 30 30 max. length = 6,000 mm
15 15
25 25
90°
90 90
K186 30 20 20 30 max. length = 6,000 mm
15 120° 120 15
°
15
30
20
20 D + 77
30
15
7.2.28
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
43
35
28 28
K191 30 30 max. length = 6,000 mm
30 20 20 30
135 °
° 60 60 135
100
K192 35
15 max. length = 6,000 mm
15 α
50
α = specify roofslope (° or %)
K193
max. length = 6,000 mm
100
15
36
85
°
K195
°
D(d), Y + 33
Y = specify dimension
15
max. length = 6,000 mm
45°
7.2.29
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
15 15 B
B = specify dimension
K199
40 max. length = 6,000 mm
15
50
° 127
127 °
K200 50 50 max. length = 6,000 mm
30 30
15 15
95
α = specify roofslope (° or %)
K201
max. length = 6,000 mm
α
240
15
7.2.30
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
15
70
50
45 °
120
d = specify roof panel insulation thickness
K203 15 d max. length = 6,000 mm
50
55
45° D
D = specify wall panel thickness
K204 100
max. length = 6,000 mm
15
90
90
30
90
90
_
30 3 items per meter recommended
K206
α = specify roofslope (° or %)
30
7.2.31
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
D + 165
α
15
120 120
D = specify wall panel thickness
K208 D − 30 D − 30
90° max. length = 6,000 mm
30 30
70
α
α = specify roofslope (° or %)
K209 65
max. length = 6,000 mm
15
100
D = specify wall panel thickness
°
K211
93
47
7.2.32
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
80
3°
X = specify dimension
9
n.
K213
mi
max. length = 6,000 mm
45° X + 30
35
15
15
K214 30 max. length = 6,000 mm
15
D + X + d + 85
97
°
°
93
80 90
30
160°
50
75
15
80 112
K216 0°
135
°
max. length = 6,000 mm
10
30 28
15 15
80
α 15
0° +α
50 12 d = specify roof panel insulation thickness
150°
15
7.2.33
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15
D = specify wall panel thickness
D + X + 15 d = specify insulation thickness
K218
135 X = specify dimension
°
15
20 max. length = 6,000 mm
30
d + 50
47
15
20 30
60 °
K220 135 max. length = 6,000 mm
60
15
°
D 135 15 D = specify wall panel thickness
K221 20 30 max. length = 6,000 mm
80
60°
15
°
15
93
°
80
K224 max. length = 6,000 mm
40
15
7.2.34
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
15 15
K225 max. length = 6,000 mm
140
20 3093
°
90
K226 max. length = 6,000 mm
5°
11
60
30
15
50
°
93
20
45
K227 max. length = 6,000 mm
60 45°
15
15 15
K228 30 20 20 30 max. length = 6,000 mm
135 40 °
° 135
15 α
60
20
30 28
7.2.35
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
100
°
95
D = specify wall panel thickness
K230
D + 40 max. length = 6,000 mm
60
20
30
15
100
°
95
65
45°
30
15
35 15
β
35
15
ε
90
K232 X* see gutter system specification
160°
85 10
0°
175
7.2.36
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
d (mm) A (mm)
80 30
15 100 44
A 120 58
161°
71°
K233 150 72
45
15
d = specify roof panel insulation
25
thickness FF
specify for roof light panel FF/GRP40 right
and left side lap
100
α
α = specify roofslope (° or %)
°+
90
250 + D
max. length = 6,000 mm
15
15 15
110 110 α = specify roofslope (° or %)
K235 α max. length = 6,000 mm
25
