Medium Voltage Product

TPU 7x.xx
Indoor current transformers

Highest voltage for equipment [kV] 36 ; 38.5 ; 40,5


Power frequency test voltage, 1 min. [kV] 70 ; 80 ; 90
Lighting impulse test voltage [kV] 170 ; 180 ; 200
R a t e d c u r re n t [A] 10 - 2500
Rated short-time thermal current [kA] up to 100
Burdens, classes [VA/cl] 5-30 / 0.2-1 / 5P ; 10P
(acc. to other param. - Ith)
Reconnectible prim. or sec.
(primary till 600-1200 A)

Description
The transformers are cast in epoxy resin and designed for Rated primary currents are 10;15;20;25;30;40;50;60;75;100;
insulation voltages from 36 kV to 40.5 kV. 150;200;300;400;500;600;750;1000;1250;1500; 2000;2500 A.
The transformers are designed as single-or-multiple turn Other primary currents can be agreed with the manufacturer.
transformers, with one transformer ratio, or with the possibility Rated secondary currents...5 A; 1 A (possibility to combine
to be switched over on the secondary or primary side. different values in one transformer)
The number of secondary windings are from 1 to 8 (usually Rated frequency ... 50 Hz; 60 Hz
2 secondary windings), depending on the combination of The transformers are designed and manufactured in conform-
parameters (such as the accuracy class, short-circuit current, ity with the following standards and recommendations:
overcurrent factor…). IEC, ANSI, VDE, BS, GOST and CSN.
The secondary windings are used for measurement or protec- Cantilever strength: 5 kN
tion purposes, or for special use (testing winding, „X“ class Permissable torques for screw connections
windings ..). One terminal of each secondary winding used M5 max /Nm/ …3,5 min /Nm/…2,8
and one terminal of short-circuited and not used winding have M8 max /Nm/ …20 min /Nm/…16
to be earthed during the transformer operation. M12 max /Nm/ …70 min /Nm/…56
The secondary windings are lead out into a casted secondary
terminal board. The transformer can be mounted in any posi-
tion. The transformer are fixed by four screws, the M8 bolted
earthing clamp finds itself on the transformer base plate.
Dimensions

TPU 70.51 WEIGHT: appr. 49kg TPU 70.52 WEIGHT: appr. 49kg
CREP. DISTANCE: 400mm CREP. DISTANCE: 409mm
TPU 73.51 TPU 73.52

2
2

390
390

14
14

-P
-P

g1
g1

6
6

4
4

40

22
40

22

187 155 187 155


32 120 32
208 208
22,5
32 120 32
M12
24

24
40 M 22,5
12
80 80
310

40
M8 310 M8

M
8
190
190

220
190
190

220

L
L

P1 P2 P1 C1C2 P2

140 140
12

12
285
285
295 15
295 15
365
365

L=96mm for 6 or 12 clamps L=96mm for 6 or 12 clamps


L=122mm for 16 clamps L=122mm for 16 clamps

Drawing n. Polarity Drawing n. Polarity


44615730 P1 to secondary term. 44615750 P1 to secondary term.
44615740 P2 to secondary term. 44615760 P2 to secondary term.

TPU 70.53 WEIGHT: appr. 49kg TPU 70.54 WEIGHT: appr. 49kg
CREP. DISTANCE: 397mm CREP. DISTANCE: 409mm
TPU 73.53 TPU 73.54
2
2

450
450

390
390

14
14

-P
-P

g1
g1

6
6

4
4

40
40

22
22

187 155
187 155 32 120 32
208 208
32 120 32 22,5
M1
2
24
24

M
60

12 22,5

67 67 310
40

M8 310 M8
M
8
190
190

220

190
190

220
85

85
L

P1 P2 P1 C1C2 P2

140 140
12

12

285
285
295 15
295 15
365
365

L=96mm for 6 or 12 clamps L=96mm for 6 or 12 clamps


L=122mm for 16 clamps L=122mm for 16 clamps

Drawing n. Polarity Drawing n. Polarity


44615650 P1 to secondary term. 44615710 P1 to secondary term.
44615660 P2 to secondary term. 44615720 P2 to secondary term.

2
TPU 74.51 WEIGHT: appr. 49kg TPU 74.53 WEIGHT: appr. 49kg
CREP. DISTANCE: 386mm CREP. DISTANCE: 386mm
TPU 75.51 TPU 75.53
TPU 76.51 TPU 76.53

450
390

390
14
-P
g1

14
6

-P
g1
6
4

4
40

22

40

22
187 155
32 120 32
M
12 187 155
208
32 120 32
208
M

40

80
12

40
80
310 80 80
M8
80 80
M8 310
190
190

220
L

P1 P2

190
190

110

220
L
P1 P2

140
12

285 140

12
295 15 285

365 295 15

365

L=96mm for 6 or 12 clamps L=96mm for 6 or 12 clamps


L=122mm for 16 clamps L=122mm for 16 clamps

Drawing n. Polarity Drawing n. Polarity


44615690 P1 to secondary term. 44615670 P1 to secondary term.
44615700 P2 to secondary term. 44615680 P2 to secondary term.

