Job No: 2015-0075

Sheet No: 1
Designed by: KAM Checked by: KH TANN Date: 5/6/2019
Title:

FOOTING CALCULATION

1.0 Design Parameters

b = 400 mm , width of footing


l = 400 mm , length of footing
d = 400 mm , depth of footing
EN 1992 1-1
Af = 160000 mm2 , Area of footing (3.15)
EN 1992 1-1
2
fck = 20 N/mm , compressive strenght of Concrete
2
fyk = 460 N/mm , yield strength of steel
2
fcd = 0.85 Fck = 11.333 N/mm Table 3.1
1.5
fyd = fyk = 400 N/mm2
1.15
3
gc = 25 kN/m , Unit weight of Concrete
fctm = 2.9

2.0 Design Forces Hoarding Panel


Thickness of Hoarding sheet = 0.625 mm

Unitl Weight hoarding Panel = 78*0.625/1000 kN/m2


= 0.0488

Total Structural Weight = 0.0488*3*2.5 kN


= 0.366 kN

2
0.1 kN/m2 Wind load = 0.25 kN/m
rom Staad Analysis
Reactions R1 = 1.88 kN
X1 = 0.256 kN
R2 = -1.11 kN
1.5 m X2 = 0.97 kN

Weight of the Footing = 24*0.4*0.4*0.4 +0.366


= 1.90 kN
Uplift Resistance of Soil = 0.00 kN

Over Design F.O.S = 1.71 > 1.60

R1 R2 Hene ok

A
1.2 m
Consider Fill material
Friction Angle = 30.0 degree
400X400X400 400X400X400 Cohesion = 3.00 kN/m2

Passive Pressure Coffeciant kp = 1+sin ϴ = 3.00


1-sin ϴ

Passive pressure Resistance = 21.60 kN/m2


Max Passive Loading = 4.32 kN > 0.97 kN

Hence ok