REE_085_20200323

1) In terms of GMD and GMR the capacitance values of transmission line can be
obtained as
a. C=2∗10−7ln(𝐺𝑀𝐷/[(𝑒(−1/4))∗𝐺𝑀𝑅 )]
b. 𝐶=[(2∗𝞹∗ε0)/𝑙𝑛(𝐺𝑀𝐷/𝐺𝑀𝑅)]
c. 𝐶=[(2∗𝞹∗ε0)/𝑙𝑛(𝐺𝑀𝐷*𝐺𝑀𝑅)]
d. C=2∗10−7ln(𝐺𝑀𝐷*[(𝑒(−1/4))/𝐺𝑀𝑅 )]
2) In Corona loss the critical value voltage is
a. 𝑉𝑐 = 𝑔𝑣 ∗ 𝑚 ∗ 𝛿 ∗ 𝑟 ∗ ln( 𝐺𝑀𝐷/𝑟)
b. 𝑉𝑐 = 𝑔𝑣 ∗ 𝑚 ∗ 𝛿 ∗ 𝑟 / ln( 𝐺𝑀𝐷*𝑟)
c. 𝑉𝑐 = 𝑔o ∗ 𝑚 ∗ 𝛿 ∗ 𝑟 / ln( 𝐺𝑀𝐷*𝑟)
d. 𝑉𝑐 = 𝑔o ∗ 𝑚 ∗ 𝛿 ∗ 𝑟 ∗ ln( 𝐺𝑀𝐷/𝑟)
3) The corona loss Pc is,
a) 𝑃𝑐 = (241/δ) (𝑓 + 25) (𝑟/D)1.5 (𝑉−𝑉𝑂)2 ∗ 10−5
b) 𝑃𝑐 = (241/δ) (𝑓 + 25)2 (𝑟/D)0.5 (𝑉−𝑉𝑂)2 ∗ 10−5
c) 𝑃𝑐 = (241/δ) /(𝑓 + 25) (𝑟/D)0.5 (𝑉−𝑉𝑂)2 ∗ 10−5
d) 𝑃𝑐 = (241/δ) (𝑓 + 25) (𝑟/D)0.5 (𝑉−𝑉𝑂)2 ∗ 10−5
4) Peek’s formula gives better results when frequencies are between,
a) 25-120 Hz
b) 25 -120 KHz
c) 0-25 Hz
d) More than 120 KHz
5) Voltage regulation percentage is
a) %𝑉𝑅 = [𝑉𝑟/(Vs- 𝑉𝑟)] ∗ 100
b) %𝑉𝑅 = [𝑉𝑟/Vr- 𝑉s)] ∗ 100
c) %𝑉𝑅 = [(𝑉𝑠−𝑉𝑟)/ 𝑉𝑟] ∗ 100
d) %𝑉𝑅 = [(𝑉r−𝑉s)/ 𝑉𝑟] ∗ 100
6) Electrodes used in Hydrogen-Oxygen Fuel Cells is
a) Iron
b) Gold
c) Platinum
d) Nickel
7) Solid Oxide Fuel Cells has electrolyte membrane made of
a) Metal Ceramic
b) Yttruim Stabilized Zirconia
c) Carbon
d) Lithium
8) Proton Exchange Membrane Fuel Cells is commonly used for
a) Transportation
b) Industrial use
c) Mechanical
d) None of the above
9) Regenerative Fuel Cells split water with the help of
a) Solar Energy
b) Thermal Energy
c) Electrical Energy
d) Mechanical Energy
10) Alkaline fuel cell has _____________ efficiency.
a) 40%
b) 50%
c) 60%
d) 20%
11) Simplest method of hydrogen production is
a) Electrolysis of water
b) Thermolysis of water
c) Steam reforming of methane
d) Bio Photosynthesis
12) We need the interconnected power system because, apart from delivery, the
purpose of the transmission network is to pool power plants and load centres in
order to:
a. Minimize the total power generation capacity and fuel cost.
b. Maximize the total power generation capacity and fuel cost.
c. Minimize the total power generation capacity and maximize fuel cost.
d. Maximize the total power generation capacity and minimize fuel cost.
13) If a power delivery system was made up of radial lines from individual local
generators without being part of a grid system, __________ generation resources
would be needed to serve the load with the same reliability, and the cost of
electricity would be ________.
a. Many more, much higher.
b. less, much higher.
c. Many more, much higher.
d. Less, much lower.
14) As power transfers grow, the power system becomes increasingly more complex
to operate and the system can become less secure for riding through the major
outages. It may lead to:
a. Large power flows with inadequate control
b. Excessive reactive power in various parts of the system.
c. Large dynamic swings between different parts of the system
d. All of the above.
15) By providing added flexibility, FACTS Controllers can enable a line to carry power:
a. Closer to its thermal rating.
b. Quit less than its thermal rating.
c. More than its thermal rating.
d. None of the above.
16) The FACTS technology is not a single high-power Controller, but rather a collection
of Controllers, which can be applied:
a. Only individually.
b. Only in coordination with others.
c. Individually OR in coordination with others.
d. None of the above.
17) Just as the transistor is the basic element for a whole variety of microelectronic
chips and circuits, the _____________is the basic element for a variety of high-
power electronic Controllers:
a. Thyristor.
b. High-power transistor.
c. Thyristor or high-power transistor.
d. None of the above.