You are on page 1of 8
west El Burullus Pet.co, dase oll Gud ye, [Petroweb ] (sesh) Operatioy Paesteesty, | |e To : Projects General Manager ay riacoeniz| | From : Operations General Manager erent Ona iy. | Date : 21/07/2019 acre | Necheal Satay Mo Subject Issuing a tender for Wellhead and X-mass trgesiforiRd Reference to the above mentioned subject, and upeoming Drilling ofp Burullus Petrolewn Company, we are going to issue a tender for well please note the following to be considered in the Engineering & procureiT * The weld neck that should be connected to the adjustable choke flange (4 1/16" SK) should be purchased by Projects department ater determining the flow line Schedule The adjustable choke for each X-Tree will be ordered in the X-Tree tender as hydraulically operated and the different throttle sizes will be corresponding to different hydraulic pressures submitted from the panel. = + The configuration of the well head will be as following © Casing Head 20” Slip Lock X 2024" 3Ksi with two side valves 2 1/16", 5K. © Casing Spool 20 % 3Ksi X 13 $/8” SKsi with two side valves 2 1/16", 5K Tubing Spool 13 5/8” SKsi X 13 5/8” SKsi with two side valves 2 1/16”, 5K Two Stage X-Tree solid block 13 5/8” SKsi X4 U/16" SKsi_ * ° ° ° The X-tree has two wing valves (Production & Kill). ° The X-tree will have two actuator valves, one in the upper master valve and the other is connected downstream the manual production wing valve and upstream the instrument flange. Best Regards. ELT ee ASN. 2 zeti er Eng. Nasr Ramadan Hassan Eng. Tarek Khalifa Deputy Operations General Operations General Manager Manager &BoardMember 9 tdi ? west El Burullus Pet.co, date lal Gud Asya [Petroweb } (sat) Operations Department Salad Lala 51871 Internal Memo To : Projects General Manager From: Operations General Manager Date : 21/07/2019 Subject : Issuing a tender for Wellhead and X-mass trees for Petroweb: Burullus Petroleum Company, we are going to issue a tender for well heads & X-Trees and please note the following to be considered in the Engineering & procurement phases: + ‘The weld neck that should be connected to the adjustable choke flange (4 1/16" 5K) should be purchased by Projects department after determining the flow line Schedule. + The adjustable choke for each X-Tree will be ordered in the X-Tree tender as hydraulically operated and the different throttle sizes will be corresponding to different hydraulic pressures submitted from the panel * The configuration of the well head will be as following: © Casing Head 20” Slip Lock X 20 4” 3Ksi with nwo side valves 2 1/16". SK. © Casing Spool 20 % 3Ksi X 13 5/8” SKsi with two side valves 2 1/16", 5K Tubing Spool 13 5/8” SKsi X 13 5/8" SKsi with two side valves 2 1/16", 5K ° © Two Stage X-Tree solid block 13 5/8” SKsi X 4 1/16" SKsi 9 ° The X-tree has two wing valves (Production & Kill). The X-tree will have two actuator valves, one in the upper master valve and the other is connected downstream the manual production wing valve and upstream the instrument flange Best Regards. Fly Eng. Nasr Ramadan Hassan Deputy Operations General Operations General Manager Manager & Board Member asl dal is ‘Amal Petroleum Co, (sibel ) [AMAPETCO] Tatas Bley Operations Dept Cilplaadt To : Projects General Manager From; Operation General Manager Date: 17/07/2019 Subject: _E-line equipment layout Ref. to above mentioned subject, and regarding minutes of meeting dated 10/07/2019 Please find here attached the proposed layout of E-line equipment on weather deck with following comments:- 1- The crane should access all weather deck area including wells area, 2- Total span from edge of weather deck to edge of first adjacent well (excluding wells hatches area) should be minimum of 15 MX 11M. 3- The equipment should be on the weather deck during the operations. Thanks, \ cafall F- Kh, yous WAYLIBA Eng, Nasr Ramadan Eng. Tarek Khalifé “ a Deputy Operation General Operation General Manger Manager & Board Member Sdid seyung sossasdwoo al ue} jasaiq IT Minutes of meeting Date: 30072019 Subjeet : Clori tions related to WEB Platform Attenclees [ing are Kala heed | Bog/Nosr Ramadan \'pon some bidders clerification that has bem cased eoneerning the WEB oishore platform Droject the following items were agreed 2s follows: Item Clarification agreed ‘measurement ~~~ Bach Howling Ws provided with a wal vas voulue meter “and in case of malfunction fist atty one of 1 1 them a Multiphase Flow Meter will be used as a i backup. 