You are on page 1of 5

OCV Classic 12V

Outdoor Converter 100W & 200W

The big-power eco partner


to drive reliably any
12V solution

• Choose 100W or 200W

5
YEARS • Universal input voltage 100-277 VAC

50.000hrs • IP67 for outdoor applications. Metal


IP67 casing fully encapsulated

• Active Power Factor Correction: ≥0,95

LEDIT YAKI - HQ LEDIT YAKI


Le Lighthouse Rm 2107-2108, Guangzhou Exchange Square
3 allée des Vignes No.268 DongFengZhong Rd
91160 Champlan – France Guangzhou, Guangdong, 510030 CHINA
www.yaki.com www.ledit-yaki.com
info@yaki.com sales@leditinternational.com
OCV Classic 12V
Outdoor Converter 100W

IP67 100-277 V/AC -40°/+50°C

FEATURES & BENEFITS TECHNICAL DATA


▶ SELV 21330032 OCV Classic 100W 12V 100-277V IP67

▶ Full load: 100W at 220V and 70W at 110V Rated supply voltage 100-277 VAC

▶ Active Power Factor Correction over 0.95 at full load Input voltage 90-305 VAC
to allow power distribution at its maximum efficiency
Frequency range 47 - 63Hz
▶ Efficiency over 85%
Power factor PF ≥0.95 at 277 VAC (at full load)
▶ Protection against short-circuit, over temperature, Input
Efficiency
and overload ≥85% at 277 VAC (at full load)

▶ Natural convection cooling AC current(A) ≤0.55A 220VAC/50Hz (full load 100W)

▶ Metal casing fully encapsulated Inrush current Cold star: 60A Max./240VAC

▶ Complies with Class C in the full range load according Leakage current ≤0.7mA at 240VAC

to EN 61000-3-2 Output voltage 12V DC(+/-5%)

Output current 0.1~8.33A at 180~277VAC 0.1~5.83A at 100~180VAC

Output power range 1.2~100W 1.2~70W


DIMENSIONS
Output Voltage range 12.2-12.6V

Output ripple voltage <5% (at full load)

38mm/1,5" Output
Start up time 0-1S / 100VAC, 0-0.5S / 277VAC

Driver will recover when Short circuit condition


Short circuit protection
removed if not damaged.
144mm/5,6"

Over-load protection Yes - (see details in page 4)


169mm/6,6"

110°C±10°C(RTH2) Driver will recover when over-heat


Over-heat protection
condition removed.
160mm/6,3 "

Lifetime 50000Hours at Tc=80°C

Surge
L-N,6KVAC, L(N)-FG,6KVAC
34mm 51mm 63mm impulse test
/1,3" /2" /2,5"
R5mm/0,2" Working Temperature -40°C / +50°C (at full load)
Environment
Storage Temperature -40°C/+80°C, 10-95% RH

LABEL

OCV Classic 100W 12V 100-277V IP67 Code:21330032

100-277V~ = 80ć
Max 0.82A lout
.8.33A /100W (180-277V~)
.5.83A / 70W (100-180V~)
-40~+50℃/full load

www.ledit-yaki.com M M

1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25°C ambient temperature.
2. The LED driver is considered as a component that will be operated in combination with final equipment, since EMC performance will be affected by the complete
installation, the final equipment manufacturers must re-qualify EMC directive on the complete installation again.

Subject to change without notice.


OCV_CLASSIC_12V-DS-UK-2011-v3
2
OCV Classic 12V
Outdoor Converter 200W

IP67 100-277 V/AC -40°/+50°C

FEATURES & BENEFITS TECHNICAL DATA


▶ SELV 21330008 OCV Classic 200W 12V 100-277V IP67

▶ Full load: 200W at 230V, and 150W at 110V Rated supply voltage 100-277 VAC

▶ Active Power Factor Correction over 0.95 at full load Input voltage 90-305 VAC
to allow power distribution at its maximum efficiency
Frequency range 47 - 63Hz
▶ Efficiency over 88%
Power factor PF ≥0.95 at 277 VAC (at full load)
▶ Protection against short-circuit, over temperature,
Efficiency ≥88% at 277 VAC (at full load)
and overload Input
▶ Natural convection cooling Rated current
≤1,1A at 230 VAC 50Hz (at full load 200W)
≤1,9A at 100 VAC 50Hz (at full load 150W)
▶ Metal casing fully encapsulated
▶ Complies with Class C in the full range load according Inrush current
Peak 68A
90% peak 0,302μs
to EN 61000-3-2
Leakage current <0.5mA at 293.6 VAC

Output voltage 12V DC ( +/- 5%)

0,1 - 16,7A at 180 - 277 VAC


Output current
0,1 - 12,5A at 100 - 180 VAC
DIMENSIONS
5 - 200W at 180-277 VAC
Max Output power range
5 - 150W at 100-180 VAC

42,2 mm
1.66’’ Output Output ripple voltage 50mVp-p (at full load)

