Contents

Contents

1 Product Overview 1
1.1 Purpose 1
1.2 Variants 1
1.3 Overview 1

2 Function Description 3
2.1 Maintenance Button 3

3 Technical Data 5

4 DU Interfaces 7

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17


Digital Unit Description

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17


Product Overview

1 Product Overview

This document describes the Digital Unit (DU) for RBS 6000 systems used for
the WCDMA standard.

1.1 Purpose
The DU provides: switching, traffic management, timing, baseband processing,
and radio interfacing.

1.2 Variants
The DU variants are the following:

• DUW 10 01 (Version 2)

• DUW 20 01 (Version 1 and Version 2)

• DUW 30 01 (Version 2)

1.3 Overview
This section provides an overview of the DU, as shown in Figure 1 .

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17 1


Digital Unit Description

DUW
DUW

PW R

-48V
GPS

GPS
EC
EC
AUX

LMT A AUX
LMT A
LMT B

LMT B
TN A

TN A
ET A
ET A

ET B
ET B

I
O
F
ID L

IDL
TN B
TN B
RIA

A
R IB

B
R IC

C
RID

D
E
R IE

F
R IF

Version 1 Version 2
Ge0971A

Figure 1 Overview DUW Version 1 and Version 2

Information about DU placement can be found in RBS Description.

2 21/1551-LZA 701 6001-V2 Uen H | 2011-01-17


Function Description

2 Function Description

More information can be found in RBS Configurations.

The DU has the following functions:

• Timing function

• Loadable software

• Downlink baseband processing

• Uplink baseband processing

• ATM traffic management

• IP traffic management

• Radio interface

• Transmission handling

For the block diagram of the DU, see Figure 2 .

DU

Processing

Transmission Radio
Baseband interface

Timing

Ge0376A

Figure 2 DU Block Diagram

2.1 Maintenance Button


The maintenance button is located next to the left of the symbol. It is used
for resetting the DU. When the maintenance button is pressed for 7 seconds or
more, the DU restarts in state OFF or ON, depending on the initial state.

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17 3


Digital Unit Description

4 21/1551-LZA 701 6001-V2 Uen H | 2011-01-17


Technical Data

3 Technical Data

Technical data for the DU is listed in Table 1 .

Table 1 Technical Data


Technical Power Dimensions Capacity data
Data dissipation,
maximum
Height Width Depth Weight Maximum DCH capacity
(measured in channel
elements)
DUW 10 01 250 W 350 mm 62 mm 280 mm < 4.5 kg 128 DL
128 UL
DUW 20 01 250 W 350 mm 62 mm 280 mm < 4.5 kg 384 DL
384 UL
DUW 30 01 250 W 350 mm 62 mm 280 mm < 4.5 kg 768 DL
512 UL

A DUW contains both TX and RX modules. All three variants of the DUW have
the same capabilities, size, modularity, and interfaces. The only difference
is in the baseband capacity.

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17 5


Digital Unit Description

6 21/1551-LZA 701 6001-V2 Uen H | 2011-01-17


DU Interfaces

4 DU Interfaces

The signalling and power interfaces for the DU are listed in Table 2.

Table 2 DU Interfaces
Marking Connector Description Optical
Indicator
(1)
PWR ET20 A -48 V DC No
(2)
-48 V Power
GPS RJ-45 GPS No
External interface
(2)
EC RJ-45 EC bus Yes
Internal interface
AUX RJ-45 Auxiliary Bus No
Internal interface
LMT A RJ-45 Console No
Internal interface
LMT B RJ-45 Site LAN Yes
External interface
TN A RJ-45 Transmission, Ethernet Yes
External interface,
electrical
ET A RJ-45 Transmission, Yes
2xE1/T1/J1
External interface
ET B RJ-45 Transmission, Yes
2xE1/T1/J1
External interface
(1)
F - Fault Yes

(2) Optical indicator, red

21/1551-LZA 701 6001-V2 Uen H | 2011-01-17 7


Digital Unit Description

Marking Connector Description Optical


Indicator
(1)
O - Operation Yes

(2) Optical indicator, green


(1)
I - Maintenance Yes
(2)
Optical indicator,
(1)
yellow
(2)
Optical indicator, blue
(2)
Maintenance button No
For information about the
maintenance button, see
Section 2.1 on page 3.
IDL HSIO Inter-DU link No
Internal interface, DU to
DU
TN B SFP Transmission, Yes
Ethernet/ATM
Transmission, STM-1
External interface,
optical
(1)
RI A - RI F 6 x SFP Radio Interface x 6 Yes
(2)
A-F Internal interface
between DU and RU,
electrical
External interface
between DU and RRU,
optical
(1) DUW Version 1
(2) DUW Version 2

More information about optical indicators can be found in Interpreting Optical


Indicators.

8 21/1551-LZA 701 6001-V2 Uen H | 2011-01-17