You are on page 1of 1

Required minimum wall thickness for Meghnaghat HRSG

Table 1, Calculated minimum wall thickness (mm)


Design condition Factor "I" DEE Calculation (depanding on MWT+Mill tolerance)
Tn for tm for tm for
straight Extrados Extrado
Intrados Intrados 1.5DR *1 1.5DR
OD OD tm for including s Ordering thinning (Extra) thickening (Intra)
No MATERIAL "I"
(inch) (mm) Temp. P SE A Straight Mill "I" + Mill
y Ratio Tolerance
(F) (psig) (psig) (mm) tolerance
+ 12.5% *2
1.5D 1.5D mm "f-e" mm "h-g"
1.5D 1.5D % "f" +: OK % "h" +: OK
"e" "g"

SA335
1 14 356 1135.0 2930 9620 0.7 1.6 46.2 52.84 43.3 59.7 52.84 17% 43.9 0.5 66.0% 88.0 28.3
P92
0.88 1.25
SA335
2 16 406 1134.0 2799 9688 0.7 1.6 50.4 57.64 47.2 65.2 57.64 17% 47.8 0.6 66.0% 96.3 31.1
P92

*1 Base on the wall thickness prior to bending is MWT (worst case, thinniest wall thickness)

*2 Same ordering thickness for 1.5DR

Worst Extrados on 14"


1.5D : "f", ??mm > "e", ??
mm
Worst Extrados on 16"
1.5D : "f", ??mm > "e", ??
mm

Intrados on 14"
1.5D : "h", ??mm > "g", ??mm
Intrados on 16"
1.5D : "h", ??mm > "g", ??mm

You might also like