Dosing System Manual

Customer Technical Service - Engineering

Installation, Commissioning
and Technical Information
for the 5 - 75 L/Hr
Marine Dosing Unit

Innospec Limited
PO Box 17
Oil Sites Road
Ellesmere Port
Cheshire CH65 4EY, U.K.
tel: +44 (0)151 355 3611
fax: +44 (0)151 356 2349

The information contained in this document is provided free of charge and is based on technical data that Innospec believes to be reliable. It is intended
for use by persons having technical skill and at their own discretion and risk. Innospec accepts no liability for any loss, damage or expense arising from, or
in connection with, the use of the information. Furthermore, none of the contents of this publication should be taken as a licence to operate under any
patent, nor as a recommendation to infringe any patent.

5-75 L/Hr Dosing Unit Issue No 1 May 2007


Dosing System Manual

Contents

Description Page No.

System Specifications 3

Functional Description 3

General Layout Drawing 4

Equipment Overview Drawing 5

Parts Listing 6

Electrical Wiring Drawings 7

Injector Layout Drawing 8

Installation Procedure 9 - 10

Commissioning Procedure 10 - 11

Spare Parts 11

Technical Information and dosing graphs 12

5-75 L/Hr Dosing Unit Page 2 of 12 Issue 1 May 2007


Dosing System Manual

System Specifications

Unit Dimensions : 500 (H) x 400 (W) x 300 (D) (mm)

Packaged Dimensions: 600 (H) x 500 (W) x 400 (D) (mm)

Packaged Weight : ~ 42 Kg’s

Power Supply : 115 – 230 – 400 – 440 VAC 50/60 Hz

Nom. Back Pressure: 2.0 Barg

Maximum Back Pressure : 4.0 Barg at 50 Hz; 3.5 Barg at 60 Hz

Functional Description

The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system
should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil.
As an alternative the system can dose into the suction filter of the transferpump, for automatic
Start/Stop an optional External Start/Stop cabinet has to be installed.

To test the dosing pump or to bleed the system, see under part commissioning (page 10 – 11).

ALWAYS ENSURE THAT THE CORRECT VOLTAGE IS CONNECTED!


Power Supply: 115 – 230 – 400 – 440 VAC; 50/60 Hz.
The selection switch (12) on switch cabinet (11) has to be set accordingly.

5-75 L/Hr Dosing Unit Page 3 of 12 Issue 1 May 2007


Dosing System Manual

General Lay-Out Drawing

5-75 L/Hr Dosing Unit Page 4 of 12 Issue 1 May 2007


Dosing System Manual

Equipment Overview

5-75 L/Hr Dosing Unit Page 5 of 12 Issue 1 May 2007


Dosing System Manual

Equipment List

ITEM QTY DESCRIPTION TYPE ARTICLE CODE

1 1 Dosing pump DMX 75-4 221-75-10198 GRU-DMX75-4PVT

2 1 Flow counter VZO 8 VIT-9263000

3 1 Bleed valve Ball valve 8 mm ALA-74500808

4 1 Check valve spring loaded Check valve 10 mm; 1 barg SO-47321-10-1 bar

Injector 1/2"x1/2" Check AQ-10700200 +


5 1 Injector with check valve assembly
valve 1/2"; 1 barg SO-7300-1/2”-1 bar
HYD-1271983-100+TEE-
6-7 1 Suction assembly AQ-10700XXX
21042300+AQ-10700185
AQ-10700111+GEH-
8 1 Drum closer + Quick connector AQ-107000XX
940206+GEH-940106VIT

9 1 Drum Breather Breather 3/4" AQ-10700070

Main switch 3 Phase 20


10 1 Main switch in box SOL-5960892
Amp Ye/Rd

11 1 Switch cabinet incl. transformer CI2216A + WEC-30000020 AQ-1070XXXX

12 1 Selection switch M220 61070 219M1 SOL-5960170

5-75 L/Hr Dosing Unit Page 6 of 12 Issue 1 May 2007


Dosing System Manual

Electrical Wiring Drawings

5-75 L/Hr Dosing Unit Page 7 of 12 Issue 1 May 2007


Dosing System Manual

Injector Layout Drawing

5-75 L/Hr Dosing Unit Page 8 of 12 Issue 1 May 2007


Dosing System Manual

Installation Procedure
Securely mount the dosing cabinet, using the fixing brackets supplied, to a suitable location in the vicinity of the
fuel transfer pumps.

Ensure that the Octamar™ product drum is secured tightly to the ship build so free movement is
not possible.

SECURE
THE
OCTAMAR™
PRODUCT
DRUM

Assemble the suction, bleed and discharge hoses using the components as shown in the Equipment
Overview (page 5).

