You are on page 1of 6

Inductive proximity sensors

For specific applications


Analogue output models
References :
pages 1/121 to 1/124 Applications, operating principle, output curves, schemes
Characteristics :
pages 1/121 to 1/124

Applications
1 Example : These analogue output proximity sensors are solid state sensors, designed for monitoring displacements.
sorting parts They have a wide range of applications, but are particularly suited for :
- deformation or displacement monitoring,
- vibration amplitude and frequency monitoring,
- control of dimensional tolerances,
- position control,
- monitoring of concentricity and eccentricity.

Operating principle

The operating principle of the sensor is that of a damped oscillator. The degree of damping will depend on the distance of an object from the sensing face. The
sensor will sense the distance and produce an output current with a value directly proportional to this distance.
1.3 Output curves 4...20 mA, 2-wire connection (cylindrical models)
XS1-M12AB120 XS1-M18AB120 XS1-M30AB120
Sn = 0.2…2 mm Ø 12 mm Sn = 0.5…5 mm Ø 18 mm Sn = 1…10 mm Ø 30 mm
22 22 22
Output current Is (mA)

Output current Is (mA)


Output current Is (mA)

20 20 20
18 18 18
16 16 16
14 14 14
12 2 2
10 10 10
8 8 8
6 6 6
4 4 4
2 2 2
0 0 0
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 0 1 2 3 4 5 6 7 8 9 10
Sensing distance/object (mm) Sensing distance/object (mm) Sensing distance/object (mm)
XS4-P12AB120 XS4-P18AB120 XS4-P30AB120
Sn = 0.4…4 mm Ø 12 mm Sn = 0.8…8 mm Ø 18 mm Sn = 1.5…15 mm Ø 30 mm
22 22 22
Output current Is (mA)
Output current Is (mA)

Output current Is (mA)

20 20 20
18 18 18
16 16 16
14 14 14
12 12 2
10 10 10
8 8 8
6 6 6
4 4 4
2 2 2
0 0 0
0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 3,6 4 0 0,8 1,6 2,4 3,2 4 4,8 5,6 6,4 7,2 8 0 1,5 3 4,5 6 7,5 9 10,5 12 13,5 15
Sensing distance/object (mm) Sensing distance/object (mm) Sensing distance/object (mm)

Output curves 0...10 mA, 3-wire connection (cylindrical models)


XS4-P12AB110 XS4-P18AB110 XS4-P30AB110
Sn = 0.4…4 mm Ø12 mm Sn = 0.8…8 mm Ø18 mm Sn = 1.5…15 mm Ø 30 mm
11 11 11
Output current Is (mA)

Output current Is (mA)

Output current Is (mA)

10 10 10
9 9 9
8 8 8
7 7 7
6 6 6
5 5 5
4 4 4
3 3 3
2 2 2
1 1 1
0 0 0
0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 3,6 4 0 0,8 1,6 2,4 3,2 4 4,8 5,6 6,4 7,2 8 0 1,5 3 4,5 6 7,5 9 10,5 12 13,5 15
Sensing distance/object (mm) Sensing distance/object (mm) Sensing distance/object (mm)

Wiring schemes
2-wire connection 3-wire connection
BN/1 BN/1
+ +
mA mA BK/4
BK/4 Is Output voltage
Output current
R R U=R.Is
BU/3 BU/3
– –
Is
Output current Value of R (R = load impedance) Output current Value of R (R = load impedance)
24 V 4…14 mA ≤ 640 Ω 24 V 0…10 mA ≤ 1800 Ω
4…20 mA ≤ 450 Ω 0…16 mA ≤ 1125 Ω
48 V 4…14 mA ≤ 2350 Ω 48 V 0…10 mA ≤ 4200 Ω
Ensure a minimum of 15 V between the + (1) and - (3) terminals of the sensor Ensure a minimum of 5 V between the + and sensor output (terminal 4)

1/120 Te
Inductive proximity sensors
For specific applications
Analogue output models
Accessories :
page 3/0 3 Cylindrical type, M12 x 1 threaded, metal or plastic case
Output curves :
page 1/120
Schemes : References, characteristics, setting-up
page 1/120

Flush mountable in metal Non flush mountable in metal


1

b
a

Lengths (mm) :
a = Overall a = 50 a = 50 a = 50
b = Threaded section b = 42 b = 42 b = 42

Metal case Plastic case Plastic case

Nominal sensing distance (Sn) 0.2…2 mm 0.4…4 mm 0.4…4 mm


1.3
References

3-wire a Output 0…10 mA (1) – – XS4-P12AB110


4…14 mA (2)

Output 4…20 mA (2) XS1-M12AB120 XS4-P12AB120 –


0…16 mA (1)

