0% found this document useful (0 votes)
482 views1 page

Escalator Design Specifications

This document provides specifications for elevator installation and safety requirements. It outlines requirements for elevator structure, machinery, equipment, hoistway enclosures, pits, and clearances. Elevator plans must be submitted and signed by registered engineers. Hoistways must be enclosed and fire resistant. Pits must prevent water entry and maintain fall clearances.

Uploaded by

GeLow EdOra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
482 views1 page

Escalator Design Specifications

This document provides specifications for elevator installation and safety requirements. It outlines requirements for elevator structure, machinery, equipment, hoistway enclosures, pits, and clearances. Elevator plans must be submitted and signed by registered engineers. Hoistways must be enclosed and fire resistant. Pits must prevent water entry and maintain fall clearances.

Uploaded by

GeLow EdOra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

107.

2102
14.3735 70.3033 15.7739

GENERAL NOTES
POWER SUPPLY
MOTOR PANEL
CEILING 9.7297
The owner/manager or his authorized representative shall file with the
Secretary or his authorized representative having jurisdiction an application to
install or construct an elevator together with the necessary plans in triplicate 10.4177
signed and sealed by a registered professional mechanical engineer for the
mechanical plans and by a professional electrical engineer for the electrical plans,
both duly licensed to practice in the Philippines.
34.7912
1. Every part of the structure, machinery, and equipment shall be:
a. of good design, good mechanical construction, sound material,
adequate strength, free from defects, anD
b. kept in good working condition. 30°
2. Hoistways from all elevators shall be substantially enclosed throughout
their height and there shall be no openings except for necessary doors,
windows or skylights.

3. Hoistways for elevators outside the buildings shall be substantially enclosed


to a height of at least 3 m (10 ft.) provided that the enclosure shall be
continuous to the top of any side where there is access to the cage.

4. The enclosures shall be either a continuous wall or substantial grill work, 2ND FLOOR
metal bars, or wood slats. In general enclosures shall be fire resistant.

5. 1

a. Where a hoistway extends into the top of a building, fire-resistant


hoistway or machinery spaced enclosures shall be carried to the underside 2

of the roof, if the roof is of fire-resistive construction, and at least 90 cm (3 3


1ST FLOOR
ft.) above the surface of the roof, if the roof is of non-fire-resistive
construction; 4

b. Where a hoistway does not extend into the top floor of a building, the
top of the hoistway shall be enclosed with a fire resistant construction.

6.
a. A pit shall be provided for every elevator. 5
BASEMENT
b. The floor of the pit shall be approximately level.
6

c. Pits extending below the ground level shall have non-combustible 7

8
floors and shall be designed to prevent entry of ground water into the pit.
The pit floor of any hoistway not extending to the ground shall be of fire
resistant construction.
d. Hoistway pits shall be of such depth that when the car rests on the fully
compressed buffers, there shall be a vertical clearance of not less than 610 INDEX

REFERENCIA\vpa-BEI-AXES-FAC-E-200.dwg
..\01
Xref
mm. between the pit floor and the lowest structural or mechanical part,
equipment or device installed beneath the car platform except guide shoes 1 SKIRT BRUSHES 5 DRIVE CHAIN MOTOR
STEP WIDTH
or rollers, safety jaw assemblies, and platform aprons, guards, or other SPECIFICATIONS
2 STEP GAP LIGHTING 6 SERVICE BRAKE Nominal step width 1000mm
equipment located within 305 mm. horizontally from the sides of the car Nominal step width 1000mm
platform. Width between handrails 1,158mm
3 COMBPLATE LIGHTING 7 EMERGENCY BUTTON / KEY
Angle of inclination 30 degrees
Handrail center distance 1,238mm
4 HANDRAILS 8 DIRECTION INDICATOR Max Rise 20 meters
Width of escalator 1,540mm
Speed 0.65 m/s
Width of pit 1,600mm

Drawn by: Members: D a t e:

EBORA, JOHN PAULO DIZON, JAN ERICK JANUARY 25, 2019


EDORA, ANGELO MANUEL S. ENVERGA UNIVERSITY
ESCALATOR DESIGN DULGUIME, JERRIC ESPINOSA, ALVER JOHN
S c a l e @ A3:
FOUNDATION
D r a w i n g T i t l e: 1:1
SCALE 1 : 1 LUCENA CITY
ENGR. FRANCISCO A. MAAÑO JR. Drawing no.
Professional Mechanical Engineer
ESCALATOR DESIGN COLLEGE OF ENGINEERING
1

You might also like