ES16

BASIC

CTS VN
COMMITTED TO SUSTAINABLE PRODUCTIVITY

We stand by our responsibilities towards our customers,


towards the environment and the people around us.
We make performance stand the test of time. This is what
we call – Sustainable Productivity.
3

ES 2015 – USER INTERFACE


Status of AIRNET
Single Airnet View Access Logscreen
Settings

Current profile
Pressure graph: Current SPS + Shortcut
- Scale is automatically adjusted + Shortcut

Airnet ES savings (ES360


only)
Shortcut to energy savings

Total flow capacity


used

Airnet measurements
4

Minimize the screen:


ES 2015 – USER INTERFACE Settings
Go to windows
Multiple Airnet View
Status of ES
Navigation bar

Combined ES
savings (ES360)

3 airnets with their


pressure graph (ES360)

Measurements
list
Go to single airnet
screen
5

ES 2015 – USER INTERFACE


Logscreen
List can be sorted on any field
6

ES 2015 – USER INTERFACE


Compressor Status
Symbol of regulating PI control
compressor
LNL (Bang-Bang) Up to 8 devices

Flow capacity used of control


compressor
ZH: IGV% and BOV%

Status of
compressors

Integrate / isolate button


Touch to go to Detail
screen
7

ES 2015 – USER INTERFACE


Symbols

: Warning on this compressor


: No communication
: Service needed
: Shutdown
: Compressor is integrated
: Compressor is isolated (LAN Control A)
: Isolated but cannot be integrated
- Airnet in local control
- Elektronikon not in LAN Control
8

ES 2015 – USER INTERFACE


Compressor Details
Device measurements

Integrate / isolate button

Local settings from


Elektronikon
9

ES 2015 – USER INTERFACE


Historical Graphs Detailed time
Compressor/Dryer/Airnet
selection fields
All Measurements

Fast time selection


fields
10

ES 2015 – USER INTERFACE


Energy Savings
Status Breakdown

ES 360 simulates the installation in local control.

Total flow delivered

Pressure:
Yellow = local simulation
Green = actual
11

ES 2015 – USER INTERFACE


Settings Menu

Pressure bands for each airnet


Profiles for each airnet
Automatic functions for ES360 (e.g. ARAVF)
Rules (Optimized/Baseload/Standby)
PLC Rules (not shown) – enable/disable PLC Editor program
User Management for ES360 (e.g. passwords, access)
User Preferences (e.g. language, units)
Information of the ES360 (e.g. ES serial number, IP Address, Licence)
12

ES 2015 – USER INTERFACE


Pressure Bands

Pressure Band editing


– Schedule (e.g. Manual, Weektimer)
– When changing the pressure band, the
ES uses a transition dp/dt (only
set in WizAir)

Up to 10 pressure bands
Create new pressure bands
– Customize name
– Pressure band
– Setpoint
– Warning levels
– Shutdown levels
13

ES 2015 – USER INTERFACE


Profiles

Profile Schedule
– Manual
– Periodical
– Weektimer (different weeks possible)
– Based on flow

Fixed profiles
– Local control
– Central stop
– Energy saving

Custom profiles
14

ES 2015 – USER INTERFACE


Profiles

– Manual
– Periodical
– Weektimer (different weeks possible)
– Based on flow
15

ES 2015 – USER INTERFACE


Profiles

Custom Profile
– Insert groups
Name of group can be customized
Insert subgroup if needed
Add units to this groups
– After all units are put into groups, select schedule for each group with following mode
Cost optimization
Equal wear
Energy saving
Forced sequence
– Over the different groups there is also a schedule
– Each schedule mode can be changed
Manual
Periodical
Weektimer (different weeks possible)
Based on flow
16

ES 2015 – USER INTERFACE


Profiles

Name profile

Group 1 runs in Forced


Sequence

Edit button to change


the mode for this group

Insert subgroup.
Insert units.

Insert group
17

ES 2015 – USER INTERFACE


Automatic Functions

Automatic Integration
– After Voltage Failure
– After recovering from communication loss
– After recovering from Not Responding
– After resetting an E-Stop
– After selecting LAN Control on Elektronikon

Automatic Recovery
– High/Low ES Pressure Shutdown

Can be limited by timers


18

ES 2015 – USER INTERFACE


Rules

Spare Capacity
– Minimum amount of available flow in
unload state
– Use upload flow = include available
VSD capacity of any running VSD’s

Assign Optimized/Baseload/Backup
19

ES 2015 – USER INTERFACE


User Management

User Access
– integrate/isolate machines
– select pressure settings
– edit pressure settings
– select profile settings
– select central stop
– enable/disable rules
– edit automatic function settings
– edit user settings

Administrator – access to All


Passcode = 4-digits