specify for roof panel RT
K236 40
max. length = 6,000 mm
25
VIEW-A
50
15
7.2.37
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
155
β = specify angle (° or %)
K238
220 max. length = 6,000 mm
15
35
25
β*
35
15
°
110
β*
59
170
450 21
15 ° 15
138
88
60
7.2.38
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
d (mm) A (mm)
60 20
80 28
5 ° 100 48
10 °
15
A 120 68
80
155°
K242
34
150 98
15
30 d = specify roof panel insulation
thickness RW
specify for roof light panel RW/GRP40
max. length = 6,000 mm
d (mm) A (mm)
60 20
80 30
100 50
A 15
120 70
50°
K243
36
5°
15 150 100
15
30
d = specify roof panel insulation thickness
RW
specify for roof light panel RW/GRP40
max. length = 6,000 mm
150°
40
A
60° 35
D = specify roof panel thickness
B = d + 62 135 15
K244 75 ° A = specify dimension
°
max. length = 6,000 mm
25
35 33
75
°
150°
40
A
35
D = specify roof panel thickness
60° 15
K245 135 A, C = specify dimensions
B = d + 85 °
max. length = 6,000 mm
C 15
30
135
°
45 45
K246 23 20 27 27 20 23 max. length = 6,000 mm
21 21
30
7.2.39
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
135
°
45 29 45
K246a 23 20 27 26 27 20 23 max. length = 6,000 mm
21 21
30
135
°
45 45
K246b 23 20 29 20 23 max. length = 6,000 mm
27 15 27
21 21
30
15
d − 40
d = specify panel insulation thickness
K247
15 max. length = 6,000 mm
30
30
K248b 15 max. length = 6,000 mm
150
90
K249 30 30 max. length = 6,000 mm
150°
40
A
60° 15 d = specify panel insulation thickness
K250 B=d+85 d+35 A = specify dimension
max. length = 6,000 mm
15
60
30
1 1-1
for panel KS1000 RW
d+35
d = specify roof panel insulation
K252 thickness RW
1 50 length = 1,000 mm
(total length = 1,015 mm)
7.2.40
Flashing Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
150°
15
7.2.41
Pre-fabricated
Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres)
150 25 ∅7
12 °
99 D = specify wall panel thickness
45
45
Z03 2 items per meter recommended
18
9
th. 3
Z05 70 D = specify panel thickness
D
th. 3 D−10
Z10 D = specify wall panel thickness
30 30
7.3.42
Pre-fabricated
Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres)
150 25 ∅6
12
°
99 D = specify wall panel thickness
53
53
(100)
(21)
to technical documents.
6 × 7
Z14 (125) (208)
Thickness: 3 mm
Unit length: 1,996 mm
(42)
150
50 25 25 60°
Z15a benchmark JIG for Evolution panels
2
22
6
8.5
6.5
200
20 32 32 32 32 32 (20) 7
Z15b JIG for AWP panels
18
24
6 × 7 2
7.3.43
Pre-fabricated
Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres)
D B D
7.3.44
Pre-fabricated
Components
Accessories Specification
Profile
Ref. Notes
(all dimensions in milimetres)
7.3.45
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1000 AWP
max. length 8,000 mm
Amin, Bmin = 250 mm
R11 A + B = module 1,000 mm
A
α = 80 ˚–175 ˚
α be consulted
α
Panel KS1000 AWP
max. length 8,000 mm
Amin, Cmin = 100 mm
R12
A + B + C = max. module 1,000 mm,
α
R Rmin = D
at the asymmetric corners to determine
the orientation of side lap
profilation to be discussed
B
C
B
Panel KS1000 AWP
max. length 8,000 mm
R
R13 2 × C + B ≤ 900 mm
B > 300 mm, Cmin = 100 mm
