You are on page 1of 13

AS BUILT

DATE OF ISSUE
DRAWING PACKAGE VERSION

GENERAL

Connectel
Sundeep Chand 28/02/2019, 8:00:28 pm

ANTENNAS & TRANSMISSION S.Chand


................................................

STRUCTURAL
OPTUS SITE - S0607
ELECTRICAL
MONASH
AXICOM SITE ID: 3000669
SHELTER / FITOUT
McBRYDE CRESCENT
WANNIASSA, ACT 2903
EME EXCLUSION ZONES
JV SITE ID: JC9008
LEASE / LICENCE
RANCAP UPGRADE - EJV SITE SHARING
OPTUS WORK AUTHORITY Nº 418058

REFERENCE DOCUMENTS

HUAWEI TECHNOLOGIES (AU) PTY LTD


ABN 49 103 793 380

SYDNEY MELBOURNE
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY LEVEL 24 459 COLLINS STREET
CHATSWOOD NSW 2067 MELBOURNE VIC 3000
DISTRIBUTION TEL: +61 2 9928 3888 FAX: +61 2 9411 8533 TEL: +61 3 8610 0600 FAX: +61 3 9621 1575

FOR CONSTRUCTION
Drawing No.

S0607-00
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
AS BUILT
R
Connectel
Sundeep Chand 28/02/2019, 8:00:34 pm

S.Chand
................................................

·
·
·

Client: Project: Drawing Title:


HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA SITE SPECIFICATIONS
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-G1 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
RUN HYBRID ON THE
OUTSIDE TRAY GOING
AROUND THE
SHELTER TO LOSE
LENGTH

INSTALLED RRUS
POINTING OUT AS IT
WOULD NOT FIT AS
PER FC

AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:00:42 pm

S.Chand
................................................
Client: Project: Drawing Title:
HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA SITE LAYOUT AND SETOUT PLAN
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-G3 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:00:55 pm

S.Chand
................................................

Client: Project: Drawing Title:


HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA SITE ELEVATION
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-G4 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:01:07 pm

S.Chand
................................................

Client: Project: Drawing Title:


HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA PANEL ANTENNA
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607 SYSTEM CONFIGURATION
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-A1 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:01:14 pm

S.Chand
................................................

Client: Project: Drawing Title:


HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA RF PLUMBING DIAGRAM
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-A2 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
3

AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:01:23 pm

S.Chand
................................................

Client: Project: Drawing Title:


HUAWEI TECHNOLOGIES (AU) PTY LTD MOBILE NETWORK
ABN 49 103 793 380

SYDNEY
LEVEL 6 TOWER B 799 PACIFIC HIGHWAY AUSTRALIA EQUIPMENT SHELTER
CHATSWOOD NSW 2067
TEL: +61 2 9928 3888 FAX: +61 2 9411 8533
MELBOURNE
SITE No:- S0607 LAYOUT PLAN
LEVEL 24 459 COLLINS STREET
MELBOURNE VIC 3000
TEL: +61 3 8610 0600 FAX: +61 9621 1575
MONASH Drawing Status: Drawing No. Revision

Rev Date Revision Details Consultant CAD Designer Verifier Approver McBRYDE CR, WANNIASSA, ACT FOR CONSTRUCTION S0607-F1 A
COPYRIGHT © OPTUS MOBILES PTY LTD ABN 65 054 365 696. ALL RIGHTS RESERVED. VERSION 1.0 SEPTEMBER 2010
AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:01:50 pm

S.Chand
................................................
AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:01:59 pm

S.Chand
................................................

