SERVICE EQUIPMENT (Air Conditioning System)

The manifold set consists of three fittings to Vapor Cycle Air Conditioning Temperature is
which the service hoses are attached, two hand a measure of the effect of heat on a body or
valves with O-ring seals, and two gauges, one material, and is a convenient way of expressing
for measuring the pressure in the low side of the this physical phenomenon numerically.
system and one for the pressure in the high
side. Transfer of Heat - heat is a form of energy, and
can neither be created nor destroyed. Any
The low-side gauge is a compound gauge, material that allows this transfer easily is said to
meaning that it will read pressure on either side be a conductor of heat, while any material that
of atmospheric pressure. impedes the transfer is called an insulator.

The high-side gauge is a high-pressure gauge Refrigerant almost any volatile liquid can be
that has a range of from zero up to around 600 used as a refrigerant, but for maximum
psi, gauge pressure.  effectiveness, it must have a very low vapor
pressure and therefore a low boiling point.
The manifold connects the gauges, the valves,
and the charging hoses. Refrigeration Oil since the air-conditioning
system is completely sealed, the oil used to
Refrigerant source the refrigerant used in
lubricate the compressor seals and expansion
aircraft air-conditioning systems has, until
valve must be incorporated within a sealed a
recently, been Refrigerant-12 (R-12).
system.
Vacuum Pump Just a few drops of water is all
The receiver-dryer is the reservoir for the
that is necessary to completely block an air-
system and is located in the high side between
conditioning system.
the condenser and the expansion valve.
Leak Detector The continued operation of an
The thermal expansion valve is the control
air-conditioning system depends upon the
device which meters the correct amount of
system maintaining its charge of refrigerant, and
refrigerant into the evaporator.
all of the charge can be lost to even a tiny leak.
Internally equalized thermal Valve is
A common type of leak detector used in
controlled by the amount of heat in the
automotive air conditioning and commercial
evaporator.
refrigeration service is a propane-burner-type
detector. The torch type leak detector is Externally equalized expansion valve
definitely NOT RECOMMENDED for use with an equalizes temperature against high-side
aircraft air-conditioning system, because of the temperature.
danger of an open flame around the aircraft.
The evaporator is the actual cooling unit in a
The most acceptable type of leak detector for vapor-cycle air-conditioning system.
aircraft air-conditioning servicing is an
electronic oscillator that produces an audible The compressor circulates the refrigerant
tone. through the system. Aircraft air-conditioning
systems usually use reciprocating-type
Basic Operation (Vapor Cycle compressors.

Cooling System) The condenser is the radiator-like component


that receives the hot, high-pressure vapors from
the compressor and transfers the heat from the
refrigerant vapors to the cooler air flowing over Ram Air Door - some aircraft are equipped with
the condenser coils. a ram air door to allow cool outside air to
ventilate the cabin with fresh air during
FUNDAMENTALS OF CABIN unpressurized flight.

COOLING SYSTEM Cabin Temperature Pick-up Unit Normally,


temperature sensors are located in each
Air Cycle Air Conditioning In a jet transport passenger zone in the aircraft's cabin for the
aircraft, hot compressor bleed air is taken from purpose of controlling the zone temperature.
the engine compressors. The air-cycle machine The cabin zone controller uses the sensed
and its associated components are often difference between the temperature demand
referred to as a "pack." signal from the selector and the actual supply
temperature to position the associated air mix
The air-conditioning shutoff valve, often called
valve.
the pack valve, is used to control the flow of air
into the system.

The primary heat exchanger is a radiator


through which cold ram air passes to cool the
hot bleed air from the engines.

Air Cycle Machine BYPASS VALVE When


cooling requirements are low, some or all of the
hot bleed air from the engines can be bypassed
around the ACM (the compressor and turbine) if
warm air is needed in the cabin.

Secondary Heat Exchanger As cooling


requirements increase, air exiting the primary
heat exchanger is routed to the compressor 
side of the ACM. This heat exchanger provides
an additional stage for cooling the hot engine
bleed air after it has passed through the primary
heat exchanger and the compressor of the ACM.

Some systems use a refrigeration bypass


valve to keep the temperature of the air exiting
the ACM from becoming too cold.

Refrigeration Turbine Unit Pressure and


Temperature are interchangeable forms of
energy.

Water Separators The rapid cooling of the air in


the turbine causes moisture to condense in the
form of a fog, and when this foggy air passes
through the water separator, the tiny droplets of
water coalesce in a fiberglass sock and form
large drops of water.