Weight (kg) 0.075 0.065 0.065

Characteristics

Connection Pre-cabled, 3 x 0.34 mm2, length 2 m

Degree of protection IP 67

Operating zone 0.2…2 mm 0.4…4 mm 0.4…4 mm

Repeat accuracy ±1%

Linearity error ±4%

Ambient air temperature Operation : - 25…+ 70 °C

Rated supply voltage a 24 V a 24 V a 24…48 V

Voltage limits (including ripple) a 15…38 V a 15…38 V a 15…58 V

Output current drift ≤ 10 %


θ ambient : - 25…+ 70 °C

Current consumption, no-load 4 mA

Maximum frequency 1500 Hz


(1) Output current range for “3-wire” connection, see page 1/120.
(2) Output current range for “2-wire” connection, see page 1/120.

Setting-up
Minimum mounting
distances (mm)
Side by side Face to face Facing a metal object Mounted in a metal support

e e
h

XS1-M12AB120 flush mountable e≥4 e ≥ 24 e≥6 d ≥ 12, h ≥ 0


XS4-P12AB110 non flush mountable e ≥ 16 e ≥ 48 e ≥ 12 d ≥ 36, h ≥ 8
XS4-P12AB120 non flush mountable e ≥ 16 e ≥ 48 e ≥ 12 d ≥ 36, h ≥ 8
Fixing nut tightening torque : < 6 N.m (metal case), < 2 N.m (plastic case)

Other versions “Original equipment” range Ø 12 mm sensors with analogue output (XSi-Hiii62).
Please consult your local Customer support centre.

Te 1/121
Inductive proximity sensors
For specific applications
Accessories :
Analogue output models
page 3/0 Cylindrical type, M18 x 1 threaded, metal or plastic case
Output curves :
page 1/120
Schemes : References, characteristics, setting-up
page 1/120

Flush mountable in metal Non flush mountable in metal


1
b c
a

Lengths (mm) :
a = Overall a = 50 a = 40.6 a = 40.6
b = Threaded section b = 42 b = 26 b = 26
c = For non flush mounting sensors c=0 c=8 c=8
Metal case Plastic case Plastic case

Nominal sensing distance (Sn) 0.5…5 mm 0.8…8 mm 0.8…8 mm


1.3
References

3-wire a Output 0…10 mA (1) – – XS4-P18AB110


4…14 mA (2)

Output 4…20 mA (2) XS1-M18AB120 XS4-P18AB120 –


0…16 mA (1)

Weight (kg) 0.120 0.080 0.080

Characteristics

Connection Pre-cabled, 3 x 0.34 mm2, length 2 m

Degree of protection IP 67

Operating zone 0.5…5 mm 0.8…8 mm 0.8…8 mm

Repeat accuracy ±1%

Linearity error ±4%

Ambient air temperature Operation : - 25…+ 70 °C

Rated supply voltage a 24 V a 24 V a 24…48 V

Voltage limits (including ripple) a 15…38 V a 15…38 V a 15…58 V

Output current drift ≤ 10 %


θ ambient : - 25…+ 70 °C

Current consumption, no-load 4 mA

Maximum frequency 500 Hz


(1) Output current range for “3-wire” connection, see page 1/120.
(2) Output current range for “2-wire” connection, see page 1/120.

Setting-up
Minimum mounting
distances (mm)
Side by side Face to face Facing a metal object Mounted in a metal support

d
e e
h

XS1-M18AB120 flush mountable e ≥ 10 e ≥ 60 e ≥ 15 d ≥ 18, h ≥ 0


XS4-P18AB110 non flush mountable e ≥ 32 e ≥ 96 e ≥ 24 d ≥ 54, h ≥ 16
XS4-P18AB120 non flush mountable e ≥ 32 e ≥ 96 e ≥ 24 d ≥ 54, h ≥ 16
Fixing nut tightening torque : < 15 N.m (metal case), < 5 N.m (plastic case)

Other versions “Original equipment” range Ø 18 mm sensors with analogue output (XSP-Hiii62).
Please consult your local Customer support centre.