FOR CONSTRUCTION
MOBILE NETWORK
AUSTRALIA
VISIONSTREAM PTY LTD
236 East Boundary Road
2 North Drive Virginia Park Bentleigh East VIC 3165
OPTUS STANDARD
Tel- (03) 9258 5700 Fax- (03) 9563 7481 DRAWING
www.visionstream.com.au OSD-170 B
MERCS SIGNAGE
SIGN SIGN SIZE /
SYMBOL LOCATION FIXING METHOD
NAME IMAGE MATERIAL
1. INSIDE ROOFTOP ACCESS DOORS OR ON BUILDING FACADE (NEED OWNER'S APPROVAL) IF
EWP ACCESS ONLY. CONSULT SAE FOR ANY COMMUNITY SENSITIVITIES. CENTRE OF SIGN TO BE 1500mm ABOVE FLOOR LEVEL AND 400mm FROM DOOR EDGE. AFFIXED VIA SCREW-FIXED,
400H x 350W RIVETED OR SELF-ADHESIVE.
2. AT BOUNDARY OF CONTROLLED AREA (ROOFTOP EXCLUSION ZONES DEFINED BY HANDRAILS,
METAL OR
SAFETY CHAINS, BALLARD, SHROUDS ETC). CENTRE OF SIGN TO BE 1500mm ABOVE BASE OF MONOPOLE. AFFIXED VIA STEEL STRAPS OR WEATHERPROOF ADHESIVE.
MERCS-1 SELF ADHESIVE
(RF HAZARD AREA S1 3. ON MONOPOLE FACE (DIRECTLY BELOW CLIMBING PEGS /LADDER AND FALL ARREST SYSTEM). CENTRE OF SIGN TO BE 1500mm ABOVE BASE OF TOWER LEG. AFFIXED VIA STEEL STRAPS (NOT OBSCURING SIGN OR
SIGN) 200H x 175W SCREWED) TO STEEL BRACKET.
4. ON INSTALLATIONS SUCH AS LIGHTING COLUMNS I POLES AT SPORTING VENUES, PARKS,
METAL OR CENTRE OF SIGN TO BE AT LEAST 3m BELOW ANTENNAS OR DISHES AND MIN. 5m ABOVE THE BASE OF THE STRUCTURE.
RESERVES ETC.
SELF ADHESIVE
5. ON LATTICE TOWER LEG (DIRECTLY BELOW CLIMBING PEGS /LADDER AND FALL ARREST ONE SIGN PER CLIMBING ACCESS POINT.
SYSTEM).

This is a telecommunications
ON ALL TOWER AND MONOPOLE FACILITIES - FIXED TO SITE ACCESS GATES. CENTRE OF SIGN TO BE 1500mm ABOVE GROUND LEVEL AND 400mm FROM PADLOCK SIDE OF DOUBLE ACCESS GATES.
MERCS-2 facility. For information about

AS BUILT
this site visit www.rfnsa.com.au
180H x 250W
(MCF INFORMATION S2 Or contact the facility manager.
METAL MAY BE INSTALLED ON ROOFTOP ACCESS DOORS THAT ARE NOT RESTRICTED ACCESS FOR SINGLE ACCESS GATES, LOCATE SIGN 400mm FROM PADLOCK SIDE ON FIXED FENCING ADJACENT THE ACCESS GATE.
SIGN) NSA Site Number: _______
(i.e. DOORS THAT DO NOT HAVE MERCS-1 SIGNAGE INSTALLED). SIGN TO BE FIXED VIA STAINLESS STEEL OR CORROSION RESISTANT CABLE TIES.

Connectel
400H x 350W
METAL OR NEAR AREAS THAT EXCEED PUBLIC EXPOSURE LIMITS IN A CONTROLLED AREA (e.g. WALKWAYS
MERCS-3 SELF ADHESIVE SIGN TO BE INSTALLED AT ENTRY POINT TO CONTROLLED AREAS (ESPECIALLY ON LARGE ROOFTOPS WITH MULTIPLE
PASSING IN FRONT OF TRANSMITTING ANTENNAS OR DISHES).
ACCESS POINTS OR POOR ACCESS RESTRICTION) - ON HANDRAIL, SAFETY CHAIN, BALLARD, SHROUD OR WALL.
(GENERAL PUBLIC S3 IF BARRIERS ARE REQUIRED, LOCATION OF BARRIERS (E.G. CHAINS) AND SIGN TO BE SHOWN ON
RF HAZARD SIGN) 200H x 175W SIGN TO BE FIXED VIA FIXING SCREWS OR WEATHERPROOF ADHESIVE.
METAL OR FC DRAWING. NEED OWNER APPROVAL FOR THE BARRIERS.
SELF ADHESIVE
Sundeep Chand 28/02/2019, 8:02:05 pm

S.Chand
400H x 350W
METAL OR NEAR AREAS THAT EXCEED OCCUPATIONAL EXPOSURE LIMITS IN A CONTROLLED AREA (e.g. EME SIGN TO BE INSTALLED AT ENTRY POINT TO CONTROLLED AREAS (EITHER SIDE OF CLIMBING BARRIERS ON
MERCS-4 SELF ADHESIVE EXCLUSION ZONES ON GROUND WITHIN COMPOUNDS OR ON STRUCTURES CAUSED BY STRUCTURES OR ON SMALL DIAMETER FREE-STANDING POLE ON GROUND EITHER SIDE OF EXCLUSION ZONES).
(OCCUPATIONAL
RF HAZARD SIGN)
S4
200H x 175W
METAL OR
TRANSMITTERS NEARBY).
IF BARRIERS ARE REQUIRED, LOCATION OF BARRIERS (E.G. CHAINS) AND SIGN TO BE SHOWN ON
................................................
SIGNAGE ON STRUCTURES IS NOT TO IMPEDE OPERATION OF FALL ARREST SYSTEM.
SIGN TO BE FIXED VIA SCREWS, RIVETS OR STEEL STRAPS.
FC DRAWING. NEED OWNER APPROVAL FOR THE BARRIERS.
SELF ADHESIVE