60 ˚ < α < 175 ˚
α
Rmin = D
C
7.4.46
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le)
du
o
(m
00
1, 0
Panel KS1000 AWP
R14 max. length 8,000 mm
60 ˚ < α < 175 ˚
Rmin = D
α
Panel KS1000 AWP
A
B
A
Panel KS1000 AWP
R16 Amin, Cmin = 250 mm, Bmin = 500 mm
Amax, Cmax = 1,500 mm, Bmax = 3,000 mm
β
α, β = 90°–180°
B
module 1,000 mm
D
7.4.47
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
A
Panel KS1000 AWP
R17 Dmax = 100 mm
α, β = 135° standard
β α, β – be consulted
B
Panel KS1000 AWP
max. length 8,000 mm
R18 Amin, Bmin = 250 mm
A
Panel KS1000 AWP
max. length L = 7,000 mm
R19
R R = outer radius, Dmax = 120 mm
Rmin = 2,500 mm for D = 40, 60, 80, 100,
120 mm
other sizes consult with the manufacturer
L
D
7.4.48
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1150 TF
max. length 8,000 mm
Amin, Bmin = 250 mm
R21
A
Panel KS1150 TF
max. length 8,000 mm
Amin, Cmin = 100 mm
R22
A + B + C = max. module 1,150 mm
α
R α = 80 ˚–175 ˚
Rmin = D
at the asymmetric corners to determine
the orientation of side lap
B
Panel KS1150 TF
max. length 8,000 mm
R
7.4.49
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le )
du
o
(m
50
1,1
Panel KS1150 TF
R24 max. length 8,000 mm
60˚ < α < 175˚
Rmin ≥ D
α
Panel KS1150 TF
Amin, Bmin = 250 mm
A
α = 90 ˚–180 ˚
module 1,150 mm
D
B
A
Panel KS1150 TF
R26 Amin, Cmin = 250 mm, Bmin = 500 mm
Amax, Bmax = 1,500 mm, Bmax = 3,000 mm
β
α, β = 90 ˚–180 ˚
B
module 1,150 mm
D
7.4.50
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
A (all dimensions in milimetres)
Panel KS1150 TF
R27 Dmax = 100 mm
α, β = 135° standard
β α, β – be consulted
B
Panel KS1150 TF
max. length 8,000 mm
R28 Amin, Bmin = 250 mm
A
Panel KS1150 TF
max. length L = 7,000 mm
R29
R R = outer radius, Dmax = 120 mm
Rmin = 2,500 mm for D = 40, 60, 80, 100,
120 mm
other sizes consult with the manufacturer
L
D
7.4.51
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1150 FR
max. length 6,000 mm
R31 Amin, Bmin = 250 mm
A
α
A + B = max. module 1,150 mm
α = 80 ˚–175 ˚
at the asymmetric corners to determine
the orientation of side lap
Panel KS1150 FR
A
R
Rmin = D
Dmax = 120 mm
at the asymmetric corners to determine
B the orientation of side lap
profilation to be discussed
Panel KS1150 FR
max. length 6,000 mm
R33 R B > 300 mm, Cmin = 100 mm
2 × C + B ≤ 950 mm
60 ˚ < α < 175 ˚
α
Rmin = D
Dmax = 120 mm
C
7.4.52
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le )
du
o
(m
50
Panel KS1150 FR
R
Panel KS1150 FR
Amin, Bmin = 250 mm
A
Panel KS1150 FR
Amin, Cmin = 250 mm
R36 Bmin = 500 mm
β Amax, Cmax = 1,500 mm
Bmax = 3,000 mm
B
α, β = 90 ˚–180 ˚
D
module 1,150 mm
7.4.53
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
A (all dimensions in milimetres)
Panel KS1150 FR
R37 Dmax = 100 mm
β α, β = 135° standard
A + B + C = max. module 1,150 mm
B
Panel KS1150 FR
max. length 4,000 mm
R38 Amin, Bmin = 250 mm
A
α = 90°, Rmin = D
at the asymmetric corners to determine
the orientation of side lap
L
D
7.4.54
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1000 FH
max. length 6,000 mm