5-75 L/Hr Dosing Unit Page 9 of 12 Issue 1 May 2007


Dosing System Manual

A. Connect the pump suction side with flexible hose to the suction assembly and drum closer with
suction filter (6, 7, 8).
Note: The suction hose should be kept as short as possible (2 metres).

B. Mount the suction hose with suction assembly, drum-closer and suction filter to the product drum.

Note: Ensure that the drum-closer is screwed in completely so that the suction valve and filter will
hang 1 cm above the bottom of the drum.
Important: The vertical distance (height) between pump unit and bottom of the product drum must
not exceed 2 meters (6,5 feet).

C. Connect the pump discharges with flexible hoses to the injection assembly and fit the injection nozzle in the
main bunkerline.

D. Connect the short air bleed hose and place a small container beneath the outlet from the bleed discharge.

E. Connect a power supply cable to main switch in box (10). The power supply is 2 phases 115 or 230 or 400
or 440 VAC 50/60 Hz. The power supply is connected directly to the main switch at terminal 1 and 3 and
Earth (PE).

F. Before powering up the system check if the selection switch (12) is set at right voltage level.

Commissioning Procedure
The INNOSPEC Marine dosing system is designed to dose into the ship’s main bunkerline. The system
should be switched ON at start bunkering and switched OFF at end of bunkering of fuel oil.
As an alternative the system can dose into the suction filter of the transferpump, for automatic
Start/Stop an optional External Start/Stop cabinet has to be installed.
Prior to putting the dosage unit into service, the system has to be primed and bled of air. After priming
of the unit is completed, setting of the correct chemical dosage rate (flow rate in L/hr) will also be required. You
will be informed of the recommended flow rate for your installation prior to commissioning.
Please follow the instructions below.

A. Make sure all connections are tight.

B. Make sure the dosing system is switched ON at main switch (10).

C. Make sure the stroke length of the dosage pump is set at 100%. This is the large knob on the pump
console. Unscrew the locking screw before turnig the knob.

D. Open the air bleed valve (3)

5-75 L/Hr Dosing Unit Page 10 of 12 Issue 1 May 2007


Dosing System Manual

E. After a few minutes, chemical will discharge from the air bleed hose.

F. When there is a constant flow of chemical from the air bleed hose, shut air bleed valve (3).

G. Adjust the flow rate with the large knob on the pump. See dosing graph on page 12. The knob can be set
from 0 – 100 % and is locked tight using a locking screw. Loosen this screw before altering the setting.
Tighten the screw after setting of the desired flowrate. The flow rate can be checked with the flow counter
(2).

H. Switch OFF the power to the dosage unit and close the panel door.

Note: Re-priming of the pump may be necessary after changing the product drum and/or if the pump and hoses
are disconnected for maintenance or repair.

Spare Parts
If spare parts are required, please contact your nearest Innospec Marine Specialties office. Address
and contact details are on the inside of the cabinet door.
Please quote the pump serial number, the system serial number and item(s) you require. Please also
refer to the parts listing shown in the Equipment Overview Drawing and Parts Listing on page 5 - 6 of this
manual.

USA Europe, Middle East, Africa

Innospec – Marine Specialties Innospec – Marine Specialties


Customer Service Centre - USA Customer Service Centre - EMEA
8375 South Willow Street P.O. Box 53156
Littleton, CO 80124 CY-3301 Limassol
USA Cyprus
Tel: +1 800 441 9547 Tel: +357 25 762 535
Fax: +1 303 792 5668 Fax: +357 25 762 545
e-mail: csc.americas@innospecinc.com e-mail: csc-emea@global.innospecinc.com

Greece/Turkey Asia Pacific


Innospec Hellas Ltd. Innospec – Marine Specialties
Marine Specialties Customer Service Centre - Asia Pacific
Customer Service Centre - Greece & Turkey 47 Scotts Road, #02-03 Goldbell Towers
11, II Merarchias Street Singapore 228233
185-35 Piraeus Tel : +65 6336 6286
Greece Fax : +65 6336 1692
Tel: +30 210 411 0727 / 8 e-mail: csc-asiapacific@sg.innospecinc.com
Fax: +30 210 411 0748
e-mail: csc-gt@global.innospecinc.com

5-75 L/Hr Dosing Unit Page 11 of 12 Issue 1 May 2007


Dosing System Manual

TECHNICAL INFORMATION

Grundfos Alldos Primus 221 75-4 Motor Driven Dosing Pump

Note: The pump has been calibrated to operate between 5-75 litres per hour.

The Grundfos Alldos manual is attached for reference.

5-75 L/Hr Dosing Unit Page 12 of 12 Issue 1 May 2007