Professional Documents
Culture Documents
Private & 1/
Confidential
Failed Items 1 failed
1.1 Have you logged onto site with GDC on 1800 683 683 ? Yes
Optus reporting High RTWP issue on U900 sector 2 issue on site 27073_ Centennial Avenue -V OVL: 37391
IM125810
2.2 Fault Start Date / Time 27th Oct, 2020 10:00 AM AEDT
levels on arrival =
FXDB 1.1.1 ANT 3 -100.5.
FXDB 1.1.1 ANT 4 -82.2
Load test after internal LB
combiner FXDB 1.1.1 ANT 3 -101.9
FXDB 1.1.1 ANT 4 -111.4
PIM test from output of Combiner with antenna as
load. FAIL -88.8dBc
PIM test from output of Combiner with load before
TMA PASS -165.9dBc
PIM test from output of Combiner with load on output TMA
PASS -157.6 dBc
PIM test from output of Combiner and by-pass TMA with antenna as load.
FAIL -103.5dBc
Port swap A B leg at antenna to prove faulty port. Fault stay with port, fault now on A leg.
Faulty antenna cause of High RTWP. Antenna replacement required.
N/A
N/A
2.8.4 How long is the Traffic Control required for – 2/4/6/8/10/12/… 6 hours
2.11 Attach Test Results (Before and after rectification screen capture as photos)
Photo 7
2.13 if EWP has been used, how many hours of usage – 2/4/6/8/10/12 hrs N/A
Appendix
Photo 1
Photo 2
Photo 3
Photo 4
Photo 5
Photo 7 Photo 6