You are on page 1of 201

AN ISO 9001 & 14001 COMPANY

TENDER DOCUMENT

TENDER No: DLI/CON/759/590

FOR

Construction of 100 bedded Hospital at Bhilai, Chhattisgarh for


Employees State Insurance Corporation (ESIC).

VOLUME – III

Quoting sheet & BOQ


ENGINEERING PROJECTS (INDIA) LTD.
(A GOVERNMENT OF INDIA ENTERPRISE)
QUOTING SHEET FOR BIDDERS

Name of work - Tender for Construction of 100 Bedded Hospital for ESIC at Bhilai

NIT No. DLI/CON/759/590 dated 08.12.2017

TO BE QUOTED BY TENDERER
ESTIMATED
SI. No. Name of work COST (Rs.)
Without Taxes AMOUNT IN Rs. AFTER ADDING %
% (-) BELOW/ AT PAR/(+) ABOVE
(-) BELOW / AT PAR / (+) ABOVE

1 2 3 4 5 = (4 x 3)

In figures In words In figures

Construction of 100 Bedded Hospital for


1 672505366
ESIC at Bhilai

Total

Note:
Rates to be quoted in this tender all inclusive with all taxes and duties etc. including GST.

BIDDERS FINANCIAL OFFER:

(In Figures)______________________________________________________________________________________________________________________________

(In Words)_______________________________________________________________________________________________________________________________

Sign and Stamp of EPIL 200 Sign and Stamp of Bidder


Name of Work : Tender for Construction of 100 Bedded Hospital for ESIC at Bhilai

SUMMARY

SL. No. Description of Item ⁼ Amounts

1 CIVIL ⁼ 420292880.49

2 HVAC ⁼ 30243129.00

3 MEP ⁼ 6860014.00

4 FURNITURE ⁼ 11818620.00

5 OPERATION THEATRE ⁼ 23444706.00

6 TRACK SYSTEM ⁼ 11040000.00

7 KITCHEN EQUIPMENT ⁼ 5728750.00

8 LAUNDRY ⁼ 3079155.00

9 MEDICAL GAS ⁼ 16033000.00

10 SIGNAGE ⁼ 3654353.00

11 TSSU EQUIPMENT ⁼ 4051079.00

12 ELECTRICAL ⁼ 79098580.87

13 FIRE FIGHTING ⁼ 16058225.56

14 PLUMBING 28302872.62

15 LFT = 12800000.00

GRAND TOTAL = 672505365.54

SAY = 672505366

Sign and stamp of EPIL 47 Sign and stamp of bidder


PROJECT: PROPOSED 100 BED ESIC HOSPITAL AT BHILAI, CHHATTISGARH
CIVIL WORKS BOQ

Sl. DSR 2016 TOTAL DSR TOTAL NDSR


DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

EARTH WORKS

Supplying and Filling at site.By Mechanical


1 16.3 Transport including loading, unloading and filling
in building areas.
16.3.9 Good Earth 36426.12 cum 332.55 12113506.85

Earth work in excavation by mechanical means


(Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as
2.6 well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-in-
charge.
2 2.6.1 All kinds of soil 27774.78 cum 125.95 3498233.33

Earth work in excavation by mechanical means


(Hydraulic excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as
2.7 well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-
incharge.
3 2.7.1 Ordinary rock 5476.69 cum 221.05 1210622.30

Earth work in excavation by mechanical means


(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including
2.8 dressing of sides and ramming of bottoms, lift
upto 1.5 m, including getting out the excavated
soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.

1 2.8.1 All kinds of soils 158.00 cum 166.40 26291.87

Filling available excavated earth (excluding rock)


in trenches, plinth, sides of foundations etc. in
layers not exceeding 20cm in depth,
4 2.25 30712.13 cum 125.75 3862049.93
consolidating each deposited layer by ramming
and watering, lead up to 50 m and lift upto 1.5
m.

Supplying and filling in plinth with sand under


5 2.27 floors, including watering, ramming, 450.98 cum 917.75 413888.59
consolidating and dressing complete.

Clearing jungle including uprooting of rank


vegetation, grass, brush wood, trees and
saplings of girth up to 30 cm measured at a
6 2.31 8464.91 sqm 7.20 60947.35
height of 1 m above ground level and removal of
rubbish up to a distance of 50 m outside the
periphery of the area cleared.

Extra for every additional lift of 1.5 m or part


2.26 thereof in excavation / banking excavated or
stacked materials.
7 2.26.1 All kinds of soil
a From 1.5mtr. To 3.0mtr. 10657.36 cum 51.75 551518.33
b From 3.0mtr. To 4.5mtr. 10366.85 cum 103.50 1072968.46
c from 4.5mtr. To 6mtr. 612.80 cum 155.25 95136.58
d from 6mtr. To 7.5mtr. 81.76 cum 207.00 16923.49

Supplying chemical emulsion in sealed


2.34
containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate
8 2.34.1 1321.60 litre 185.95 245752.12
of 20%

Diluting and injecting chemical emulsion for post-


CONSTRUCTIONAL anti-termite treatment
2.35
(excluding the cost of chemical emulsion) :

Sign and Stamp of EPIL 1 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Treatment of soil under existing floors using


chemical emulsion @ one litre per hole, 300 mm
apart including drilling 12 mm diameter holes
2.35.3
and plugging with cement mortar 1 :2 (1 cement
: 2 Coarse sand) to match the existing floor:

With Chlorpyriphos/Lindane E.C. 20% with 1%


9 2.35.3.1 6587.20 sqm 131.90 868851.15
concentration

TOTAL ( EARTH WORKS) 24036690.33 0.00

CONCRETE WORKS

Providing and laying in position cement concrete


of specified grade excluding the cost of
4.1
centering and shuttering - All work up to plinth
level :
1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4
4.1.4 graded stone aggregate 40 mm nominal size). 0.00 cum 5390.45 0.00

1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6


10 4.1.5 graded stone aggregate 20 mm nominal size). 578.85 cum 4927.00 2852011.49
Below GF plinth lvl
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8
4.1.8 graded stone aggregate 40 mm nominal size) 29.09 cum 4478.15 130260.43

1:5:10 (1 cement : 5 coarse sand (zone-III): 10


11 4.1.10 graded stone aggregate 40 mm nominal size). 391.73 cum 4209.05 1648796.32

Providing and fixing up to floor five level precast


cement concrete string or lacing courses,
copings, bed plates, anchor blocks, plain
window sills, shelves, louvers, steps, stair cases,
4.5
etc., including hoisting and setting in position
with cement mortar 1:3 (1 Cement : 3 coarse
sand), cost of required Centering complete.

1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3


12 4.5.1 graded stone aggregate 20mm nominal size). 181.41 cum 6772.45 1228611.51

Making plinth protection 50mm thick of cement


concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size)
over 75mm thick bed of dry brick ballast 40 mm
13 4.17 nominal size, well rammed and consolidated 1151.94 sqm 450.35 518778.12
and grouted with fine sand, including necessary
excavation, levelling & dressing & finishing the
top smooth.

TOTAL (CONCRETE WORKS) 6378457.86 0.00

REINFORCED CEMENT CONCRETE WORK

FORM WORK
Centering and shuttering including strutting,
5.9
propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for
14 5.9.1 2422.08 sqm 193.45 468551.44
mass concrete

Walls (any thickness) including attached


15 5.9.2 pilasters, butteresses, plinth and string courses 2247.59 sqm 378.60 850935.75
etc.

Suspended floors, roofs, landings, balconies and


16 5.9.3 23355.60 sqm 422.30 9863070.13
access platform

17 5.9.4 Shelves (Cast in situ) 207.64 sqm 422.30 87684.81

Lintels, beams, plinth beams, girders,


18 5.9.5 23595.71 sqm 342.90 8090967.25
bressumers and cantilevers

Sign and Stamp of EPIL 2 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Columns, Pillars, Piers, Abutments, Posts and


19 5.9.6 14773.28 sqm 467.85 6911677.42
Struts

Stairs, (excluding landings) except spiral-


20 5.9.7 699.45 sqm 419.35 293314.42
staircases

5.9.16 Edges of slabs and breaks in floors and walls


21 5.9.16.1 Under 20 cm wide 4238.71 meter 122.20 517970.12

Extra for additional height in centering,


shuttering where ever required with adequate
bracing, propping etc., including cost of de-
5.11 shuttering and decentering at all levels, over a
height of 3.5 m, for every additional height of 1
metre or part thereof (Plan area to be
measured).
Suspended floors, roofs, landing, beams and
22 5.11.1 21822.95 sqm 171.50 3742635.79
balconies (Plan area to be measured)

REINFORCED CEMENT CONCRETE


Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
5.22
position and binding all complete upto plinth
level.
Thermo-Mechanically Treated bars of grade Fe-
23 5.22.6 474666.33 kg 56.60 26866114.41
500D or more.

Steel reinforcement for R.C.C. work including


straightening, cutting, bending, placing in
5.22A
position and binding all complete above plinth
level.
Thermo-Mechanically Treated bars of grade Fe-
24 5.22A.6 896978.26 kg 56.60 50768969.60
500 D or more.

Add for plaster drip course/ groove in plastered


5.30 surface or moulding to R.C.C. projections. 66.00 metre 34.15 2253.90

Providing and laying in position ready mixed M-


25 grade concrete for reinforced cement
concrete work, using fly ash and cement content
as per approved design mix, and manufactured
in fully automatic batching plant and transported
to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work, including
5.40 pumping of R.M.C. from transit mixer to site of
laying, excluding the cost of centering,
shuttering, finishing and reinforcement, including
cost of admixtures in recommended proportions
as per IS : 9103 to accelerate / retard setting of
concrete, improve workability without impairing
strength and durability as per direction of the
Engineer - in - charge.

NOTE- (1) Cement content considered in this


item is @ 330 kg/cum. Excess/ less cement
used as per design mix is payable/
recoverable separately.“ (2) Fly ash
conforming to grade I of IS 3812 (Part-1) only
be used as part replacement of OPC as per
IS : 456. Uniform blending with cement to be
ensured in accordance with clauses 5.2 and
5.2.1 of IS:456 -2000 in the items of BMC and
RMC.

Sign and Stamp of EPIL 3 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Note :- The above item shall be used


judiciously where specified quality of Fly Ash
is available for mixing in concrete. Also, the
guidelines issued by CDO, CPWD, vide
circular no. CDO/SE(RR)/Fly Ash (Main)/102
dated 9th April 2009 shall be followed in such
cases.

25 5.40.1 All works upto plinth level 3907.14 cum 6691.85 26145992.14

26 5.40.2 All works above plinth level upto floor V level 7122.40 cum 7495.40 53385215.59

Providing and fixing of expansion joint system


related with floor location as per drawings and
direction of Engineer-In-Charge. The joints
system will be of extruded aluminum base
members, self aligning / self centering
arrangement and support plates etc. as per
ASTM B221-02. The system shall be such that it
5.44
provides floor to floor /floor to wall expansion
control system for various vertical locations in
load application areas that accommodates multi
directional seismic movement without stress to
it's components. System shall consist of metal
profiles with a universal aluminum base member
designed to accommodate various project
The cover plate shall be designed of width and
thickness required to satisfy projects movement
and loading requirements and secured to base
members by utilizing manufacturer‟s pre-
engineered self-centering arrangement that
freely rotates / moves in all directions. The Self -
centering arrangement shall exhibit circular
sphere ends that lock and slide inside the
corresponding aluminum extrusion cavity to
allow freedom of movement and flexure in all
directions including vertical displacement.
Provision of Moisture Barrier Membrane in the
Joint System to have watertight joint is
mandatory requirement all as per the
manufactures design and as approved by
Engineer -in-Charge. (Material shall conform to
ASTM 6063).

27 5.44.1 Floor Joint of 100 mm gap 140.25 metre 4741.05 664932.26

Providing and fixing of expansion joint system


related with wall joint (internal/ external) location
as per drawings and direction of Engineer-In-
Charge. The joints shall be of extruded
aluminum base members, self aligning /
centering arrangement and support plates as
per ASTM B221- 02. The material shall be such
that it provides an Expansion Joints System
suitable for vertical wall to wall/ wall to corner
5.45
application, both new and existing construction
in office Buildings & complexes with no slipping
down tendency amongst the components of the
Joint System. The Joint System shall utilize light
weight aluminum profiles exhibiting minimal
exposed aluminum surfaces mechanically snap
locking the multicellular to facilitate movement.
(Material shall conform to ASTM 6063.)

28 5.45.1 Wall Joint of 100 mm gap 240.35 metre 3928.00 944094.80

Sign and Stamp of EPIL 4 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and fixing of expansion joint system of


approved make and manufacture for various
roof locations as per approved drawings and
direction of Engineer-In-Charge. The joints shall
be of extruded aluminum base members with,
self aligning and self centering arragement
support plates as per ASTM B221-02. The
system shall be such that it provides water tight
roof to roof /roof to corner joint cover expansion
control system that is capable of
accommodating multidirectional seismic
5.46 movement without stress to its components.
System shall consist of metal profile that
incorporates a universal aluminum base
member designed to accommodate various
project conditions and roof treatments. The
cover plate shall be designed of width and
thickness required to satisfy movement and
loading requirements and secured to base
members by utilizing

manufacturer‟s pre-engineered self-centering


arrangement that freely rotates / moves in all
directions. The Self centering arrangement shall
exhibit circular sphere ends that lock and slide
inside the corresponding aluminum extrusion
cavity to allow freedom of movement and flexure
in all directions including vertical displacement.
The Joint System shall resists damage or
deterioration from the impact of falling ice,
exposure to UV, airborne contaminants and
occasional foot traffic from maintenance
personnel. Provision of Moisture Barrier
Membrane in the Joint System to have water
tight joint is mandatory requirement. (Material
shall confirm to ASTM 6063.)

29 5.46.1 Roof Joint of 100 mm gap 28.05 metre 4392.60 123212.43

TOTAL ( REINFORCED CEMENT CONCRETE


189727592.26 0.00
WORK)

BRICK WORK

Brick work with common burnt clay F.P.S. (non


6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
30 6.1.2 972.57 cum 4751.65 4621295.66

Providing and laying autoclaved aerated cement


blocks masonry with 100 mm / 200 mm thick
AAC blocks in super structure above plinth level
up to floor V level in cement mortar 1:4 (1
31 6.38 4832.74 cum 6818.60 32952543.78
cement : 4 coarse sand ). The rate includes
providing and placing in position 2 Nos 6 mm dia
M.S. bars at every third course of masonry work.

Providing and fixing thermal insulation with


Resin Bonded rock wool conforming to IS: 8183,
having density 48 kg/m3, 50 mm thick, wrapped
in 200 G Virgin Polythene Bags fixed to wall with
32 12.62 8154.80 sqm 223.80 1825044.99
screws, rawel plug & washers and held and in
position by criss cossing GI wire etc. complete
as per directions of Engineer-in-Charge.

TOTAL (BRICK WORK) 39398884.43 0.00

MARBLE & GRANITE WORK

Sign and Stamp of EPIL 5 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and fixing 18 mm thick gang saw cut,


mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity
counters, window sills, facias and similar
locations of required size, approved shade,
colour and texture laid over 20 mm thick base
8.2 cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to edges
to give high gloss finish etc. complete at all
levels.

Raj Nagar Plain white marble/ Udaipur green


33 8.2.1
marble/ Zebra black marble
8.2.1.2 Area of slab over 0.50 sqm 89.46 sqm 1850.15 165511.09
8.2.2 Granite of any colour and shade
8.2.2.2 Area of slab over 0.50 sqm 117.81 sqm 3113.30 366778.18

Providing edge moulding to 18 mm thick marble


stone counters, Vanities etc., including machine
8.3 polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-
Charge.
8.3.1 Marble work 128.59 metre 144.70 18606.97
34 8.3.2 Granite work 266.57 metre 245.70 65495.83

Extra for fixing marble /granite stone, over and


above corresponding basic item, in facia and
35 8.4 drops of width upto 150 mm with epoxy resin 395.16 metre 266.25 105210.90
based adhesive, including cleaning etc.
complete.

Extra for providing opening of required size &


shape for wash basin/ kitchen sink in kitchen
platform, vanity counter and similar location in
36 8.5 marble/ Granite/ stone work, including 132.00 each 427.95 56489.40
necessary holes for pillar taps etc. including
moulding, rubbing and polishing of cut edges
etc. complete.

TOTAL (MARBLE & GRANITE WORK) 778092.37 0.00

WOOD & PVC WORK

Providing and fixing ISI marked flush door


shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction
with frame of 1st class hard wood and well
9.21
matched commercial 3 ply veneering with
vertical grains or cross bands and face veneers
on both faces of shutters:

35 mm thick including ISI marked Stainless


37 9.21.1 1249.71 sqm 1559.75 1949235.17
Steel butt hinges with necessary screws

Extra for providing lipping with 2nd class teak


wood battens 25 mm minimum depth on all
38 9.23 1249.71 sqm 365.85 457206.40
edges of flush door shutters (over all area of
door shutter to be measured).

Extra for providing vision panel not exceeding


0.1 sqm in all type of flush doors (cost of glass
9.24
excluded) (overall area of door shutter to be
measured):
39 9.24.1 Rectangular or square 160.23 sqm 162.60 26053.40

Providing and fixing wire gauge shutters using


galvanized M.S. wire gauge of average width of
aperture 1.4 mm in both directions with wire of
9.27
dia 0.63 mm, for doors, windows and clerestory
windows with hinges and necessary screws :

9.27.1 35 mm thick shutters


With ISI marked stainless steel butt hinges of
9.27.1.2
required size
9.27.1.2.1 Second class teak wood 122.64 sqm 3040.30 372862.39

Sign and Stamp of EPIL 6 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing 40x5 mm flat iron hold fast 40 cm long


including fixing to frame with 10 mm diameter
bolts, nuts and wooden plugs and embedding in
9.53 cement concrete block 30x10x15cm 1:3:6 mix (1 36.00 each 118.60 4269.60
cement : 3 coarse sand : 6 graded stone
aggregate 20mm nominal size).

ANODISED ALUMINIUM FITTINGS (ALL


FITTINGS SHALL BE ISI MARKED)
Providing and fixing aluminium sliding door
bolts, ISI marked anodised (anodic coating not
9.96 less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade,
with nuts and screws etc. complete :
40 9.96.1 300x16 mm 714.00 each 212.45 151689.30
41 9.96.2 250x16 mm 720.00 each 189.20 136224.00

Providing and fixing aluminium tower bolts, ISI


marked, anodised (anodic coating not less than
9.97 grade AC 10 as per IS : 1868 ) transparent or
dyed to required colour or shade, with necessary
screws etc. complete :
42 9.97.1 300x10 mm 714.00 each 99.70 71185.80
43 9.97.2 250x10 mm 720.00 each 88.10 63432.00
44 9.97.3 200x10 mm 1434.00 each 76.15 109199.10

Providing and fixing aluminium handles, ISI


marked, anodised (anodic coating not less than
9.100 grade AC 10 as per IS : 1868) transparent or
dyed to required colour or shade, with necessary
screws etc. complete :
45 9.100.1 125 mm 714.00 each 51.10 36485.40
46 9.100.2 100 mm 726.00 each 45.10 32742.60

Providing and fixing aluminium hanging floor


door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS :
9.101
1868) transparent or dyed to required colour and
shade, with necessary screws etc. complete.

47 9.101.2 Twin rubber stopper 720.00 each 38.00 27360.00

Providing and fixing bright finished brass 100


mm mortice latch and lock, ISI marked, with six
levers and a pair of anodised (anodic coating not
48 9.103 717.00 each 622.15 446081.55
less than grade AC 10 as per IS : 1868)
aluminium lever handles of approved quality with
necessary screws etc. complete.

Providing & Fixing decorative high pressure


laminated sheet of plain / wood grain in gloss /
matt/ suede finish with high density protective
9.127 surface layer and reverse side of adhesive
bonding quality conforming to IS : 2046 Type S,
including cost of adhesive of approved quality.

49 9.127.2 1.0 mm thick 1611.54 sqm 518.00 834777.72

Providing and fixing Fiber Glass Reinforced


plastic (FRP) Door Frames of cross-section 90
mm x 45 mm having single rebate of 32 mm x
15 mm to receive shutter of 30 mm thickness
.The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and
50 9.121 chopped mat. Door frame laminate shall be 2 890.40 metre 415.50 369961.20
mm thick and shall be filled with suitable
wooden block in all the three legs. The frame
shall be covered with fiber glass from all sides.
M.S. stay shall be provided at the bottom to
steady the frame.

Sign and Stamp of EPIL 7 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

9.122 Providing and fixing to existing door frames.


30 mm thick Glass Fibre Reinforced Plastic
(FRP) panelled door shutter of required colour
and approved brand and manufacture, made
with fire - retardant grade unsaturated polyester
resin, moulded to 3 mm thick FRP laminate for
forming hollow rails and styles, with wooden
51 9.122.1 frame and suitable blocks of seasoned wood 299.88 sqm 2187.35 655942.52
inside at required places for fixing of fittings, cast
monolithically with 5 mm thick FRP laminate for
panels conforming to IS: 14856, including fixing
to frames.

Providing and fixing factory made uPVC white


colour fixed glazed windows/ventilators
comprising of uPVC multi-chambered frame and
mullion (where ever required) extruded profiles
duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll
forming process of required length (shape & size
9.147B according to uPVC profile), , uPVC extruded
glazing beads of appropriate dimension, EPDM
gasket, G.I fasteners 100 x 8 mm size for fixing
frame to finished wall, plastic packers, plastic
caps and necessary stainless steel screws etc.

Profile of frame shall be mitred cut and fusion


welded at all corners, mullion (if required) shall
be also fusion welded including drilling of holes
for fixing hardware's and drainage of water etc.
After fixing frame the gap between frame and
adjacent finished wall shall be filled with weather
proof silicon sealant over backer rod of required
size and of approved quality, all complete as per
approved drawing & direction of Engineer-in-
Charge. (Single / double glass panes and silicon
sealant shall be paid separately).

Note: For uPVC frame, sash and mullion


extruded profiles minus 5% tolerance in
dimension i.e. in depth & width of profile shall be
acceptable.
Fixed window / ventilator made of (small series)
frame 47 x 50 mm & mullion 47 x 68 mm both
52 9.147B.1 having wall thickness of 1.9 ± 0.2 mm and single 184.20 sqm 5399.70 994624.74
glazing bead of appropriate dimension. (Area
upto 0.75 sqm.)

Providing and fixing factory made uPVC white


colour casement/ Casement cum fixed glazed
door comprising of uPVC multichambered
frame, sash and mullion (where ever required)
extruded profiles duly reinforced with 1.60 ± 0.2
mm thick galvanized mild steel section made
from roll forming process of required length
(shape & size according to uPVC profile), uPVC
9.147C
extruded glazing beads of appropriate
dimension, EPDM gasket, zinc alloy (white
powder coated) 3D hinges and one handle on
each side of panels along with zinc plated mild
steel multi point locking having transmission
gear, cylinder with keeps and one side key,

Sign and Stamp of EPIL 8 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

G.I fasteners 100 x 8 mm size for fixing frame to


finished wall and necessary stainless steel
screws, etc. Profile of frame & sash shall be
mitred cut and fusion welded at all corners,
mullion (if required) shall be also fusion welded
including drilling of holes for fixing hardware's
and drainage of water etc. After fixing frame the
gap between frame and adjacent finished wall
shall be filled with weather proof silicon sealent
over backer rod of required size and of approved
quality, all complete as per approved drawing &
direction of Engineer-in-Charge. (Single / double
glass panes and silicon sealent shall be paid
separately).

Note: For uPVC frame, sash and mullion


extruded profiles minus 5% tolerance in
dimension i.e. in depth & width of profile shall be
acceptable.
Casement door with 3D hinges made of (big
series) frame 67 x 64 mm & sash 67 x 110 mm
both having wall thickness of 2.3 ± 0.2 mm and
53 9.147C.1 305.04 sqm 7859.55 2397477.13
single glazing bead/ double glazing bead of
appropriate dimension. (Area of door upto 2.00
sqm).

Providing and fixing factory made uPVC white


colour sliding glazed window upto 1.50 m in
height dimension comprising of uPVC multi-
chambered frame with in-built roller track and
sash extruded profiles duly reinforced with 1.60
± 0.2 mm thick galvanized mild steel section
made from roll forming process of required
length (shape & size according to uPVC profile),
appropriate dimension of uPVC extruded glazing
beads and uPVC extruded interlocks, EPDM
gasket, wool pile, zinc alloy (white powder
9.147D
coated) touch locks with hook, zinc alloy body
with single nylon rollers (weight bearing capacity
to be 40 kg), G.I fasteners 100 x 8 mm size for
fixing frame to finished wall and necessary
stainless steel screws etc. Profile of frame &
sash shall be mitred cut and fusion welded at all
corners, including drilling of holes for fixing
hardware's and drainage of water etc.

After fixing frame the gap between frame and


adjacent finished wall shall be filled with weather
proof silicon sealent over backer rod of required
size and of approved quality, all complete as per
approved drawing & direction of Engineer-in-
Charge. (Single / double glass panes, wire mesh
and silicon sealant shall be paid separately)

Note: For uPVC frame and sash extruded


profiles minus 5% tolerance in dimension i.e. in
depth & width of profile shall be acceptable.

Three track three panels sliding window with fly


proof SS wire mesh (Two nos. glazed & one no.
wire mesh panels) made of (small series) frame
92 x 44 mm & sash 32 x 60 mm both having wall
9.147D.2 thickness of 1.9 ± 0.2 mm and single glazing 276.96 sqm 7494.70 2075732.11
bead of appropriate dimension (Area of window
upto 1.75 sqm).

Sign and Stamp of EPIL 9 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Three track three panels sliding window with fly


proof S.S wire mesh (Two nos. glazed & one no.
wire mesh panels) made of (big series) frame
116 x 45 mm & sash 46 x 62 mm both having
54 9.147D.4 808.82 sqm 7261.20 5873032.83
wall thickness of 2.3 ± 0.2 mm and single
glazing bead / double glazing bead of
appropriate dimension. (Area of window above
1.75 sqm).