CENTRE OF SIGN TO BE INSTALLED ON REAR OF PANEL ANTENNAS AND AT BASE OF OMNI ANTENNA MOUNTS,
REQUIRE ON BACK OF EACH PANEL ANTENNAS ON ROOFTOP SHARED FACILITY. PREFERABLY 1500mm ABOVE NORMAL ACCESS (ROOF) LEVEL.
100 x 100 x 100
MERCS-5 SIGN TO BE SELF-ADHESIVE TO BACK OF PANEL ANTENNAS.
SELF ADHESIVE
(TRANSMITTING S5
ANTENNA SIGN) ALTERNATIVELY INSTALL SIGNAGE FOR NON-EME AWARE ROOFTOP WORKERS WHERE THEY SIGN TO BE INSTALLED MOUNTING POLE OF ANTENNA SO THAT IT'S VISIBLE FROM NORMAL ACCESS (ROOF) LEVEL
200 x 200 x 200
METAL MAY INADVERTENTLY ACCESS AN EME OVERHEAD HAZARD ZONE ON FOOT, OR VIA ACCESS (e.g. ROOF EDGES IN THE VICINITY OF TRANSMITTING ANTENNAS OR DISHES INSTALLED ABOVE).
LADDER, EWP ETC. SIGN TO BE FIXED VIA SCREWS OR RIVETS TO MOUNTING POLES OF PANEL ANTENNAS.

110H x 200W SIGN TO BE INSTALLED AT REAR OF DISH HEAD UNIT OR RADIO UNIT FACING IN THE DIRECTION FROM WHICH ROOFTOP
MERCS-6 SELF ADHESIVE REQUIRED ON ALL ROOFTOP SHARED FACILITIES TO IDENTIFY LOW POWER TRANSMITTING VISITOR WOULD MOST LIKELY APPROACH. SIGNAGE SHOULD NOT IMPEDE DISH OPERATION OR COOLING.
(TRANSMITTING S6 MICROWAVE ANTENNAS (DISHES). THESE TRANSMITTERS EME EXCLUSION ZONES ARE
DO NOT INSTALL SIGNAGE ON FRONT OF DISHES.
MICROWAVE SIGN) 55H x 100W CONTAINED WITHIN THE DIAMETER OF THE ANTENNA (i.e TRANSMIT LINEALLY FROM WITHIN).
SELF ADHESIVE THIS SIGNAGE DOES NOT APPLY TO GRIDPAK ANTENNAS.

THIS TABLE IS BASED ON MOBILE CARRIERS FORUM (MCF) DOCUMENT


'FACILITY RF EME SIGNAGE - 7.1.01 PREFERRED SITE SIGNAGE'
AND COMPLIES WITH ARPANSA's RADIATION PROTECTION STANDARD (RPS3) [1]
REFER TO DRAWING OSD-170, OSD-180 & OSD-190 FOR GUIDANCE ON LOCATION OF SIGNAGE.
Client: Project: Drawing Title:

MOBILE NETWORK
AUSTRALIA OPTUS EME SAFETY SIGNAGE
VISIONSTREAM PTY LTD
25-37 Huntingdale Road REQUIREMENTS
Burwood VIC 3125
Australia
OPTUS STANDARD Sheet Size Scale Drawing No. Revision
Tel- +61 3 9273 7600
Rev Date Revision Details Consultant CAD Designer Verifier Approver www.visionstream.com.au DRAWING A3 1:1 OSD-191 A
Reza Parvazi 3 December 2018
Axicom Services 87039/11568494/1

Monash (ACT) – Mount Certificate


VHA: Monash-O 27302

Reza,

I refer to the Axicom Services email of 19-Nov-2018 with your request for mount certification for the
VHA proposal on the Axicom owned pole structure at the Monash site in ACT.

BRIEF

The requirement is to assess and certify the structural adequacy of the existing collar mount to
support the Optus installation at the Monash site.

DESIGN CRITERIA

Site Address : McBryde Crescent, Wanniassa, ACT 2903


Geographic Co-ordinates : 35.403577 S, 149.093510 E (GDA94)

Structure : 25m Koppers pole


Basic Wind Speed : 45m/s (V500)
Serviceability Wind Speed : 27m/s (Vs)
Topographic Multiplier : 1.0
Wind Direction Multiplier : 1.0 (Varies)
Terrain Category : 2.8 (Varies)
Region : A3
Structure Classification : Importance Level 2

Design Loads : Dead & Wind Loads on antennas and mounting steelwork.
Design Standards : AS/NZS 1170.0-2002, AS/NZS 1170.2-2011, AS 4100-1998.

AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:02:13 pm

S.Chand
Privacy Statement: We respect your privacy. Any personal information which we collect about you will be collected and used in the ordinary
course of business so we can offer and provide our services. Further details about how we handle your personal information, including access

HEAD OFFICE
................................................
procedures, are available in our privacy policy at www.structel.com.au. Alternatively, please contact us to discuss further.

SYDNEY OFFICE
Level 16, 360 Elizabeth Street T +61 3 9633 1300 Level 1, 110 Pacific Highway structel.com.au
Melbourne VIC 3000 F +61 3 9654 8448 St Leonards NSW 2065 ABN 73 064 274 835
Mount Certificate: MONASH (ACT) 2

EQUIPMENT MOUNTING

It is proposed to install 3 × new Commscope Combiners behind the existing panel antennas and 12 ×
new Huawei RRUs, as listed below, on the existing mounting pipe as per drawing VPL-STD-S133, Rev.
B, attached to the existing horizontal rails with Plate ‘C’ from Visionstream standard drawing VPL-STD-
S158, Rev. A.

One of the proposed RRU mounting pipes appears to have a U-Bolt missing from Plate ‘C’ from
Visionstream standard drawing VPL-STD-S158, Rev. A. It is required that this be rectified and that all
mounting pipes are inspected before proceeding with the proposed installation.

The existing as-built headframe drawings have not been provided. The existing headframe appears to
be similar to a standard 3-piece collar headframe as per Leighton drawing 92013-39 with
strengthening installed as per Structel drawing STD-3451, Sheet 1, Issue 1.

The headframe assessment has been based on photos along with the drawing listed above and the
existing and proposed loading arrangement.

The existing equipment mounting steelwork is presumed to be in good, sound and well maintained
condition.

Structel certifies that the existing antenna mounting steelwork with the newly detailed Optus
mounting pipes can safely accommodate the proposed antenna and ancillary loading arrangement,
when assessed in accordance with the relevant Australian Standards.

AS BUILT
Connectel
Sundeep Chand 28/02/2019, 8:02:18 pm

S.Chand
................................................

87039/11568494/1
Mount Certificate: MONASH (ACT) 3

EQUIPMENT INCLUDED IN ANALYSIS

Manufacturer Model Quantity Type Height (m) Azimuth (°)


Argus RV4PX310R 2 Panel 24.4 0
Argus RV4PX310R 2 Panel 24.4 110
Argus RV4PX310R 2 Panel 24.4 220
Nokia AEQF 1 Panel 23.9 0
Nokia AEQF 1 Panel 23.9 110
Nokia AEQF 1 Panel 23.9 220
Andrew E15R02P28 3 Amplifier 24.0
Andrew E15V90P43 6 Combiner 23.4
Commscope E14F60P07 3 Combiner 24.4
Huawei RRU3971 6 Remote Radio Unit 25.2
Huawei RRU3952 3 Remote Radio Unit 25.2
Huawei RRU3953 3 Remote Radio Unit 25.2
Nokia NSN FZNI 3 Remote Radio Unit 25.3
Nokia NSN FXEB 2 Remote Radio Unit 24.8
Nokia NSN FRGT 2 Remote Radio Unit 24.8
Andrew 1/2" 48 Tail 25.2
Huawei AAU5711 (Future) 1 Panel 25.4 0
Huawei AAU5711 (Future) 1 Panel 25.4 110
Huawei AAU5711 (Future) 1 Panel 25.4 220
Andrew E15R02P30 (Future) 3 Amplifier 24.4
CommScope E11F13P25 (Future) 3 Combiner 25.4
Commscope E14F60P07 (Future) 3 Combiner 24.4
Huawei RRU3929 (Future) 6 Remote Radio Unit 25.1
Huawei RRU3806 (Future) 3 Remote Radio Unit 24.2

AS BUILT
Should you have any questions regarding the above information, please do not hesitate to contact me
on (03) 9633-1328.

Regards,
Connectel Approved:

Kirk Christakakis Sundeep Chand 28/02/2019, 8:02:26 pm


Steven Costin

S.Chand
................................................
BE (Civil), MEngSc, MIEAust,
CPEng, NER 1089385

Intellectual Property: The contents of the report plus any attachments contain privileged and confidential information in response to a specific request from our
client or their agents. The report is not exhaustive in its scope and shall not be used in whole or in part for any purpose, other than the intended purpose. The report
may not be reproduced or forwarded in any way to any other party without the express written permission of Structel. Any subsequent changes to the report,
including additions and amendments, must be referred to Structel for review and final approval to ensure a consistent design philosophy.

87039/11568494/1