You are on page 1of 8

PLXRMM1606A

Wall Mounted
FTN-A Series

COOLING ONLY [50Hz] 220-240V


ELEGANT,
EFFICIENT

1
Daikin’s FTN-A series An efficient and environmental friendly
wall mounted air conditioner that not only saves energy but also ozone friendly.
Stylish Flat Panel Auto Random Restart with Last-
An ideal blend of style and functionality. The State-Memory
front panel is designed for contemporary style In the event of a sudden power failure during
without compromising on function. Air intake operation, unit restarts automatically in 64
area is designed to ensure smooth air flow different recovery timing patterns (within 180
profile for better sound quality and optimized seconds to 244 seconds) and the unit will
volume. operate based on the previous setting
Sleep Mode (operating mode, temperature setting and fan
Pressing the Sleep button activates the Sleep speed). This ensures that air conditioners in
Mode. This function prevents excessive the same building resume randomly instead of
cooling for a pleasant sleep. all units resuming at the same time,
preventing power surge after a blackout.
Cooling
+
+ Power failure Power returns
+
Operation Stop Restart
Set temp. before
Sleep mode
begins to operate 30 30 60
mins mins mins

E PROM
2
Time
Sleep mode turns on

Cooling operation: Settings stored before power failure


1) After 30 minutes, room temperature is raised by 0.5˚C.
2) After 60 minutes, room temperature is raised by 0.5˚C.
3) After 120 minutes, room temperature is raised by 1˚C.

Lower Sound Level Powerful Operation


With up to five selectable fan speeds, Powerful Operation is activated by pressing
users are given more choices. By selecting the Turbo button. Once activated, the air
Quiet mode, the sound pressure level can be conditioner will run on full power with indoor
reduced down to an unobtrusive 25dBA. fan running at maximum speed for 20
minutes. This enables the set temperature
Comparison of noise level to be achieved faster. If Turbo and Sleep are
activated at the same time, the Sleep mode
20
timer will be reset, it will resume after Turbo
Rustling
of leaves 30
Pendulum of 40
function is cleared.
a wall clock Library 50 (dBA)
25dBA Normal office
for T room
FTN25AXV1

Compact & Easy-to-Use


BRC52A Handset
T set

• Prominent 40mm LCD Start 20min 30min


display.
• Real time clock display.
• Dedicated buttons for Quiet
and Turbo functions.

2
Wall Mounted (50Hz)

RN25FAXV1
FTN25/35/50/60AXV1

> Uniform air distribution


> Stylish flat-panel
> Quiet operation
> Powerful operation
> Easy maintenance
> Washable saranet filter
> Wireless handset BRC52A as standard

RN35FAXV1 RN50/60CAXV1

Specification for wall mounted - Cooling only (R410A)


Indoor model name FTN25AXV1 FTN35AXV1 FTN50AXV1 FTN60AXV1
Outdoor model name RN25FAXV1 RN35FAXV1 RN50CAXV1 RN60CAXV1
Btu/h  9000 12000 18000 22000
Nominal Cooling Capacity
W 2640 3520 5280 6450
Nominal EER W/W 3.03 3.18 3.02 3.22
Airflow (Turbo/H/M/L/Quiet) CFM 358/342/282/225/209 372/355/298/242/225 594/531/474/422/381 641/614/537/474/418
Sound pressure level (Turbo/H/M/L/Quiet) dBA 39/38/33/27/25 41/40/35/29/28 44/42/39/36/35 48/46/43/40/37
Indoor

Dimensions (HxWxD) mm 288x859x209 310x1124x237


Net weight kg 9 14
Indoor air quality - Saranet Filter
Power supply V/ph/Hz 220-240/1/50 (Power from indoor)
Sound pressure level dBA 46 47 52 52
Dimensions (HxWxD) mm 485x566x256 550x658x273 651x855x328
Outdoor

Net weight kg 21 26 47 50
Pipe connection - Liquid mm 6.35
Pipe connection - Gas mm 9.52 12.70 15.88
Maximum piping length m 20 20 30
Maximum piping elevation m 12 15 15

1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB.
2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.

3
Function Dictionary

Comfortable Airflow Worry Free

Wide-Angle Louvers Auto Random Restart with


The smoothly curved Wide-Angle Louvers provide wide Last-State-Memory
airflow coverage for effective operation no matter where In the event of a sudden power failure during operation,
the indoor unit is placed in a room. unit restarts automatically in 64 different recovery
timing patterns (within 180 seconds to 244 seconds)
Vertical Auto-Swing (up and down) and the unit will operate based on the previous setting
This function automatically moves the flaps up and down (operating mode, temperature setting and fan speed).
to distribute air across a room.
Self-Diagnosis
BLINK Malfunctioning of air conditioner unit by blinking of LED
Lifestyle Convenience lights for fast and easy maintenance.

New Powerful Operation


New Powerful Operation boosts airflow to maximum Cleanliness
volume for a 20-minute period. After this, the unit
automatically returns to its previous settings. Washable Saranet Filter
Indoor Unit On/Off Switch Removal of airborne dust particles through saranet filter
The unit can be conveniently started manually in the ensures cleaner air supply.
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged. Wipe-Clean Flat Panel
The flat panel models can be cleaned with only the
single pass of a cloth across their smooth surface. The
flat panel can also be easily removed for more thorough
Comfort Control
cleaning.
Indoor Unit Quiet Operation
Indoor unit operating sound levels are decreased
by 3dB(A) from the Low setting fan speed using the
wireless remote controller.
Programme Dry Function
This function automatically reduces the level of
humidity.

Auto Fan Speed


The microprocessor automatically controls fan speed
to adjust the room temperature to the set temperature.

Timers

24-Hour On/Off Timer


This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.

Sleep Mode
Pressing the Sleep button activates the Sleep Mode.
After 30 minutes, room temperature is raised by 0.5°C.
After 60 minutes, room temperature is raised by 0.5°C.
After 120 minutes, room temperature is raised by 1°C.

4
Wireless controller BRC52A

Vertical auto-swing “Glow-in-the-dark” On/Off switch


Fan speed selection: Low, Med, High, Auto
Selectable Mode: Cool, Dry, Fan
Turbo function Temperature setting: Up & down
Quiet function
Sleep mode function
On timer setting Off timer setting
Real time clock

Options - Control System

Wired controller BRC51A

Real time clock and day display

Temperature operate in ºC and ºF


Turbo function Swing function
Cool, Dry, Fan mode
Delay timer (1 or 2 hours) Quiet function
7-days programmable timer Sleep function
Low, Med, High, Auto fan speed On/Off switch

Please refer to technical manual for wiring to the wall mounted unit.

5
Notes

6
Warning ● Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm
with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and
is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify
the application of any local legislation.

● Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can
result in water or refrigerant leakage, electrical shock, fire or explosion.

● Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those
parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can
result in water or refrigerant leakage, electrical shock, fire or explosion.

● Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and
warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Caution Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need
to install the outdoor unit close to the sea shore, contact your local distributor.

Dealer
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.
http://www.daikinmalaysia.com/

Head office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan.

● Specifications, designs and other content appearing in this brochure are current as of March 2016 but subject to change without notice. © All rights reserved.
7

You might also like