You are on page 1of 2

NISE 50-GCIoT Google Cloud IoT Ready i4.

0 IoT Gateway

Main Features
ŒŒ R eady-to-use IoT Gateway to accelerate IoT project deployment ŒŒ Support wired or wireless cloud connectivity via publish-subscribe-
ŒŒ Easy connectivity via IoT studio, drag-and-drop managing data flow based MQTT protocol
ŒŒ Connecting Max. 5 devices via Modbus TCP/RTU protocol for data ŒŒ Open architecture support both Windows-based and Ubuntu-based
acquisition IoT Gateway

Product Overview
NISE 50-IoT series is designed to acquire data from PLCs or devices in the field, and upload or push it to Google Cloud. The NISE 50 GCIoT Ready IIoT
Gateway can also perform simple logic control with its own compute resources. With this acquired data, it can help users improve their process parameters
or predict the machine’s maintenance schedule to reduce down time. IoT-Studio, which is a built-in application, speeds up the development and reduces
time to deployment.

Hardware Specification
Communication Protocols Software Package
ŒŒ odbus TCP
M ŒŒ indows 10 IoT Enterprise 2016 LTSB Entry 64-bit
W
ŒŒ Modbus RTU ŒŒ Ubuntu 14.04.5 64-bit
ŒŒ MQTT ŒŒ IoT Studio with dashboard
ŒŒ OPC UA client ŒŒ OPC UA Server (NISE 50-GCP-UB only)
ŒŒ OPC UA server (NISE 50-GCP-UB support)
Certification
System Configuration ŒŒ CE
ŒŒ I ntel Atom® E3826, 1.46GHz ŒŒ FCC Class A
ŒŒ On-board 2GB DDR3L 1066/1333 RAM ŒŒ UL/cUL
ŒŒ 16G mSATA SSD installed
ŒŒ 3 x mini-PCIe socket for optional Wi-Fi/3.5G modules

System I/O Interface


Ordering Information
ŒŒ TX power on/off switch
A ŒŒ NISE 50-GCIoT (P/N: 10J00005038X0)
ŒŒ 1 x Storage, 2 x GPIO programmable LED Google Cloud IoT Ready i4.0 IoT Gateway
ŒŒ 1 x SIM card holder
ŒŒ 2 x Intel® I210-AT GbE LAN ports Optional
ŒŒ 1 x HDMI display output ŒŒ 24V, 60W AC/DC power adapter w/o power cord
ŒŒ 4 x USB 2.0
(P/N: 7400060033X00) 
ŒŒ 2 x Antenna holes for optional Wi-Fi/3.5G antenna
ŒŒ 3 x COM for DB9 connector

Power and Dimension


ŒŒ P ower input: 24V DC +/-20%
ŒŒ Dimensions: 162mm(W) x 26mm(H) x 150mm(D) without wall-mount
bracket

GCIoT Ready Solution


www.nexcom.com

System Architecture

LAB / QA
East Side BBTs East BBTs West BBTs Pilot BBTs Buffer Transfers Buffer Screen

.ORG
01A 02A 03A 04A 05A
-/-/- 10/09/2030 10/09/2030 10/09/2030 -/-/-
Empty Full Full Full Empty

0.0 0.0 0.0 0.0 0.0


bbls bbls bbls bbls bbls

06A 07A 08A 09A 10A


-/-/- 10/09/2030 10/09/2030 10/09/2030 -/-/-
Empty Full Full Full Empty

0.0 0.0 0.0 0.0 0.0


bbls bbls bbls bbls bbls

Linked to Buffer Tank(s) Next Day Packaging Empty Tank Approved for Packaging Refresh Tank Data

Linked to Packgings(s) Comment Exists for BBT Full Tank Not Fully Tested Approved for Packaging as Critical Blend

Filtration Approved On Hold Back


Linked to Packgings(s) & Buffer Tank(s)

HMI/Local SCADA

Web Interface
Configuration
NISE 50-GCP
Dashboard

PLC PLC PLC PLC PLC

5 Devices Max.

Gateway Feature
Communication Protocols Cloud Connectivity Available
ŒŒ Modbus TCP/RTU ŒŒ G
oogle Cloud IoT Core and Cloud IoT Edge
TCP/RTU
-- Most common communication protocol -- Service of reliable and secure bidirectional
-- Connect up to 5 devices max communications between IoT devices and cloud
ŒŒ OPC UA Client/Server
-- OPC UA Client for getting data from the device
Dashboard UI/HMI Support
SERVER
& CLIENT ŒŒ Dashboard
-- OPC UA Server for access and display data to HMI
-- Quickly create a dynamic data dashboard
(NISE 50-GCP-UB only)
-- Provide variety of widgets for user to directly use via
ŒŒ MQTT
simple configuration
-- A lightweight messaging protocol LAB / QA

ŒŒ Connect to HMI
-- Push data or message to the cloud or database
East Side
East Side BBTs
BBTs East BBTs
East BBTs West BBTs
West BBTs Pilot BBTs Buffer Transfers Buffer Screen

01A
01A 02A 03A 04A 05A
-- // -- // -- 10/09/2014
10/09/2030 10/09/2014
10/09/2030 10/09/2014
10/09/2030 -/-/-
Empty
Empty Full Full Full Empty

0.0
0.0 0.0
0.0 0.0 0.0 0.0
bbls
bbls bbls
bbls bbls bbls bbls

-- Build in OPC UA Server function which provides data


06A
06A 07A 08A 09A 10A
-- // -- // -- 10/09/2014
10/09/2030 10/09/2014
10/09/2030 10/09/2014
10/09/2030 -/-/-
Empty
Empty Full Full Full Empty
.ORG

0.0
0.0 0.0
0.0 0.0 0.0 0.0
bbls
bbls bbls
bbls bbls bbls bbls

Linked to
Linked to Buffer
Buffer Tank(s)
Tank(s) Next Day
Next Day Packaging
Packaging Empty Tank Approved for Packaging Refresh Tank Data

Linked to
Linked to Packgings(s)
Packgings(s) Comment Exists
Comment Exists for
for BBT
BBT Full Tank Not Fully Tested Approved for Packaging as Critical Blend
Back
Linked to
to Packgings(s)
Packgings(s) &
& Buffer
Buffer Tank(s)
Tank(s) Filtration Approved On Hold
Linked

Web Configuration access for SCADA, HMI or controller used


ŒŒ IoT Studio
-- Rapid prototyping/engineering tool
-- With IoT-Studio, user can easy to configure the
NISE50-GCP setting
ŒŒ Remote Access
-- Access and management NISE50-GCP anywhere via
browser
-- Support popular browser based on HTML5 & CSS3

GCIoT Ready Solution


We reserve the right to change specifications and product descriptions at any time without prior notice. Last update: 03/05/2019

You might also like