You are on page 1of 10

AIR

BREATHER
FILTERS

The comprehensive series of breather filters makes it possible Temperature


to meet all market demands. Metal and plastic styles suitable • from -13°F to +230°F
for use on mobile equipment are available.
The function of breather filters is to collect environmental Compatibility
• NBR seals and Cork Gasket, compatible with:
contamination.
Mineral oils to ISO 2943 - aqueous emulsions
The correct use of breather filters ensures longer life Synthetic fluids, glycol water.
of components installed in the hydraulic circuit. • FPM seals, compatible with:
The use of breather filters calls for the simultaneous Synthetic fluids type HS-HFDR-HFDS-HFDU.
installation of plugs for filling and topping up fluids; it is
recommended to use plugs complete with strainer for correct
prefiltration of the fluid. If the filler plug is equipped with a filter,
the filtration degree must be the same as that of the breather
filter.

30
Metal breather filter

Series TA 46

Ordering information

TA46G-N...P01 Breather filter 1 2 3

With filter TA46


Example: TA46 G 03 P01

1 - Connection to reservoir 3 - Options

G G 1/4” P01 MP Standard


N 1/4” NPT

2 - Filter element

03 3 µm

10 10 µm

MP Filtri reserves the right to make changes to the information described herein at any time it
deems fit in relation to technical or commercial requirements. Copyright. All rights reserved.
Flow rate with Δp: 0.30 psi
Filtration cfm
3 µm 6
10 µm 7

Weight
TA 46: 0.24 lbs
1

2
Dimensions
3
Threaded connection

Ø 1.83”
1.6”

TA46 G - N (Materials)
1 - Cover: Chrome plated steel
2 - Breather filter: Resin impregnated cellulose
Polyurethane or Stainless steel
0.5”

A/F 16 mm 3 - Flange: Galvanized Steel


Connection A 4 - Threaded connection: Phosphated Steel
G G 1/4”
A
N 1/4” NPT 31
Metal breather caps

Series TA 80
TA80G......P01 Ordering information
With filter
1 2 3 4 5
Breather filter
TA80
Example: TA80 G 03 A 1 P01

1 - Connection to reservoir 5 - Options

G G 3/4” P01 MP Standard

N 3/4” NPT

2 - Filter element

03 3 µm
TA80G03.9P01
With anti-slash feature 10 10 µm

3 - Seal

0 Without

A NBR (pressurized only)


6
4 - Valves

0 Without

1 4.5 psi pressurization valve

2 10 psi pressurization valve


TA80G...A...P01 9 Anti-slosh feature (only with filter element 3 µm)
With filter and
MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
pressurization valve in relation to technical or commercial requirements. Copyright. All rights reserved.

TA80
Flow rate with Δp: 0.30 psi
Filtration cfm
3 µm 16 1
10 µm 19
2
Weight
TA 80: 0.77 lbs 3

Dimensions 5

Threaded connection

Ø 3.15”
TA80 G (Materials)
1 - Cover: Chrome plated steel
2 - Breather filter: Resin impregnated cellulose
Polyurethane
2.18”

3 - Pressurization valve: Nylon


Galvanized Steel
NBR
Connection A
A/F 35 mm 4 - Flange: Galvanized Steel
G G 3/4”
0.63”

A 5 - Threaded connection: Galvanized Steel


N 3/4” NPT
32 6 - Anti-slosh feature: Galvanized Steel
Nylon breather caps

Series TAP 90
Ordering information TAP 90 G
With filter
Air breathers 1 2 3 4 5 6
1
TAP90
Example: TAP90 G 03 0 1 L P01
2
1 - Connection to reservoir 4 - Valves

G M52x2 0 Without
3
H G 1 1/2” 1 4.5 psi pressurization valve

L G 1 1/4” 2 10 psi pressurization valve

M 3/4”NPT 5 - Variations TAP90 (Materials)

N 1”NPT
1 - Cover/ringnut: Nylon
0 Standard
2 - Breather filter: Resin impregnated cellulose or
Q G 3/4” A With Dipstick Polyurethane
2 - Filter element 3 - Seal: NBR
L With Padlock Hasp
03 3 µm
F With Dipstick and Padlock Hasp Flow rate with Δp: 0.30 psi
10 10 µm
6 - Options Filtration cfm
3 - Seal
3 µm 16
P01 MP Standard
0 Without 10 µm 19
A NBR
Weight
MP Filtri reserves the right to make changes to the information described herein at any time it deems fit TAP 90: 0.29 lbs
in relation to technical or commercial requirements. Copyright. All rights reserved.

