You are on page 1of 8

PLXRMM1606B

Wall Mounted
FTN-A Series

COOLING ONLY [50Hz] 220-240V


ELEGANT,
EFFICIENT

1
Daikin’s FTN-A series
wall mounted air conditioner that not only saves energy but also ozone friendly.
Stylish Flat Panel Auto Random Restart with Last-
An ideal blend of style and functionality. The State-Memory
front panel is designed for contemporary style In the event of a sudden power failure during
without compromising on function. Air intake operation, unit restarts automatically in 64
different recovery timing patterns (within 180
seconds to 244 seconds) and the unit will
volume. operate based on the previous setting
Sleep Mode (operating mode, temperature setting and fan
Pressing the Sleep button activates the Sleep speed). This ensures that air conditioners in
Mode. This function prevents excessive the same building resume randomly instead of
cooling for a pleasant sleep. all units resuming at the same time,
preventing power surge after a blackout.
Cooling
+
+ Power failure Power returns
+
Operation Stop Restart
Set temp. before
Sleep mode
begins to operate 30 30 60
mins mins mins
2
Time E PROM
Sleep mode turns on

Cooling operation: Settings stored before power failure


1) After 30 minutes, room temperature is raised by 0.5˚C.
2) After 60 minutes, room temperature is raised by 0.5˚C.
3) After 120 minutes, room temperature is raised by 1˚C.

Lower Sound Level Powerful Operation


Powerful Operation is activated by pressing
users are given more choices. By selecting the Turbo button. Once activated, the air
Quiet mode, the sound pressure level can be conditioner will run on full power with indoor
reduced down to an unobtrusive 25dBA. fan running at maximum speed for 20
minutes. This enables the set temperature
Comparison of noise level to be achieved faster. If Turbo and Sleep are
activated at the same time, the Sleep mode
20
timer will be reset, it will resume after Turbo
Rustling
of leaves 30
Pendulum of 40
function is cleared.
a wall clock Library 50 (dBA)
25dBA Normal office
for T room
FTN25AXV1

Compact & Easy-to-Use


BRC52A Handset
T set

• Prominent 40mm LCD Start 20min 30min


display.
• Real time clock display.
• Dedicated buttons for Quiet
and Turbo functions.

2
Wall Mounted (50Hz)

FTN25/35/50/60AXV1 RN25FAXV1

FTN80AXV1
RN35FAXV1 RN50/60CAXV1

> Uniform air distribution

> Quiet operation


> Powerful operation
> Easy maintenance

> Wireless handset BRC52A62 as standard RN71CAXV1

Indoor model name FTN25AXV1 FTN35AXV1 FTN50AXV1 FTN60AXV1 FTN80AXV1


Outdoor model name RN25FAXV1 RN35FAXV1 RN50CAXV1 RN60CAXV1 RN71CAXV1
Btu/h 9000 12000 18000 22000 30000
Nominal Cooling Capacity
W 2640 3520 5280 6450 8900
Nominal EER W/W 3.03 3.18 3.02 3.22 3.03
CFM 358/342/282/225/209 372/355/298/242/225 594/531/474/422/381 641/614/537/474/418 950/931/760/661/569
Sound pressure level (Turbo/H/M/L/Quiet) dBA 39/37/33/27/25 40/39/35/29/28 44/42/39/36/35 48/46/43/39/37 52/51/46/42/39
Indoor

Dimensions (HxWxD) mm 288x859x209 310x1124x237 310 X 1289 X 240


Net weight kg 9 14 16
Indoor air quality - Saranet Filter
Power supply V/ph/Hz 220-240/1/50 (Power from indoor)
Sound pressure level dBA 46 47 52 52 56
Dimensions (HxWxD) mm 485x566x256 550x658x273 651x855x328 753x855x328
Outdoor

Net weight kg 21 26 47 47 57
Pipe connection - Liquid mm 6.35 9.52
Pipe connection - Gas mm 9.52 12.70 15.88
Maximum piping length m 20 25 30 45
Maximum piping elevation m 12 15 15 25

1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB.
2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.

3
Function Dictionary

C o m f o r ta b l e A i r f l o w Worry Free

Wide-Angle Louvers Auto Random Restart with


The smoothly curved Wide-Angle Louvers provide wide Last-State-Memory
In the event of a sudden power failure during operation,
the indoor unit is placed in a room. unit restarts automatically in 64 different recovery
timing patterns (within 180 seconds to 244 seconds)
Vertical Auto-Swing (up and down) and the unit will operate based on the previous setting
(operating mode, temperature setting and fan speed).
to distribute air across a room.
Self-Diagnosis
BLINK Malfunctioning of air conditioner unit by blinking of LED
Lifestyle Convenience lights for fast and easy maintenance.

New Powerful Operation


Cleanliness
volume for a 20-minute period. After this, the unit
automatically returns to its previous settings. Washable Saranet Filter
Indoor Unit On/Off Switch
The unit can be conveniently started manually in the ensures cleaner air supply.
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged. Wipe-Clean Flat Panel

single pass of a cloth across their smooth surface. The


C o m f o r t C o n tr o l
cleaning.
Indoor Unit Quiet Operation
Indoor unit operating sound levels are decreased
by 3dB(A) from the Low setting fan speed using the
wireless remote controller.
Programme Dry Function
This function automatically reduces the level of
humidity.
Auto Fan Speed
The microprocessor automatically controls fan speed
to adjust the room temperature to the set temperature.

Timers

24-Hour On/Off Timer


This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.

Sleep Mode
Pressing the Sleep button activates the Sleep Mode.
After 30 minutes, room temperature is raised by 0.5°C.
After 60 minutes, room temperature is raised by 0.5°C.
After 120 minutes, room temperature is raised by 1°C.

4
Wireless controller BRC52A62

Vertical auto-swing “Glow-in-the-dark” On/Off switch


Fan speed selection: Low, Med, High, Auto
Selectable Mode: Cool, Dry, Fan
Turbo function Temperature setting: Up & down
Quiet function
Sleep mode function
On timer setting Off timer setting
Real time clock

Options - Control System

Wired controller BRC51A62

Real time clock and day display

Temperature operate in ºC and ºF


Turbo function Swing function
Cool, Dry, Fan mode
Delay timer (1 or 2 hours) Quiet function
7-days programmable timer Sleep function
Low, Med, High, Auto fan speed On/Off switch

Please refer to technical manual for wiring to the wall mounted unit.

5
Notes

6
Warning ●
with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and
is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify
the application of any local legislation.


parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can

● Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and
warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Caution Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need
to install the outdoor unit close to the sea shore, contact your local distributor.

Dealer
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.
http://www.daikinmalaysia.com/

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,


Kita-ku, Osaka, 530-8323 Japan.

October 2017 © All rights reserved.

You might also like