7 3 Felideek | Helideck Will be available for use when ‘equipmei | 8 stored (as lay out) on weather deck .but not whe igged up wice line equipments is in place and weather “deck shill “accommodate all Feline equipment’ und helideck must be clear to handle helicopter operationand add chopper landing on ____| helideck during rig op as option 2 A and met men cent ae BUTI Minutes of Meeting Based on the clarifications requested for the WEB offshore platform project (E-mail attached) a ‘meeting was held as following Operations Meeting Room (10/07/2019 - 11:00 am = 12:00 pm) Attendees peer eeceenat Tag! Tamer Hassan ~ Engi ibrahim tantawy? teh Fefad! eit Eng/ Magdy Awad HEALY Eng/ Mohamed Eltohamy Tng/ Abd Bifatah Fayed Eng/ Khalid Ashour [bal Eng/ Mohamed Abd Elfatah tT Eng/Vehia Sayed Yoh os AAD Discussion [Eng Mohamed Seb | Clarifications requested by projects Reply by Operations 1, Please provide the current and the future conductor diameter for WEB platform * 30 inch for future and eurrent conductors the wire line and workover operations 2. Is the helideck shal) be in services during + Yes, In case of rig less operation * No, In case of rig operation equipment packages / layout during this operation 3. Please provide the wireline and work over ‘+ operations stated reply will be provided tomorrow to be in same weather deck level 4. Is it mandatory requirement for the helideck + I's not mandatory but point number( 2) shall be achieved ( the helideck shall be in services during rig less operations) Lof2 BMS: outlook. office.com/owa/projection.asp: Reply all| Delete Junk] Fwd: clarifications on WEB offshore platform project Ag. Abdel Fatah Fayad ‘a Reply all | Wed 10/07/2019 10°55 AM To: Khalid Ashour, Yehia Sayed Abdel Gali inbox For reply Get Outlook for Android From: Nast Hamed Sent: Wednesday, July 10, 2019 10:34:34 AM To: Abdel Fattah Fayad Tarek Khalifa; Reda Lasheen Subject: FW: clarifications on WEB offshore platform project Dear Abdel Fatah Please arrange review the below requirements and arrange for a meeting with WEB project coordinators to discuss and take the necessary action Regards rast From: Tamer Hasan Medhat [mailto:tamer.hassan@amapetco.com.ea] Sent: Tuesday, July 09, 2019 9:16 PM To: Tarek Khalifa; Nasr Hamed Subject: Fw: clarifications on WEB offshore platform project Dear Eng Tarek / Eng Nasr please your kind support and guidance to drilling and engineering departments to clarify the points in process engineer mail by tomorrow will be highly appreciated in order to be able to answer for these inquiries for all biders on time. Thanks and best regards Tamer Hassan 7110/2019, 12:52 PN 2of2 Tee /hutps://outlook.office.com/owa/projection.asp, Reply all Delete Junk} ramer Hasan Medhat fohamed El-Tohamy Subject: clarifications on WEB offshore platform project Dear sir Your kind support is required to clarify the following points regarding the WEB offshore platform Drilling: ~Please provide the current and futuse conductors diameters for WEB platform Engineering: «Is the helideck shall be in service during the wire line & work over operations? ~ Please provide the wite line & work over equipment / packages layout during this operation ~ is it mandatory requirement for the helideck to be in the same weather deck level? Kind regards Mohamed A.fateh ‘70/2019, 12:52 P,

You might also like