Providing and fixing fly proof stainless steel


grade 304 wire gauge, to windows and
clerestory windows using wire gauge with
9.135 average width of aperture 1.4 mm in both
directions with wire of dia. 0.50 mm all complete.

55 9.135.2 With 12 mm mild steel U beading 673.11 sqm 1094.10 736449.65

Providing and fixing fire resistant door frame of


section 50 x 60 mm on horizontal side & 35 x 60
mm on vertical sides having built in rebate made
out of 1.6 mm thick GI sheet ( Zinc coating not
less than 120gm/m²) suitable for mounting 120
min Fire Rated Glazed Door Shutters. The
frame shall be filled with Mineral wool Insulation
having density min 96Kg/m³ . The frame will
have a provision of G.I. Anchor fastners 14 nos (
5 each on vertical style & 4 on horizontal style of
size M10 x 80 ) suitable for fixing in the opening
56 9.161 176.40 metre 1260.00 222264.00
along with Factory made Template for SS Ball
Bearing Hinges of Size 100x89x3mm for fixing
of fire rated glazed shutter. The frame shall be
finished with a approved fire resistant primer or
Powder coating of not less than 30 micron in
desired shade as per the directions of Engineer -
in- charge . (Cost of SS ball bearing hinges is
excluded).

Providing and fixing 60 mm thick glazed fire


resistant door shutters of 120 min Fire Rating
confirming to IS:3614 (Part II) or EN1634-
1:1999, tested and certified as per laboratory
approved by Engineer-in-charge, with suitable
mounting on door frame, consisting of vertical
styles, top rail & side rail 60 mm x 60 mm wide
and bottom rail of 110 mm x 60 mm made out of
1.6mm thick G.I. sheet (zinc coating not less
57 9.162 than 120gm/m²) duly filled mineral wool 97.02 sqm 6839.35 663553.74
insulation having density min 96 kg/m³ and fixing
with necessary stainless steel ball bearing
hinges of size 100x89x3mm of approved make,
including applying a coat of approved fire
resistant primer or powder coating not less than
30 micron etc all complete as per direction of
Engineer-in-charge (panelling to be paid for
seperately).

Providing and fixing panic bar / latch (Double


point) fitted with a single body, Trim Latch &
Lock on back side of the Panic Latch of reputed
58 9.139 31.00 each 6143.30 190442.30
brand and manufacture to be approved by the
Engineer- in- charge, all complete.

Sign and Stamp of EPIL 10 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing, assembling and supplying vision


glass panels (IGUs) comprising of hermetically-
sealed 6-12- 6 mm insulated glass (double
glazed) vision panel units of size and shape as
required and specified, comprising of an outer
heat strengthened float glass 6mm thick, of
approved colour and shade with reflective soft
coating on surface # 2 of approved colour and
shade, an inner Heat strengthned clear float
glass 6mm thick, spacer tube 12mm wide,
dessicants, including primary seal and
secondary seal (structural silicone sealant) etc.
all complete for the required performances, as
25.3 per the Architectural drawings, as per the
approved shop drawings, as specified and as
directed by the Engineer-in-Charge. The IGUs
shall be assembled in the factory/ workshop of
the glass processor.“(Payment for fixing of IGU
Panels in the curtain glazing is included in cost
of item No.26.2)“For payment, only the actual
area of glass on face # 1 of the glass panels
(excluding the areas of the grooves and weather
silicone sealant) provided and fixed in position,
shall be measured in sqm.

Coloured tinted float glass 6mm thick substrate


with reflective soft coating on face # 2, + 12mm
Airgap + 6mm Heat Strengthened clear Glass of
approved make having properties as visible
Light transmittance (VLT) of 25 to 35 %, Light
reflection internal 10 to 15%, light reflection
(i) 1045.84 sqm 3730.70 3901700.37
external 10 to 20 %, shading coefficient (0.25-
0.28) and U value of 3.0 to 3.3 W/m2 degree K
etc. The properties of performance glass shall
be decided by technical sanctioning authority as
per the site requirement.

9.7.7 Providing and fixing Float glass panes


59 9.7.7.1 4 mm thick glass pane 403.44 sqm 1169.60 471866.23

Extra for providing frosted glass panes 4 mm


thick instead of ordinary float glass panes 4 mm
thick in doors, windows and clerestory window
60 9.12 53.46 sqm 74.35 3974.75
shutters. (Area of opening for glass panes
excluding portion inside rebate shall be
measured).

TOTAL ( Wood & PVC WORK) 23275826.00 0.00

STEEL WORK

Sign and Stamp of EPIL 11 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Structural steel work riveted, bolted or welded in


built up sections, trusses and framed work,
10.2 including cutting, hoisting, fixing in position and 35000.00 kg 67.60 2366000.00
applying a priming coat of approved steel primer
all complete.

Providing and fixing in position collapsible steel


shutters with vertical channels 20x10x2 mm and
braced with flat iron diagonals 20x5 mm size,
with top and bottom rail of T-iron 40x40x6 mm,
10.3 with 40 mm dia steel pulleys, complete with 67.56 sqm 5360.65 362165.51
bolts, nuts, locking arrangement, toppers,
handles, including applying a priming coat of
approved steel primer.

Providing and fixing 1mm thick M.S. sheet door


with frame of 40x40x6 mm angle iron and 3 mm
M.S. gusset plates at the junctions and corners,
10.5
all necessary fittings complete, including
applying a priming coat of approved steel
primer.
Using M.S. angles 40x40x6 mm for diagonal
10.5.1 75.12 sqm 2870.25 215613.18
braces

Supplying and fixing rolling shutters of approved


make, made of required size M.S. laths,
interlocked together through their entire length
and jointed together at the end by end locks,
mounted on specially designed pipe shaft with
brackets, side guides and arrangements for
inside and outside locking with push and pull
10.6 operation complete, including the cost of
providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel
wire of adequate strength conforming to IS:
4454 - part 1 and M.S. top cover of required
thickness for rolling shutters.

80x1.20 mm M.S. laths with 1.20 mm thick top


10.6.2 81.00 sqm 1841.40 149153.40
cover

Providing and fixing ball bearing for rolling


10.7 32.00 each 379.30 12137.60
shutters.

Extra for providing mechanical device chain and


10.8 crank operation for operating rolling shutters.

Exceeding 10.00 sqm and upto 16.80 sqm in the


10.8.1 81.00 sqm 724.05 58648.05
area

Extra for providing grilled rolling shutters


manufactured out of 8 mm dia M.S. bar instead
10.9 of laths as per design approved by Engineer-in- 81.00 sqm 313.60 25401.60
charge,(area of grill to be measured).

Providing and fixing pressed steel door frames


conforming to IS: 4351, manufactured from
commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb,
bead and if required angle threshold of mild
steel angle of section 50x25 mm, or base ties of
1.60 mm, pressed mild steel welded or rigidly
10.14 fixed together by mechanical means, including
M.S. pressed butt hinges 2.5 mm thick with
mortar guards, lock strike-plate and shock
absorbers as specified and applying a coat of
approved steel primer after pre-treatment of the
surface as directed by Engineer-in-charge:

10.14.1 Profile B
Fixing with adjustable lugs with split end tail to
61 10.14.1.1 2683.30 metre 340.35 913261.16
each jamb

Sign and Stamp of EPIL 12 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and fixing circular/ Hexagonal cast


iron or M.S. sheet box for ceiling fan clamp, of
internal dia 140 mm, 73 mm height, top lid of 1.5
mm thick M.S. sheet with its top surface hacked
for proper bonding, top lid shall be screwed into
62 10.18 the cast iron/ M.S. sheet box by means of 3.3 924.00 each 130.10 120212.40
mm dia round headed screws, one lock at the
corners. Clamp shall be made of 12 mm dia
M.S. bar bent to shape as per standard drawing.

Steel work welded in built up sections/ framed


work, including cutting, hoisting, fixing in position
10.25 and applying a priming coat of approved steel
primer using structural steel etc. as required.

In gratings, frames, guard bar, ladder, railings,


63 10.25.2 35197.48 kg 85.95 3025223.45
brackets, gates and similar works

Providing and fixing stainless steel ( Grade 304)


railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories &
64 10.28 stainless steel dash fasteners , stainless steel 14023.19 kg 472.40 6624557.20
bolts etc., of required size, on the top of the floor
or the side of waist slab with suitable
arrangement as per approval of Engineer-in-
charge, (for payment purpose only weight of
stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts,
fasteners etc.).

TOTAL ( STEEL WORK) 13872373.55 0.00

FLOORING WORK

Providing and laying Polished Granite stone


flooring in required design and patterns, in linear
as well as curvilinear portions of the building, all
complete as per the architectural drawings, with
18 mm thick stone slab over 20 mm (average)
8.13 thick base of cement mortar 1:4 (1 cement : 4
coarse sand), laid and jointed with cement slurry
and pointing with white cement slurry admixed
with pigment of matching shade, including
rubbing, curing and polishing etc. all complete
as specified and as directed by the Engineer-in-
Polished Granite stone slab jet Black, Cherry
65 8.13.1 1548.60 sqm 2937.70 4549326.16
Red, Elite Brown, Cat Eye or equivalent.

Extra for pre finished nosing to treads of steps of


11.24 0.00 metre 306.25 0.00
marble / Granite stone.

Extra for marble / Granite stone flooring in


11.25 treads of steps and risers using single length up 24.00 sqm 357.95 8590.80
to 2.00 metre.

Chequerred precast cement concrete tiles 22


mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to match
11.20 the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of
cement mortar 1:4 (1 cement: 4 coarse sand).

66 11.20.4 Ordinary cement without any pigment 1051.00 sqm 661.35 695075.54

Sign and Stamp of EPIL 13 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Kota stone slab flooring over 20 mm (average)


thick base laid over and jointed with grey cement
slurry mixed with pigment to match the shade of
11.26
the slab, including rubbing and polishing
complete with base of cement mortar 1 : 4 (1
cement : 4 coarse sand) :
67 11.26.1 25 mm thick 8356.64 sqm 1158.10 9677828.61

Kota stone slabs 20 mm thick in risers of steps,


skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement: 3
81 11.27 coarse sand) and jointed with grey cement slurry 810.65 sqm 1238.20 1003744.21
mixed with pigment to match the shade of the
slabs, including rubbing and polishing complete.

Extra for pre finished nosing in treads of steps of


11.31 252.00 sqm 84.85 21382.20
Kota stone/ sand stone slab.

25 mm wooden planking, tongued and grooved


11.33 in flooring, including fixing with iron screws
complete with :
69 11.33.2 Second class deodar wood 45.21 sqm 2307.80 104333.10

Providing and fixing Ist quality ceramic glazed


wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps
70 11.36 14469.79 sqm 744.80 10777098.49
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.

Providing and fixing 1st quality ceramic glazed


floor tiles conforming to IS : 15622 (thickness to
be specified by the manufacturer ) of approved
make in all colours, shades except burgundy,
bottle green, black of any size as approved by
Engineer-in-Charge in skirting, risers of steps
11.37A and dados over 12 mm thick bed of cement 98.45 sqm 660.20 64996.69
Mortar 1:3 (1 cement: 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm including pointing in white cement mixed
with pigment of
matching shade complete.

Providing and laying rectified Glazed Ceramic


floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer),
of 1st quality conforming to IS : 15622, of
approved make, in all colours, shades, except
71 11.40 White, Ivory, Grey, Fume Red Brown, laid on 20 2682.50 sqm 901.05 2417068.25
mm thick Cement Mortar 1:4 (1 Cement : 4
Coarse sand), jointing with grey cement slurry @
3.3kg/sqm including pointing the joints with
white cement and matching pigments etc.,
complete.

Providing and laying vitrified floor tiles in


different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved
11.41 make, in all colours and shades, laid on 20mm
thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @
3.3kg/sqm including grouting the joints with
white cement and matching pigments etc.,
72 11.41.2 Size of Tile 600x600 mm 2154.90 sqm 1119.40 2412195.06

Sign and Stamp of EPIL 14 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Marble stone flooring with 18 mm thick marble


stone, as per sample of marble approved by
Engineer-in-charge, over 20 mm (average) thick
11.23 base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with grey cement slurry,
including rubbing and polishing complete with :

73 11.23.1 Makrana white second quality 777.70 sqm 2724.75 2119038.08

Chequerred precast cement concrete tiles 22


mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to match
11.20 the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of
cement mortar 1:4 (1 cement: 4 coarse sand).

11.20.4 Ordinary cement without any pigment 170.31 sqm 661.35 112636.50

TOTAL ( FLOORING WORK) 33963313.67 0.00

ROOFING WORK

Providing gola 75x75 mm in cement concrete


1:2:4 (1 cement : 2 coarse sand : 4 stone
aggregate 10 mm and down gauge), including
12.21
finishing with cement mortar 1:3 (1 cement : 3
fine sand) as per standard design :

74 12.21.1 In 75x75 mm deep chase 1220.53 metre 153.00 186741.47

Making khurras 45x45 cm with average


minimum thickness of 5 cm cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C.
75 12.22 sheet 1 m x1 m x 400 micron, finished with 12 41.00 each 187.60 7691.60
mm cement plaster 1:3 (1 cement : 3 coarse
sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet
complete.

Providing and fixing false ceiling at all height


including providing and fixing of frame work
made of special sections, power pressed from
M.S. sheets and galvanized with zinc coating of
120 gms/sqm (both side inclusive) as per IS :
277 and consisting of angle cleats of size 25
mm wide x 1.6 mm thick with flanges of 27 mm
and 37mm, at 1200 mm centre to centre, one
flange fixed to the ceiling with dash fastener
12.45 12.5 mm dia x 50mm long with 6mm dia bolts,
other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts &
bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200
mm centre to centre, to which the ceiling section
0.5 mm thick bottom wedge of 80 mm with

tapered flanges of 26 mm each having lips of


10.5 mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made
out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the
perimeter of ceiling fixed to wall/partition with the
help of rawl plugs at 450 mm centre, with 25mm
long dry wall screws @ 230 mm interval,
including fixing of gypsum board

Sign and Stamp of EPIL 15 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

to ceiling section and perimeter channel with


the help of dry wall screws of size 3.5 x 25 mm
at 230 mm c/c, including jointing and finishing to
a flush finish of tapered and square edges of the
board with recommended jointing compound ,
jointing tapes , finishing with jointing compound
in 3 layers covering upto 150 mm on both sides
of joint and two coats of primer suitable for
board, all as per manufacturer's specification
and also including the cost of making openings
for light fittings, grills, diffusers, cutouts made
with frame of perimeter channels suitably fixed,
all complete as per drawings, specification and
direction of the Engineer in Charge but
excluding the cost of painting with :

12.5 mm thick tapered edge gypsum fire


76 12.45.2 1217.70 sqm 922.05 1122780.29
resistant board conforming to IS: 2095-Part I

Providing and fixing tiled false ceiling of


specified materials of size 595x595 mm in true
horizontal level, suspended on inter locking
metal grid of hot dipped galvanized steel
sections ( galvanized @ 120 grams/ sqm, both
side inclusive) consisting of main "T" runner with
suitably spaced joints to get required length and
12.52
of size 24x38 mm made from 0.30 mm thick
(minimum) sheet, spaced at 1200 mm center to
center and cross "T" of size 24x25 mm made of
0.30 mm thick (minimum) sheet, 1200 mm long
spaced between main "T" at 600 mm center to
center to

form a grid of 1200x600 mm and secondary


cross "T" of length 600 mm and size 24x25 mm
made of 0.30 mm thick (minimum) sheet to be
interlocked at middle of the 1200x600 mm panel
to form grids of 600x600 mm and wall angle of
size 24x24x0.3 mm and laying false ceiling tiles
of approved texture in the grid including,
required cutting/making, opening for services
like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main "T" runners to be suspended
from ceiling using GI slotted cleats of size 27 x
37 x 25 x1.6 mm fixed to ceiling with 12.5 mm
dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanised butterfly level
clips of size 85 x 30 x 0.8 mm spaced at 1200
mm center to center along main T, bottom
exposed width of 24 mm of all T-sections shall
be pre-painted with polyester paint, all complete
for all heights as per specifications, drawings
GI Metal Ceiling Lay in plain Tegular edge
Global white color tiles of size 595x595 mm, and
0.5 mm thick with 8 mm drop; made of G I sheet
having galvanizing of 100 gms/sqm (both sides
77 12.52.1 3247.20 sqm 1041.95 3383420.04
inclusive) and electro statically polyester powder
coated of thickness 60 microns (minimum),
including factory painted after bending.

TOTAL (Carried Over to Summary of


4700633.40 0.00
ROOFING WORK)

FINISHING WORK

For Internal Finishing


13.1 12 mm cement plaster of mix :
13.1.2 1:6 (1 cement: 6 fine sand) 2030.73 sqm 160.35 325627.47

15 mm cement plaster on the rough side of


13.2
single or half brick wall of mix :
13.2.2 1:6 (1 cement: 6 fine sand) 147.55 sqm 185.20 27325.80

13.4 12 mm cement plaster of mix :


78 13.4.2 1:6 (1 cement: 6 coarse sand) 30911.26 sqm 168.25 5200820.13

Sign and Stamp of EPIL 16 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

13.6 20 mm cement plaster of mix :


13.6.2 1:6 (1 cement: 6 coarse sand) 173.82 sqm 232.85 40474.96

Cement plaster 1:3 (1 cement: 3 coarse sand)


13.9 finished with a floating coat of neat cement.

13.9.1 12 mm cement plaster 1787.81 sqm 234.70 419598.54

13.16 6 mm cement plaster of mix :


79 13.16.1 1:3 (1 cement : 3 fine sand) 8841.87 sqm 143.80 1271460.50

Providing and applying plaster of paris putty of 2


mm thickness over plastered surface to prepare
80 13.26 262.48 sqm 118.70 31156.57
the surface even and smooth complete.

White washing with lime to give an even shade :


13.37
81 13.37.1 New work (three or more coats) 3214.51 sqm 17.25 55450.30

Distempering with oil bound washable distemper


13.41 of approved brand and manufacture to give an
even shade :
New work (two or more coats) over and
82 13.41.1 including water thinnable priming coat with 7717.19 sqm 93.70 723100.95
cement primer

Finishing walls with water proofing cement paint


13.44 of required shade : FOR EXTERNAL WALLS
ONLY
New work (Two or more coats applied @ 3.84
13.44.1 89.34 sqm 58.80 5252.93
kg/10 sqm)

Painting with synthetic enamel paint of approved


13.61 brand and manufacture to give an even shade :

13.61.1 Two or more coats on new work 633.09 sqm 78.40 49634.21

Providing and applying white cement based


putty of average thickness 1 mm, of approved
83 13.80 brand and manufacturer, over the plastered wall 38245.85 sqm 87.35 3340775.41
surface to prepare the surface even and smooth
complete.

Wall painting with acrylic emulsion paint, having


VOC (Volatile Organic Compound ) content less
than 50 grams/ litre, of approved brand and
13.82
manufacture, including applying additional coats
wherever required, to achieve even shade and
colour.
84 13.82.2 Two coats 38551.02 sqm 73.90 2848920.39

Painting with synthetic enamel paint, having


VOC (Volatile Organic Compound) content less
than 150 grams/ litre, of approved brand and
13.84
manufacture, including applying additional coats
wherever required to achieve even shade and
colour.
85 13.84.2 Two coats 2650.58 sqm 75.00 198793.71

Applying priming coats with primer of approved


13.85 brand and manufacture, having low VOC
(Volatile Organic Compound ) content.
With ready mixed red oxide zinc chromatic on
86 13.85.2 steel / iron works having VOC content less than 2561.16 sqm 32.55 83365.77
250 grams/ litre
With water thinnable cement primer on wall
87 13.85.3 surface having VOC content less than 50 38551.02 sqm 36.95 1424460.20
grams/litre

For External Finishing

Sign and Stamp of EPIL 17 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Washed stone grit plaster on exterior walls


height upto 10 metre above ground level, in two
layers, under layer 12 mm cement plaster 1:4 (1
cement : 4 coarse sand ), furrowing the under
layer with scratching tool, applying cement slurry
on the under layer @ 2 Kg of cement per square
metre, top layer 15 mm cement plaster 1:1/ 2:2
(1 cement: 1/2 coarse sand : 2 stone chipping 582.60
88 13.72 20809.94 sqm 12123869.30
10 mm nominal size), in panels with groove all
around as per approved pattern, including
scrubbing and washing the top layer with
brushes and water to expose the stone
chippings ,complete as per specification and
direction of Engineer-in- charge (payment for
providing grooves shall be made separately).

Extra for washed grit plaster on exterior walls of


height more than 10 m from ground level for
89 13.74 8749.79 sqm 85.90 751607.24
every additional height of 3 m or part thereof.

Forming groove of uniform size in the top layer


of washed stone grit plaster as per approved
pattern using wooden battens, nailed to the
under layer, including removal of wooden
13.73
battens, repair to the edges of panels and
finishing the groove complete as per
specifications and direction of the Engineer-in-
charge :
90 13.73.1 15 mm wide and 15 mm deep groove 42904.63 metre 34.40 1475919.27

Extra for using white cement in place of ordinary


91 13.77 cement in the top layer of the item of washed 20071.88 sqm 63.90 1282592.92
stone grit plaster.

Finishing walls with Premium Acrylic Smooth


13.47 exterior paint with Silicone additives of required
shade:
New work (Two or more coats applied @ 1.43
ltr/10 sqm over and including priming coat of
13.47.1 1500.00 sqm 96.80 145200.00
exterior primer applied @ 2.20 kg/10 sqm)

Providing and fixing concertina coil fencing with


punched tape concertina coil 600 mm dia 10
metre openable length ( total length 90 m),
having 50 nos rounds per 6 metre length, upto 3
m height of wall with existing angle iron 'Y'
shaped placed 2.4 m or 3.00 m apart and with 9
horizontal R.B.T. reinforced barbed wire, stud
tied with G.I. staples and G.I. clips to retain
20 16.53 horizontal, including necessary bolts or G.I. 611.34 metre 255.00 155890.68
barbed wire tied to angle iron, all complete as
per direction of Engineer-in-charge, with
reinforced barbed tape(R.B.T.) / Spring core
(2.5mm thick) wire of high tensile strength of
165 kg/ sq.mm with tape (0.52 mm thick) and
weight 43.478 gm/metre (cost of M.S. angle,
C.C. blocks shall be paid separately)

Sign and Stamp of EPIL 18 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Boring, providing and installation bored cast-in-


situ reinforced cement concrete piles of grade M-
25 of specified diameter and length below the
pile cap, to carry a safe working load not less
than specified, excluding the cost of steel
reinforcement but including the cost of boring
with bentonite solution and temporary casing of
appropriate length for setting out and removal of
20.2 same and the length of the pile to be embedded
in the pile cap etc. by percussion drilling using
Direct mud circulation (DMC) or Bailer and
chisel technique by tripod and mechanical
Winch Machine all complete, including removal
of excavated earth with all its lifts and leads
(length of pile for payment shall be measured up
to bottom of pile cap).

Note: Truck Mounted rotary/TMR/Tubewell


boring machine shall not be used.
21 20.2.1 450 mm dia piles 1769.62 metre 1496.45 2648142.79

Vertical load testing of piles in accordance with


IS 2911 (Part IV) including installation of loading
platform by Kentledge/Anchor piles method and
preparation of pile head or construction of test
20.6
cap and dismantling of test cap after test etc.
complete as per specification & the direction of
Engineer in-charge.

Note: 1. Initial and Routine Load Test shall not


be carried out by Dynamic method of testing.
Note: 2. Testing agency shall submitt the design
of loading platform for the approval of Engineer-
in-charge.
20.6.1 Single pile upto 50 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe
22 20.6.1.1 1.00 per test 38561.80 38561.80
capacity)
Routine test (Test Load 1.5 times the Safe
23 20.6.1.2 2.00 per test 17422.50 34845.00
capacity)

TOTAL (Finishing WORK) 31825406.56 0.00

ALUMINIUM WORK

Providing and fixing double action hydraulic floor


spring of approved brand and manufacture
conforming to IS : 6315, having brand logo
embossed on the body / plate with double spring
mechanism and door weight upto 125 kg, for
doors, including cost of cutting floors,
21.4 embedding in floors as required and making
good the same matching to the existing floor
finishing and cover plates with brass pivot and
single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of
Engineer-in-charge.

With stainless steel cover plate minimum 1.25


92 21.4.1 22.00 each 2054.40 45196.80
mm thickness

TOTAL ( Aluminium WORK) 45196.80 0.00

WATER PROOFING

Sign and Stamp of EPIL 19 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and laying integral cement based


treatment for water proofing on horizontal
surface at all depth below ground level for under
ground structures as directed by Engineer-in-
Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved
and specified rough stone slab over a 25 mm
thick base of cement mortar 1:3 (1 cement : 3
coarse sand) mixed with water proofing
compound conforming to IS:2645 in the
recommended proportion over the leveling
22.1 course (leveling course to be paid separately).
Joints sealed and grouted with cement slurry
mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3
(1 cement: 3 coarse sand) mixed with water
proofing compound in recommended
proportions.
(iii) Finishing top with stone aggregate of 10 mm
to 12 mm nominal size spreading @ 8
cudm/sqm thoroughly embedded in the 2nd
layer.

22.1.1 Using rough kota stone. 626.05 sqm 1017.55 637041.25

Providing and laying integral cement based


treatment for water proofing on the vertical
surface by fixing specified stone slab 22 mm to
25 mm thick with cement slurry mixed with water
proofing compound conforming to IS:2645 in
recommended proportions with a gap of 20 mm
(minimum) between stone slabs and the
22.2 receiving surfaces and filling the gaps with neat
cement slurry mixed with water proofing
compound and finishing the exterior of stone
slab with cement mortar 1:3 (1 cement : 3
coarse sand) 20 mm thick with neat cement
punning mixed with water proofing compound in
recommended proportion complete at all levels
and as directed by Engineer-in-charge :

22.2.1 Using rough Kota stone 881.56 sqm 1253.30 1104861.65

Providing and laying water proofing treatment to


vertical and horizontal surfaces of depressed
portions of W.C., kitchen and the like consisting
of:
(i) Ist course of applying cement slurry @ 4.4
kg/sqm mixed with water proofing compound
conforming to IS 2645 in recommended
proportions including rounding off junction of
vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1
22.3 cement : 3 coarse sand) mixed with water 229.01 sqm 505.90 115855.65
proofing compound in recommended proportion
including rounding off junction of vertical and
horizontal surface.
(iii) IIIrd course of applying blown or residual
bitumen applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet.
(Overlaps at joints of PVC sheet should be 100
mm wide and pasted to each other
with bitumen @ 1.7 kg/ sqm).

