Emulate 500 Instruction Exceptions PDF
Emulate 500 Instruction Exceptions PDF
COR
Print Answer The COR instruction passes parameters to a Custom Application Routine (CAR) file.
CAR files are not emulated in any way. The instruction is not executed.
Email Answer
IID
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
IIE
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
IIM
(SLC 500 only)
There is no I/O to update, therefore this instruction has no effect.
IIN
There is no I/O image table to update in the software.
The instruction is not executed.
INT
(SLC 500 only)
There is no I/O to trigger an interrupt, therefore this instruction has no effect.
IOM
(SLC 500 only)
There is no I/O to update, therefore this instruction has no effect.
IOT
There is no I/O image table to update in the software.
The instruction is not executed.
MSG
Even though the software provides Data Highway Plus emulation and Channel 0 emulation,
the MSG instruction is not fully emulated.
When an MSG is "executed", the enable (.EN) bit is set during the first scan,
and the done (.DN) bit is set during the second scan.
If you wish, you may use debug files to emulate the data transfer.
1 of 3 7/21/2008 3:27 PM
Emulate 500 Instruction exceptions. http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation...
PID
The software does not attempt to execute the PID instruction or change any of the PID control bits or words.
REF
(SLC 500 only)
There is no I/O to refresh, therefore this instruction has no effect.
RPI
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
SVC
(SLC 500, MicroLogix 1200 and 1500)
There are no processor communications to service, therefore this instruction has no effect.
PTO
(MicroLogix 1200 and 1500 only)
There are no outputs. The instruction is not executed.
PWM
(MicroLogix 1200 and 1500 only)
There are no outputs. The instruction is not executed.
DLG
(MicroLogix 1500 only)
The data logging function is not emulated. The instruction is not executed.
Summary: Emulate 500 Instruction exceptions
Catalog Number:
DocFullNum: A13157497
Revision:N/A
Fixed in Revision:
Package:
Modual:
DISCLAIMER
This knowledge base web site is intended to provide general technical information on a particular subject or subjects and
is not an exhaustive treatment of such subjects. Accordingly, the information in this web site is not intended to constitute
application, design, software or other professional engineering advice or services. Before making any decision or taking
any action, which might affect your equipment, you should consult a qualified professional advisor.
ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY
OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE
DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS
"AS IS." IN NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT,
INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION
HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES.
2 of 3 7/21/2008 3:27 PM
Emulate 500 Instruction exceptions. http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation...
3 of 3 7/21/2008 3:27 PM