TAP G
With Pressurization

Dimensions
TAP 90 for connection on weld flange

Ø 3.6”

2.5”

TAP G
With Dipstick
1.7”
0.2”

A
0.47”

A B
0.08” X 15°

B
G M52x2 Ø 2.07”
A
0.33”

H G 1 1/2” Ø 1.91”
0.6”

1”

L G 1 1/4” Ø 1.65”
M 3/4” NPT -
N 1” NPT -
Q G 3/4” -
33
Nylon breather caps

SAP
Series
054 - 075
SAP 054 - 075

Ordering information

1 2 3 4 5
Breather caps
SAP
Example: SAP 075 G4 L10 A P01
1 3
1
Filter element
Example: A7 L10
3
1 - Size 3 - Filter element
Filter Filter element
L03 Resin impregnated cellulose 3 µm
054 A4
2 L10 Resin impregnated cellulose 10 µm
075 A7
4 - Seal
2 - Connection to reservoir
SAP 054 - 075 (Materials) A NBR
SAP 054 SAP 075
1 - Cover: Nylon
G 3/8” G 1/2” 5 - Opzioni
G1
2 - Connection: Nylon
G2 G1/2” G 3/4” P01 MP Filtri
3 - Filter element: Resin impregnated cellulose
G3 - -
Flow rate with Δp: 0.30 psi 1/2” NPT
G4 1/2” NPT
Filtration cfm
G5 - 3/4” NPT
SAP 054
3 µm 7
MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
10 µm 9 in relation to technical or commercial requirements. Copyright. All rights reserved.

SAP 075
3 µm 12
10 µm 14

Weights
SAP 054: 0.13 lbs
SAP 075: 0.33 lbs

Connection to reservoir “ A ”
Dimensions
Type SAP G1 G2 G3 G4 G5

054 G 3/8” G 1/2” - 1/2” NPT -


075 G 1/2” G 3/4” - 1/2” NPT 3/4” NPT

Dimensions
H2

Type SAP D1 H1 H2 H3 A/F (mm)

054 G1 22
H3

054 G2 2.13” 0.53” 2” 0.31”


054 G4 27
A/F
H1

075 G1
075 G2 32
A 2.95” 0.67” 2.52” 0.35”
075 G4 27
Ø D1 075 G5 32
34
Nylon breather caps

Series
SAP
1
115
2

3
Ordering information
4 1 2 3 4 5 6 7
Breather caps
SAP115
Example: SAP115 2 A A03 A 1 B P01

SAP115 (Materials) Filter element


1 3 7
1 - Cover: Nylon A115
2 - Breather filter: Resin impregnated cellulose or Example: A115 2 A03 P01
Inorganic microfiber 1 - Length 5 - Variations
3 - Connection: Nylon 1 0 Without
4 - Seals: NBR 2 1 With anti-splash
FPM 2 - Connection 6 - Indicator
A G 1” A Without
B M33x2 B Visual indicator
C G 1 1/2”
7 - Options
3 - Filter element
P01 MP Standard
L10 Resin impreg. cellulose 10 µm

A03 Inorganic microfiber 3 µm

4 - Seals

A NBR

V FPM
Clogging indicator
Set pressure: - 0.9 psi ± 10 % MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.
Manual reset

Dimensions

Visual Flow rate with Δp: 0.30 psi


0.87”

Indicator Flitration cfm cfm


TYPE SAP 115 1 SAP 115 2

L10 77 99
G 1”
Visual A03 65 99
0.87”

Indicator
L10 82 106
G 1 1/2”
A03 70 106
6.73”

Weight
4..17”

SAP 115 1: 0.90 lbs


2.32”
2.32”

SAP 115 2: 1.16 lbs


0.71”

0.71”

Connection A A/F (mm)


A/F A/F
A A A G 1” 41
B M33x2 41
Ø 4.56” Ø 4.56”
C G 1 1/2” 55 35
Changing the filter
element in breather caps
series SAP 115

1 Thoroughly clean the filler cap and 3 Replace the filter element and replace
adjacent par ts before disassembly the cover and a hand a tighten
(DO NOT OVER TIGHTEN).
2 Unscrew and lift of f the cover.

3a

3d

3b

3c

SAP 115 spare par ts


Plug series
Item. Description Qty SAP 115

1 Complete unit 1 See order table

2 Filter Element 1 See order table


NBR VPM
3 Indicator Kit 1
02005187 02005188

3a Visual indicator 1 S62P01

3b Seal 1 O-R 3106 ID 1.05” X 103”

3c Indicator securing screw 1 01022670


3d O-R indicator 1 O-R 2112 ID 1.11” x 070”

MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.
36
Series SA
SA Ordering information
Breather series 1 2 3 4 5

SA
Example: SA 075 G4 L10 A P01
1 3
Filter element
Example: A7 L10

1 - Size 3 - Filter element


Filter Filter element Resin impregnated cellulose 10 µm
L03 (036 excluded)
036 A05
L10 Resin impregnated cellulose 10 µm
053 A5
S Without