R41 Amin, Bmin = 250 mm
A
Panel KS1000 FH
max. length 6,000 mm
Amin, Cmin = 60 mm
A + B + C = max. module 1,000 mm
R42
α = 80 ˚–175 ˚
α
R
Rmin = D
Dmax = 120 mm
at the asymmetric corners to determine
B the orientation of side lap
profilation to be discussed
Panel KS1000 FH
max. length 6,000 mm
2 × C + B ≤ 900 mm
R43
R
B > 300 mm
Cmin = 100 mm
60 ˚ < α < 175 ˚
α
Rmin = D
Dmax = 120 mm
C
7.4.55
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le )
du
o
(m
00
Panel KS1000 FH
R
Panel KS1000 FH
Amin, Bmin = 250 mm
A
Panel KS1000 FH
Amin, Cmin = 250 mm
R46 Bmin = 500 mm
β Amax, Cmax = 1,500 mm
Bmax = 3,000 mm
B
α, β = 90 ˚–180 ˚
D
module 1,000 mm
7.4.56
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
A
Panel KS1000 FH
R47 Dmax = 100 mm
β α, β = 135° standard
A + B +C = max. module 1,000 mm
B
Panel KS1000 FH
max. length 4,000 mm
R48 Amin, Bmin = 250 mm
A
α = 90°, Rmin = D
at the asymmetric corners to determine
the orientation of side lap
Panel KS1000 FH
R49 R
max. length L = 6,000 mm
Rmin = 2,500 mm for D = 80, 100, 120 mm
other sizes consult with the manufacturer
L
D
7.4.57
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1150 TL
max. length 8,000 mm
Amin, Bmin = 250 mm
R51
A
α be consulted
at the asymmetric corners to determine
the orientation of side lap
Panel KS1150 TL
max. length 8,000 mm
Amin, Cmin = 100 mm
R52
A + B + C = max. module 1,150 mm
α
R α = 80 ˚–175 ˚
Rmin = D
at the asymmetric corners to determine
the orientation of side lap
B
Panel KS1150 TL
max. length 8,000 mm
R
7.4.58
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le )
du
o
(m
50
1,1
Panel KS1150 TL
R54 max. length 8,000 mm
60˚ < α < 175˚
Rmin ≥ D
α
Panel KS1150 TL
Amin, Bmin = 250 mm
A
α = 90 ˚–180 ˚
module 1,150 mm
D
B
A
Panel KS1150 TL
R56 Amin, Cmin = 250 mm, Bmin = 500 mm
Amax, Bmax = 1,500 mm, Bmax = 3,000 mm
β
α, β = 90 ˚–180 ˚
B
module 1,150 mm
D
7.4.59
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
A (all dimensions in milimetres)
Panel KS1150 TL
R57 Dmax = 100 mm
α, β = 135° standard
β
A + B + C = max. module 1,150 mm
B
Panel KS1150 TL
max. length 8,000 mm
R58 Amin, Bmin = 250 mm
A
Panel KS1150 TL
max. length L = 7,000 mm
R59
R R = outer radius, Dmax = 120 mm
Rmin = 2,500 mm for D = 40, 60, 80, 100,
120 mm
other sizes consult with the manufacturer
L
D
7.4.60
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
Panel KS1150 TC
max. length 8,000 mm
Amin, Bmin = 250 mm
R61
A + B = max. module 1,150 mm
A
α = 80 ˚–175 ˚
α
Panel KS1150 TC
max. length 8,000 mm
Amin, Cmin = 100 mm
R62 A + B + C = max. module 1,150 mm
α
α = 80 ˚–175 ˚
R
Rmin = D
at the asymmetric corners to determine
the orientation of side lap
profilation to be discussed
B
Panel KS1150 TC
max. length 8,000 mm
2 × C + B ≤ 950 mm
R
Rmin = D
Dmax = 120 mm
C
7.4.61
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
(all dimensions in milimetres)
le)
du
o
(m
50
1, 1
Panel KS1150 TC
R64 max. length 8,000 mm
60˚ < α < 175˚
Rmin ≥ D
max. module 1,150 mm
α
Panel KS1150 TC
Amin, Bmin = 250 mm
A
α = 90 ˚–180 ˚
module 1,150 mm