Start up time 1s at 100 VAC / 0,5s at 277 VAC


197 mm / 7,75’’
233 mm / 9.17’’ Short-circuit protection Yes - (see details in page 4)
215 mm / 8,46’’
Over-heat protection Yes - (see details in page 4)

Over-load protection Yes - (see details in page 4)


4,2 mm
φ5,2/0,2” 0.16’’
35 mm 54 mm 74 mm Surge protection 6KVAC, L-N, 6KVAC, L(N)-FG
1.38’’ 2.13’’ 2.91’’
5,2 mm
0.20’’
Working Temperature -40°C / +50°C (at full load)
Environment
Storage Temperature -40°C/+80°C, 10-95% RH

LABEL

OCV Classic 200W 12V 100-277V IP67 V3 Code:21330008

www.ledit-yaki.com

1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25°C ambient temperature.
2. The LED driver is considered as a component that will be operated in combination with final equipment, since EMC performance will be affected by the complete
installation, the final equipment manufacturers must re-qualify EMC directive on the complete installation again.

Subject to change without notice.


OCV_CLASSIC_12V-DS-UK-2011-v3
3
OCV Classic 12V
Outdoor Converter 100W & 200W
PROTECTIONS NORMS & CERTIFICATES

▶ Short-circuit protection: Driver will recover when ▶ EN 61347-1:2008+A1:2011+A2:2013


short-circuit condition removed if not damaged. ▶ EN 61347-2-13:2014
▶ If driver is overloaded, the voltage will be reduced ▶ EN 62493:2010
and light will decrease, and then it will flash. When
▶ EN 55015:2013
not overloaded it will operate normally.
▶ EN 61547:2009
▶ Excessive Temperature Protection: Driver will switch
off and will restart again when temperature does not ▶ EN 61000-3-2:2014
exceed its limits. ▶ EN 56000-3-3:2013

CABLE

485mm +/- 20mm


19’’ +/- 0,78’’
50mm / 1,97’’ Cables type 100W :
7mm / 0,27’’
L
▶ Input --> Ø 7.4 ±0.2 mm - 3 × 1.0 mm² (19 AWG)
Input : N
7mm / 0,27’’ ▶ Output --> Ø 7.0±0.2 mm - 2 × 1.0 mm² (19 AWG)

70mm / 12,75’’

485mm +/- 20mm


19’’ +/- 0,78’’
35mm / 1,38’’
8mm / 0,32’’

Output :

485mm +/- 10mm


19’’ +/- 0,39’’
50mm / 1,97’’
7mm / 0,27’’
Cables type 200W :
L ▶ Input --> Ø 9 ±0.2 mm - 3 × 1.5 mm² (17 AWG)
Input : N
7mm / 0,27’’ ▶ Output --> Ø 10.2 ±0.2 mm - 2 × 2.5 mm² (12 AWG)

70mm / 12,75’’

485mm +/- 10mm


19’’ +/- 0,39’’
35mm / 1,38’’
8mm / 0,32’’

Output :

Subject to change without notice.


OCV_CLASSIC_12V-DS-UK-2011-v3
4
OCV Classic 12V
Outdoor Converter 100W & 200W
EXPECTED LIFETIME & MTBF

Code Type Expected lifetime MTBF

Ta 40°C Ta 50°C Ta 60°C


21330008 OCV Classic 200W >80,000hrs >40,000hrs >20,000hrs 1,888,300hrs
Tc 65°C Tc 75°C Tc 85°C

*Failure rate below 0.2% per 1.000 hrs

MCB LOAD
Type C10 C16 C20 B10 B16 B20

Installation Ø 1,5mm 2
1,5mm 2
2,5mm 2
1,5mm2 1,5mm 2
2,5mm2

OCV Classic 200W 9 15 20 4 5 9

TOTAL HARMONIC DISTORSION (THD)

Type THD (%) 3 5 7 9 11

OCV Classic 200W 12V 4,6 2,8 2,4 1,8 1,1 0,8

*The values for harmonic distorsion are important and measurable starting at a minimum of 25W. The measurements are done at 230V/50Hz and fully loaded.

PACKAGING

SIZE - LxWxH SIZE - LxWxH Weight Weight Nb of Pcs /


Type
(cm) (ft) (Kg) (lb) box

CARTON OCV Classic 100W 38,7x26x21,5 1,2x0,8x0,7 21 46,2 24

PALLET OCV Classic 100W 120x80x101 3,9x2,6x3,3 756 1666,6 864


H

L
CARTON OCV Classic 200W 26x25,5x23,7 0,85x0,8x0,77 10,8 23,8 8 W

PALLET OCV Classic 200W 127,5x80x86,1 4,2x2,6x2,8 507,9 1120 360

L
W

CARTON PALLET

(When the min and max values are not indicated, the tolerance range for optical and electrical data is ±15 %.)

Subject to change without notice.


OCV_CLASSIC_12V-DS-UK-2011-v3