Sign and Stamp of EPIL 20 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing orange colour safety foot rest of


minimum 6 mm thick plastic encapsulated as
per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross
section as 23 mmx25 mm and over all minimum
length 263 mm and width as 165 mm with
minimum 112 mm space between protruded
legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and
19.16 adequate anchoring projections on tail length on 192.00 each 327.90 62956.80
138 mm as per standard drawing and suitable to
with stand the bend test and chemical resistance
test as per specifications and having
manufacture's permanent identification mark to
be visible even after fixing, including fixing in
manholes with 30x20x15 cm cement concrete
block 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) complete
as per design.

Providing and laying water proofing treatment in


sunken portion of WCs, bathroom etc., by
applying cement slurry mixed with water proofing
cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing cement
compound @ 0.253 kg/ sqm. This layer will be
allowed to air cure for 4 hours.
93 22.5 (b) Second layer of slurry of cement @ 0.242 1049.88 sqm 298.30 313180.67
kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be
allowed to air cure for 4 hours followed with
water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of
all joints, corners, junctions of pipes and
masonry with polymer mixed slurry.

For Terrace
Providing and laying water proofing treatment on
roofs of slabs by applying cement slurry mixed
with water proofing cement compound
consisting of applying:
(a) after surface preparation, first layer of slurry
22.6 of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/sqm.
(b) laying second layer of Fibre glass cloth when
the first layer is still green. Overlaps of joints of
fibre cloth should not be less than 10 cm.

(c) third layer of 1.5 mm thickness consisting of


slurry of cement @ 1.289 kg/sqm mixed with
water proofing cement compound @ 0.670
kg/sqm and coarse sand @ 1.289 kg/sqm. This
will be allowed to air cure for 4 hours followed by
water curing for 48 hours. The entire treatment
will be taken upto 30 cm on parapet wall and
94 4269.85 sqm 395.00 1686590.83
tucked into groove in parapet all around.
(d) fourth and final layer of brick tiling with
cement mortar (which will be paid for
separately.For the purpose of measurement the
entire treated surface will be measured.

Sign and Stamp of EPIL 21 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and laying integral cement based


water proofing treatment including preparation of
surface as required for treatment of roofs,
balconies, terraces etc consisting of following
operations:
(a) Applying a slurry coat of neat cement using
2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC
slab including adjoining walls upto 300 mm
height including cleaning the surface before
treatment.
(b) Laying brick bats with mortar using broken
22.7 bricks/brick bats 25 mm to 115 mm size with
50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound
conforming to IS : 2645 and approved by
Engineer-in-charge over 20 mm thick layer of
cement mortar of mix 1:5 (1 cement :5 coarse
sand) admixed with water proofing compound
conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and
treating similarly the adjoining walls upto 300
mm height including rounding of junctions of
walls and slabs.
(c) After two days of proper curing applying a
second coat of cement slurry using 2.75 kg/ sqm
of cement
With admixed
average with waterofproofing
thickness 120 mm and
22.7.1 948.99 sqm 1034.65 981869.40
minimum thickness at khurra as 65 mm.

Providing and laying roof insulation with 40 mm


thick impervious sprayed, closed cell free Rigid
Polyurethane foam over deck insulation
conforming to IS - 12432 Pt. III (density of foam
being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre,
laying 400 G polythene sheet over PUF spray
95 12.56 and providing a wearing course of 40 mm thick 3308.51 sqm 1151.05 3808265.04
cement screed 1:2:4 (1 cement : 2 coarse sand :
4 stone aggregate 20 mm nominal size) in
chequered rough finish, in panels of 2.5 m x 2.5
m and embedding with 24 G wire netting and
sealing the joints with polymerized mastic, all
complete as per direction of Engineer-in-Charge.

Providing and laying Ceramic glazed floor tiles


of size 300x300 mm (thickness to be specified
by the manufacturer) of 1st quality conforming to
IS : 15622 of approved make in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20
96 11.37 4269.85 sqm 688.35 2939151.39
mm thick cement mortar 1:4 (1 Cement : 4
Coarse sand), jointing with grey cement slurry @
3.3kg/sqm including pointing the joints with
white cement and matching pigment etc.,
complete.

1:3:6 (1 Cement : 3 coarse sand (zone-III): 6


97 4.1.6 graded stone aggregate 40 mm nominal size). 320.24 cum 4814.55 1541805.55

TOTAL (WATER PROOFING WORK) 13191578.23 0.00

ROAD WORKS

Preparation and consolidation of sub grade with


power road roller of 8 to 12 tonne capacity after
excavating earth to an average of 22.5 cm
depth, dressing to camber and consolidating
1 16.1 7887.45 sqm 90.10 710658.84
with road roller including making good the
undulations etc. and re-rolling the sub grade and
disposal of surplus earth with lead upto 50
metres.

Sign and Stamp of EPIL 22 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Extra for compaction of earth work in


embankment under optimum moisture
2 16.2 7493.07 cum 10.70 80175.88
conditions to give at least 95% of the maximum
dry density (proctor density).

16.3 Supplying and stacking at site.


3 16.3.1 90 mm to 45 mm size stone aggregate 867.62 cum 1336.05 1159182.37

4 16.3.2 63 mm to 45 mm size stone aggregate 591.56 cum 1449.30 857345.61

5 16.3.3 53 mm to 22.4 mm size stone aggregate 473.25 cum 1542.25 729864.77

Stone screening 13.2 mm nominal size (Type A)


6 16.3.6 197.19 cum 1505.60 296883.45

Stone screening 11.2 mm nominal size (Type B)


7 16.3.7 118.31 cum 1462.05 172977.60

Good earth ( FILLING AT SITE SUPLLY FROM


8 16.3.9 5 KM. AWYE TO SITE LUMSUM DISTANCE 2789.33 cum 332.55 927591.60
TAKEN )

9 16.3.10 Moorum 193.24 cum 643.20 124293.52

Laying, spreading and compacting stone


aggregate of specified sizes to WBM
specifications in uniform thickness, hand
picking, rolling with 3 wheeled road / vibratory
roller 8-10 tonne capacity in stages to proper
10 16.4 2366.23 cum 449.10 1062675.53
grade and camber, applying and brooming
requisite type of screening / binding material to
fill up interstices of coarse aggregate, watering
and compacting to the required density .

Steel reinforcement for R.C.C. work including


straightening, cutting, bending, placing in
5.22
position and binding all complete upto plinth
level.
Thermo-Mechanically Treated bars of grade Fe-
5.22.6 48438.76 kg 56.60 2741634.04
500D or more.

Cement concrete 1:2:4 (1 cement : 2 coarse


sand : 4 graded stone aggregate 40 mm
nominal size) in pavements, laid to required
16.42 605.48 cum 5503.80 3332465.87
slope and camber in panels as required
including consolidation finishing and tamping
complete.

"Providing and laying design mix cement


concrete of M-30 grade, in roads/ taxi tracks/
runways, using cement content as per design
mix, using coarse sand and graded stone
aggregate of 40 mm nominal size in appropriate
proportions as per approved & specified design
criteria, providing dowel bars with sleeve/ tie
bars wherever required, laying at site, spreading
and compacting mechanically by using needle
and surface vibrators, levelling to required slope/
16.43 camber, finishing with required texture, including
steel form work with sturdy M.S. channel
sections, curing, making provision for
contraction/ expansion, construction &
longitudinal joints ( 10 mm wide x 50 mm deep)
by groove cutting machine, providing and filling
joints with approved joint filler and sealants,
complete all as per direction of Engineer-in-
charge (Item of joint fillers, sealants, dowel bars
with sleeve/ tie bars to be paid separately).
Note:- Cement content considered in M-30 is @
Cement concrete manufactured in automatic
12 16.43.2 batching plant (RMC plant) i/c transportation to 1210.97 cum 7160.40 8671023.14
site in transit mixer

Extra for providing and mixing hardening


compound of approved quality as per
16.44 968.78 litre 46.45 44999.61
manufacturer's specification in cement concrete.

Sign and Stamp of EPIL 23 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and fixing in position pre-moulded joint


per cm
filler in expansion joints.
depth per
16.45 2665.98 cm width 2.20 5865.16
per m
length

Providing and laying in position bitumen hot


16.46
sealing compound for expansion joints etc.
Using grade 'A' sealing compound. per cm
depth per
16.46.1 2665.98 cm 2.20 5865.16
width per
m length

Providing and fixing precoated galvanised iron


profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
0.50 mm (+ 0.05 %) total coated thickness with
zinc coating 120 grams per sqm as per IS: 277,
in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester
top coat 15-18 microns. Sheet should have
protective guard film of 25 microns minimum to
12.50 avoid scratches during transportation and should 2943.23 sqm 550.40 1619951.59
be supplied in single length upto 12 metre or as
desired by Engineerin- charge. The sheet shall
be fixed using self drilling /self tapping screws of
size (5.5x 55 mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.

Structural steel work riveted, bolted or welded in built


up sections, trusses and framed work, including
10.2 cutting, hoisting, fixing in position and applying a 35318.71 kg 67.60 2387544.93
priming coat of approved steel primer all complete.

Painting with synthetic enamel paint of approved


13.61
brand and manufacture to give an even shade :
13.61.1 Two or more coats on new work 8829.68 sqm 78.40 692246.76

PAINTING ROAD / RUNWAY MARKING


Painting runway/taxi track/apron marking with
adequate nos of coats to give uniform finish with
road marking paint of superior make as
16.47 approved by the Engineer-in-charge, i/c cleaning
the surface of ail dirt, scales, oil, grease and
other foreign mater;al etc. and lining out
complete.
13 16.47.1 New work (Two or more coats) 6054.85 sqm 104.90 635153.29

Making bell mouth opening/ entrance of size


100x50x50 cm for drainage pipe under footpath,
including providing cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) for shape of bell
mouth, including plastering providing and fixing
14 16.49 precast R.C.C./ S.F.R.C. slab including 10.00 each 1829.70 18297.00
plastering with cement mortar 1:3 (1 cement : 3
fine sand) of 6 mm thickness on exposed
surface of the slab & bell mouth including
centring, shuttering & neat cement punning
inside the bell mouth etc. all complete.

Sign and Stamp of EPIL 24 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Providing and laying 60mm thick faciory made


cement concrete interlocking paver block of M -
30 grade made by block making machine with
strong vibratory compaction, of approved s;ze,
design & shape, laid in required colour and
15 16.68 2264.02 sqm 615.70 1393957.11
pattern over and including 50mm thick
compacted bed of coarse sand, filling the joints
with line sandetc. all complete as per the
direction of Engineer-in-charge.

Providing and laying at or near ground level


factory made kerb stone of M-25 grade cement
concrete in position to the required line, level
and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints
with or without grooves (thickness of joints
except at sharp curve shall not to more than
16 16.69 129.01 cum 5012.65 646682.57
5mm), including making drainage opening
wherever required complete etc. as per direction
of Engineer-in-charge (length of finished kerb
edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by
Engineer-in-charge).

Providing and laying non-pressure NP2 class


(light duty) R.C.C. pipes with collars jointed with
19.6 stiff mixture of cement mortar in the proportion of
1:2 (1 cement : 2 fine sand) including testing of
joints etc. complete :
17 19.6.2 150 mm dia. R.C.C. pipe 285.60 metre 356.70 101873.52

TOTAL of ROAD WORKS) 28419208.91 0.00

ROAD SIDE DRAIN WORK

Brick work with common burnt clay F.P.S. (non


6.1 modular) bricks of class designation 7.5 in foundation
and plinth in:
18 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 337.25 cum 4751.65 1602477.19

Providing and laying in position cement concrete


of specified grade excluding the cost of
4.1
centering and shuttering - All work up to plinth
level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3
19 4.1.2 graded stone aggregate 20 mm nominal size). 22.48 cum 5924.65 133204.49

1:5:10 (1 cement : 5 coarse sand (zone-III): 10


20 4.1.10 graded stone aggregate 40 mm nominal size). 69.60 cum 4209.05 292949.25

13.4 12 mm cement plaster of mix :


21 13.4.1 1:4 (1 cement: 4 coarse sand) 4477.07 sqm 180.85 809677.94

22 13.18 Neat cement punning. 2238.53 sqm 42.60 95361.57

Providing and fixing factory made precast RCC


perforated drain covers, having concrete of
strength not less than M-25, of size 1000 x
450x50 mm, reinforced with 8 mm dia four nos
longitudinal & 9 nos cross sectional T.M.T. hoop
23 23.9 bars, including providing 50 mm dia perforations 2273.00 each 959.35 2180602.55
@ 100 to 125 mm c/c, including providing edge
binding with M.S. flats of size 50 mm x 1.6 mm
complete, all as per direction of Engineerin-
charge.

TOTAL ( ROAD SIDE DRAIN WORK) 5114272.99 0.00

Sign and Stamp of EPIL 25 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

HORTICULTURE WORK
Supplying and stacking at site dump manure
from approved source, including carriage upto 5
2.4
km complete (manure measured in stacks will
be reduced by 8% for payment) :
Screened through sieve of I.S. designation 20
24 2567.72 cum 170.70 438309.68
2.4.1 mm

Mixing earth and sludge or manure in the


25 2.9 required proportion specified or directed by the 2567.72 cum 21.35 54820.81
Officer-in-charge

Grassing with selection No. 1 grass including


watering and maintenance of the lawn for 60
days or more till the grass forms a thick lawn,
2.10
free from weeds and fit for mowing including
supplying good earth, if needed (the grass and
earth shall be paid for separately).
26 2.10.1 In rows 5 cm apart in both directions 12838.60 Sqm 10.40 133521.40

Renovating lawns including weeding, cheeling


the grass, forking the ground, top dressing with
sludge or manure, mixing the same with forked
soil, watering and maintaining the lawn for 60
days or more till the grass forms a thick lawn
27 2.11 free from weeds and fit for mowing and disposal 12838.60 Sqm 20.15 258697.72
of rubbish as directed, including supplying good
earth if needed but excluding the cost of sludge
or manure (The manure/sludge shall be paid for
separately).

Preparation of beds for hedging and shrubbery


by excavating 60 cm deep and trenching the
excavated base to a further depth of 30 cm,
refilling the excavated earth after breaking clods
and mixing with sludge or manure in the ratio of
8:1 (8 parts of stacked volume of earth after
reduction by 20% : one part of stacked volume
of sludge or manure after reduction by 8%),
28 2.13 flooding with water, filling with earth if necessary, 2567.72 cum 130.35 334702.21
watering and finally fine dressing, leveling etc.
including stacking and disposal of materials
declared unserviceable and surplus earth by
spreading and leveling as directed, within a lead
of 50 m, lift up to 1.5 m complete (cost of
sludge, manure or extra earth to be paid for
separately)

TOTAL ( HORTICULTURE WORK) 1220051.83 0.00

MISS. WORK

Providing & fixing Chicken wire mesh on joints


of RCC & Brick work before plastering complete
98 MR 1700.12 sqm 131.00 222715.66
in the direction of Engineer-in-charge.

RCC Core cut : Drilling with core cutting


machine in RCC beams,slabs,floorsetc.,for
laying pipes and rendering the same in RCC
1:2:4 finishing the same to the satisifaction of
the owner or his authorised representative
etc.,including nominal reinforcement wherever
MR
required,complete,at all levels The quote shall
also include for providing EPOXY based water
proofing compound for sealing the joints around
the pipes upto any depth at all heights & levels.

99 A)100mm dia. (At All Floor) 348.00 no's 465.00 161820.00


100 b)200mm dia. (At All Floor) 348.00 no's 581.00 202188.00

Sign and Stamp of EPIL 26 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Self Leveling Compound


Providing & Laying of 2 - 3 mm average thick
layer of cementations smoothening compound
of ARDEX CL-11 or equivalent as
recommended by the Vinyl sheet flooring
manufacturer over and including a priming
compound of P-51 or equivalent as
101 MR 276.44 sqm 568.00 157018.49
recommended by the Vinyl sheet flooring
manufacturer and installation team on concrete
surface to provide a smooth & homogenous
surface for laying of vinyl sheet flooring
complete to the entire satisfaction of Engineer-in-
charge

FOR OT AREA- CONDUCTIVE


Supply and installation of PASTELL Conductive
Vinyl Sheet Flooring manufactured by Armstrong
or equivalent World Industries, Inc, 1.83m wide,
having a nominal total thickness of 2.2mm. The
nominal thickness of the wear layer would be 2
mm. The product should have a conductive
backing of 0.2mm. The wear surface shall
consist of impregnated polyurethane
homogeneous mixture of PVC, Plasticizers,
Urethane, color pigments and filler calendared to
form a sheet. Colors and pattern detail shall be
dispersed throughout the thickness of the wear
layer. PASTELL Conductive shall conform to
Group P of Wear Resistance as per EN 649,
Flammability of class Bfl-s1 as per EN 13501-1,
Slip resistance of R9 as per BGR 181, Dynamic
Coefficient of friction as DS as per EN 13893,
Impact sound reduction of 3 dB as per EN ISO
140-8,

Residual indentation of 0.05 mm as per EN


433, Color fastness rating ≥6 as per ISO 105-
B02, Vertical resistance(R1) less than 106Ω as
per EN 1081, Static electrical charge of ≤2.0kV
as per EN 1815, Thermal resistance of
0.01m²K/W as per EN 12667, Thermal
conductivity of 0.25 W/mK as per EN 12524.
102 113.25 sqm 2892.00 327504.54
PASTELL conductive shall exhibit ESD
properties as following - Vertical resistance less
than 3.5x10^6Ω as per EN 61340-4-1, Static
electrical charge - system test less than 100V as
per EN 61340-4-5.The class of use of PASTELL
Conductive is 23/34/43 as per EN 685.

ROLLER BLINDS
Providing and fixing Roller Blinds with roller
tube, bottom bar leveller made of extruded
aluminium alloy an Idler, Insert Type- Brackets,
103 NSR
powder coated PVC chain etc. all complete at all
floor and heights as per approved manufacturer
specification .

Sign and Stamp of EPIL 27 Sign and Stamp of Bidder


Sl. DSR 2016 TOTAL DSR TOTAL NDSR
DESCRIPTION OF ITEMS Total Qty. Unit DSR Rate NDSR Rate
No. & MR Amount Amount

Roller Tube Control, Clutch, Idler


Side by side or single Roller Tube of extruded
Aluminium alloy 6060-T66-EN755 with powder
coated (50 micron thickness) 38- 41mm outer
dia minimum wall thickness of 1.6mm having in
built spring-clutch system. Clutch shall be made
of carbon steel spring wrapped by means of a
high strength fiberglass reinforced polyester
assembly to transmit motion from driving to
driven members of clutch mechanism. Clutch
shall operate bi- directionally with the use of an
endless PVC bead chain.Clutch mechanism
shall be crash proof, prevent slippage and shall
raise and lower smoothly to any desired height.
Clutch shall never need any adjustment. Idler
shall be of high strength fiberglass reinforced
polyster,consisting of an outside sleeve and
centre shaft. Sleeve shall provide bearing
surface for roller tube
Brackets-Insert and rotate
Type-Fit freely Tube
with Roller on centre
Ceiling or side mounting brackets shall be of
made up of stainless steel of grade 304 and
powder coated with 50 micron thickness.
Bottom Rail
Bottom of the blind shall be provided with
extruded aluminium tube having weight 390
gm/meter in round/oval/ square shape fitted with
end caps powder coated (50 micron thickness)
in desired colour matching to the fabric. The
fabric shall be enclosed in the suitably created
pocket along with the tube.

PVC Ball Chain


The Control Unit and powder coated PVC Chain
with a Ball Pitch of no lesser than 6.5mm consist
of bead chain, bead chain stop, Tension device
and bead chain connector pully ito match the
fabric shall be provided to ensure an enduring
operation alongwith an aesthetic value.

ROLLER BLIND FABRIC SPECIFICATION


Roller blind fabric made up of 25% Polyester
and 75% PVC. Lead free fabric with 5%
opening, thickness of 0.91mm, with UV
Blockage of 95%, Solar Reflectance of 62%,
solar absorption of 16%, solar transmittance
22%, acoustical value NRC-0.10/SAA-0.09
having Greenguard Gold certification for low
chemical emissions, Bacterial and Fungal
Resistance as per ASTM E 2180, ASTM G21,
AATCC30 part 3, ASTM D 3273, Greenguard.
Mold and Bacterial standard ASTM 6329, with
Microban anti- microbial protection. Flame 1019.88 sqm 2926.00 2984168.88
retardant as per California US Title 19(Small
Scale), NFPA 701-2004 TM#1 (small scale),
NFPA 101 (Class A rating), IBC section 903.1
(Class A rating), BS 5867 2008 Part 2 Type B
Performance, CAN/ULC-S-109-03 (large and
small scale) and CAN/CGSB2-4.162-M80, STM
E 84(Class 1) NFPA 701 TM#2 (large scale)
with 10 years of interior warranty. Make Phifer
USA

Extra thickness of mortar for maching flooring


NSR 4831.43 sqm 60.00 289885.73
diffrance in tile & kata stone

TOTAL MISS. WORK) 0.00 4345301.29


Total 415947579.20 4345301.29

Grand Total 420292880.49

Sign and Stamp of EPIL 28 Sign and Stamp of Bidder


PROJECT: PROPOSED 100 BED ESIC HOSPITAL AT BHILAI, CHHATTISGARH
HVAC Work BOQ
DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1 EQUIPMENT

1.1 WATER COOLED SCREW CHILLER

Supply,Installation, Testing and commissioning of imported


best efficiency factory designed and pre-fabricated Vapor
Compression screw water chilling machines with variable
frequency drive (VFD) starter,including one or more
horizontal/vertical,Open type /hermatic/semihermetic type
compressors. , of twin screw type , equipped with even pass
water cooled condenser of shell and tube type as per the
specifications as detailed earlier in the document.The
compressor motor shall be suitable for VFD operations on 415
+/- 10% Volts , 3 Phase , 50 Hz., and shall be direct coupled
type .The chiller shall be even pass & Flooded type complete
insulated with approved insulating masterial , Refrigerant
piping shall be factory assembled as per the specifications
detailed in the related section , or as per the specifications of
the approved vendor , whichever is more stringent.

The chiller assembly will be delivered with the charge of the


refrigerant and compressor oil Gauge panel, drive package,
VFD Starter, control panel and associated wiring,BMS Card
and all other accessories to make the chiller package ready
for installation and commissioning., and most efficient NPLV
of less than 0.39 IKW/TR.

The various other parameters governing the selection and


capacity computations of the chiller package are as follows:
Condenser water in : 90 Deg F , Condenser water out : 97.5
Deg F , Fouling Factor : 0.001 FPS
Chilled water in : 54 Deg F , Chilled water out : 44 Deg F ,
Chiller Fouling factor : 0.0005 FPS
COP @ Conditions: Shall be as per latest relevant ECBC
standards. ( Minimum 5.4 COP)
Power Consumption @ Full Load at tender conditions: Shall
not be more than or equal to 0.75 Ikw/TR.
NPLV: Shall be less than 0.39 Ikw/TR. Procedure for
calculations shall be as per AHRI guidelines.
Installation, Testing and commissioning of factory designed
and pre-fabricated Vapor Compression refrigeration water
chilling machines of following actual capacity as described
above and in the specifications.The refrigerant acceptable is
R -134A .
100 TR Actual Capacity water cooled screw type chiller
1.1.1 3 No. 2,419,313.00 7,257,939.00
(2#Working +1# Standby)
CIF, Bhillai (Chhatisgarh)
Customs duty, CVD, Auxiliary duty
Clearing, port handling and other incidental charges.
Loading, Local transportation and all other incidental charges
upto delivery at site.

Sign and Stamp of EPIL 29 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Installation, testing and commissioning

1.2 Hot water generator


Supply Installation,testing and commissioning of Hot water
generator as per specifications .
Inlet Water Temperature 50 °C
Outlet Water Temperature 55 °C
200.0 KW Hot water generator (with multiple circuit) (1
1.2.1 1 No. 290,318.00 290,318.00
Working + 0 Standby)

1.3 PUMP SETS


1.3.1 CONDENSER WATER PUMPS
Supply,installation,testing and commissioning of horizontal
End Suction/split casing centrifugal pumps for condenser
water recirculation , complete with TEFC squirrel cage
motors, base plate, and all necessary accessories.Capacity of
pump sets , nett head is as given below:All the pumps
mentioned below shall also be complete with mechanical
seals, and drain connections , and shall be suitable for
operation on 415+/- 10 % Volts , 50 Hz , 3 Phase AC power
supply.
a. 400 USGPM * 25 M for Screw chiller, (2Working + 1Standby) 3 No. 169,493.00 508,479.00

1.3.2 PRIMARY CHILLED/HOT WATER PUMPS (FIXED SPEED)

Primary circuit:Supply, installation, testing and


commissioning of end suction/monoblock centrifugal pumps
for chilled water/Hot Water recirculation, complete with
TEFC squirrel cage motors, base plate, and all necessary
accessories. Capacity of pump sets, nett head is as given
below: All the pumps mentioned below shall also be complete
with mechanical seals, and drain connections, and shall be
suitable for operation on 415±10% Volts, 50 Hz, 3 Phase AC
power supply.
240 USGPM * 15 M for primary Chilled/Hot water circuit
a. 3 No. 105,523.00 316,569.00
(2Working + 1Standby)

Sign and Stamp of EPIL 30 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1.3.3 VARIABLE SPEED PUMPING SYSTEM

Supply, installation, testing and commissioning of centrifugal


end suction pumps factory mounted on a common base with
electric motor for re circulation of water for the central air
conditioning system.. The pump motor shall be suitable for
415± 10% volts, 50 cycles, 3 phase AC power supply.
Secondary chilled water pumps shall be suitable for operation
on adjustable frequency drives .Secondary Variable Speed
Pumping System consisting of 3No.’s adjustable frequency
drives (one dedicated for each pump)( 1 # provision for
future), 1 No. Microprocessor based Pump Logic Controller
for controlling 2 working +1(stand-by) pumps in parallel , 1
No. Flow Sensor / Transmitter, & 3 No.’s Diffrential Pressure
sensors / Transmitters.