Dmax = 120 mm
D
Panel KS1150 TC
Amin, Cmin = 250 mm
R66 Bmin = 500 mm
Amax, Cmax = 1,500 mm
β
Bmax = 3,000 mm
B
α, β = 90 ˚–180 ˚
module 1,150 mm
D
7.4.62
Pre-fabricated Insulated
Accessories Corners Specification
Profile
Ref. Notes
A (all dimensions in milimetres)
Panel KS1150 TC
R67 Dmax = 100 mm
α, β = 135° standard
β
A + B + C = max. module 1,150 mm
B
Panel KS1150 TC
max. length 8,000 mm
R68 Amin, Bmin = 250 mm
A
Panel KS1150 TC
max. length L = 7,000 mm
R69
R R = outer radius, Dmax = 120 mm
Rmin = 2,500 mm for D = 40, 60, 80, 100,
120 mm
other sizes consult with the manufacturer
L
D
7.4.63
Eave Rainwater
System Specification –
Accessories Angular
08 03
80 (cut back) P P
08 600 mm
P α
127
K
d
20 35 25
Back putty
126
K
13
P
126b
K
126c
K
126d
K
126g
K
max. 2,000 mm
03
P
126e
K
31
P
126g
K
126f
K
X
150
7.5.64
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
panel
RW FF
profile
material material
roofslope α X X
width width
[°] [mm]
3 143 596 144 597
4 146 599 147 600
5 149 602 150 603
6 152 605 153 606
7 155 608 156 609
8 158 611 159 612
9 161 614 162 615
10 165 618 166 619
11 168 621 169 622
Closed Gutter 12 171 624 172 625
13 174 627 175 628
35
14 177 630 178 631
α
15
°+
α
90
(84)
21 199 652 200 653
175 (173) 22 202 655 203 656
23 205 658 206 659
24 209 662 210 663
25 212 665 213 666
26 215 668 216 669
27 219 672 220 673
28 222 675 223 676
29 226 679 227 680
30 229 682 231 684
Notes:
Max. length up to 8,000 mm, recommended length to
6,000 mm.
7.5.65
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Gutters Punction
89
84
10
0°
173
Cage
∅d
L = specify dimension
L
∅d = B − 2
∅d available B × B dimensions:
K126c
100 × 100, 120 × 120, 150 × 150
available for diameters:
∅100, ∅120, ∅150
Downpipe – four-square
available B × B dimensions:
100 × 100, 120 × 120, 150 × 150
7.5.66
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Bounce – four-square
C = specify dimension
B = specify dimension
β
B = specify dimension
°
K126f
135
available B × B dimensions:
100 × 100, 120 × 120, 150 × 150
Sleeve – four-square
A
B, C = specify dimensions
available B dimensions:
K126g 100, 120, 150
C = 50–100 mm
B
A = 50 mm
B C
7.5.67
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Gutter stop
C = specify dimension
B = specify dimension
β
panel material
A B β [°]
profile width [mm]
Gutter Hook
RW 35 35 70 132
K127 A FF 24 38 58 130
B B β
β
7.5.68
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
variable material
roofslope tileslope variable angle
value width
α [°] α1 [°] β [°] ε [°] X [mm] [mm]
12 8 98 108 156 606
13 9 99 109 159 609
14 10 100 110 162 612
15 11 101 111 165 615
16 12 102 112 168 618
17 13 103 113 171 621
18 14 104 114 175 625
19 15 105 115 178 628
20 16 106 116 181 631
35 15 21 17 107 117 184 634
22 18 108 118 187 637
β
35
23 19 109 119 190 640
15 24 20 110 120 193 643
25 21 111 121 196 646
ε
α = specify roofslope (° or %)
specify for roof panel RT
*X = according to the table
max. length up to 8,000 mm,
recommended length to 6,000 mm
More information on the order form.