1/122 Te
Inductive proximity sensors
For specific applications
Accessories : Analogue output models
page 3/0 Cylindrical type, M30 x 1.5 threaded, metal or plastic case
Output curves :
page 1/120
Schemes : References, characteristics, setting-up
page 1/120

Flush mountable in metal Non flush mountable in metal


1
b c
a

Lengths (mm) :
a = Overall a = 50 a = 52.6 a = 52.6
b = Threaded section b = 42 b = 32 b = 32
c = For non flush mounting sensors c=0 c = 13 c = 13
Metal case Plastic case Plastic case

Nominal sensing distance (Sn) 1…10 mm 1.5…15 mm 1.5…15 mm


1.3
References

3-wire a Output 0…10 mA (1) – – XS4-P30AB110


4…14 mA (2)

Output 4…20 mA (2) XS1-M30AB120 XS4-P30AB120 –


0…16 mA (1)

Weight (kg) 0.200 0.100 0.100

Characteristics

Connection Pre-cabled, 3 x 0.34 mm2, length 2 m

Degree of protection IP 67

Operating zone 1…10 mm 1.5…15 mm 1.5…15 mm

Repeat accuracy ±1%

Linearity error ±4%

Ambient air temperature Operation : - 25…+ 70 °C

Rated supply voltage a 24 V a 24 V a 24…48 V

Voltage limits (including ripple) a 15…38 V a 15…38 V a 15…58 V

Output current drift ≤ 10 %


θ ambient : - 25…+ 70 °C

Current consumption, no-load 4 mA

Maximum frequency 300 Hz


(1) Output current range for “3-wire” connection, see page 1/120.
(2) Output current range for “2-wire” connection, see page 1/120.

Setting-up
Minimum mounting
distances (mm)
Side by side Face to face Facing a metal object Mounted in a metal support

d
e e
h

XS1-M30AB120 flush mountable e ≥ 20 e ≥ 120 e ≥ 30 d ≥ 30, h ≥ 0


XS4-P30AB110 non flush mountable e ≥ 60 e ≥ 180 e ≥ 45 d ≥ 90, h ≥ 30
XS4-P30AB120 non flush mountable e ≥ 60 e ≥ 180 e ≥ 45 d ≥ 90, h ≥ 30
Fixing nut tightening torque : < 40 N.m (metal case), < 20 N.m (plastic case)

Te 1/123
Inductive proximity sensors
For specific applications
Analogue output models
Accessories :
Block type, plastic case
page 3/0
Schemes : References, characteristics
page 1/120

Non flush mountable in metal


1

Nominal sensing distance (Sn) 2…20 mm 2…20 mm 6…60 mm 6…60 mm


1.3
References

3-wire a Output 0…10 mA (1) XSC-H207629 – XSD-H607629 –


4…14 mA (2)

Output 4…20 mA (2) – XSC-H203629 – XSD-H603629


0…16 mA (1)

Weight (kg) 0.240 0.240 0.480 0.480

Characteristics

Connection Screw terminals, capacity : 2 x 1.5 mm2

Degree of protection IP 67

Operating zone 2…20 mm 6…60 mm

Approvals UL, CSA : please consult your Regional Sales Office

Case type Form C, 5 position turret head Form D, plug-in

Ambient air temperature Operation : - 25…+ 70 °C

Rated supply voltage a 24…48 V a 24 V a 24…48 V a 24 V

Voltage limits (including ripple) a 19…58 V a 19…30 V a 19…58 V a 19…30 V

Current consumption, no-load 4 mA

Output current drift ≤ 10 %


θ ambient : - 25…+ 70 °C

(1) Output current range for “3-wire” connection, see page 1/120.
(2) Output current range for “2-wire” connection, see page 1/120.

1/124 Te
Inductive proximity sensors
For specific applications
Analogue output models
Block type, plastic case
Accessories :
page 3/0
Schemes : Dimensions, setting-up, curves
page 1/120

Dimensions
XSC-H20i629
= =
XSD-H60i629
(2)
1

7,5
20

(2)

=
25

65
92
100
114,5

=
122,5

60

2xØ5,3

(1) 16 65 1.3
40 = =
12 17 (1) = 30 = 80
40 40

(1) n° 13 plastic cable gland (1) n° 13 plastic cable gland


(2) 2 elongated holes 5.3 x 7 (2) 4 holes Ø 5.5 for M5 screw (8 mm max. diameter head).

Setting-up
Minimum mounting distances (mm)
XSC-H20i629 XSD-H60i629
Side by side Face to face Side by side Face to face

e e
e e

e ≥ 80 e ≥ 160 e ≥ 300 not recommended

Facing a metal object and mounting in a metal support :


Refer to “Mechanical installation” for block type proximity sensors mounted in the vicinity of metal masses, page 4/8.

Output curves
XSC-H20i629 XSD-H60i629
Sn = 20 mm Sn = 60 mm
Output current Is (mA)
Output current Is (mA)

1 1
20 20
16 16
2 2
12 12
8 8
4 4
0 0
0 3 6 9 12 15 18 21 24 27 0 10 20 30 40 50 60 70
Sensing distance/object (mm) Sensing distance/object (mm)

1 XSC-H203629 1 XSD-H603629
2 XSC-H207629 2 XSD-H607629

Te 1/125