The Pump Logic Controller shall be capable of accepting


analog inputs from Flow Sensor / Transmitter & from Kw
Sensor / Transmitter to provide lowest Kw draw based on
Efficiency Optimisation Program & multiple differential
pressure sensor / transmitters. Controller shall be capable of
accepting input from flow sensor transmitter,to ensure end of
the curve protection.
The system shall be complete in all respects and suitable for
following ratings and duty.
240 USGPM * 25 M for Chilled/hot water circuit (2Working +
a. 3 No. 213,233.00 639,699.00
1Standby)

1.4 COOLING TOWERS

Supply, installation , testing and commissioning of Vertical


Induced draft or cross flow design cooling towers , in
accordance with the specifications laid out earlier in this
document under the related chapter, and in accordance with
BS-4485.The cooling tower shall be of FRP construction ,
complete with sump and aluminum ladder , isolating switch
and other accessories to make it fully operational and
maintainable.The maximum allowable sound power at a
distance of 3 M from the fan shall be up to 80 DB(A). The
cooling tower model shall be selected to suit site conditions.

Entering water temperature :97°F, Leaving water temperature


: 90°F.
Type of fan : Propeller .Type of motor : 710 RPM , Weather
proof.
Water Flow rate : 400 USGPM , 125 TR (Based on Ludhiana
a. ambient condition: Max WB 83 Deg F, Approach of 7 Deg F) , 2 No. 235,923.00 471,846.00
cooling tower blower fan or motors (cooling tower 2w+ 0S)

Sign and Stamp of EPIL 31 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1.5 AIR HANDLERS (With One Coil System)
Supply, installation testing and commissioning of factory built
floor mounted chilled water Double skin type
horizintal/vertical air handling units made of 25mm ±2mm
thick panels consisting of pre plasticized GI casing of thickness
0.8mm outside layerand 0.8mm inside layer with
polyurethene foam (PUF) insulation factory injected between
them by injection moulding machine, complete with blower
section with blower suitable for static pressure as required ,
min. 2 bend GSS/PVC eliminators, cooling coil section with
aluminium finned copper tubes ( tube thickness not less than
0.5 mm ) cooling coil of 6 row deep, filter section with 50 mm
thick metal viscous filter /washable synthetic type air
prefilters, belt drive/ direct driven package with TEFC drive
motor of efficiency class IE3 suitable for 415±10% V, 50Hz, 3
phase AC supply suitably designed for variable frequency
drive applications, drain connections , stainless steel (18G)
drain pain with PUF insulation,150 mm dia. dial type pressure
gauges (2 Nter two days of proper curing applying a
second coat of cement slurry using 2.75 kg/ sqm of cement
admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick joi

Supply , installation testing and commissioning of Double skin


floor mounted Horizontal/vertical Two pipe system (One coil)
AHUs as per the mentioned in AHU schedule. (All AHU
Should Be BMS/VFD Compitable)
Note: If AHU With fine filter or Fine and Hepa Filter than
these filters with sections shall be separate considerable as
defined below in this boq item no. 4.11.
Double skin floor mounted Horizontal two pipe system (one
coil)AHU 6500 CFM / 12.0 TR, 6 row deep chilled water coil ,
a 16.26.6 1 No. 163,967.00 163,967.00
pre & Fine filter, 80 mm SP WG with three phase motor and
Mixing Box . (For MRI , GF)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 4000 CFM / 7.5 TR, 6 row deep chilled water
b 16.26.3 1 No. 100,009.00 100,009.00
coil , pre & fine filter and Mixing Box, 65 mm SP WG with
three phase motor , (For CT Scan, GF)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 2000 CFM / 4.0 TR, 6 row deep chilled water
c 16.26.1 1 No. 75,410.00 75,410.00
coil , pre & fine filter and Mixing Box, 65 mm SP WG with
three phase motor , (For Triage, GF)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 1500 CFM / 4.0 TR, 6 row deep chilled water
d 16.26.1 coil , pre & fine filter and Mixing Box, 65 mm SP WG with 1 No. 75,410.00 75,410.00
three phase motor , (For Observation, GF)

Sign and Stamp of EPIL 32 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 2500 CFM / 4.0 TR, 6 row deep chilled water
e 16.26.1 coil , pre & fine filter and Mixing Box, 65 mm SP WG with 1 No. 75,410.00 75,410.00
three phase motor , (For Minor OT, GF )

Double skin floor mounted Horizontal two pipe system (one


coil)AHU 5000 CFM / 10.0 TR, 6 row deep chilled water coil ,
f 16.26.4 1 No. 124,770.00 124,770.00
pre & Fine filter, 80 mm SP WG with three phase motor and
Mixing Box . (For Pathology , 1st)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 3500 CFM / 8.0 TR, 6 row deep chilled water
g 16.26.3 coil , pre & fine filter and Mixing Box, 65 mm SP WG with 1 No. 100,009.00 100,009.00
three phase motor , (For Blood Bank,1st )

Double skin floor mounted Horizontal two pipe system (one


coil)AHU 2500 CFM / 4.5 TR, 4 row deep chilled water coil ,
h 16.26.1 1 No. 75,410.00 75,410.00
pre & Fine filter, 80 mm SP WG with three phase motor and
Mixing Box . (For Dialysis , 2nd)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 1500 CFM / 3.5 TR, 6 row deep chilled water
i 16.26.1 coil , pre & fine filter and Mixing Box, 65 mm SP WG with 1 No. 75,410.00 75,410.00
three phase motor , (For Cath Recovery,2nd )

Double skin Ceiling mounted Horizontal two pipe system


(one coil)AHU 2500 CFM / 5.0 TR, 6 row deep chilled water
j 16.26.1 coil , pre & Fine filter, 65 mm SP WG with three phase motor 1 No. 75,410.00 75,410.00
and Mixing Box . (For Cath Lab , 2nd)

Double skin Ceiling mounted Horizontal two pipe system


(one coil)AHU 2500 CFM / 5.0 TR, 6 row deep chilled water
k 16.26.1 coil , pre & Fine filter, 65 mm SP WG with three phase motor 3 No. 75,410.00 226,230.00
and Mixing Box . (For Delivery,Recovery,Nursery Room , 3rd)

Double skin Ceiling mounted Horizontal two pipe system


(one coil)AHU 3500 CFM / 6.0 TR, 6 row deep chilled water
l 16.26.3 1 No. 100,009.00 100,009.00
coil , pre & Fine filter, 65 mm SP WG with three phase motor
. (For Labour Room, 3rd)
Double skin Ceiling mounted Horizontal two pipe system
(one coil)AHU 5000 CFM / 8.0 TR, 4 row deep chilled water
m 16.26.4 1 No. 124,770.00 124,770.00
coil , pre filter, 35 mm SP WG with three phase motor and
Mixing Box . (For LabourRecept. , 3rd)
Double skin floor mounted Horizontal two pipe system (one
coil)AHU 7500 CFM / 14.0 TR, 6 row deep chilled water coil ,
n 16.26.7 pre & Fine filter, 80 mm SP WG with three phase motor and 1 No. 182,033.00 182,033.00
Mixing Box,weather proof canopy . (For ICU , 3rd)

Double skin floor mounted Horizontal two pipe system (one


coil)AHU 7000 CFM / 13.0 TR, 6 row deep chilled water coil ,
o 16.26.6 pre & Fine filter, 80 mm SP WG with three phase motor and 1 No. 163,967.00 163,967.00
Mixing Box,weather proof canopy . (For Recovery Beds , 3rd)

Sign and Stamp of EPIL 33 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Double skin floor mounted Horizontal two pipe system (one
coil)AHU 9000 CFM / 18.0 TR, 6 row deep chilled water coil ,
p 16.26.8 pre & Fine filter, 80 mm SP WG with three phase motor and 1 No. 199,212.00 199,212.00
Mixing Box,. (For Sterile Corridor , 3rd)

Floor Mounted Horizontal Air Handling Units With Exh.


1.6
Blower and Enthalpy Recovery Wheel (FM AHU)

Supply, Installation Testing and Commissioning of floor


mounted AHU's. The AHU's shall be double skin type made of
0.60 mm thick GI sheet with 23+/-2mm for indoor application
and 43+/-2 mm Thick for outdoor application PUF insulation.
The Drain Pan for AHU's shall be of SS. They shall be suitable
for indoor/outdoor installation. The AHU's selected shall be
supplied with Forward / Backward direct driven/belt driven
supply air Blower Fans and exh. air blower with Ethalpy
Recovery Wheel (Min. Efficiency of HRW is 75%) (ERW/HRW)
suitable to deliver the undergiven CFM and Static. The AHU's
shall be chilled water coil ( complete with mixing chamber if
required and electrical push buttnos. Cooling Coil)on starting
panel for operating the AHU. AHU Included VI Pads .

All AHU Should Be included Supply/Return/Fresh Air Damper


& Thermal Break Profile and with three phase motor suitable
for VSD drive and BMS Compitable
Double skin floor mounted Horizontal 8-Row Depth chilled
water Coil (1 Coil) with Supply Fan 1600 CFM with pre, fine
and Hepa filter on terminal, S.P. is 115 mm & Exhaust fan
a 2000 CFM with Pre & HEPA Filter, S.P. 80 mm , Heat Recovery 1 No. 381,150.00 381,150.00
Wheel (Enthalpy Wheel) AHU Coil is 5.0 TR, pre filter with
mixing box & Weather Proof Canopy. (For Isolation Room,
2nd Floor)
Double skin floor mounted Horizontal 8-Row Depth chilled
water Coil (1 Coil) with Supply Fan 4000 CFM with pre, fine
and Hepa filter on terminal, S.P. is 125 mm & Exhaust fan
b 3500 CFM with Pre & HEPA Filter, S.P. 80 mm , Heat Recovery 2 No. 658,845.00 1,317,690.00
Wheel (Enthalpy Wheel) AHU Coil is 15.0 TR, pre filter with
mixing box & Weather Proof Canopy. (For OT-1,3, 3rd Floor)

Double skin floor mounted Horizontal 8-Row Depth chilled


water Coil (1 Coil) with Supply Fan 3500 CFM with pre, fine
and Hepa filter on terminal, S.P. is 125 mm & Exhaust fan
c 3000 CFM with Pre & HEPA Filter, S.P. 80 mm , Heat Recovery 1 No. 658,845.00 658,845.00
Wheel (Enthalpy Wheel) AHU Coil is 13.0 TR, pre filter with
mixing box & Weather Proof Canopy. (For OT-2, 3rd Floor)

Sign and Stamp of EPIL 34 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1.7 FAN COIL UNITS (Standard)

Supply,Installation , testing and commissioning of fan coil


units of specified capacities and air flow as per the
specifications , complete with auxillary drain pan.

Fan coil unit shall be supplied with approved make of factory


fitted adequately sized insulated (with nitrile foam) two way
motorized valves , insulated ball valves-one with Y strainer,
and the other without Y strainer complete with room
thermostat for fan speed control , associated conduiting and
wiring between the thermostat , 2 - way valve .etc.
Cost of fan coil unit shall be inclusive of approved make room
thermostat (heatig and cooling, with fan speed control), and
associated wiring etc.between the thermostat and two way
valve , for a standard length of approximately 5-7 M per fan
coil unit.
Providing and fixing in position the following Fan Coil
units complete with all valves and accessories as described
above.
a 1.5 TR nominal capacity ( 600 CFM) 1 No. 17,969.00 17,969.00
b 2.0 TR nominal capacity ( 800 CFM) 3 No. 20,147.00 60,441.00

c 2.5 TR nominal capacity ( 1000 CFM) 8 No. 22,325.00 178,600.00

d 3.0 TR nominal capacity ( 1200 CFM) 8 No. 24,503.00 196,024.00

1.8 Propeller fan


Supply,installation,testing and commissioning of Propeller fan
of the following capacity of approved make and specification.
Fan shall be supplied with aluminum gravity louver & bird
screen and Speed Regulator.

a 150 mm dia propeller fan, with single phase motor 7 No. 2,995.00 20,965.00

b 300 mm dia propeller fan, with single phase motor 9 No. 3,321.00 29,889.00

c 450 mm dia propeller fan , with single phase motor 1 No. 3,975.00 3,975.00

1.9 Inline fan


Supply, installation, testing and commissioning of Circular
swing type Inline fan with fiire retardent Canvas connection
of the following capacity of approved make and specification.

a 100 to 300 CFM, 5-7 mm SP WG with Single phase motor 6 No. 6,580.00 39,480.00

b 400 to 500 CFM, 7-10 mm SP WG with Single phase motor 11 No. 6,580.00 72,380.00

c 600 CFM, 10-12 mm SP WG with Single phase motor 6 No. 8,168.00 49,008.00

d 700 to 800 CFM, 10-12 mm SP WG with Single phase motor 40 No. 9,257.00 370,280.00

e 900 CFM, 12-15 mm SP WG with Single phase motor 8 No. 12,315.00 98,520.00

f 1000 CFM, 12-15 mm SP WG with Single phase motor 1 No. 15,019.00 15,019.00

Sign and Stamp of EPIL 35 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code

1.10 FAN SECTIONS/ Cabinet fan :

Supply,Installation ,Testing and commissioning of approved


make of ventilation AMCA Certified Cabinet Fan of Double
SKIN CONSTRUCTION, belt driven centrifugal fan ,mounted on
floating foundation of spring mounted vibration isolators ,
and canvass connection , squirrel cage induction motor ,
mounted within the housing , and all other details as called
for in the drawings , specifications. Fan section shall be
suitable for floor / ceiling mounted application as detailed in
the drawings).The fan motor shall be suitable for operation
on Single speed , 415 ± 15 Volts, 50Hz,AC power supply.

Ventilation fan sections of single skin construction as


described above and in the specifications DIDW type,motor
within the casing.All fans shall have single speed motors Cost
to be inclusive of unit isolator.

800 CFM, 3PH/4P, 80 mm WG static pressure with VSD


a compatible motor suitable for floor/Ceiling mounted 1 No. 44,105.00 44,105.00
application.(For OT Scrub Exhaust )

1.11 Tube Axial Flow fans


SITC of Tube axial flow fans, as per specifications and
approved makes suitable for three phase operation at 1450
RPM respectively Normal/Smoke case.
AMCA Certified tube axial flow fans complete with all
accessories, suitable for wall mounted / ceiling suspended
installation. The fan shall be supplied with suitable 3PH/2P
motor at 2960 RPM , and shall be selected for 30 mm static
pressure (WG), (F Class motor insulation) All fan with fiire
retardent Canvas connection.(For Smoke make up air) Fans
capacity as per below mentioned as: (As per Vent. Fan
Schedule)
a 3000 CFM (For Hospital Liftwell Pressurization) 2 No. 39,749.00 79,498.00
b 5000 CFM (For Residential Liftwell Pressurization) 1 No. 46,283.00 46,283.00
c 16000 CFM (For Residential Liftlobby Pressurization) 1 No. 85,487.00 85,487.00

1.12 Evaporative air cooler(Air Washer)


Supply , Install, test and commission double skin Evaporative
air washer as per specifications , suitable for the following
capacity given below at 75-90% efficiency of evaporative
medium. The fan shall be of DIDW centrifugal construction.
Packaged Type
Ventilation fan sections of double skin construction as
described above and in the specifications DIDW type,motor
within the casing.All fans shall have multi speed motors Cost
to be inclusive of unit isolator and .25HP-0.5HP water pump.
Fan Motor VFD Compitable. AS PER SPEC.

12500 CFM, 3PH, 40 mm WG static pressure,960 rpm, 1.5HP


a motor with Speed controller for floor mounted with weather 1 No. 174,240.00 174,240.00
proof canopy

Sign and Stamp of EPIL 36 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1.13 Air Scrubber (Wet Type)

Supply , Install, test and commission air Scrubber of


approved make and specifications. (The scrubber will be of
the similar construction as that of the double skin air
washer,except for that the system shall have the following
exceptional features: BACKWARD CURVED DIDW FAN, spray
bank comprising of brass nozzles - instead of the cellulose
pad evaporative medium , expanded viscous metal filters )

a 15000 CFM 80 mm sp for Kitchen Exh. 1 No. 206,910.00 206,910.00

1.14 AIR DIFFERENTIAL PRESSURE SWITCH


Supply,install,test and commission Air Differential pressure
switches complete with sensor probe , etc. integrated with
Light and visual alarm signal, as per general details and
specifications and approved make.To be installed across HEPA
filter bank sections and Operating rooms.The necessary
control and power wiring shall be in the scope of the
contractor.
Air Differential Pressure Switch. ( ACROSS OT & Isolation
a 6 Set 5,479.00 32,874.00
rooms.)

1.15 Temperature and RH sensor and adjuster package.

Supply,install-(grout),test and commission micro-processor


based Room temperature , humidity sensor and remote
adjuster package within a MS housing -wall ,suitable for
mounting, and having a stainless steel cover plate.This
package shall have a temperature and humidity display - red
2" high LED character for operation rooms , and other critical
areas.

Sensor, adjuster (Snap acting humidistat/Proportional


a thermostat- Microprocessor based) and displayer package, as 4 Set 19,602.00 78,408.00
described above.

1.16 Pan Type humidifier and humidistat

a Supply, install, test and commission snap acting humidistat . 3 No. 13,122.00 39,366.00

Supply, install, test and commission wall / floor mounted Pan


b
Type Humidifier package of following capacities.

b1 4.0 KW 3 No. 35,578.00 106,734.00

Sign and Stamp of EPIL 37 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1.17 Variable speed drives.
Supply of following HVAC dedicated VFDs with IP 20
enclosures , complying with the tender specifications and
having:
1. built-in dual 5% impedance DC link reactor (harmonic
filters) on the positive and negative rails of the DC bus of the
VFD.
2. built-in EMC Filters (electromagnetic compatibility filters)
for for VFDs for restriction of conducted emissions to comply
with IEC61800: 3 (unrestricted distribution):2004 Category C
3,
3. Three-feedback PID controller having capability to
simultaneously accept 3 feedback signals from temperature
sensors or pressure sensors or CO2 sensors for process
optimization and accordingly regulate the speed of the AHUs
or pumps.
4. Provision for additional 3 PID controllers to control external
devices such as chilled water modulating valve, fresh air
damper, etc. thus reducing the number of I/Os in DDC
Controllers & improving system reliability.
5. Automatic Energy Optimization / Load dependent flux
optimization functionality for maximum energy savings.
6. MODBUS RTU as the communication protocol between
BMS & VFDs.
7. VFDs not meeting above requirements shall provide
external disconnect, additional external EMC Filters to comply
with IEC61800: 3 (unrestricted distribution):2004 Category C 3
(50 m), external PLCs / DDCs to achieve 3 Feedback PID
Supply , Install, test and commission Variable Speed Drive
package as described above and in specifications suitable for
for 1.5 kW motor rating as per the specifications(3 Phase
variable frequency output for OT's AHU Scrub Exh. Fan,
a Isolation AHU and Exh.. These variable speed drives shall get 3 No. 27,225.00 81,675.00
the input from the remote air differential pressure adjuster ,
as described above in item.

Supply , Install, test and commission Variable Speed Drive


package as described above and in specifications suitable for
for 3.7 kW motor rating as per the specifications(3 Phase
variable frequency output for OT's AHU and Exh.. These
b variable speed drives shall get the input from the remote air 4 No. 33,215.00 132,860.00
differential pressure adjuster , as described above in item.

Supply , Install, test and commission Variable Speed Drive


package as described above and in specifications suitable for
for 5.5 kW motor rating as per the specifications(3 Phase
c 2 No. 41,927.00 83,854.00
variable frequency output for OT's AHU and Exh.. These
variable speed drives shall get the input from the remote air
differential pressure adjuster , as described above in item.

TOTAL (EQUIPMENT) 16,124,815.00

Sign and Stamp of EPIL 38 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code

2 Chilled water Piping , Valves & Accessories (Including Insulation)


2.1 EXPANSION TANK
Supply, Installation ,Testing and commissioning of Open
expansion tank as per the specifications detailed earlier in
the relevant section .The Open vessel expansion tank shall be
complete with all accessories so as to make it ready for
installation and commissioning on site.The tank shall be
insulated with the approved method of insulation , and shall
be complete with water make-up connection and system
.The expansion tank will be supplied,Non return Valve and
interconnecting piping.

1000 Ltr . Open Expansion Tank duly insulated and with all
a 1 No. 40,896.00 40,896.00
accessories.

2.2 CHILLED WATER PIPING (Including Nitrile Rubber Insulation)

Providing and fixing in position the following MS C


class chilled water piping , cut to required length, and
installed with welded joints (USE RECTIFIER AS SPECIFIED),
including all necessary fittings such as elbows , tees , etc.and
confirming to the specifications as detailed in the relevant
chapter in the document. Pipes will be accepted in order of
preference (Factory fabricated / Fabricated out of 7mm thick
plates duly rolled in a workshop and welded : for pipes
beyond 350mm dia)

Chilled water pipes shall be insulated with 19/32 mm thick


closed cell elastometric Nitrile rubber of min. 45 kg/m3
density, thermal conductivity 0.037w/mk or better at 20°
mean temp. class'O' insulation applied by suitable adhesive
complete including repairing of damage to building etc. for
chilled water piping as per specifications (Above nitrile foam
2 coat layer 7 mile cloth star bond/Insu sound insulation)

Note: The pipes of sizes 150mm & below shall be M.S. 'C'
class as per IS:1239 and Pipes size above 150 mm shall be
welded black steel pipe heavy class as per IS: 3589, from
min. 6.35 mm thick M.S. sheet for pipes up to 350 mm dia.
And from min. 7 mm thick MS sheet for Pipes of 400 mm
dia. and above.
Insulation specification and finishing material remains same
for the valves and drain pipes as per specifications.

a 16.2.7 125mm dia (32mm thick insulation) 10 RM 2,142.00 21,420.00


b 16.2.8 100mm dia (32mm thick insulation) 80 RM 1,709.00 136,720.00

c 16.2.9 80mm dia (32mm thick insulation) 100 RM 1,255.00 125,500.00

d 16.2.10 65mm dia (32mm thick insulation) 110 RM 1,030.00 113,300.00

Sign and Stamp of EPIL 39 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
e 16.2.11 50mm dia (32mm thick insulation) 100 RM 881.00 88,100.00

f 16.2.12 40mm dia (32mm thick insulation) 180 RM 702.00 126,360.00

g 16.2.13 32mm dia(19mm thick insulation) 220 RM 564.00 124,080.00

h 16.2.14 25mm dia (19 mm thick insulation) 200 RM 463.00 92,600.00

CHILLED WATER PIPING (Including resin bonded fiber


2.3
glass/EPS Insulation)

Providing and fixing in position the following MS 'C' class


chilled water piping, cut to required length, and installed with
welded joints (USE RECTIFIER AS SPECIFIED), including all
necessary fittings such as elbows, tees, etc. and confirming to
the specifications as detailed in the relevant chapter in the
document. Pipes will be accepted in order of preference
(Factory fabricated / Fabricated out of 7mm thick plates duly
rolled in a workshop and welded : for pipes beyond 350mm
dia)

Chilled water pipes shall be insulated with fire retardent


quality expanded polystrene moulded pipe section of density
20 kg/cum. after a thick coat of cold setting adhesive(CPRX
compound) wrapping with 500g polythene faced hessain and
finally applying 0.63 mm aluminium sheet cladding complete
with type 3, grade 1 roofing feltstrip (As per IS:1322 as
amended up to date)at joint and repairing of damage to
building etc. for chilled water piping as per specifications with
Supproting Arrangement or paddestal on Terrace/ In shafts.

Note: The pipes of sizes 150mm & below shall be M.S. 'C'
class as per IS:1239 and Pipes size above 150 mm shall be
welded black steel pipe heavy class as per IS: 3589, from
min. 6.35 mm thick M.S. sheet for pipes up to 350 mm dia.
And from min. 7 mm thick MS sheet for Pipes of 400 mm
dia. and above.

Insulation specification and finishing material remains same


for the valves and drain pipes as per specifications.
150mm dia (75 mm thick insulation) with sand cement
a 250 RM 3,514.00 878,500.00
plaster in tunnel/under ground
b 16.3.6 150mm dia (75 mm thick insulation) 130 RM 2,779.00 361,270.00

c 16.3.7 125mm dia (50 mm thick insulation) 30 RM 2,330.00 69,900.00

d 16.3.8 100mm dia (50 mm thick insulation) 160 RM 1,981.00 316,960.00

e 16.3.9 80mm dia (50 mm thick insulation) 30 RM 1,555.00 46,650.00

f 16.3.10 65mm dia (50 mm thick insulation) 10 RM 1,343.00 13,430.00

Sign and Stamp of EPIL 40 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code

Providing and fixing in position the following Insulated


butterfly valves (Manual) with C I body SS disc, Nitrile rubber
2.4
seal & O ring PN-16 pressure rating for chilled/Hot water
circulation.Valves beyond 350mm dia shall be gear operated.
a 16.7.1.2 150 mm dia 2 No 6,625.00 13,250.00

b 16.11.3.7 100 mm dia (Motorized) 1 No 30,586.00 30,586.00

c 16.7.1.3 125mm dia No 5,780.00 0.00

d 16.7.1.4 100mm dia 28 No 5,330.0 149,240.00

e 16.7.1.5 80mm dia 2 No 3,719.0 7,438.00

f 16.7.1.6 65mm dia 4 No 3,351.0 13,404.00

g 16.7.1.7 50mm dia 12 No. 3,050.0 36,600.00

h 16.7.1.8 40mm dia 10 No. 2,686.00 26,860.00

Providing and fixing in position the following Insulated


2.5
ball valves.
a 32mm dia 34 No. 1,901.00 64,634.00

b 25mm dia 28 No. 1,786.00 50,008.00

Providing and fixing in position binder test points in the


2.6 60 No 864.00 51,840.00
chilled water pipelines.

Providing digital thermometers with probe suitable for binder


2.7 1 No 13,275.00 13,275.00
test point application.

Providing dial type pressure gauge with probe suitable for


2.8 1 No 13,275.00 13,275.00
binder test point application.