TPU 70.63 WEIGHT: appr. 78kg TPU 70.64 WEIGHT: appr. 78kg
CREP. DISTANCE: 463mm CREP. DISTANCE: 456mm
TPU 73.63 TPU 73.64
2

2
450

450
390

390
14

14
-P

-
g1

Pg
6

61
40

22

40

22

225 200 32 120 32


225 200
32 120 32
246 223 M
12
4

246 223
4

22,5
60

24
24
M1

22,5
67 67
2

M8
M8
40
M8
225

113
160
225

260
L

225

113

160

225
260
L

P1 P2
P1 P2

12
185 185 12

375 375
385 15
385 15
446
446

L=96mm for 6 or 12 clamps


L=96mm for 6 or 12 clamps
L=122mm for 16 clamps
L=122mm for 16 clamps

Drawing n. Polarity Drawing n. Polarity


44615570 P1 to secondary term. 44615610 P1 to secondary term.
44615580 P2 to secondary term. 44615620 P2 to secondary term.

3
Dimensions

TPU 70.66 WEIGHT: appr. 78kg TPU 74.63 WEIGHT: appr. 78kg
CREP. DISTANCE: 413mm CREP. DISTANCE: 463mm
TPU 73.66 TPU 75.63
TPU 76.63

2
2

450

450
390

390
14

14
-P

-P
g1

g1
6

6
40

40
22

22
225 200 225 200
32 220 32
32 120 32
246 223 M
246 223
4

12 M1

4
2

60

40

80
67 67

M8 M8 80 80
225

113
160
225

260

225

113
160
225
260
L

L
P1 P2 P1 P2

12 12
185 375

375 385 15
446
385 15

446

L=96mm for 6 or 12 clamps L=96mm for 6 or 12 clamps


L=122mm for 16 clamps L=122mm for 16 clamps

Drawing n. Polarity Drawing n. Polarity


44615630 P1 to secondary term. 44615590 P1 to secondary term.
44615640 P2 to secondary term. 44615600 P2 to secondary term.

4
Code designation - TPU current transformers

TPU x x . x x
voltage current dimension primary terminals

7..up to 36 (40,5) kV 0… 5 A - 600 A multiturn 5..short, narrow 220mm 1..no pr.rec., no ribs /40x80mm, 80x80mm/
3…to 1250 A singleturn 6..long, wide 260mm 2..prim. rec., no ribs /40x80mm,/
4…to 1500 A singleturn 7..short, narrow 220mm, 3..no pr.rec., with ribs /40x80mm, 60x67mm, 80x80mm/
5…to 2000 A singleturn base plate 260mm 4..prim. rec., with ribs /40x80mm/
6…to 2500 A singleturn 5..no pr.rec., with ribs /80x80mm-6xM12/
6..no pr.rec., with ribs /60x67mm/, distance220mm

Marking of current transformer outlets

a) Single-core design | b) Double-core design | c) Three-core design | d) Single-core design, reconnectable on the secondary side | e) Double-core
design, reconnectable on the secondary side | f) Double-core design, reconnectable on the primary side