7.5.69
Eave Rainwater
System Specification –
Accessories Angular
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Gutters Punction
α = specify roofslope (° or %)
89
specify for roof panel RT
K232a X−2*
*X = according to the table item K232
160°
84 10
0°
173
450 21
15 ° 15
138
88
7.5.70
Eave Rainwater
System Specification –
Accessories Round
07
P
mm α
08 min. 190
P
30
110
d
K
16
P
107
K
136
K 10
P
01b
Z
136c
K
136d
K
03
P
136g
K
max. 2,000 mm
136f
K
D
03
P
136h
K
136i
K
150
7.6.71
Eave Rainwater
System Specification –
Accessories Round
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Half-round Gutter
∅D = specify diameter
∅D
L = specify length (standard max. 4,000 mm)
available ∅D/girth:
K136 120/280,
160/330,
200/400,
240/500
Gutter Stop End Gutter stop end it is possible ordered separately or factory
applied.
∅D The gutter stop end can be produced in RIGHT or LEFT option.
(The picture shows RIGHT gutter stop end.)
K136a For order please specify:
∅D = diameter
– RIGHT or LEFT option
∅d = specify diameter
K136b L = specify length
L
∅d
∅D
7.6.72
Eave Rainwater
System Specification –
Accessories Round
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
∅d = specify diameter
30°
K136d C = specify dimension
available ∅d: 80, 100, 120, 150
∅d
Expansion Basket
∅D
∅d = specify diameter
∅D = specify diameter
K136e
available ∅d & ∅D combinations:
80 & 120, 100 & 160, 120 & 200, 150 & 240
∅d
∅d = specify diameter
L = specify dimension
K136f available ∅d:
L
∅d
7.6.73
Eave Rainwater
System Specification –
Accessories Round
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
Round Sleeve
40 ∅d = specify diameter
∅d
available ∅d:
K136g 80, 100, 120, 150
25
external coating:
bar ∅8 mm galvanized + comax
fastener
Round Bounce
150
C
∅d = specify diameter
C = specify dimension
K136h β = specify angle (°)
available ∅d:
β
∅d
∅d
∅d = specify diameter
135
7.6.74
Eave Rainwater
System Specification –
Accessories Round
Profile
Ref. Notes
(all dimensions in milimetres, – colorcoated side)
2× hole ∅7
∅D = specify diameter
220
available ∅D:
Z01a ∅D 120, 160, 200, 240
external coating:
galvanized + comax
2× hole ∅7
∅D = specify diameter
∅D
α B = specify dimension
α = specify angle (° or %)
Z01b available ∅D:
B
∅D = specify diameter
4× hole ∅7 A = specify hook offset (standard 41 mm)
B = specify hook height
B
7.6.75
Pre-fabricated
Insulated Rainwater
Accessories Systems Specification
Profile
Ref. Notes
(all dimensions in milimetres)
A = 530 F
α
B = 164
°
L01 125
E=
β=
20
0
D
Maximum length of insulated gutters is 6,000 mm
C = 300 including end overlaps.
The production limit for insulated gutters is the
maximum girth of bottom sheet, which is 1,250 mm.
For order please specify:
D A = 415 F insulation depth D
α roof slope α
25
°
L03 125
0
β=
20
E=
D
C = 300
L04 90 25 ° sections)
0
°+ =1
20
7.7.76
Pre-fabricated
Insulated Rainwater
Accessories Systems Specification
Profile
Ref. Notes
(all dimensions in milimetres)
A = 530 F
α
B = 164
°
125
L05 β=
E=
20
0
D
Maximum length of insulated gutters is 6,000 mm
C = 300
including end overlaps.
The production limit for insulated gutters is the
maximum girth of bottom sheet, which is 1,250 mm.
D A = 415 F For order please specify:
α insulation depth D
25
roof slope α
B = 164
°
125
L07 β=
0
20
E=
D
C = 300
β=
90
L08 sections)
°+
0
20
α