1 075 A7
4 - Seal
115 A8 A NBR
2
145 A10 5 - Options
3
185 A11 P01 MP Standard
4

5 2 - Connection to reservoir

6 Type G1 G2 G3 G4 G5 G6

036 G 1/4” G 3/8” G 1/2” 1/4” NPT 3/8” NPT 1/2” NPT
7
053 G 1/4” G 3/8” - 1/4” NPT 3/8” NPT -

SA (Materials) 075 G 1/2” G 3/4” - 1/2” NPT 3/4” NPT -

1 - Screw: Galvanized Steel 115 G 1” - - 1” NPT - -


2 - Washer: Teflon
145 G 1 1/2” - - 1 1/2” NPT - -
3 - Cover: Steel
185 G 2 1/2” - - 2 1/2” NPT - -
4 - Filter element: Plastisol endcap
Galvanized steel mesh or MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.
Resin impregnated cellulose
5 - Ring: Galvanized Steel
6 - Seal: NBR Connection to reservoir “ A ”
7 - Connection: Anodized Aluminum or Weight
Galvanized Steel Type G1 G2 G3 G4 G5 G6 (lbs)

036 G 1/4” G 3/8” G 1/2” 1/4” NPT 3/8” NPT 1/2” NPT 0.18
Dimensions 053
075
G 1/4” G 3/8”
G 1/2” G 3/4”
-
-
1/4” NPT 3/8” NPT
1/2” NPT 3/4” NPT
-
-
0.33
0.55
115 G 1” - - 1” NPT - - 0.88
145 G 1 1/2” - - 1 1/2” NPT - - 1.30
185 G 2 1/2” - - 2 1/2” NPT - - 2.69

Dimension
H2

Type D1 H1 H2 H3 A/F (mm) Flow rate with Δp: 0.30 psi


Type 3 µm 10 µm
036 1.42” 0.51” 1.44” 0.35” 22
2.07” 22
gpm
053 2.09” 0.51” 0.28”
075 G1 0.51” 27 036 - 5
H3

075 G2 0.67” 32 053 9 9


2.95” 2.70” 0.45”
A/F 075 G4 0.59” 27 075 12 14
H1

075 G5 0.79” 32 115 28 30


A 115 4.53” 0.67” 3.15” 0.43” 38 145 64 65
Ø D1 145 5.71” 0.98” 4.53” 0.51” 55 185 81 88
38 185 7.28” 0.98” 6.46” 0.91” 80
Series SCS

Flow rate with Δp: 0.30 psi

Type Flitration gpm

P10 20
SCS 050 A03 18
A10 19

P10 20
SCS 070 A03 18
A10 19
SCS XXX C SCS XXX F
P10 50
SCS 100 A03 46
A10 47

SCS (Materials) P10 50


SCS 150 A03 46
Riser: Galvanized steel
A10 47

Dimensions

SCS XXX C SCS XXX F


Dimension SCS - CS - CG
H3
H3

Weight
Type D1 H1 H2 H3 (lbs)

CS/CG050 3.78” 0.36” 7.68” 0.79” 1.61


CS/CG070 3.78” 8.27” 10.31” 0.79” 2.09
Ø D1 Ø D1 CS100 5.08” 7.09” 9.13” 0.98” 2.87
H1

H1

A A CS150 5.08” 8.66” 10.71” 0.98” 3.53


H2
H2

CG100 5.08” 7.09” 9.13” 1.02” 2.87


CG150 5.08” 10.43” 12-48” 1.02” 3.53
0.35”
2.05”
52

Ø D2 Ø D2
Gasket Ø 42x32x2 Gasket Ø 42x32x2
Ø D3 (60Sh) (60Sh)
(for SCS 100) (for SCS 100)

Flange holes for Flange holes for SCS Riser dimensions


SCS 100 F SCS 050 F Weight
12 Type A D2 D3 (lbs)

°
60

SCS050...G1 G 3/4” 0.71” 1,26” 0.44


SCS050...G2 1” 12 UN 0.71” 1,26” 0.58
SCS100...G1 G 1 1/4” 1,26” 1.48” 0.99
Ø 0.24”

Ø 0.24”

SCS100...G2 1 1/2” 16 UN 1,26” 1.48” 1.42


Ø 1.61”
Ø 2.87”
Ø 2.05”
Ø 3.27”
39
Ordering information

Riser with
Filter 2 3 4 5 6 7
element
SCS
Example: SCS 050 F G1 A10 A P01

Riser 2 3 4 6 7
only
SCS
Example: SCS 050 F G1 A P01

1 2 5 6 7
Filter
element
Example: CS 050 A10 A P01

1 - Filter element type 5 - Filter element


Connection ISO 228
CS A03 Inorganic microfiber
for SCS......G1
CSG Connection A.S.A.
A10 Inorganic microfiber
for SCS......G2
2 - Size P10 Resin impregnated cellulose

050 6 - Seal
070 Riser assembly excluded
A NBR
100
V FPM
150 Riser assembly excluded
7 - Options
3 - Connection to reservoir
P01 MP Standard
C Weld riser

F Flange riser

4 - Threaded connection
G 3/4” for SCS 050/070
G1 G 1 1/4” for SCS 100/150

G1 with filter elements series CS

1” - 12 UN for SCS 050/070


G2
1 1/2” - 16 UN for SCS 100/150
G2 with filter elements series CSG

MP Filtri reserves the right to make changes to the information described herein at any time it deems fit
in relation to technical or commercial requirements. Copyright. All rights reserved.
37