You are on page 1of 6

Company's Nam

Element

1 Accountable Person
1.1 Overall Accountability
1.2 Well Integrity Policy Updates
1.3 Organizational Capability & Training

2 Operating Procedures
2.1 Startup-Shutdown Procedures
2.2 Sand,Paraffin & Scale Detection/Management

3 Intervention Procedures
3.1 Develope Individual Intervention Procedures - Petroleum Managed
3.2 Risk Assessment
3.3 Wireline (Slickline) Procedures
3.4 E-line Procedures
3.5 Coiled Tubing Procedures
3.6 General Pumping Procedures (Scale Inh, Tbg Clean)
3.7 Well Killing & Securing

4 Tubing / Casing Annulus Integrity


4.1 Define Minimum Safe Pressure Limits-Well Ops
4.2 Define Minimum Safe Pressure Limits-Production & Injection
4.3 Develope Operating Procedues
4.4 Develope Diagnostic Procedues
4.5 Annuli Pressures Monitoring
4.6 Maintain Pressure Records
4.7 Initiate Risk Review on Problem Wells

5 Xmas Tree Integrity


5.1 X-Tree Valve Maintanance & Testing
5.2 X-Tree Test Result Documentation
5.3 Maintain Testing Records
5.4 X-Tree Valve Repair

6 SSSV Integrity
6.1 Mointor Control Line Pressure
6.2 SSSV Testing Schedule Compliance
6.3 Test Result Documentation
6.4 Diagnostic Procedues
6.5 SSSV Repair Procedures

7 Drilling & Work-over Ops Programs (DWOP)


7.1 Dispensation from DWOP-Drilling Controlled
7.2 Dispensation from Well Ops-Petroleum Eng. Controlled

8 Documentation
8.1 Notification of Removal from Service (Wells)
8.2 Well Handover Documentation
8.3 Well work Request Data Package
8.4 Rig Schedule for Drlg. & WO Plan
8.5 Well Intervention Plan
Company's Name Well Integrity RASCI Chart

.
grs

r
am

.
M

de

grs
gr .

er
Te

Lea
n.

d.
ine
GM
Ge

P ro
WO
n.

n.
ng
m
A
Ge

Ge
ns

ea

IE

re
PE

&
tio

g.

IT

ld

sho
W.
lg.
En
era

Fie
W.
Dr

Off
Op

Cairo ABB Field


A I I I I I I
A I C C R R I
A R C C C C R

A I I C C C R
A I I C C C R

troleum Managed A R R C C C I
AR R C C C I
AR R C C C I
AR R C C C I
AR R C C C I
n) AR R C C C I
A R C R C C R

A I C R R R I
& Injection A I C R R R R
R C C AR R I
R C R AR R I
I R C AR R I
I R C AR R I
A R R R R R I

A I C C C C R
I R C R R AR
I R C R R AR
A I C C R R R

I I I I I AR
I R C R R AR
I R C R R AR
R C R R R AR
A R R R R R I

A R R R C C I
A R C R R R C
trolled A R R C R R C

I R R R R I
A R R R I I R
A I I R C C R
A R R R I I I
A R R R C C C
A R R C C C C

A Accontable for Op's Mgrs


R Responsible
C Consult
I Inform
AR Authorized & Responsible
W.
IE
ng
ine
er
Fie
ld
Ge
n.
M

I
grs

C
C
C

R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
.
Off

ABB Field
sho
re
Pro
d.
AG

I
M

C
C
C

R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Off
s ho
re
Pr o
d.
En
g.
R R
R R

R R
R R
R R
R R
C C

I I
C I
C I

R R
R I
R R
R I
C I
C I

You might also like