Providing and fixing in position the following Insulated


balancing valves C I body flanged construction with EPDM
2.9 coated disc with long pitch with protected out pipe insulation
& PN-16 pressure rating for chilled/Hot water circulation as
per the specifications.

a 16.7.2.2 150mm dia No 23,798.00 0.00


b 16.7.2.3 125mm dia No 18,608.00 0.00

c 16.7.2.4 100mm dia 7 No 11,945.0 83,615.00

d 16.7.2.5 80mm dia 1 No 7,395.0 7,395.00

e 16.7.2.6 65mm dia 2 No 7,101.0

f 16.7.2.7 50mm dia 6 No. 6,386.0 38,316.00

g 16.7.2.8 40mm dia 5 No. 3,175.0 15,875.00

h 32mm dia 11 No. 2,820.0 31,020.00

Sign and Stamp of EPIL 41 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Providing and fixing in position the following Insulated
check valves (Non Return ) with dual plat eof C.I. body SS
2.10 plates vulcanized NBR seal flanged end & PN-16 pressure
rating for chilled/hot water circulation as per the
specifications.
a 16.7.3.4 100mm dia 6 No 3,893.00 23,358.00

2.11 PICV/PIBC/High Rangeability 2 way Control valve


Supply, installation, testing and commissioning of complete
set of PICV/PIBC/ High rangeability control valve/ pressure
independent dynamic balancing cum control valve, kit
comprising of Two Way Control Valve of Brass/C.I body of
PN16 ratings, motorised modulating actuators with linear
stroke of minimum 15 mm,The actuator shall have shut off
capability of min. 4 bar rating. LCD display digital
controller(BMS compatible),three nos NTC sensors with
complete wiring within AHU room,one thermowell,one power
supply unit of 230Vac/24Vac.Tranparent IP55 Control box for
mounting Digital controller and power supply unit.The valve
size shall be suitable for pipe size/coil capacity

a 50mm dia No 63,264.00 0.00

b 40mm dia 6 No 50,034.00 300,204.00

c 32mm dia 5 No 22,464.00 112,320.00

d 25mm dia 11 No 15,552.00 171,072.00

Providing and fixing in position of approved make flow


2.12 switch complete with copper control wiring at chiller outlet of 7 No 2,880.00 20,160.00
each machine.

Providing and fixing in position the following Insulated


2.13 suction guide or suction diffusers/Flowstraighteners or y-
Strainer.
a 125mm dia 6 No 16,704.00 100,224.00

b 100 mm dia 4 No 14,400.00 57,600.00

2.14 Y- STRAINERS
Providing and fixing in position the following Insulated
Y-Strainers of ductile CI body flanged ends with SS stariner for
chilled/hot water circulation as per the specifications.

a 16.7.4.4 100mm dia RO No 6,918.00

b 16.7.4.5 80mm dia RO No 5,026.00

c 16.7.4.6 65mm dia No 4,434.00 0.00

d 16.7.4.7 50mm dia 6 No. 3,516.00 21,096.00

Sign and Stamp of EPIL 42 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
e 16.7.4.8 40mm dia 5 No. 2,478.00 12,390.00

f 32mm dia 11 No. 2,016.00 22,176.00

2.15 CONDENSATE DRAIN PIPE


Providing and fixing and in position the following PVC pipes
for condensate drain duly insulated with kinny foam & vapour
barrier duly secured with adhesive tape as per specification
,cut to required length and installed with all joints , including
the necessary fittings. (For all the AHU/FCU units upto the
main header in the shaft dor vertical risers)

a 65mm dia 20 RM 634.00 12,680.00

b 50mm dia 25 RM 484.00 12,100.00

c 40mm dia 30 RM 363.00 10,890.00

d 30mm dia 40 RM 288.00 11,520.00

e 25 mm dia 250 RM 207.00 51,750.00

2.16 AUTO AIR VENT


Supply, installation ,testing and commissioning of Auto Air
vents,at the specified locations in the chilled water piping ,
alongwith isolation ball valves, as per approved makes.

a Auto air vent with isolating ball valves (15 mm dia) 60 No. 1,440.00 86,400.00

2.17 FLEXIBLE PIPE CONNECTORS


Providing and fixing in position the following Flexible
connection on pipes with guide bolts.

a 100mm dia 18 No 7,488.00 134,784.00


Total Chilled water piping , valves and accessories
4,363,041.00
(Including Insulation)

3 CONDENSER WATER PIPING AND VALVES


3.1 Condenser water piping
Providing and fixing in position the following MS C
Heavy class Condenser water piping , cut to required length ,
and installed with welded joints , including all necessary
fittings such as elbows , tees , etc.and confirming to the
specifications as detailed in the relevant chapter in the
document.Pipes will be accepted in order of preference (
Factory fabricated / Fabricated out of 7mm thick plates duly
rolled in a workshop and welded : for pipes beyond 350mm
dia)
Note: The pipes of sizes 150mm & below shall be M.S. 'C'
class as per IS:1239 and Pipes size above 150 mm shall be
welded black steel pipe heavy class as per IS: 3589, from
min. 6.35 mm thick M.S. sheet for pipes up to 350 mm dia.
And from min. 7 mm thick MS sheet for Pipes of 400 mm
dia. and above.
a 16.10.2 250mm dia RM 3,524.00 0.00

Sign and Stamp of EPIL 43 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
b 16.10.3 200mm dia 60 RM 2,918.00 175,080.00
c 16.10.4 150mm dia 30 RM 1,983.00 59,490.00
d 16.10.6 100mm dia 10 RM 1,436.00 14,360.00
e 80mm dia 10 RM 1,022.00 10,220.00
f 50mm dia 10 RM 670.00 6,700.00

3.2 BUTTERFLY VALVES


Providing and fixing in position the following butterfly
valves with C I body SS disc, Nitrile rubber seal & O ring PN-
16 pressure rating.
a 16.11.1.2 150 mm dia 12 No. 5,914.00 70,968.00

b 16.11.1.4 100mm dia 3 No. 14,055.00


4,685.0
c 16.11.1.5 80mm dia 3 No. 9,906.00
3,302.0

d 16.11.1.7 50mm dia 3 No. 8,013.00


2,671.0
e 32mm dia 3 No. 2,284.0 6,852.00

3.3 BALANCING VALVES


Providing and fixing in position the following balancing
valves as per the specifications.
a 150mm dia 6 No 75,744.00 454,464.00

3.4 CHECK VALVES


Providing and fixing in position the following check
valves (Non Return ) with dual plat eof C.I. body SS plates
vulcanized NBR seal flanged end & PN-16 pressure rating as
per the specifications.
a 16.11.2.2 150 mm dia 3 No 5,772.00 17,316.00

3.5 FLEXIBLE PIPE CONNECTORS


Providing and fixing in position the following Flexible
connection on pipes with guide bolts.
a 150mm dia 12 No 8,640.00 103,680.00

3.6 Suction Guide


Providing and fixing in position the following suction
Guide/Suction diffusers/Flowstraighteners .
a 150mm dia 3 No 22,464.00 67,392.00

TOTAL (Condenser water Piping , valves and accessories) 1,018,496.00

4 AIR SIDE WORKS


4.1 Site Fabricated Duct - GI duct
Supply,Fabrication , Installation and testing of sheet metal
ducts (rectangular/round ducting complete with neoprene
rubber gaskets, elbows, splitter,vanes, hangers, supportsetc.)
in accordance with the approved shop drawings and
specifications , and shall also confirm to the BIS
specifications.The duct shall be fabricated at site for to suit
pieces.
a 16.12.2.1 0.63mm (24 gauge) GSS 2900 SqM 630.00 1,827,000.00

Sign and Stamp of EPIL 44 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
b 16.12.2.2 0.8 mm (22 gauge) GSS 300 SqM 751.00 225,300.00

c 16.12.2.3 1.0mm (20 gauge) GSS 80 SqM 983.00 78,640.00

d 16.12.2.4 1.25mm (18 gauge) GSS 50 SqM 1,104.00 55,200.00

4.2 Site Fabricated Duct - AL duct


Supply,Fabrication , Installation and testing of sheet metal
ducts in accordance with the approved shop floor drawings
and specifications , and shall also confirm to the BIS
specifications. The hardware shall be chrome plated or of
stainless steel.All lateral and transverse joints shall be sealed
with silicon based mastic sealant.

a Aluminum Sheet thickness - 1.00 mm 350 SqM 780.00 273,000.00

b Aluminum Sheet thickness - 1.25 mm 50 SqM 1,144.00 57,200.00

Supply, Fabrication, Installation and testing of Insulated Al.


Flexible ducts in accordance with the approved shop floor
4.3
drawings and specifications and shall also confirm to the BIS
specifications.
a 250 mm Dia. 110 RM 474.00 52,140.00

4.4 Grilles/Diffusers
Providing and fixing of Extruded aluminium supply and return
air grilles/diffusers/louvres with dampers, supply air plenum
etc. duly powder coated as per specifications and drawings.

a 16.15 Aluminium supply air grilles with damper. 16 Sqm. 7,132.00 114,112.00
b 16.16 Aluminium return air grilles without damper. 16 Sqm. 4,065.00 65,040.00
c 16.17 Aluminium supply air square diffuser with damper 6 Sqm. 8,686.00 52,116.00
Aluminium return/exhaust air square diffuser without
d 16.18 6 5,619.00 33,714.00
damper. Sqm.
Aluminium return/exhaust air Valve circular/squirell diffuser
e 18 Sqm. 4,901.00 88,218.00
without damper.
f Linear air grilles (150 MM wide) 50 RM 762.00 38,100.00
g Aluminium supply air collar damper 2.0 Sqm. 3,648.00 7,296.00
h AI Volume control dampers for ducts 15 Sqm. 4,901.00 73,515.00

4.5 Fresh Air/Exhaust Air Louvers


Supply, Installation, Testing and Commissioning of extruded
aluminium louvres with frame bird screeen , mounting
arrangement etc. as per specifications and drawings.

a Fresh Air/Exhaust Louvers 4.0 Sqm. 4,901.00 19,604.00

Sign and Stamp of EPIL 45 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
4.6 MOTORIZED FIRE AND SMOKE DAMPERS
Supply, Installation, Testing and commissioning of motorized
combination fire and smoke damper (spring return type) of
approved make of atleast 120 minute fire rating and as per
the specifications as detailed earlier in the relevant
sections.The fire damper shall be complete with electronic
temperature sensor and electrically operated actuator .The
fire dampers shall be located in the supply/return air ducts, at
all fire rated crossovers (shafts/walls etc.) The control panel
will be such located that the reset can be easily done These
combination smoke and fire dampers shall be interlocked
with the building management system for fire detection /
HVAC and shall trip/close in the event of fire / smoke in the
respective zone .

a 16.20.1 Bare Fire Dampers with 400 mm sleeve 5 SqM 7,103.00 35,515.00

b 16.20.2 Control panel actuator , including Electrical,spring type 20 No 6,604.00 132,080.00


actuator,remote indication of the fire damper position.
Interconnecting wiring for the fire alarm system with the AHU
c 1 Lot 65,340.00 65,340.00
and the smoke dampers.
Sealing the openings around the sleeve of the fire dampers
with approved fire sealant, as per the recommendations of
d 1 Lot 65,340.00 65,340.00
the manufacturer and specifications.

Sign and Stamp of EPIL 46 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
4.7 FACTORY FABRICATED DOUBLE SKIN INLINE PLENUMS
Supply,installation,testing and commissioning of factroy
fabricated Inline Double skin HEPA filter plenum sections of
aluminum construction,on extruded aluminum sections
WITH THERMAL BREAK PROFILE (SAME AS THE
a CONSTRUCTION FEATURES OF THE DOUBLE SKIN AHU) , 1 Nos. 5,990.00 5,990.00
suitable for housing 1 no.HEPA filters as described above for
,OT/ICU Scrub, exhaust as per specification with factory
fabricated access door and locking arrangement.

Supply,installation,testing and commissioning of factory


fabricated and insulated (with self adhesive XLPE / Nitrile
rubber foam) square (595 mm x 595 mm) laminar air flow
plenum with diffusion plates , volume control device and
4.8 openable perforated sheet with 50% free area,suitable to be No. 12,524.00 0.00
mounted in the standard grid ceiling all duly fabricated in
aluminum and powder coated, as per specifications, If at site
no Moduler OT Than its used.

Supply,installation,testing and commissioning of HEPA filters


of 610x610mm x 155 thick as per specifications and drawings
4.9
duly sealed with Epoxy and DOP tested.

HEPA filters as mentioned above for Up to 550 CFM handling


capacity for Terminals in Isolation 4 No. 9,257.00 37,028.00

Supply,installation,testing and commissioning of HEPA filters


4.10 of 610x610mm x 305/610 thick as per specifications and
drawings duly sealed with Epoxy and DOP tested.
HEPA filters as mentioned above for up to 2000 CFM
7 No. 7,079.00 49,553.00
handling capacity for Exh Blower in AHU

Supply,installation,testing and commissioning of Fine filters of


4.11 610x610mm x 305 thick or bag type as per specifications and
drawings duly sealed with Epoxy and DOP tested.
Fine filters as mentioned above for up to 1000 CFM handling
74 No. 4,901.00 362,674.00
capacity for supply Blower in AHU

Supply,Installation,Testing and commissioning of doble layer


4.12 canvas connection with 1/2 hr. fire rating as per 150 SqM 2,178.00 326,700.00
specification.

TOTAL (AIR SIDE WORKS) 4,140,415.00

Sign and Stamp of EPIL 47 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
5 MECHANICAL INSULATION
5.1 DUCT LINE ACOUSTIC TREATMENT
Supply, Installation, Testing and Commissioning of Acoustic
lining inside ducts using Non Fibrous fire retardant cross-
linked polyethylene foam of 30+/- 3 Kg/m3 density &
thickness of 15mm having porous surface on one side & a flat
surface on other side using Synthetic rubber based Adhesive
preferably Low VOC & high strength characteristic(Initial
portion of ducting and main plenum) as per specifications

25mm thick ecosound (FR-Open Cell Cross Linked


a Polyethylene) for AHU Room 150 SqM 1,653.00 247,950.00

15mm thick ecosound (FR-Open Cell Cross Linked


b 450 Sqm 1,345.00 605,250.00
Polyethylene)

5.2 DUCT LINE THERMAL INSULATION


Supplying , installation, testing & commissioning of external
thermal insulation on ducts with Closed Cell Cross Linked
Polyethylene shall be 27 ± 3 Kg/m3. The product shall have
temperature range of –40 oC to 105oC. Thermal Conductive
not exceeding 0.033 W/mK at an average Temperature of
23°C. The insulation material shall be fire rated for Class 1 as
per BS 476 Part 6 : 1989 for fire propagation test and for Class
0 as per BS 476 Part 7, 1987 for surface spread of flame test.
Water vapour permeability shall be not less than 0.024 per
inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ>7000: Water vapour
diffusion resistance).The Material shall have Fire Approval
from CBRI - Roorkie.
25 mm thick Closed Cell Cross Linked Polyethylene( XLPE)
a Foam with 2 layer Coating of 7mile cloth star bond insulation 350 SqM 850.00 297,500.00
material .(For Open Duct)
13 mm thick Closed Cell Cross Linked Polyethylene( XLPE)
b 400 SqM 523.00 209,200.00
Foam with Factory Aluminium sheet Laminated
9 mm thick Closed Cell Cross Linked Polyethylene( XLPE)
c 2200 SqM 392.00 862,400.00
Foam with Factory Aluminium sheet Laminated

TOTAL (Mechanical Insulation works) 2,222,300.00

Sign and Stamp of EPIL 48 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
6 ASSOCIATED ELECTRICAL WORKS

The rates for the distribution boards from the


Breakers and instruments shall also include the following :

A Wiring for light / Fan points with 1.5 sq. mm PVC insulated
copper conductor 1100 Volt grade stranded flexible FRLS
wires of approved make in 1.6 mm thick 25 mm dia MS
conduit including cost of providing & fixing saddles, hangers,
supports, cutting chases and filling chases for recessed
conduiting, and including the cost of providing and fixing a 6
amp 240 Volt Modular Plate type switches of approved
quality, colour, make and design with moulded cover plate
in zinc chromate passivated MS box and including the cost of
running 1.5 sq. mm PVC insulated copper earth wire for loop
earthing etc. complete

B TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with


adequate size of neutral link.
C All MCB’s shall be of minimum 10 KA breaking capacity.
D The breaking capacity of MCCB’s are mentioned panel wise.
All MCCB’s shall be with thermal magnetic microprocessor
releases as per BOQ
and following :
i. MCCB rating upto 250 Amps with thermal magnetic
releases.
ii. MCCB above 250 Amps with microprocessor releases.
E All MCB’s used for protection of resistive and lightly
inductive load shall be type “B” characteristic and
inductive (motor) load
shall be of type “C” characteristic.
F Degree of protection for following type of distribution panel
enclosure shall be as per IS:13947-1993.
i. IP 42 for indoor panels.
ii. IP 55 for ODU panel.
G All MCCB’s shall be provided with operating mechanism
for door interlock.
H All hinged door shall be earthed through 2.5 sq mm tinned
braided copper wire.
I Providing cable clamps / supports within distribution
boards cable alley.
J Current density of aluminium shall be 1sq mm for 1.0 Amps
for rated current of bus bars.
K Model, current capacity location and frame size of switchgear
shall be written inside of the panel doors with paint /
permanent marker as approved shop drawings / site
requirment.
L All meter shall be digital type.
M Current Transfomer shall be resin cast.
N All Panel Shall be BMS Compitable

6.1 Control Consol AHU/Fan Panel

Sign and Stamp of EPIL 49 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Supply, installation,testing and commissioning of floor
mounted desk type Remote Control with minic diagram
comproising of start/stop push buttons, status indicationi.e.
on/off/trip for 03 nos. Water-cooled screw chillers, 9 nos.
Condenser/Chilled/Hot water Pump sets,2 nos. cooling
Tower,22 nos. AHU , 4 Nos. Exh. Blower in AHU,4No. Liftwell 1 Nos. 141,520.00 141,520.00
Pressurization Fan,1 No. Hot Water Generator,1 Nos. Fan
Section and 10 No. Spares with inernal control wiring
commissioning and accesorries.

6.2 Plant/AHU/Fan Panel

Design, fabrication, assembling, wiring, supply, installation,


testing and commissioning of following LT panels fabricated
out of 14 guage CRCA sheet steel in cubical formationwith
reinforecment of suitable size angle iron and channel T iron
flats. All steel material used in the construction of panels shall
be powder coated. A solid busbar shall be provided at the
bottom of the panel with two connecting eyes for
termination. The boards shall be suitable for 415 volts, 50 Hz,
3 phase , 4 wire supply system. All the hardware used in the
fabrication of the panel shall be galvanized with zinc
passivation. The panel shall be compartmentalized to
accommodate one feeder in each compartment. A vertcal
cable alley of suitable width shall be provided to serve on or
two vertical feeder sections. Also the opening between the
busbar chamber and the feeder section shall be shrouded
with bakelite / hylam sheet with min.3 mm thickness.

The panel drawing shall be approved before taking up the


fabrication and compitable BMS if in future required.
In All panel Each starter should have remote control and
interlocking facilities including auto manual switch, NO/NC
contacts for control and must have auto manual operation
suitable to take signal from fire alarm panel for automatic
operation of fan in case of fire. All smoke /vent. fan panel
the starters shall have suitable facility to operate with fire
sensing control modules.
a HVAC Plant Room Panel-01 (Chiller/Pumps etc.)
Incoming
Incoming
1 no. 630 amp MDO ACB
0-500 volts voltmeter with SS with control fuses. (1set)
0-630 amp ammeter with SS and 800/5 CT's.(1set)
Phase indicating lights with control fuses.(1set)
Breaker ON/OFF/TRIP indicating lights.1set)
KW, Hz and power factor meter(2set)
Bus Bars
800 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
3 nos. 200 amp, MCCB, 25 KA with operating handles
for Chiller (Chiller with VFD)

Sign and Stamp of EPIL 50 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
1 nos. 400 amp, MCCB, 35 KA with operating handles
for HWG
3 nos. 20 amp, TP MCCB, 10 KA with operating handles
with DOL starter,OLP with SPPR etc. ) (2Working + 1
Standby) for primary Chilled/Hot water Pumps
3 nos. 32 amp, TP MCCB, 10 KA with operating handles
with VSD. ) (2Working + 1 Standby) for Secondary
Chilled/Hot water Pumps
3 nos. 32 amp, TP MCCB, 10 KA with operating handles
with Star delta starter,OLP with SPPR etc. ) (2Working +
1 Standby) for condenser water Pumps
2 nos. 20 amp, TP MCCB, 10 KA with operating handles
with DOL starter,OLP with SPPR etc. ) (2Working + 0
Standby) for cooling Towers
4 Nos, spare space
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 Nos. 317,200.00 317,200.00

b HVAC AHU Panel MCC-02


Incoming
1 no. 63 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
80 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
2 nos. 9-14 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
2 nos. 20-25 A,TP MPCB (with Star Delta starter ) incl. 1 no.
MPCB Spare
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 51,240.00 51,240.00

c HVAC AHU Panel MCC-03,08


Incoming
1 no. 32 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
40 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
2 nos. 6-10 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
2 nos. 4-6.3 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
1 nos. 6 A, MCB
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 2 No. 41,480.00 82,960.00

d HVAC AHU Panel MCC-06,10,12,13,14,20,21


Incoming/Outgoing
1 nos. 2.5-4 A,TP MPCB (with DOL starter )
Phase indicating lights with control fuses.

Sign and Stamp of EPIL 51 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Breaker ON/OFF/TRIP indicating lights.
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 7 No. 15,128.00 105,896.00

e HVAC AHU Panel MCC-07,11


Incoming
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
2 nos. 2.5-4 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
1 nos. 6 A, MCB
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 2 No. 37,576.00 75,152.00

f HVAC AHU Panel MCC-09


Incoming
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
2 nos. 4-6.3 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
1 nos. 6 A, MCB
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 37,576.00 37,576.00

g HVAC AHU Panel MCC-15,16


Incoming/Outgoing
1 nos. 4-6.3 A,TP MPCB (with DOL starter )
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 2 No. 17,080.00 34,160.00

h HVAC AHU Panel MCC-17


Incoming/Outgoing
1 nos. 9-14 A,TP MPCB (with DOL starter )
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 18,056.00 18,056.00

i HVAC AHU Panel MCC-18


Incoming
1 no. 20 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.

Sign and Stamp of EPIL 52 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
Bus Bars
32 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
2 nos. 2.5-4 A,TP MPCB (with VSD Space Provision)
1 nos. 6 A, MCB
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 37,576.00 37,576.00

j HVAC AHU Panel MCC-19


Incoming
1 no. 160 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
200 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
3 nos. 9-14 A,TP MPCB (with DOL starter ) incl. 1 no. MPCB
Spare
4 nos. 6-10 A,TP MPCB (with VSD Space Provision)
1 nos. 2.5-4 A,TP MPCB (with VSD Space Provision)
2 nos. 9-14 A,TP MPCB (with VSD Space Provision)
3 nos. 20 A, MCB
5 nos. 6 A, MCB
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 102,480.00 102,480.00

k HVAC AHU Panel MCC-22 (Residential Block)


Incoming
1 no. 32 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
40 amp TPN Aluminum Bus Bar with heat shrinkable
insulation colored sleeves.
Outgoings
1 nos. 4-6.3 A,TP MPCB (with DOL starter )
1 nos. 9-14 A,TP MPCB (with DOL starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings. 1 No. 41,480.00 41,480.00

6.3 CABLING (POWER )


Power Cabling and Earthing:

Supply, installation, testing & commisioning of Aluminum


conductor cables PVC sheathed, armoured cables of 1.1 KV
6.3.1
grade with termination glands and GI earthing, identification
tags, clamps and saddles etc.
a 3.5Cx185 Sqmm 100 Rmt 1,208.00 120,800.00
b 3.5Cx150 Sqmm 120 Rmt 988.00 118,560.00
c 3Cx16 Sqmm 20 Rmt 183.00 3,660.00
d 3Cx10 Sqmm 240 Rmt 173.00 41,520.00
e 3Cx 06 Sqmm 400 Rmt 138.00 55,200.00
f 3Cx04 Sqmm 800 Rmt 118.00 94,400.00

Sign and Stamp of EPIL 53 Sign and Stamp of Bidder


DSR-
Sr no. 2016 DESCRIPTION QTY UNIT RATE AMOUNT
Code
g 2Cx04 Sqmm (Cu Conductor) 225 Rmt 155.00 34,875.00
h 4Cx 06 Sqmm 150 Rmt 206.00 30,900.00

6.4 Control Cabling


Supply, installation, testing & commisioning of Copper
conductor , PVC insulated, PVC sheathed armoured
cable of 1.1 KV grade (Which is Interconnecting wiring
for the fire alarm system with the AHU and the smoke
dampers and AHU to Control Consol Panel).
a 8C x 1.5 Sqmm 2400 RM 193.00 463,200.00
b 3C x .5 Sqmm 80 RM 70.00 5,600.00
c 2C x .5 Sqmm 60 RM 62.00 3,720.00

Supply, installation, testing & commisioning of cable


termination of above cables with Al./copper lugs &
6.5
flameproof brass compression glands on both the ends with
inhibting compound etc. complete as required.
a 9.2.26 3.5Cx185 Sqmm 6 Set 1,290.00 7,740.00
b 9.2.23 3.5Cx150 Sqmm 8 Set 1,120.00 8,960.00
c 9.2.5 3Cx16 Sqmm 2 Set 663.00 1,326.00
d 9.1.7 3Cx10 Sqmm 16 Set 171.00 2,736.00
e 9.1.7 3Cx 06 Sqmm 26 Set 171.00 4,446.00
f 9.1.7 3Cx04 Sqmm 56 Set 171.00 9,576.00
g 9.1.1 2Cx04 Sqmm (Cu Conductor) 22 Set 157.00 3,454.00
h 9.1.32 4Cx 06 Sqmm 6 Set 203.00 1,218.00

Supplying and installing following size of perforated G.I. cable


trays, G.I. bends with perforation not more than 17.5%, joined
with connectors, suspended from the ceiling with suitable
6.6
suspenders including G.I. bolts & nuts, painting of suspenders
etc. complete as required.

a 4.6.1 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. 270 Rmt 436.00 117,720.00
b 4.6.2 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. 90 Rmt 504.00 45,360.00
c 4.6.3 225 mm. Width x 50mm. Depth x 1.6mm. Thickness. 80 Rmt 604.00 48,320.00
d 4.6.4 300 mm. Width x 50mm. Depth x 1.6mm. Thickness. 50 Rmt 703.00 35,150.00
e 4.6.6 450 mm. Width x 50mm. Depth x 1.6mm. Thickness. 50 Rmt 1,024.00 51,200.00

Providing and fixing following size of G.I. strip / G.I. wire on


surface or in recess for loop earthing alongwith the existing
6.7 surface/ recessed conduit/ submain wiring / on cable tray/ on
surface including G.I. clamps etc. complete as required.

