This document is a data sheet for a meter turbine to be procured in 2021. It provides specifications for a G-40 DN50 ANSI 150 meter turbine, including details on size, flow rates, materials, pressure rating, accuracy, pulse transmitters, and manufacturer. The meter turbine is to be used for measuring natural gas flow, with specifications like an IP65 ingress protection rating and intrinsic safety level of II 1/2G Eex ia IIC T6.
This document is a data sheet for a meter turbine to be procured in 2021. It provides specifications for a G-40 DN50 ANSI 150 meter turbine, including details on size, flow rates, materials, pressure rating, accuracy, pulse transmitters, and manufacturer. The meter turbine is to be used for measuring natural gas flow, with specifications like an IP65 ingress protection rating and intrinsic safety level of II 1/2G Eex ia IIC T6.
This document is a data sheet for a meter turbine to be procured in 2021. It provides specifications for a G-40 DN50 ANSI 150 meter turbine, including details on size, flow rates, materials, pressure rating, accuracy, pulse transmitters, and manufacturer. The meter turbine is to be used for measuring natural gas flow, with specifications like an IP65 ingress protection rating and intrinsic safety level of II 1/2G Eex ia IIC T6.
AMS BY CHCK'D APP'D CHCK'D APP'D REV DATE PAGE DESCRIPTION NP BG AB SHEET 2 OF 2 JOB NO. DATA SHEET PO NO : - PT. ALGAS MITRA SEJATI DOCUMENT NO. DESCRIPTION DATE REV. - ISSUED FOR BID 24/06/2021 A AMS PREPARED BY CHECKED BY APPROVED BY CHCK'D APP'D
PROJECT : PENGADAAN METER TURBIN TAHUN 2021
DATA SHEET METER TURBIN G-40 DN50 ANSI 150 1 Client : 2 Service : Natural Gas GENERAL 3 Quantity : TBA 4 Tag No. : TBA Value Units 5 Size : 40 G FLUID CONDITION 6 Minimum Flow Rate : 6.5 m3/h 7 Maximum Flow Rate : 65 m3/h 8 Temperature Range : -10 to 60 deg C 9 Rangeability : 1:10 10 Color : Yellow ( RAL 1003) 11 Body Material : Ductile Iron 12 Turbine Wheel Material : Alumunium 13 Mechanical Counter : Yes - UV Resistance 14 Totalizer Unit : m3 15 Totalizer Index : 8 digit (6 + 2 Decimals) 16 Pipe Size Connection : 2" 17 Length : 150 mm 18 Pressure Rating : ANSI #150 19 Flange Type : RF - RF 20 Accuracy : ±1% for Qmin to 0.2 Qmax : ±0.5% for 0.2 Qmax to Qmax 21 Reproduceability / Repeatability : < + 0.1% 22 Pulse Transmitters : Low Frequency (Reed Switch) Double LF 1-2 / 5-6, single socket connector max. frequency 1 Hz METER 23 Measuring Scale : 10 : 1 pulse/m3 24 Lubrication System : Yes Preferable with dirt protection and full flushing oil pump systems 25 Ingress Protection : IP 65 as minimum 26 Mounting Pipe Length : Inlet : 2 DN Outlet : 3 DN 27 Thermowell : Yes 28 Pressure Tapping : Yes 29 Intrinsic Safety Level : II 1/2G Eex ia IIC T6 (higher level than II 1/2G Eex ia IIC T5) 30 Connector to Volume Corrector : Yes 31 Flow Straightener : Yes, Integrated in body 32 Mounting Position : Horizontal 33 Flow Direction : Left to Right (marked on the meter body) 34 Corrosion Protection : Zinc Electroplating, Coated Linear, Painting 35 Number of Bolt Holes : 4 36 Anti Tempered : Yes 37 Manufacturer : VEMMTEC 38 Model : IGTM - CT REMARK 39 Calibration Certificate : Issued by Manufacture, traceable to International Standard and : Issued by Direktorat Meterologi - Indonesia