Secondary terminal box

5
Standartized transformers

Type Ithn Ratio Burden class FS/ALF Type Ithn Ratio Burden class FS/ALF
[ kA ] [A] [ VA ] [ kA ] [A] [ VA ]
TPU 70.51 6,3/16 10//5 30 10P 5 TPU 70.51 31,5/80 60//5 30 5P 5
TPU 70.51 6,3/16 10//5 15 0,5 FS5 TPU 70.51 31,5/80 60//5/5 15/15 0,5/10P FS5/10
TPU 70.51 6,3/16 10//5/5 10/15 0,5/10P FS5/5 TPU 70.51 50/125 60//5 30 10P 5
TPU 70.51 6,3/16 10//5/5 15/15 3/10P 5/5 TPU 70.51 50/125 60//5/5 10/15 0,5/10P FS5/5
TPU 70.51 10/25 10//5 15 10P 5 TPU 70.51 50/125 60//5/5 15/15 3/10P 10/5
TPU 70.51 10/25 10//5/5 5/10 0,5/10P FS5/5 TPU 70.51 31,5/80 75//5 30 5P 10
TPU 70.51 10/25 10//5/5 15/10 3/10P 5/5 TPU 70.51 31,5/80 75//5/5 15/15 0,5/5P FS5/10
TPU 70.51 10/25 15//5 15 10P 5 TPU 70.51 50/125 75/5 30 5P 5
TPU 70.51 10/25 15//5/5 10/15 0,5/10P FS5/5 TPU 70.51 50/125 75/5/5 10/15 0,5/10P FS5/5
TPU 70.51 10/25 15//5/5 15/15 3/10P 5/5 TPU 70.51 31,5/80 100//5 30 5P 5
TPU 70.51 16/40 15//5 15 10P 5 TPU 70.51 31,5/80 100//5/5 15/15 0,5/5P FS5/10
TPU 70.51 16/40 15//5/5 5/10 0,5/10P FS5/5 TPU 70.51 50/125 100//5 20 5P 10
TPU 70.51 16/40 15//5/5 15/10 3/10P 5/5 TPU 70.51 50/125 100//5/5 10/15 0,5/5P FS5/10
TPU 70.51 16/40 20//5 30 10P 5 TPU 70.51 31,5/80 150//5 30 5P 10
TPU 70.51 16/40 20//5/5 10/15 0,5/10P FS5/5 TPU 70.51 31,5/80 150//5/5 15/15 0,5/5P FS10/10
TPU 70.51 16/40 20//5/5 15/15 3/10P 5/5 TPU 70.51 50/125 150//5 30 5P 5
TPU 70.51 31,5/80 20//5 15 10P 5 TPU 70.51 50/125 150//5/5 10/15 0,5/5P FS10/10
TPU 70.51 31,5/80 20//5/5 5/10 0,5/10P FS5/5 TPU 70.51 50/125 200//5 30 5P 10
TPU 70.51 31,5/80 20//5/5 15/10 3/10P 5/5 TPU 70.51 50/125 200//5/5 15/15 0,5/5P FS10/10
TPU 70.51 20/50 25//5 30 10P 5 TPU 70.51 50/125 250//5 30 5P 10
TPU 70.51 20/50 25//5/5 10/15 0,5/10P FS5/5 TPU 70.51 50/125 250//5/5 15/15 0,5/5P FS10/10
TPU 70.51 20/50 25//5/5 15/15 3/10P 5/5 TPU 70.51 50/125 300//5 30 5P 10
TPU 70.51 40/100 25//5 15 10P 5 TPU 70.51 50/125 300//5/5 15/15 0,5/5P FS10/10
TPU 70.51 40/100 25//5/5 5/10 0,5/10P FS5/5 TPU 70.51 50/125 400//5 30 5P 10
TPU 70.51 40/100 25//5/5 15/10 3/10P 5/5 TPU 70.51 50/125 400//5/5 15/15 0,5/5P FS10/10
TPU 70.51 25/63 30//5 30 10P 5 TPU 70.51 50/125 500//5 30 5P 15
TPU 70.51 25/63 30//5/5 10/15 0,5/10P FS5/5 TPU 70.51 50/125 500//5/5 15/15 0,5/5P FS10/10
TPU 70.51 25/63 30//5/5 15/15 3/10P 5/5 TPU 70.51 50/125 600//5 30 5P 15
TPU 70.51 31,5/80 30//5 30 10P 5 TPU 70.51 50/125 600//5/5 15/30 0,5/5P FS10/10
TPU 70.51 31,5/80 30//5/5 15/15 3/10P 5/5 TPU 73.51 63/160 750//5 30 5P 10
TPU 70.51 40/100 30//5 15 10P 5 TPU 73.51 63/160 750//5/5 15/15 0,5/5P FS10/10
TPU 70.51 40/100 30//5/5 5/10 0,5/10P FS5/5 TPU 73.51 80/200 1000//5 30 5P 15
TPU 70.51 40/100 30//5/5 15/10 3/10P 5/5 TPU 73.51 80/200 1000//5/5 30/15 0,5/5P FS5/10
TPU 70.51 31,5/80 40//5 30 5P 5 TPU 73.51 80/200 1250//5 30 5P 15
TPU 70.51 31,5/80 40//5/5 15/15 0,5/10P FS5/5 TPU 73.51 80/200 1250//5/5 30/30 0,5/5P FS10/10
TPU 70.51 50/125 40//5 15 10P 5/5 TPU 74.51 100/250 1500//5 30 5P 15
TPU 70.51 50/125 40//5/5 5/10 0,5/10P FS5/5 TPU 74.51 100/250 1500//5/5 30/30 0,5/5P FS10/10
TPU 70.51 50/125 40//5/5 15/10 3/10P 5/5 TPU 75.51 100/250 2000//5 60 5P 10
TPU 70.51 31,5/80 50//5 30 5P 5 TPU 75.51 100/250 2000//5/5 30/30 0,5/5P FS10/10
TPU 70.51 31,5/80 50//5/5 15/15 0,5/10P FS5/10 TPU 76.51 100/250 2500//5 30 5P 15
TPU 70.51 50/125 50//5 30 10P 5 TPU 76.51 100/250 2500//5/5 30/60 0,5/5P FS10/10
TPU 70.51 50/125 50//5/5 10/15 0,5/10P FS5/5
TPU 70.51 50/125 50//5/5 15/15 3/10P 5/5 other on request

6
Note:

7
1VLC000501 - Rev.3, en 2010. 12.10.
ABB s.r.o. The data and ilustrations in this catalogue are not
binding. We reserve the right to make changes of the
Videnska 117
content, in the course of technical development of the
619 00 Brno, Czech Republic product.
E-mail: info.ejf@cz.abb.com
Tel.: +420 547 152 602
+420 547 152 614
Fax: +420 547 152 626

http://www.abb.com