6.7.1 5.9 6 SWG G.I. wire 225 Rmt 85.00 19,125.00


TOTAL (HVAC Electrical Works) 2,374,062.00
Total 30,243,129.00

Sign and Stamp of EPIL 54 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

MEP WORKS :-CSSD EQUIPMENTS BOQ

SR. NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

Horizontal Rectangular High Pressure High Vacuum


Double Door Sterilizer.The sterilizer will be
manufactured as per IS: No.3829 (part 1) 1978 with ISI
Mark. The unit will be designed for operating pressure
1 30 to 32 psi.And corresponding to a temperature of nos 1.00 2797043.00 2797043.00
1340c.The sterilizer chamber would be formed out of
SS 316.The sterilizer will be provided with 2 Nos.
perssure locking type hinged doors.

2 S.S 316 carriage suitable for rectangular sterilizer. nos 2.00 114134.00 228268.00
3 S.S 304 trolley suitable for Above carriage. nos 2.00 98912.00 197824.00
S.S control and packing table with drawer used for
seperation and packing of various sets of stermzed
4 nos 1.00 250,000 250000.00
sets of sterilzed goods for wads, clinics,operation
theatres etc.
S.s work table with two sink.The bench top is
5 fabricated out of 16 swg S.S 304 qlty.Ground and nos 1.00 114134.00 114134.00
polished with smooth surface and edge section.
Washer disinfector . Washer disinfector,single
door,suitable for cleaning and disinfection of surgical
6 nos 1.00 1133731.00 1133731.00
instrument, suction bottles, cleaning buckets etc.

Ultrasonic cleaner of overall size 530mmlx330mm


7 wx350mmH internal ions:505x300x200mm,output nos 1.00 540233.00 540233.00
frequency 35 khz.Capacity 30 litres.
8 Drying cabinet with single door nos 1.00 677196.00 677196.00
S.S table trolley with 2 shelves . IF for use in the sterile
9 goodsstore when batching sterile goods for delivery nos 3.00 114134.00 342402.00
and also for short interval transport.
10 Steel -single distilled nos 1.00 213053.00 213053.00
Stainless storage tank electric load 6 kw,capacity 120
11 nos 1.00 220000.00 220000.00
lites.
Spray Gunriser -: Spray gun riser with attachments is
used for cleaning syringes,catheters, endoscopes and
12 nos 1.00 146130.00 146130.00
variety of other instruments and articles used in sterile
services.

GRAND TOTAL 6860014.00

Sign and Stamp of EPIL 55 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

FURNITURE COST ESTIMATE


DESCRIPTIO
NO SPECIFICATION MODEL UNIT TOTAL RATE AMOUNT
N
Main material : particle board with the density of 680kg/m cube .
Surface : CPL (continuous pressure laminate) in 0.5 mm thickness. maestro main
Process: postforming in duck - nosed profile . Edging : 2mm pvc edging, table - 1800 Nos. 2 31950.00 63900.00
Black color. Color : dark cherry.
Table for Main desk : table top : 25mm MFC (Melamine Faced Chipboard), plus
1 Category 'A' 30 mm MDF (Medium Density Fiberboard) black pad. Modesty Panel: joining top -
Nos. 2 13871.00 27742.00
MS/DEAN 18mm MFC. Leg : 25mm MFC plus 30mm MDF right and left pad. 1050 x1200x750

Side return Desk: table top: 25mm MFC. Metal black spacers: diameter side unit -
Nos. 2 30548.00 61096.00
+4cm, length =10.4cm Pedestal leg : 25mm MFC. 1200x600x730
Pedestal : top panel : 25mm MFC, all other panels : 18mm MFC . Lock : bookcase -
Nos. 2 28790.00 57580.00
provided. Castor : provided handle : metal. 790x400x2200
Credenza : Top panel : 25 mm MFC , door panels: 18mm MFC, all other back unit -
Nos. 2 57564.00 115128.00
panels : 18 mm MFC, Handle : metal. 1400x470x760
Wardrobe: Top panel: 25mm MFC, bottom panel : 25 mm MFC . Wood
door panels: 18 mm MFC , glass Doors: 5mm, All other panels: 18 MFC, mobile pedestal -
Nos. 2 17613.00 35226.00
Handle : metal. Joining top : top panel : 25mm MFC, leg : Metal. 400 x 560 x560

Executive Desk of size -2200W x 1190D x 750H consisting of Top:36 mm Nos. 39 29838 1163682
thk.side Panel:44 mm thk.Modesty Panel:18 mm thk. Mobile Pedestal Numero Uno Nos. 39 22113 862407
Configuration-1 pencil drawer, + 1 Box drawer + 1 filling drawer. Main table-2200 Nos. 39 67321 2625519
Table for
Dimensions: 406W x 550D x 640H, Pedestal Top Panel:25mm thk Side Table-
Category 'B'
Drawer Fronts & Carcass: 18mm thk. side Return Unit with Pedestal of 1380X480X700
1 HOD/
Dimensions:1380W x 480D x 700H Top:36 mm thk. Pedestal: 1 Pencil Back Unit-
Proffessor
drawer +3 Box drawers Top Panel-25 mm thk Drawer Fronts & Carcass 2400X420X1200 Nos. 39 13120 511680
/Associate
:18 mm thk. Back Unit / Cablnet Dimensions - 2406W x 400D x 1215H Mobile Pedestal-
side Panels:18 mm yhk PLB Shutters: 18 thk. PLB Cabiret Top Panel: 25 400X550X 460
mm thk. PLB
Manufacturing as per design and placing in position, Modular
conference Table of height 740mm, having two seater modules of size
1370x650mm , single seater module of 730x 650mm and round end
module of radius 710mm. The top of the table shall be made of
38mm (18mm plain particle board +18mm pain particle board
skirting +1mm Backing DL +0.6mm post formed natural Veneer ) of
approved quality . The legs of the table shall be 38mm thk (18mm
plain particle board +18mm pain particle board skirting + postforned
Conference Dl of 0.6mm thk). The modesty panel of the tables shall be 600mm Senate per seat
3 Nos 1 8990 8990
table high made of 18mm thk plain board confomi9ng to is 3087.Legs and (16 seater)
modesty panels shall be finished by using black Asian Paint Lipping
at edges for both tops and legs shall be made from MDF board of
approved quailty . The top , legs and modesty panel shall be joined to
each other by using eccentric wheel system . Glide screws shall be
put at bottom of legs for level adjustment of +/-7mm and a steel rib
tubular stiffner of 19mm square section of 1.2mm thk shall run
through each module to give sturdlness to the top.

Reception
5
Desk
Reception
Desk
5a Custom Made Nos. 3 95625 286875
(2500x800x1
050)
Reception
Desk
5b Custom Made Nos. 3 159375 478125
(1500x800x1
050)
UNDERSTRUCTURE ASSEMBLY : the understructure is an assembly of
tubular frames made of M.S.E.R.W. oval tubes of 3.5cm x 1.5cm. X
18BG. Thk.held together with perforated M.S. shelf + threaded nuts +
m/c screws. The ends of tubular frames are fitted with rubber studs at
Tipoy / the top and the bottom . The top studs are fitted with PVC vacuum
Centre pads for mounting and gripping the glass top. the tubular frames are
6 Tables types- black powder coated . CENTRE-PIECE TOP : The centrepiece top is CPR 2E Nos 8 4078 32624
2 (550x 550 made from 0.95cm. thick Float glass with rounded corners of size 550W
x 450) x 550 D x 425 H. SHELF: it is a fabricated assembly made by 0.5cm. thk.
perforated M.S. sheet welded to M.S. sq. pipe 1.5cm. x 1.5cm. x 14 BG
thick with 0.3cm thick HR. steel plates on each side for fixing
understructure assembly . the shelf assembly is black powder coated.

Sign and Stamp of EPIL 56 Sign and Stamp of Bidder


DESCRIPTIO
NO SPECIFICATION MODEL UNIT TOTAL RATE AMOUNT
N
study Table of size 1200mm x 600mm x 740mm having having wood
laminate finish the table top / work surface : Made from 25mm thick
PLB with PVC lipping. Side panels: Made from 18mm thick PLT with PVC
7 Table (study) lipping . Modesty panel: Made from 18mm thick PLT with PVC lipping . work Nos 40 4077 163080
Neat wiring flow with cut -outs on both sides, freestanding pedestal
for adequate personal storage
1)seat/back assembly:the seat is made up of insert moulded polyurethane
foam upholstered with foam laminated mesh fabric.the insert moulded
foam is assembled over a load bearing plastic seat cover.the back is made
up of two piece injection moulded frame.the inner frame is upholstered
with mesh fabric and mounted on the main assembly.the back has
adjustable lumber support support for achiving comfortable seating
high posture.main assembly.sub assembly seating size=52.5cm width,51cm
backrest depth. sub assembly back size=48.5cm max width,62 cm ht. effective back
executive ht.from seat=57cm. 2)POLYURETHANE FOAM:the polyurethene foam for
8 leoma 9m02 nos 2 17617 35234
chairs with seat is moulded with density=75 ±4kg/m3 and hardness=34±4.
arm rest for 3)ARMRESETS(ADJUSTABLE): THE ARMREST TOP IS INJUSTION MOULDED
IN POLYURETHENE and mounted on the uinjuction moulded ht.adjustable
category A
type armrest.the armrest is adjustable upto 4.5cm in three steps and with
adjustable armtop out of dim=62 to 65 cm arm top centre to centre
dim=53 to 56 cm. 4) front pivot sinchro mechanism.the mechanism is
design with following features-3600 revolving type-single point control-
fron pivot for till with feet resting on ground ensuring more comfert-tilt
tention adjestment-3 positions locking with anti shock
SETBACK ASSEMBLY-the seat/back are made up of 1.2 cm thk.hot
pressed plywood up holsted with fabricant moulded polyurethene
foam together with moulded seat and backcovers.the back foam is
design with conured lumber support for extra comfort.(high backsize
50cm widthx 72cm ht.seat size 50cm wx46cm (D) polyurethene foam-
the polyurethene foam is moulded with density=45+/- 2kg m3 and
high ha4rdness=2+/-2 on hampden machine at 25% compression. seat /back
backrest covers the seat covers with injuction moulded with in black co-polymer
executive polypropilene and back cover is vaccume formed from ABS sheets
10 regency 7001D Nos. 51 16336 833136
chairs with armrests.the one peace armrests made of black integral skin
arm rest for polyurethene with 50 to 70 shore (A) hardness and reinforced with MS
category B insert. the armrest are scretch and weather resistant.the armrest are
fitted to the seat the armrest connecting strip assembly made of 0.5 cm
thk.HR steelb CENTER PIVOT MECHANISM the centre pivot mechanism
is design with following features-3600 revolving types 17 degree max.
tilt on pivot at centre.tilt tention upright locking telescopic below
assembly-the below is three piece telescopic type and fitted with 5 no's
twin wheel casters(casters wheel dia.5cm) the padistal covered with a

Sign and Stamp of EPIL 57 Sign and Stamp of Bidder


DESCRIPTIO
NO SPECIFICATION MODEL UNIT TOTAL RATE AMOUNT
N
SEAT / BACK ASSEMBLY: The seat / back are made up of 1.2 cm thick
hot pressed plywood, upholstered with fabric and moulded
polyurethane foam together with moulded seat and back covers, the
back foam is designed with contoured lumbar support for extra
comfort . (MEDIUM BACK) SIZE :50.0cm. (W) x 49.0cm. (H) SEAT.SIZE:
Medium 50.0cm. (W) x 46.0cm. (D) . POLYURETHANE FOAM: The polyurethane
back visitors foam is mouulded with density = 45 +/-2 kg/ m3 and Hardness =
chairs for 20+/-2 on Hampden machine at 25% compression .SEAT / BACK
11 category B COVERS: the seat and back covers are injection moulded in black co- Rergency 7003D Nos. 4 8954 35816
H.O.D. / polymer polypropylene ARMRESTS: The one - piece armrests made of
P.A./ back integral skin polyurethane with 50-70 shore ;A' Hardness and
prof.Room reinforced with M.S. insert, the armrest are scratch and weather
resistant . The armrests are fitted to the seat with seat/ armrest
connecting strip assembly made of 0.5cm . thk . HR steel. TUBULAR
FRAME : The tubular frame is centilever type & made of Dia 2.54cm.
(1") x 14 BG M.S. E.R.W.tube and black powder coated

SEAT / BACK ASSEMBLY: The seat / back are made up of .2 cm thick


hot pressed plywood, upholstered with fabric and moulded
polyurethane foam together with moulded seat and back covers, the
back foam is designed with contoured lumbar support for extra
comfort . (MEDIUM BACK) SIZE :50.0cm. (W) x 49.0cm. (H) SEAT.SIZE:
50.0cm. (W) x 46.0cm. (D) . POLYURETHANE FOAM: The polyurethane
Medium foam is mouulded with density = 45 +/-2 kg/ m3 and Hardness =
back rest 20+/-2 on Hampden machine at 25% compression .SEAT / BACK
12 chairs with COVERS: the seat covers are injection moulded in black co- polymer Rergency 7002D Nos 120 15323 1838760
arm rest for polypropylene and back coveris vacuum formed from ABC sheets
category 'C' ARMRESTS: The one - piece armrests made of back integral skin
polyurethane with 50-70 shore ;A' Hardness and reinforced with M.S.
insert, the armrest are scratch and weather resistant . The armrests are
fitted to the seat with seat/ armrest connecting strip assembly made of
0.5cm . thk . HR steel. CENTRE PIVOT MECHANISM The center pivot
mechanism is designed with the following features : 3600 revolving
type . 17 maxmimum till on pivot at center . Tilt tension adjustment.
upright locking .TELESCOPIC BELLOW ASSEMBLY : The bellow is 3 piece
Low back SEAT / BACK ASSEMBLY: The seat / back are made up of .2 cm thick
Visitcrs hot pressed plywood, upholstered with fabric and moulded
chairs for polyurethane foam with PVC lipping all around . , the back foam is
category D designed with contoured lumbar support for extra comfort .BLACK
Asst.prof / SIZE : 49.0CM . (w) X47.0cm (H) SEAT SIZE:49.0cm. (w) X44.0cm. (D) .
Tutor / Tech POLYURETHANE FOAM: The polyurethane foam is mouulded with
14 / Pre. Tech / density = 45 +/-2 kg/ m3 and Hardness = 20+/-2 on Hampden Premier-7112R Nos 30 4553 136590
Lab asst. machine at 25% compression. TUBULAR FRAME: The tubular frame is
/adm off. cantilever type & made of Dia. 2.54cm. (1")x 14 BG M.S.E.R.W. tube
Staff /prep and black powder coated.
00m /Record
/ seecurity

Sign and Stamp of EPIL 58 Sign and Stamp of Bidder


DESCRIPTIO
NO SPECIFICATION MODEL UNIT TOTAL RATE AMOUNT
N
Doctor /Staff 4Dr locker units of height 1830 mm with looking mechanism: 10 Lever
/Nurse cam lock with lock lever and option of hasp arrangement Material:
/Orderly CRCA 0.6cm Thickness . Construction : Rigid knockdown construction.
Change Shelf Uniformly Distributed Load Capacity per each shelf level is 35
Room. kg maximum. Finish: Epoxy polyester powder coated to the thickness 4 Door lockers
15 Ladies / of 50 microns (+/-10) .Handle / Label holder .Aesthetically appealing per Units with Nos 10 12953 129530
Gents snap fit ABS plastic handle . plastic label holder for identification. Locks
lockers Ventilation: Attractive punched pattern for ventilation
(380x457x18
30)

2 SEATER LOUNGE SOFA of size :W 1130 mmx D 700 mm x H 785 mm,


Seat ht. 435. SIDE FRAME ASSEMBLY : The side frame assembly is fitted
to the two ends of the connecting beam assembly to form the leg-cum-
armrest assembly . It is made of a MS. E.R.W. tube dia 3.81 cm. x 14 BG.
thk. and black power coated .The ends are fitted with ABS moulded end
caps. TIE MEMBER : it is the connecting beam assy. which holds the two
side frame to each other. 2 nos. tie members are used to connect the
side frames. The tie member is made of MS. E.R.W. tube dia 3.81 x14
BG. thk. and black power coated.The seat /back assemblies are
mounted on one of the tie- member which has 5cm. x5.5cm longx .5
2 Seater Sofa cm.thk. MS. std. angles welded to mount the seat and back.SEATREST
(Uphoistere ASSEMBLY : the seat rest assembly consists of a fabricated inner-frame
16 L42 NOS. 10 14015 140150
d /high assembly insitu moulded with Polyurethane foam having density= 45+/-
Cousioned ) 2 kg./ch3. the hardness of the P.U. foam 23 -27 kgs. on hampden m/c.
for 25% compression of the foam. the complete moulded seat rest
assembly is covered with a replaceable fabric upholstery cover.SEAT
SIZE: 52 (W)X 50CM. (D)X6CM (T) BACKREST ASSEMBLY : THE BACK
REST ASSEMBLY IS FLEXING TYPE AND CONSISTS OF A fabricated inner
frame assembly insitu -moulded with polyurethane foam having
density =45+/- 2 kg/cm3. The hardness of the P.U. foam =16-20 kgs. on
Hampden m/c for 25% compression of the foam .The complete
moulded backrest assembly is covered with a replaceable fabric
upholstery cover.BACK SIZE : 52 (W) 59(H) 6 (T) ADJ.glide is injection
moulded in black nylon & fitted to the front end of side frame assembly
STORAGE
UNIT (SIZE
IN MM =
18 CUSTOM MADE Nos 45 12559.00 565155.00
1200 X 450 X
750 )WITH
PF TOP
Metal Perforated 3 seater Bench having of size: W 1680 mm X D
570MM X H 850 mm Seat hight 460 mm, SEAT BACK FRAME ASSEMBLY:
The seat and back are made of 18BG thick CR steel perforated sheets
which are welded to a seat/back frame assembly made of Dia. 1.9 cm
(3/4") X 16BG thick MS ERW tube connection beam. SEAT SIZE 39.0cm
(W) X 41.5cm. (D) (Approx,) BACK SIZE: 39.0cm. (W) X 21.5cm. (H)
(Approx.). ARMREST : it is made up of oblong tube of size 35 mm X
15mm X 1.6 Thk. & Dia. 15mm bright bar wekded to seat & back frame
assembly. CONNECTING BEAM ASSEMBLE: it is a U- shaped fabricated
Metal
assembly made of Dia. 3.81cm. (1 1/2") X 14 BG. MS ERW twin tubes.
Perforated
The connecting tubes are welded together with MS base plates made of
20 Chair on BPMXX3 Nos. 135 8542.00 1153170.00
12BG thick CR. Steel and mounting plate made of 0.5cm thick HR Steel
Bench-
Threaded inserts are provided on both ends of each connection tube or
3Seater
fixing leg assembly on each side. The connecion beam assembly is
power coated. LEG ASSEMBLY: it is a 2-piece fabricated to form a box
section made of 16BG thk. CR steel. Threaded nuts are welded to the
box section for fixing adjustable glide screws. The leg assembly is
powder coated. ADJUSTABLE GLIDE: The adjustable glide is injection
molded is black Nyion 6 and is used for level adjustment of the beam
seation on uneven floor surface. it is fitted to the leg assembly.

Sign and Stamp of EPIL 59 Sign and Stamp of Bidder


DESCRIPTIO
NO SPECIFICATION MODEL UNIT TOTAL RATE AMOUNT
N
Metal Perforated 2 seater Bench having of size: W 1110 mm X D
570mmX H 850 mm Seat hight 460 mm, SEAT BACK FRAME ASSEMBLY:
The seat and back are made of 18BG thick CR steel perforated sheets
which are welded to a seat/back frame assembly made of Dia. 1.9 cm
(3/4") X 16BG thick MS ERW tube connection beam. SEAT SIZE 39.0cm
(W) X 41.5cm. (D) (Approx,) BACK SIZE: 39.0cm. (W) X 21.5cm. (H)
(Approx.). ARMREST : it is made up of oblong tube of size 35 mm X
15mm X 1.6 Thk. & Dia. 15mm bright bar wekded to seat & back frame
assembly. CONNECTING BEAM ASSEMBLE: it is a U- shaped fabricated
Metal
assembly made of Dia. 3.81cm. (1 1/2") X 14 BG. MS ERW twin tubes.
Perforated
The connecting tubes are welded together with MS base plates made of
21 Chair on BPMXX2 Nos. 20 6718.00 134360.00
12BG thick CR. Steel and mounting plate made of 0.5cm thick HR Steel
Bench- 2
Threaded inserts are provided on both ends of each connection tube or
Seater
fixing leg assembly on each side. The connecion beam assembly is
power coated. LEG ASSEMBLY: it is a 2-piece fabricated to form a box
section made of 16BG thk. CR steel. Threaded nuts are welded to the
box section for fixing adjustable glide screws. The leg assembly is
powder coated. ADJUSTABLE GLIDE: The adjustable glide is injection
molded is black Nyion 6 and is used for level adjustment of the beam
seation on uneven floor surface. it is fitted to the leg assembly.

chair having width 52.0 mm, depth 54.5mm, height 80.5mm and seat
Chairs for
22 height 43.0 mm. seat & back shell is injected moulded in propylene. MPC4 Nos. 50 2950.00 147500.00
canteen
Tubular frame is in 19mm dia. Stainles steel tube.
understructure: the understructure is foldable and stackable, made
with combination of aluminium and plastic. Centre column is of
serracted aluminium extrusion of diameter 70mm, which is anodized.
Base is made in 2 pieces of die cast aluminium with buffed finish. it is
bolted together with the centre column and top flange. MDF top with
PU coating (both profiles): size 800mmx800x25mm thick made of
25mm thick MDF , painted in yellow, red, orange, wine, beige PU
Table for
coating on a sealer coat. PU coating done on both . PU coating on sealer
canteen (4 café pod -
coat. PU coating done on both top and bottom surfaces. PU coating has
23 seater) (size rubber wood Nos. 13 13505.00 175565.00
hardness of 3H. Top is fitted to the understructure with no. bx16 pholip
in mm = top
head screw rubber wood top with PU coating (both profiles) size :
900x900)
800mm x18mm thick made of 18mm thick rubber wood. top is made of
2 finishes: wenge and natural. stainless steel top size : 800mm x
800mm x 1.2 mm thick 24mm thick - top assembly top made from 1.2
mm thick SS- 304brushed steel finish sheet welded stiffner assembly
made from 0.6 mm thick SS-304 sheet glued with top with special glue.

TOTAL COST FOR FURNITURE WORKS 11,818,620.00

Sign and Stamp of EPIL 60 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

MEP WORKS :-INDIAN OPERATION THEATRE - BOQ


Rate Amount
Sr.
Code Description Quantity Unit
No. MR

Supply, Installation, Testing and


commissioning etc as required for the
follwing items required for the Operation
Theatre

Stainless Steel 304 Grade with1.5mm


Pre Fabricated Modular Operation
1 MR Theatre.Wall Panel backed with 12mm 3.00 Set 997800.00 2993400.00
thick. gypsum with proper supports.

Stainless Steel 304 Grade with 1.5mm


Pre Fabricated Modular Operation
2 MR Theatre.Ceiling Panel backed with 12mm 3.00 Set 424804.00 1274412.00
thk. gypsum with proper supports.

Filling of Joints ,Cavity and imported


Antuibacterial paint.Filling of all joints &
cavities with epoxy filler, sanded flush for
3 MR seamless finish with one primer and three 3.00 Lot 392130.00 1176390.00
coats of antibacterial & antifungal paint .
That is equivalent to a dry film thickness of
300 microns .
Hermatically Sealed automatic sliding
door. (Patient entry).Automatically
Operated hermatically sealed Sliding
4 MR Doors 1500mm x 2100mm (WXH) with glass 3.00 Set 920450.00 2761350.00
vision window of 300mm x 300mm (WXH)
along with all accessories.

Hermatically Sealed automatic sliding


door. (Doctors entry).Automatically
Operated hermatically sealed Sliding
5 MR Doors 1000mm x 2100mm (WxH) with glass 3.00 Set 842000.00 2526000.00
vision window of 300mm x 300mm
(WxH) along with all accessories.

Sign and Stamp of EPIL 61 Sign and Stamp of Bidder


Rate Amount
Sr.
Code Description Quantity Unit
No. MR

Laminar airflow.Laminar Planair Ceiling


system with unidirectional airflow with "S"
class Hepa filter with an efficiency 99.97%
down to 0.3 micron. The holding structure
& top plenum are made up of Aluminium
Sheet with a thickness of 1.6mm. It should
be sealed with gasket conforming to DIN
4799 standards for the air distribution
system. 2 layer diffuser with monofilament
6 MR precision woven polyester of uniform 3.00 No. 398000.00 1194000.00
porosity with an open area of sufficient
resistance to create laminar from diffusers
face and inetgral lighting provides an
illumination level in excess of 15000 Lux in
operating area and 10000 Lux other with
flickerless digitally controlled stepless
dimming down to 5%.

