101
ACCURACY - %
100
99
Model 16M175 Above data has been determined from tests performed
98 Body Type Series B with air at atmospheric pressure and ambient tempera-
ture, using positive displacement bell or piston provers
Start Rate 3.2 cfh
97 dimensionally traceable to the United States National
Stop Rate 1.9 cfh Institute of Standards and Technology (NIST) and
Rangeability ±1% 116:1 traceable to NMi - Netherlands Measurements
Rangeability ±2% 223:1 Institute for volumetric flow rate.
Differential Curve
2.0
DIFFERENTIAL - IN. W.C.
1.5
1.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100
To order
Specify: Meter Series, Size and Type
(i.e., ROOTS Meter Series B3 16M175 CD).
For CD or TD, specify Inlet (Top or Side) and
Height
ID Rotation (CW-B or CCW-A).
Accessory Unit
For Pulser, specify Single or Dual Connectors and
Connector Type (MS Circular, Conduit or Cable Gland).
For more specific ordering information on the electronic
products, request:TS:SSP, TS:IMC/C or S: IMC/W.
CL-AU
Contact the factory for other available information,
Length
options, or special requests.