Summary of Requirement for PWD Toilets (not within an SOU) – as per AS1428.

1-2009

Fixture Aspect and/or Key Requirement Diagram

1900 mm wide x
PWD Toilet Minimum Size NOTE: Extra space may be required to allow for the a washbasin.
2300 mm long

WC Height
460 to 480 mm
(to top of seat)

Centre of WC
450 to 460 mm
(from side wall)

From back wall 800 mm ± 10 mm

Front of WC

From cistern or like Min. 600 mm

Top of WC Seat
Height of Zone
to 700 mm
Toilet Paper
Dispenser
WC Distance of Zone
Max. 300mm
from Front of QC

Height 150 to 200 mm

Width 350 to 400 mm

Backrest Distance above WC


Seat 120 to 150 mm

Angle from Seat Hinge 90° to 100°

Height
Grabrails 800 to 810 mm
(to top of grab rail)

Height
(to top of washbasin)
800 – 830 mm

Centre of Washbasin
Washbasin Min. 425 mm
(from side wall)

Operable Parts of Tap


Max. 300 mm
(from front of washbasin)

Width Min. 350 mm


Mirror
Height Min. 950 mm Not available
(if provided)
Fixing Location / Extent of Mirror 900 – 1850 mm

Height 900 – 1100 mm


Soap / Paper Towel
Not available
Dispenser
Distance from Internal Corner Min. 500 mm
Summary of Requirement for PWD Toilets (not within an SOU) – as per AS1428.1-2009

Fixture Aspect and/or Key Requirement Diagram

Height 1200 – 1350 mm


PWD Clothes Hook Not available
Distance from Internal Corner Min. 500 mm

Height 800 – 830 mm

As vanity bench top Width Min. 120 mm

Depth 300 – 400 mm


Shelves Not available
Height 900 – 1000 mm
As separate fixture
(if within any required Width 120 – 150 mm
circulation space)
Length 300 – 400 mm

Width
Min. 1160 mm
(wall with shower)
Shower recess
Length
Min. 1100 mm
(wall with seat)

Width 390 – 400 mm

Length Min. 1000 mm


Folding seat
Top of Seat Height
470 – 480 mm
(when folded down)

Height
1880 – 1900 mm
(at top of rail)

Vertical Shower Height


1000 – 1100 mm
Rail (at bottom of rail)

Centre
580 – 600 mm
(from nearest side wall)

Shower Height 900 – 1100 mm


(with two walls)
Clearance
Zone for Taps & Min. 50 mm
(from shower rail)
Soap Holder
Distance from wall
300 – 800 mm
(nearest side wall)

Height 800 – 810 mm

Length Min. 600 mm


Grabrail
Start Point
390 – 400 mm
(from side wall)

Length of hose Min. 1500 mm


Shower Hose/Head
Wall outlet position 700 ± 5 mm

Distance from Seat


400 ± 10 mm
(First Hook)
Clothes Hooks (x 2)
Distance from Seat
600 ± 10 mm
(Second Hook)

Height To Table Surface Max. 820 mm


Baby Change Table Not available
(when open) Clearance Underneath Min. 720 mm

Compartment Width 900 – 920 mm

Door clear opening width Min. 700 mm

Pan Height 460 – 480 mm

Height 800 – 810 mm


Ambulant Toilet Grabrails
Location Both sides

Clearance space in front of pan 900mm x 900mm

Coat Hook Height 1350 – 1500 mm

Toilet Paper Dispenser Location As per PWD WC