Medical Gas pipeline inside Operation


Theatre .Medical Gas pipeline system
7 MR 3.00 Set 398000.00 1194000.00
inside OT for Medical gases including all
fittings and fixtures.
Electrical wiring.Electrical wiring within the
OT Area, conduit pipes and electrical switch
8 MR & Socket with Electrical Distribution board 3.00 Lot 60000.00 180000.00
for Operating room with MCB's and Relay
cards.
Peripheral lights.Recess mounted IP 54
protocol, non-hygroscopic Peripheral
Lights for clean room application. Each light
9 MR 18.00 Set 19200.00 345600.00
set having 2nos of 36 watt flouracent
lamps with digitaly controlled dimmable
ballast.
10 MR Scrub 3 - bay. 3.00 No. 159680.00 479040.00
11 MR Writing board.Magnetic writing Board. 3.00 No. 13200.00 39600.00
X-ray view box.Two Plate X-Ray viewing
12 MR screen with flicker free dimming range from 3.00 No. 39150.00 117450.00
3 to 100% with complete accesories.
Membrane type Operating room Control
panel.Membrane type Operation
Theatre Control Panel (6 service Tiles)
mounted. Flushed in the theatre wall with
complete distribution board with all
accessories. Following are the
controls/display available:-
13 MR 3.00 Set 393610.00 1180830.00
* 1 no Day Time Digital Clock.
* 1 no Elapsed Time Digital Clock.
* 1 no Hands Free Telephone.
* Peripheral Light Control
* Medical Gas Alarm for 4 gases.
*Temperature & Humidity Indicator .
* Alaram for Vacum.

Sign and Stamp of EPIL 62 Sign and Stamp of Bidder


Rate Amount
Sr.
Code Description Quantity Unit
No. MR

Dirty Hatch box.2 door dirty hatch box made


up of Stainless steel grade 304. One door will
be opened at one time , indicator on both
sides.The hatch will be designed in such a
14 MR way that only one door will be opened at 3.00 No. 298800.00 896400.00
one time. The UV light will glow when both
the doors are in closed position.

15 MR Ceiling mounted Operating room light. 3.00 Set 1202300.00 3606900.00


Pendants.Pendent with weight carrying
capacity of 100Kg. The pendant should have
16 MR electrical sockets, one monitor shelf and gas 6.00 Set 395000.00 2370000.00
outlets for medical gas supply.
Pressure relief damper.Pressure Relief
17 MR Damper. Made up of 304 graded stainless 3.00 Set 49648.00 148944.00
steel blades with all accessories.
Anti - static flooring.2mm thick Anti static,
conductive dissipative flooring tile laid on
18 MR a semi conductive adhesive base resistant to 3.00 Lot 320130.00 960390.00
mechanical stress and dynamic load and
washable.

TOTAL 23444706.00

Sign and Stamp of EPIL 63 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

MEP WORKS :-TRACK SYSTEM - BOQ

S.NO. FURNITURE ITEM QUANTITY PRICE AMOUNT

TRACK SYSTEM ICU, CCU, RECOVERY,


1 COMPLETE WITH TRIAGE, , AND WARDS 200 24000 4800000
CURTAINS BEDS
IV TREE SYSTEM, 5
POINT HANGER WITH
2 6' TRACK AND ALL FOR BEDS 200 31200 6240000
ACCESSORIES WITH 2
IV TRACKS PER BED
TOTAL 11,040,000.00

Sign and Stamp of EPIL 64 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

MEP WORKS ABSTRACT SHEET :-KITCHEN EQUIPMENT - BOQ


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR

MILK BOILER /TEA BOILER


Cap.50Ltrs. S.S.Sheet insulated body with
triple jacket. The water jacket will be
fitted with 2 Kw heating element. Milk
outlet, water level indicator & draw
1 MR 1 No. 78500.00 78500.00
off valve at the bottom & water
tank. Phillips element, Elcon
thermostat, GVC rotary switch, LED
indicator for Power, 4mm thickness 3
core wire Rajdoot/ Plaza make

MICROWAVE OVEN
2 MR Cap.20-30Ltrs. 1 No. 29800.00 29800.00
IFB-MAKE - SC-2
PICK UP COUNTER WITH OVERSHELF
Size 1800X600X850 + 300
Top
3 sides, under & over shelf of s.s.sheet,
on m.s.angle & s.s.tubular legs frame
work. The counter will have 3 sides fully
covered, operator side open. With one
3 MR 2 No. 90000.00 180000.00
under shelf. One over shelf 300mm wide
& running along the full length of counter
u type heating element of 1 Kw is placed
under the one head
shelf to keep the dishes warm provided
with toggle switch also connected with
4 mm 3 core wire.

WORK TABLE FOR SUPPORT OF TWO


BURNER RANGE
Size 1350x600x850mm
4 MR Top & undershelf of s.s.sheet on 1 No. 39000.00 39000.00
m.s.anlge frame work & s.s.tubular legs,
with adjustable feet. Top to have sound
deadning material lining as required.
TWO BURNER COOKING RANGE
App. Size 1200X600X850mm
Frame work of m.s.anlge duly painted,
mounted on s.steel tubular legs with
5 MR adjustable feet. Top & sides & under 1 No. 35000.00 35000.00
shelf of s.s.sheet. The range will be
complete with 2nos. Hy-pressure gas
burners with individual control valves.
Cast iron pan support

Sign and Stamp of EPIL 65 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR

EXHAUST HOOD (Without Ducting,


Fixing & Extraction fan) FOR TWO
BURNER RANGE
Size 1950x750x600mm
Made of s.steel sheet, 20G thick duly
6 MR 1 No. 75000.00 75000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.

JUICER (table top model)


Cast Aluminum/CI body, duly
polished / painted, with worm &
7 MR 1 No. 58000.00 58000.00
perforated insert. Top feeding tray.
Worm easily cleanable fitted with 1/2HP
elect. motor.
CONVEYOR TOASTER
App. Cap. 100-125 Toasts/hr.
S.S.Sheet body, having s.s.sheet conveyor
belt. App.225mm wide. The unit will have
8 MR 1 No. 98000.00 98000.00
heating elements on top & lower
portion of conveyor belt with variable
heat & speed control switch. (MADE IN
ITALY)
WORK TABLE WITH SINK
Size 1950x600x850+150
Top & Sink bowl of s.s.sheet, on s.s.anlge
9 MR & s.s.tubular frame work with cross 1 No. 73500.00 73500.00
bracing at lower portion. Sink bowl will
be integrally welded with top & grinded
smooth. Sink bowl size 450x450x250mm.

FOUR DOOR REFRIGERATOR


App. Size 1200x675x2000mm
Double walled, insulated 'PUF' body
made of 0.8mm thick s.s.sheet. Inside
10 MR chamber to have 4nos. S.s.wire shelves 2 No. 155000.00 310000.00
on adjustable channel. The unit will
have 4 doors with magnatic rubber
gascuts & locking provision. The
condensing unit, consisting of 'Kirlos

Sign and Stamp of EPIL 66 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR
WORK TABLE
Size 1500X600X850mm
Top & undershelf of s.s.sheet on
11 MR 1 No. 48000.00 48000.00
m.s.anlge frame work & s.s.tubular legs,
with adjustable feet. Top to have sound
deadning material lining as required.

THREE BURNER COOKING RANGE


SIZE 1800X600X850
Structure made of m.s. angle
of size 38x38x5mm, duly rust proof
12 MR painted. Top of 16Swg thick s.s.sheet. 1 No. 74000.00 74000.00
All four side covered up to height of app.
10” by 20Swg stainless steel sheet.
Bottom stainless steel stripes sheets
complete with gas burners, valves p

EXHAUST HOOD (Without Ducting,


Fixing & Extraction fan) for
THREE burner RANGE
Size 1950x750x600mm
Made of s.steel sheet, 20G thick duly
13 MR 1 No. 75000.00 75000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.
LOW HT. TABLE for supporting low
height burner
Size 750x750x600mm
14 MR Specification same as that of work 2 Nos. 25000.00 50000.00
table but the table will be without
undershelf & will have cross bracing
support at lower portion.

LOW HT. BURNER


Size 750x750x600mm
Specification same as that of cooking
15 MR 2 Nos. 27000.00 54000.00
range but the unit will be without
undershelf, but will only have cross
bracing support at lower portion.

Sign and Stamp of EPIL 67 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR
EXHAUST HOOD (Without Ducting,
Fixing & Extraction fan) for
LOW HEIGHT BURNER range
Size 1650x750x600mm
Made of s.steel sheet, 20G thick duly
16 MR 2 Nos. 66000.00 132000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.

THREE BURNER COOKING RANGE


O/S 1800X600X850
Structure made of m.s. angle
of size 38x38x5mm, duly rust proof
17 MR painted. Top of 16Swg thick s.s.sheet. 1 No. 74000.00 74000.00
All four side covered up to height of app.
10” by 20Swg stainless steel sheet.
Bottom stainless steel stripes sheets
complete with gas burners, valves p

WORK TABLE for support of 03 burner


cooking range
Size 1500X600X850mm
18 MR Top & undershelf of s.s.sheet on 1 No. 48000.00 48000.00
m.s.anlge frame work & s.s.tubular legs,
with adjustable feet. Top to have sound
deadning material lining as required.

EXHAUST HOOD (Without Ducting,


Fixing & Extraction fan) for
THREE BURNER RANGE
Size 1950x750x600mm
Made of s.steel sheet, 20G thick duly
19 MR 1 No. 75000.00 75000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.
BULK COOKER/boiler TILTING TYPE
Cap.160Ltrs.
Specification same as Sno.13 but the
frying pan will be Of rectangular shaped
20 MR 1 No. 186000.00 186000.00
with 12”depth & a pouring lip & the unit
will be fitted with v type high pressure
gas burner with control valve & pilot
lamp.

Sign and Stamp of EPIL 68 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR
BULK FRYER TILTING TYPE
Cap.100Ltrs.
Triple jacketed body of stainless steel
sheet, Inner most jacketed of 16g thick
21 MR with 12g thick dish ended bottom, 1 No. 185000.00 185000.00
second wall for air gap of 18g stainless
steel sheet & outer insulation jacket also
of 18g stainless steel sheet. The unit will
have counter
EXHAUST HOOD (Without Ducting,
Fixing & Extraction fan) for
BULK COOKER & FRYER
Size 1650x750x600mm
Made of s.steel sheet, 20G thick duly
22 MR 2 Nos. 66000.00 132000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.
WET GRINDER
Cap.15ltrs (1.0HP)
Stainless steel sheet constd. Body with
s.s.sheet constd. Revolving drum,
23 MR 1 No. 65000.00 65000.00
cromium plated pillar support on
m.s.angle frame work fitted with
electric motor gear box & grinding stones
& coconut scraper.

DOUGH KNEADING MACHINE


(CROMPTON MOTOR 2.0 HP)
App. Cap of Bowl 25Ltrs.
S.S.Mixing bowl, with s.s.rod/strip mixing
24 MR 1 No. 90000.00 90000.00
arm, mounted on steel tubular & sheet
frame work duly painted. Complete
with 1.0HP Elect. Motor with control
switch.

POTATO PEELER
Cap.15Kg./chrgs. (CROMPTON MOTOR
1.0 HP)
16 gauge Stainless steel sheet peeling
drum, lined inside with Abrasive
25 MR 1 No. 78000.00 78000.00
material, stainless steel /cast iron
rotating peeling disc. Top of the drum will
have a potato inlet door, waste Inlet
provision peeled potato discharge door &
waste water Outlet pipe

Sign and Stamp of EPIL 69 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR

PULVeRISER (Std.) (CROMPTON MOTOR


1.0 HP)
Stainless steel sheet body,20g thick. the
unit will have A top feeding tray & a
26 MR housing of stainless steel casting With 1 No. 69200.00 69200.00
grinding plates & 3 type of meshes for
variable type Of grinding requirements.
The unit will be fitted with 1.0 hp single
Phase electric

WORK TABLE support of pulverisor


Size 1500X600X850mm
Top & undershelf of s.s.sheet on
27 MR 1 No. 48000.00 48000.00
m.s.anlge frame work & s.s.tubular legs,
with adjustable feet. Top to have sound
deadning material lining as required.

WORK TABLE WITH SINK for vegetable


washing
Size 1950x600x850+150
Top & Sink bowl of s.s.sheet, on s.s.anlge
28 MR 1 No. 73500.00 73500.00
& s.s.tubular frame work with cross
bracing at lower portion. Sink bowl will
be integrally welded with top & grinded
smooth. Sink bowl size 450x450x250mm.

CHOPPING BOARD for manual


vegetable cutting
size:- 1200X600X850mm
29 MR Frame work made of s.s.anlge top 1 No. 78000.00 78000.00
will have P.P./Nylon Board for
chopping 700x700x100mm chopping
board.

Sign and Stamp of EPIL 70 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR

VEGETABLE CUTTING MACHINE


Aluminium casted body with ½ hp
electric motor safety switch & double
feed pusher for round flat & vertical
30 MR 1 No. 98500.00 98500.00
shaped food items etc., the unit will be
Table top model with easy to clean
provision. Provided with 4 no cutting
discs for slicing grating Dicing

CHAPPATI COLLECTION TABLE


Size 1500X600X800
Top tray of 16G s.s.sheet, tray will have
31 MR App.100mm ht. collor all around, 1 No. 48000.00 48000.00
mounted on s.s.tubular legs with
adjustable feet & one s.s.sheet
undershelf.
CHAPPATI ROLLING TABLE
Size 2100x650x850mm
Top & undershelf of s.s.sheet on
m.s.anlge frame work & s.s.tubular legs,
32 MR with adjustable feet. Top to have sound 1 No. 79500.00 79500.00
deadning material lining as required.
THREE SIDE CROSS BRACING MADE
OF S.S. PIPE 1" DIA FOR UNDERNEATH
STORAGE.
CHAPPATI PLATE CUM PUFFER
Size 1800x650x850mm
Frame work of m.s.anlge, mounted on
s.s.tubular legs frame work. All sides
33 MR pannels & undershelf of s.s.sheet, top 1 No. 98000.00 98000.00
plate 10mm thick mild steel with cast
iron puffing grills for puffing of
chappaties. Complete with 'V' shape
LPG burners with individual cont

EXHAUST HOOD (Without Ducting,


Fixing
& Extraction fan) for chapatti plate
Size 1950x750x600mm
Made of s.steel sheet, 20G thick duly
34 MR 1 No. 75000.00 75000.00
welded & pop rivetted as required. The
hood will be complete with s.s.sheet
removable type baffle filters. Complete
with greese collection channel & greese
collection cup/s.

Sign and Stamp of EPIL 71 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR

FOOD TROLLEY WITH 4 ROUND PANS, 1


RICE TRAY & STORAGE beneath
O/S 1350X750X900mm
S.S.Sheet insulated body, Frame
work of m.s. anlge of size
35 MR 38x38x5mm, mounted on 4 castors (2 4 Nos. 75000.00 300000.00
with brakes) of size 150mm top to have
cutout for 4nos. Round pans for Dal,
Subzi etc. with 1 rice tray & storage
below. Three side covered with s.s.sheet
with s.

TRAY CARRIER TROLLEY


Size 1200X600X1200mm
S.S.Bottom base shelf mount at 150mm
with all four sides turned down
50mm in 12mm and secured to welded
s.s.anlge frame work & PROVIDED WITH
36 MR 1 No. 65000.00 65000.00
THREE NOS. OF DETACHABLE TRAYS
CUM SHELFS UNIT WILL BE MOUNTED
ON 4" PILLAR TYPE CASTORS WHEELS
(2
NOS. WITH BRAKE & 2 NOS. WITHOUT
BRAKE)

TRAY SET UP COUNTER WITH BAIN


MARIE & DOUBLE OVERSHELVES
Size 1800x600x850+375+225
Top of 16G s.s.sheet, Bain Marie water
tank of
18G s.s.sheet, fitted with 3.0kw heating
37 MR 2 Nos. 162500.00 325000.00
element with automatic temperature
controller. Water outlet provision with
drain valve, 3 sides covered with
20G s.s.sheet, Top to accommodate
s.s.sheet Food Pans with GN pan
1x2x4" depth with lid 5 sets.

STORAGE CABINET
Size 1200X600X850mm
Top of 16Swg S.S.Sheet one over shelf,
38 MR 2 Nos. 60000.00 120000.00
three sides of 20SWG s.s. sheet. Dish
storage cabinet with 2 shelves and sliding
door will be provided on service side.

Sign and Stamp of EPIL 72 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR
STORAGE RACK
Size 900X450X1800
39 MR Vertical of 32 mm dia stainless steel pipe 6 Nos. 39000.00 234000.00
with adjustable feet 4 no of 18 S.S Sheet
at equaly distance.
INGREDIENT BINS
Size 600X600X600mm
Made of S.S. 18 SWG WITH TOP
40 MR HINGE OPENABLE DOORS SUPPORT 4 Nos. 26000.00 104000.00
WITH FOUR NOS. OF CASTORS, anti
crack body, top half hinged lid. Provided
with a scoop.
DUNNAGE RACK
Size 1200X600X500mm
41 MR Made of s.s.square pipes of size 2 Nos. 27000.00 54000.00
32x32mm, with support of 25mm
square s.s.pipe.
POT RACK-3 TIER
Size 1200X600X1500mm
Verticals of 32mmX32mm square
42 MR s.s.pipe, 3 shelves welded with vertical 2 Nos. 39000.00 78000.00
frame of 19mm dia s.s.pipe shelves
with equal space between two tubes
mounted on adjustable feet.

SOILED DISH LANDING TABLE


WITH GARBAGE CHUTE
Size 2400x600x850mm
Top of 16G s.s.sheet with 'Sunkun'
top. A garbage chute provided on top
43 MR 1 No. 80000.00 80000.00
with a space below to keep dust bin
(Not part of equipment). The top will be
mounted on m.s.anlge, rust proof
painted & s.s.vertical tubular legs with
cross bracing support on 3 sides

THREE SINK UNIT


Size 1800x600x850+150mm
Top & 3 sink bowls of 16G s.s.sheet.
Duly welded, grinded & polished smooth
44 MR 1 No. 85000.00 85000.00
mounted on m.s.anlge & s.s.tubular
frame work with 150mm back splash.
Each Sink Bowl Size 500x500x300mm
(without sanitory fittings)

Sign and Stamp of EPIL 73 Sign and Stamp of Bidder


Quantity Rate Amount
Sr.No
Code Description As Per Unit
. MR
Boq / MR
CLEAN DISH TABLE
Size2100x600x850mm
45 MR 1 No. 77000.00 77000.00
Specification same as that of work table
but with 2 undershelves.

CLEAN DISH RACK


Size 900x450x1800mm
Vertical of 32 mm dia stainless steel pipe
46 MR 5 Nos. 39000.00 195000.00
with adjustable feet 5 no vertical at equal
distance 1st shelf fixed at 150mm from
floor level.

L.P.G GAS PIPE LINE (150 RUNNING


FEET APPROX)
47 MR 1 No. 236250.00 236250.00
ACTUAL MEASUREMENT WILL BE
ACCORDING TO As per site conditions

CENTRIFUGAL EXHAUST BLOWER


48 MR 1 No. 330000.00 330000.00
20000 CFM

S.S GRATING for kitchen drainage trough


(APPROX 25 RUNNING FEET)
49 MR 25 RFT 6000.00 150000.00
ACTUAL MEASUREMENT WILL BE
ACCORDING TO As per site conditions

EXHAUST HOOD DUCTING (APPROX


1200 SQUARE FEET)
50 MR 1 No. 285000.00 285000.00
ACTUAL MEASUREMENT WILL BE
ACCORDING TO As per site conditions

TOTAL 5,728,750.00

Sign and Stamp of EPIL 74 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai
SCHEDULE ITEMS (LAUNDRY)- BOQ
Quantity Rate Amount
Sr.N Unit
Code Description As Per MR
o.
Boq/
Supply, Installation, Testing and
commissioning etc as
required for the follwing items
required for the Laundry.
TUMBLE DRIER
1 MR CAPACITY : 30 KG HEATING: STEAM 1.00 No 160000.00 160000.00

FLAT WORK IRONER


ROLLER LENGTH: 2000MM ROLLER
2 MR 1.00 No 610000.00 610000.00
DIA: 600 MM HEATING : STEAM

WASH ROOM TROLLEY


3 MR 2.00 Nos 18900.00 37800.00
Size: 1000 x 600 x 780 ht.
DRY LINEN TROLLEY
4 MR 2.00 Nos 19600.00 39200.00
Size: 1100x600x1500ht
SHELF TROLLEY
5 MR 1.00 No. 22500.00 22500.00
Size: 1200x600x1700ht
MOBILE TABLE
6 MR 1.00 No. 18000.00 18000.00
Size: 1150x750
VACUUM FINISHING TABLE
7 MR Size: 1200 x 750 2.00 No 45000.00 90000.00
With Steam Iron
WASHER EXTRACTOR CAPACITY :
8 MR 2.00 No 520000.00 1040000.00
30 Kgs HEATING: STEAM
AIR COMPRESSOR
9 MR 1.00 No 97000.00 97000.00
2 HP Single Stage, 100 ltrs. Tank
OIL FIRED BOILER WITH SOFTNER
10 MR Capacity : 200 Kgs 1.00 No 474500.00 474500.00

11 MR Piping 1.00 Set 125000.00 125000.00


Flat Bed Press - penumatic,
automatic, steam heated, automatic
digital timed powerful moisture
suction boiler. Penumatic raising
12 MR 1.00 No 279502.00 279502.00
and lowering of spring suspended
and teflon line head, adjustable
irponing pressure head size
1500x750
laundary scrub station with two
13 MR sinks - all ss size 1600x550x900 ht 1.00 No 85653.00 85653.00

TOTAL 3,079,155.00

Sign and Stamp of EPIL 75 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai
SCHEDULE ITEMS ( Medical Gas System) - BOQ
Quantity Rate
Sr.N As Per
Code Description Unit
o. Boq/ MR Amount
Revison I

Supply, Installation, Testing and


1 MR commissioning etc as required for Medical
Call System:

Part - A : Medical Gas System.


Supply, Installation, Testing, Commissioning
and Handing Over of Medical Air Compressor
unit of 2 Nos (1 working and 1 standby) non
lubricated reciprocating air cooled air
compressors ( Ingersoll Rand , Anestiwata,
Kirloskar Make) with 60 CFM refrigerant
type air drier with Prefilter, After filter, 20
HP TEFC cage motors, drive package,
suction air filters, starter, mounting base
frame complete with Air colled after cooler,
1a MR 1.00 Set 1000000.00 1000000.00
Pressure Reducing Station. The operation
of the compressors shall be having auto
cutoff system according to the preset
pressures for the lower and upper limit.
The system shall have all the necessary
controls like pressure switches, relief valves,
etc. including Supply, Installation, testing,
commissioning and handing over of Air
receiver for the above compressors with
a storage volume of 2000 ltrs at NTP
conditions.

Three stage Breathing Air Filtration System


1b MR ( Imported ) with By pass pipeline system 1.00 Set 200000.00 200000.00
with Isolation Valves.

Sign and Stamp of EPIL 76 Sign and Stamp of Bidder


Quantity Rate
Sr.N As Per
Code Description Unit
o. Boq/ MR Amount
Revison I
Supply, Installation, Testing, Commissioning
and Handing Over of Medical Vacuum
Pump Unit reciprocating type ( Ingersoll
Rand, Kirloskar Make ) comprising of 2 Nos
vacuum pumps ( 1 working and 1 standby )
with 10 HP TEFC cage motors, drive
package, bacterials filter at the discharge,
mounting base frame complete. The
operation of the vacuum pumps shall be
having auto cutoff arrangement according
2.a MR to the preset pressures for the lower 1.00 Set 900000.00 900000.00
and upper limit. The system shall have
all necessary controls like pressure switch,
etc. including Supply, Installation, Testing,
Commissioning and Handing over of
Receiver for the vacuum pumps with a
storage volume of 2000 ltrs at NTP
conditions.

Bacterial Filter Vacuum ( Imported ) with


2.b MR By pass pipeline system with 1.00 Set 250000.00 250000.00
Isolation valves.
Supply, Installation, Testing, Commissioning
and Handing over of Oxygen Manifold
comprising of 2 x 10 Oxygen cylinders in the
3.a MR main manifold and 2 x 4 cylinders in the 1.00 Set 175000.00 175000.00
emergency manifold with Piston type Heavy
duty, High flow Oxygen Regulator.

Fully Automatic Oxygen Control


3.b MR 1.00 Nos 300000.00 300000.00
Panel Pneumatically operated. (Imported )

Supply, Installation, Testing,


Commissioning and Handing over of
4.a MR Nitrous Oxide Manifold comprising of 2 x 3 1.00 Set 56500.00 56500.00
N2O cylinder in the main manifold with a 2
cylinders in the Emergency manifold.

Fully Automatic Nitrous Oxide Control


4.b MR 1.00 Nos 325000.00 325000.00
Panel Pneumatically operated. ( Imported )

AGSS System consisiting of Duplex, Skid


5 MR Mounted AGSS Pumps with Remote Switches 1.00 Set 2000000.00 2000000.00
- AGSS Simplex Start Switch. ( Imported )

Sign and Stamp of EPIL 77 Sign and Stamp of Bidder


Quantity Rate
Sr.N As Per
Code Description Unit
o. Boq/ MR Amount
Revison I
Supply, Installation, Testing, Commissioning
and Handing over of Solid drawn copper
pipes manufactured as per BS 2871 - EN
6 MR 0.00
1057 duly certified by LLoyds with all
necessary fittings, pipe supports, etc
complete.

a). 12 mm OD x 0.7 mm thk 805.00 RMT 300.00 241500.00

b). 15 mm OD x 0.9 mm thk 2650.00 RMT 500.00 1325000.00

c). 22 mm OD x 0.9 mm thk 815.00 RMT 800.00 652000.00

d). 28 mm OD x 0.9 mm thk 285.00 RMT 1200.00 342000.00

e). 54 mm OD x 1.2 mm thk 90.00 RMT 3600.00 324000.00


Supply, Installation, Testing, Commissioning
7 MR and Handing over of Valve Boxes with 0.00
pressure gauges.
a). 5 Gas Service 6.00 Nos 15000.00 90000.00

b). 4 Gas Service 2.00 Nos 12000.00 24000.00

c). 3 Gas Service 5.00 Nos 10000.00 50000.00

d). 2 Gas Service 17.00 Nos 7000.00 119000.00


Supply, Installation, Testing, Commissioning
and Handing over of Isolation Ball valves
for the pipelines complete with
supports, etc. These quantities do not
8 MR 0.00
include the valves in the equipment
room, which shall be quoted as included
in the equipment as specified above.

a ). 1/2" 50.00 Nos 2000.00 100000.00

b). 3/4" 20.00 Nos 2800.00 56000.00

c). 1" 1.00 Nos 3500.00 3500.00

d). 2" 1.00 Nos 7500.00 7500.00

Supply, Installation. Testing, Commissioning


9 MR 0.00
and Handing over of Area Line Pressure Alarm

Sign and Stamp of EPIL 78 Sign and Stamp of Bidder


Quantity Rate
Sr.N As Per
Code Description Unit
o. Boq/ MR Amount
Revison I
a). 5 Gas Alarm 5.00 Nos 50000.00 250000.00

b). 4 Gas Alarm 1.00 Nos 45000.00 45000.00

c). 3 Gas Alarm 4.00 Nos 40000.00 160000.00

d). 2 Gas Alarm 4.00 Nos 35000.00 140000.00

Supply, Installation, Testing, Commissioning


10 MR and Handing over of Gas outlets Points 0.00
with Matching Probes (Imported ).

a). Oxygen Outlet 152.00 Nos 5000.00 760000.00

b). Nitrous Oxide Outlet 24.00 Nos 5000.00 120000.00

c). Compressed Air Outlet ( 4 Bar ) 62.00 Nos 5000.00 310000.00

d). Compressed Air Outlet ( 7 Bar ) 11.00 Nos 5000.00 55000.00

e). Vacuum Outlet 152.00 Nos 5000.00 760000.00

f). AGSS Outlet 5.00 Nos 6000.00 30000.00


Electrical Control Panel Equipped along
11 MR with Duplex & Cascade system for Air 1.00 Set 250000.00 250000.00
compressor & vacuum Pump System

Part A - Total 0.00

MEDICAL GAS B SYSTEM: 0.00


Supply, Installation, Testing and
commissioning etc as required for 0.00
Medical Call System:
Part - B : Pipeline Accessories.
Back pressure Compensated Oxygen
flowmeters with a range of 0 - 15 LPM. The
body shall be made of brass and chromium
plated. The flow tube shall be of clear,
impact resistant polycarbonate. The
1 MR humidifiers bottles shall be made of 152.00 Nos 1500.00 228000.00
breakable polycarbonate and are
autoclavable at 134 Deg C. The meters and
humidifiers shall be suitable for the outlets
offered.

Sign and Stamp of EPIL 79 Sign and Stamp of Bidder


Quantity Rate
Sr.N As Per
Code Description Unit
o. Boq/ MR Amount
Revison I
Ward Vacuum Units with unbreakable
collection jars and regulators. The unit shall
be supplied with vacuum guage to indicate
2 MR the suction supplied to the unit. The unit shall 152.00 Nos 4000.00 608000.00
have a bracket for wall mounting. The jars
shall be made of unbreakable polycarbonate
and are autoclavable at 134 Deg C.
Theatre Vacuum Units on mobile trolleys with
twin 2000 ml unbreakable bottles made
of polycarbonate, autoclavable at 134
Deg C. The unit shall be supplied with a
regulator with instant ON/OFF switch
3 MR 12.00 Nos 8000.00 96000.00
and three way selection to use the left,
right or both the bottles. The complete
unit shall be mounted on a trolley with castor
wheels.

Conversion Kits for Oxygen with HP Tubing


4 MR 6.00 Nos 2500.00 15000.00

Conversion Kits for Nitrous Oxide with HP


5 MR 6.00 Nos 2500.00 15000.00
Tubing
MEDICAL GAS C SYSTEM: 0.00
Supply, Installation, Testing and
commissioning etc as required for 0.00
Medical Call System:
Part - C : Bed Head Wall Panels 1 meter
length
Supply, installation and providing wiring and
piping connections for bed head wall
panels. The panel shall be fabricated out
of high strengths extruded alluminium
sections with inbuilt single railing and
powder coated to color as per the Owners
choice. The panel shall have facility to
accomodate : Max. 5 nos of Gas outlets,
1 MR 146.00 Nos 25000.00 3650000.00
5/15 A multi pin switched socket outlets -
4 nos, 1 no Nurse call switch panel with
wired remote, 1 no arm lamp 60W with
adaptor, 1 no Infusion pump rail mount
pole with adaptor, 1 no IV tree rail mount
with adaptor and holder for vacuum
collection jar To be included with OT
Equipments

Part C - Total

TOTAL 16,033,000.00

Sign and Stamp of EPIL 80 Sign and Stamp of Bidder


Name of Work- Construction of 100 Bedded Hospital for ESIC Bhilai
Schedule of Items- Signage - BOQ
TOTAL
Sr no Description Unit RATE AMOUNT
OTY
220 MR Providing of signages, modular curved frame
technology,of various widths and lengths, to form
suggested usages,made of aluminium extruded
sections , duly anodised ,all signages shall be
provided with 0.6-0.8mm polycarbonate
protecting film over the prints, of appropriate size,
Model : Illusion by SIGNSUTRA or Equivalent.

Way finding Signs


Way finding ceiling hung sign(both side) 1200x300 each 30 17592 527760.00
Toilets
Toilet Wall Projected(Gents, Ladies, Handicap, 250x210 each 31 3832 118792.00
PatientDoor
Toilet bothmounted(Gents,
side) Ladies, Handicap, 120x150 each
755
Patient both side) 35 26425.00
Cubical Plates 120x150 each 99 755 74745.00
Change room with Toilet (Gents, Ladies & Nurse) 250x210 each 13 3832 49816.00
Wall
DressProjected (both Side)
/Janitor closet 120x150 each 10 755 7550.00

Name plate
Number plate 80x120 each 115 358 41170.00
Room designation 80x300 each 133 691 91903.00
Doctor's/ Occupant's name 80x300 each 37 691 25567.00
Wall mounted over Door 150x600 each 70 3621 253470.00

Nurse Station 0
Wall projected(both side) 250x210 each 6 3832 22992.00
Door mounted 120x150 each 8 755 6040.00

Radiography/MRI/CTScan etc.
Wall projected(both side) 250x210 each 4 3832 15328.00
Door mounted 120x150 each 4 755 3020.00
Waiting Lounge
Wall mounted 150x600 each 13 3621 47073.00

Others
Lifts (Elevators nos.) 400x120 each 20 2416 48320.00
Lifts Wall Projected 250x210 each 10 3832 38320.00
Stairs Wall Projected(both side) 250x210 each 19 3832 72808.00
Door mounted 120x150 each 19 755 14345.00
Drinking Water 400x120 each 10 2416 24160.00
Electric / AHU rooms 400x120 each 5 2416 12080.00
Bed number in more than 2 bedded rooms 80x120 each 174 358 62292.00

Sign and Stamp of EPIL 81 Sign and Stamp of Bidder


TOTAL
Sr no Description Unit RATE AMOUNT
OTY
221 MR Providing of prohibition and general
signage,made of 0.8mm thick aluminium
sheet duly painted with Polyurethene paint of
approved make and shade, aluminium sheet
bented to form a curve , and supported by
moulded plastic components to hold the
curve , the moulded plastic components to be
fixed on aluminium rails with clip on arrangment,
as per the product design of model: POLKA,
manufectured by Signsutra
or equivalent.
Directory at Lift Lobby
Floor(levels) 385x385 each 10 4076 40760.00
Department 385x385 each 20 4076 81520.00
Registeration/Reception etc. 0
Ceiling hung over counter(both sides) 750x235 each 6 13864 83184.00
Department Direction 0
Wall mounted 600x320 each 20 4946 98920.00
Corner mounted 2x600x320 each 0 9892 0.00
Department Name 0
Ceiling hung (both sides) 1000x235 each 0 18342 0.00
Waiting Lounge 0
Ceiling hung (both sides) 1000x235 each 0 18342 0.00
Providing and fixing prohibition signage , made of
Aluminium composite panel and all text and
pictograms as screen orinted and malamine
coated, all fixtures in 304 grades SS, all designs as
per architect approval
Silent Zone 200x200 each 40 787 31480.00
No Smoking 200x200 each 50 787 39350.00
Safety Notice- be kept clear to Emergency carts 200x200 each
787
25 19675.00

222 MR Providing of Snap fit frames,made of aluminium


extruded profiles duly anodized , and shall be also
provided with .8mm thick polycarbonate film to
protect /hold the insertions. And 8mm thick
MDF, as main
inserion panel.
SNAP FIT FRAMES 450x600 each 50 3933 196650.00

223 MR Providing of 1.5mm,polished,304 grade,Stainless


steel plate, DISCLAIMER
ELEVATOR duly etched and filled with prescribed 250x250
PLATE each 10 2360 23600.00

Sign and Stamp of EPIL 82 Sign and Stamp of Bidder


TOTAL
Sr no Description Unit RATE AMOUNT
OTY
224 MR Providing of edge lit ,emergency exit sign with 2
hrs power back up, concealed in false ceiling,of
PROLITE AUTOGLO make
or equivalent
LED SIGN (CONCEALED)with 2hr backup standard each 41 8296 340136.00
EXIT LIGHT WITH 2 HR BACKUP(Exit at standard each
6794
Stairs entry/ Deptt. Exit) 21 142674.00

225 MR Providing of Photoluminescent,


1mm rigid pvc based sheet containg lumingen
3, as base chemical,with high intensity luminous
glow capacity.
PHOTOLUMINESCENT SIGN , FIRE HOSE 250x200 each 25 1831 45775.00
PHOTOLUMINESCENT SIGN,ESCAPE SIGN 400x150 each 60 2197 131820.00
PHOTOLUMINESCENT SIGN,FIRE ALARM CALL 200x150 each
1098
POINT 25 27450.00
PHOTOLUMINESCENT SIGN, EVACUATION PLAN 300x200 each 17 2912 49504.00
PHOTOLUMINESCENT SIGN,PULL AND PUSH 90mm DIA each 104 292 30368.00
226 MR Providing of internally illuminated signage made
with CNC cut ACP(aluminium composite
panel)with insertions of text and pictogram of
10mm thick laser cut acrylic, duly cladded with
electrocut casted 3M vinyl of required color,
illumination by GE or Phillips LED, as per Design.

Radiography/MRI/CTScan etc.
In use (illuminated) 400x400 each 3 9726 29178.00

231 MR Providing of Floor Directory (TOTEM) of size


measuring 1500mmx3000mm in the main
entrance Lobby/ Foyer fabricated with MS rigid
sections of allied sizes to design developed by M/S
SIGNSUTRA.
Floor Directory (TOTEM) 1500x3000 each 5 57607 288035.00

232 MR Providing of Main Directory assembeled with


standard alluminium alluminium extruded plates,
duly anodized.The plates shall be of size 1no. of
1000x120mm as top subject plate and
10nos. 1000x100 mm contents plates. Each of the
plates shall be provided with 0.8 mm thick
polycarbonate protecting film over the printed
text. model: Illusion by SIGNSUTRA or equivalent.

Main Directory 1000x1120 each 1 352 352.00

Sign and Stamp of EPIL 83 Sign and Stamp of Bidder


TOTAL
Sr no Description Unit RATE AMOUNT
OTY
233 MR Providing of Main Directory assembeled with
standard alluminium alluminium extruded plates,
duly anodized.The plates shall be of size 1no. of
1000x120mm as top subject plate and
10nos. 1000x100 mm contents plates (inclusive of
Dr.'s name and 'In''Out' sections). Each of the
plates shall be provided with 0.8 mm thick
polycarbonate protecting film over the printed
text. model: Illusion by SIGNSUTRA or equivalent.

Doctors' Directory 1000x1120 each 1 35254 35254.00


238 MR Providing of Evacuation floor plans measuring
500mmx 600mm made of 5 mm foam board and
1mm thick rigid plastic photoluminiscent printed
plans framed into
45mmx 20 mm extruded aluminium tubuklar
frame with necessary holding slots.

Evacuation Plans Floor wise 500x600 each 36 9297 334692.00

239 MR Providing of Entrance Gate External Signage as per


design developed by SIGN SUTRA
TOTAL 3654353.00

Sign and Stamp of EPIL 84 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

Schedule of Items-TSSU EQUIPMENTS- BOQ

S.N. DESCRIPTION UNIT


QTY RATE AMOUNT
High speed high pressure horizontal cylinder
1 NOS. 844590
steam sterlizer 1 844590
Nat steel high speed high pressure horizontal
cylindrical Steam sterllizer.Operating pressure will
be 30 ps. Corresponding to a temp. of 134.
2 s.s work table NOS. 1 75278 75278
Table is used for wet goods with underself.
3 S.S vertical sliding door NO. 1 114134 114134
Door is used between clean and dirty areas in
hospitals,pharmaceuticals etc.
4 S.S. control and packing table with drawer NO. 1 251090 251090

Table with drawer is used for seperation,control


and packing of various sets of sterlized.
5 s.s work table with two sink NO. 1 194978 194978
The bench top is fabricated out of 16 swg ss 304.
6 Washer disinfector NO. 1 1133732 1133732
Washer disinfector,single door,suitable for
cleaning .
7 Ultrasonic Cleaner NO. 1 540233 540233
Ultrasonic Cleaner of overall size 530x330x350.
8 Drying cabinet with single door NO. 1 677195 677195
Digital timer controlled drying cabinet with the
single door suitable for easy and quick drying of
instrument.
9 Stainless Steel work table NO. 1 75278 75278
Table is used for wet goods with underself.
10 Stainless Steel racks with 5 shelves NOS. 1 144571 144571
Total 4051079

Sign and Stamp of EPIL 85 Sign and Stamp of Bidder


PROJECT: PROPOSED 100 BED ESIC HOSPITAL AT BHILAI, CHHATTISGARH.
BOQ FOR ELECTRICAL WORK IN ESIC HOSPITAL, BHILAI
Sl.no. DSR-16 Description of items Unit QTY Rate Amount

SUB HEAD : I. WIRING AND SUB MAINS

Wiring for light point/ fan point/ exhaust fan point/


call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface /
recessed steel conduit, with modular switch,
1.01 1.3.3 point 1108 1037 1148996
modular plate, suitable GI box and earthing the
point with 1.5 sq.mm FRLS PVC insulated copper
conductor single
core cable etc. as required.

Wiring for light point/ fan point/ exhaust fan point/


call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface /
recessed PVC conduit, with modular switch ,
1.02 1.10.2 point 777 615 477855
modular plate, suitable GI box and earthing the
point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable etc as required.for
Housing

Wiring for twin control light point with 1.5 sq.mm


FRLS PVC insulated copper conductor single
core cable in surface /recessed steel conduit, 2
1.03 1.4 way modular switch, modular plate,suitable GI box point 20 1094 21880
and earthing the point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable etc.
as required.( Lift well )

Wiring for twin control light point with 1.5 sq.mm


FRLS PVC insulated copper conductor single
core cable in surface /recessed medium class
PVC conduit, 2 way modular switch, modular plate,
1.04 1.11 point 22 809 17798
suitable GI box and earthing the point with 1.5
sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required.( FOR
COMMON SERVICE )for Housing

Wiring for group controlled (looped) light point / fan


point / exhaust fan point/ call bell point (without
independent switch etc.) with1.5 sq. mm FRLS PVC
insulated copper conductor single core cable in
1.05 1.54 point 843 601 506643
surface/ recessed steel conduit, and earthing the
point with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable etc. as required.-group-
C

Wiring for group controlled (looped) light point/fan


point/exhaust fan point/ call bell point (without
independent switch etc.) with 1.5 sq. mm FRLS
PVC insulated copper conductor single core cable
1.06 1.55.3 in surface/ recessed PVC conduit, and earthing the point 67 415 27805
point with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable etc. as required. ( FOR
COMMON SERVICE )for Housing

Sign and Stamp of EPIL 86 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Wiring for circuit/ submain wiring alongwith earth
wire with the following sizes of FRLS PVC
1.07 1.7.2 insulated copper conductor, single core cable in mtrs 7110 206 1464660
surface/ recessed steel conduit as required. 2 X
2.5 sq. mm + 1 X 2.5 sq. mm earth wire

Wiring for circuit wiring alongwith earth wire with the


following sizes of FRLS PVC insulated copper
1.08 1.14.2 conductor, single core cable in surface/ recessed mtrs 1408 137 192896
PVC conduit as required - 2 x 2.5 sq. mm + 1x 2.5
sq. mm earth wire

Wiring for circuit/ submain wiring alongwith earth


wire with the following sizes of FRLS PVC
insulated copper conductor, single core cable in
1.09 1.7.2 mtrs 10188 206 2098728
surface/ recessed steel conduit as required. 2 X
2.5 sq. mm + 1 X 2.5 sq. mm earth wire (for LIGHT
PLUG )

Wiring for circuit wiring alongwith earth wire with the


following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed
1.10 1.14.1 mtrs 120 112 13440
PVC conduit as required - 2 x 1.5 sq. mm + 1x 1.5
sq. mm earth wire ( FOR COMMON SERVICE )

Wiring for circuit/ submain wiring alongwith earth


wire with the following sizes of FRLS PVC
insulated copper conductor, single core cable in
1.11 1.7.2 mtrs 2180 206 449080
surface/ recessed steel conduit as required. 2 X
2.5 sq. mm + 1 X 2.5 sq. mm earth wire (for FCU )

Wiring for circuit wiring alongwith earth wire with the


following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed
1.12 1.14.2 mtrs 1840 137 252080
PVC conduit as required - 2 x 2.5 sq. mm + 1x 2.5
sq. mm earth wire for LIGHT PLUG for Housing

Wiring for power plug with 2X4 sq. mm FRLS PVC


insulated copper conductor single core cable in
surface/ recessed steel conduit alongwith 1 No 4
1.13 1.7.3 mtrs 1810 237 428970
sq. mm FRLS PVC insulated copperconductor
single core cable for loop earthing as required.

Wiring for power plug with 2X4 sq. mm FRLS PVC


insulated copper conductor single core cable in
surface/ recessed PVC conduit alongwith 1 No 4
1.14 1.14.3 mtrs 2192 168 368256
sq. mm FRLS PVC insulated copperconductor
single core cable for loop earthing as required. for
Housing

Wiring for sub main wiring with the following


sizes of PVC insulated, copper conductor, cable
1.15
in surface /recessed steel conduit as required.

4 X 10 sq. mm + 2 X 6 sq. mm earth wire for floor


a) 1.7.10 mtr 1110 653 724830
panel to DB
4 X 16 sq. mm + 2 X 6 sq. mm earth wire for floor
b) 1.7.11 mtr 1620 930 1506600
panel to DB (for 12 WAY

Sign and Stamp of EPIL 87 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Wiring for sub main wiring with the following
sizes of PVC insulated, copper conductor, cable
1.16
in surface /recessed PVC conduit as required. for
Housing
2 X 10 sq. mm + 1 X 6 sq. mm earth wire (TYPE-
a) 1.14.5 mtr 426 299 127374
II & TYPE-III)
4 X 10 sq. mm + 2 X 6 sq. mm earth wire for floor
b) 1.14.10 mtr 204 536 109344
panel to DB for Type-IV

Supply and fixing suitable size GI box with modular


plate and cover in front on surface or in recess,
1.24.1+1
including providing and fixing 3 pin 5/6 & 5/6 amps
1.17 .24.4+1. each 941 350 329350
modular socket outlet and 5/6 amps modular
27.2
switch, connection, painting etc as required.

Supply and fixing suitable size GI box with modular


plate and cover in front on surface or in recess,
1.24.1+1
including providing and fixing 3 pin 5/6 & 5/6 amps
1.18 .24.4+1. each 109 350 38150
modular socket outlet and 5/6 amps modular
27.2
switch, connection, painting etc as required.for FCU
& Inline fan

Supply and fixing suitable size GI box with modular


plate and cover in front on surface or in recess,
1.27.4+1 including providing and fixing two nos 3 pin 5/6 &
1.19 .24.4*2+ 5/6 amps modular socket outlet and one 5/6 amps each 191 504 96264
1.24.1 modular switch connection , painting etc as
required.for TV power & Computer point

Supply and fixing suitable size GI box with modular


plate and cover in front on surface or in recess,
1.24.3+1
including providing and fixing13 Amp universal
1.20 .27.2+1. each 608 454 276032
modular socket outlet and 15/16 amps modular
24.5
switch, connection, painting etc as required.

Supply and fixing suitable size GI box with modular


plate and cover in front on surface or in recess,
1.27.5+1
including providing and fixing three nos 3 pin 5/6
1.21 .24.4*3+ each 200 624 124800
& 5/6 amps modular socket outlet and 5/6 amps
1.24.1
modular switch, connection , painting etc as
required.for ups power

Supplying and fixing 20 A, 240 V, SPN Industrial


type socket outlet, with 2 pole and earth, metal
enclosed plug top alongwith 20 A, “C” curve, SP,
MCB, in sheet steel enclosure, on surface or in
1.22 2.18 each 40 980 39200
recess, with Chained metal cover for the socket out
let and complete with connections, testing and
commissioning etc. as required. for AC +gyeser for
Housing

Supplying and fixing stepped type electronic fan


regulator on the existing modular plate switch box
1.23 1.25 each 390 288 112320
including connections but excluding modular plate
etc. as required.

Sign and Stamp of EPIL 88 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Providing and fixing circular/ Hexagonal GI box for
ceiling fan clamp, of internal dia 140 mm, 73 mm
(DSR height, top lid of 1.5 mm thick GI sheet with its top
Civil- surface hacked for proper bonding, top lid shall be
1.24 2014, screwed into the GI box by means of 3.3 mm dia each 390 143 55750.5
Item no. round headed screws, one lock at the corners,
10.18) clamp shall be made of 12 mm dia M.S. bar bent to
shape as per standard drawing. Rate to be taken

25 amp DP MCB in IP 65 box (outdoor type) for AC


1.25 MR each 2 2127 4254
Outdoor Unit)

Total carried over to summary Rs. 11013355.50

SUB HEAD-II CONDUIT PIPES AND METAL BOXES FOR


AND OTHER SERVICES.

Supplying and fixing of Following sizes of


PVC conduit along with the accessories like
Junction boxes, bends, socket, fish wire etc. on
2.01 surface/recess with M.S. Clamps, nuts and
bolts including cutting of the wall and making
good the same in case of recessed conduit as
required. for LV
a) 1.21.1 20mm mtr 580 57 33060
b) 1.21.2 25mm mtr 6712 69 463128
c) 1.21.3 32mm mtr 1080 89 96120
d) 1.21.4 40mm mtr 230 114 26220

Supply, fixing, connecting and testing of


telephone / computer / TV modular sockets
2.02 modular plate anodised MS box and blanking
plate in surface / recessed including connectionetc
as required.
124.6+1 RJ-11 telephone socket two line with shutter
a) each 168 271 45528
27.1
124.7+1 T.V. CO-axial cable socket outlets of one point
b) each 46 272 12512
27.1

Supplying and fixing following size/ modules, GI


2.03 box alongwith modular base & cover plate for
modular switches in recess etc. as required.
1.27.2 3 Module (100 mmX75 mm) for existing RJ 45 each 182 185 33670

Providing, fixing connecting and testing of


solder less telephone tag block of following
2.04 capacity ties as required in suitable size of
m.s. hinged lockable cover box duly painted
etc. as required of Krone type.
a) MR 10 pair Tele Tag Blk. each 11 900 9900
a) MR 50 pair Tele Tag Blk. each 5 3000 15000
b) MR 100 pair Tele Tag Blk. each 2 4500 9000

Supplying and drawing following pair, 0.5 sq.mm


FR PVC insulated coper conductor, unarmoured
2.05
telephone cable in existing surface / recessed steel
/ PVC conduit as required.
a) 1.18.2 2 pair Telephone cable. (0.5sq mm) mtr. 7200 19 136800
b) MR 10 pair Telephone cable mtrs 1000 95 95000

Sign and Stamp of EPIL 89 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supplying and drawing co-axial TV cable RG-6
grade, 0.7 mm solid copper conductor PE
insulated, shielded with fine tinned copper braid
2.06 1.19 mtr. 970 29 28130
and protected with PVC sheath in the existing
surface/ recessed steel / PVC conduit as required.(
for TV )

Total carried over to summary Rs. 1004068.00

SUB HEAD-III DISTRIBUTION BOARD


Supplying and fixing following way, horizontal type
three pole and neutral, sheet steel, MCB
distribution board, 415 V, on surface/ recess,
3.01 complete with tinned copper bus bar, neutral bus
bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But
without MCB / RCCB / Isolator)
3.01 a) 2.4.1 4 way (4 + 18), Double door each 4 2198 8792
3.01 b) 2.4.2 6 way (4 + 18), Double door each 14 2659 37226
3.01 c) 2.4.3 8 way (4 + 24), Double door each 27 3171 85617

vertical type, 415 V, TPN MCB distribution board of


sheet steel,dust protected, duly powder painted,
inclusive of 200 A, tinned copper bus bar,
3.02
common neutral link, earth bar, din bar for
mounting MCBs (but without MCBs and incomer)
as required.
2.5.3 12 way (4 + 36), Double door for Power DB each 54 7189 388206

Supplying and fixing following way, single pole and


neutral, sheet steel, MCB distribution board, 240
V, on surface/ recess, complete with tinned
3.03 copper bus bar, neutral bus bar, earth bar, din
bar, interconnections, powder painted including
earthing etc. as required. (But without MCB / RCCB
/ Isolator)

a) 2.3.1 6 way, Double door for COMMON each 7 942 6594


b) 2.3.3 12 way, Double door for TYPE-II & TYPE-III each 24 1151 27624

Supplying and fixing of following ways surface/


recess mounting, vertical type, 415 V, TPN MCB ,
distribution board with MCCB incomer of sheet
steel, dust protected, duly powder painted, inclusive
of 200 A, tinned copper bus bar, common neutral
3.04 N.S.R.
link, earth bar, din bar for mounting MCBs (but
without MCBs and incomer) as required. (Note :
Vertical type MCB TPDB is normally used where 3
phase outlets are required.) as Light, power, UPS
Floor DB
3.04 a) N.S.R. 8 way (4 + 24), Double door ( for LIGHT +UPS) each 12 21575 258900
3.04 b) N.S.R. 12 way (4 + 36), Double door ( for POWER ) each 6 22343 134058

Incomer :-
Supplying and fixing upto 32 amps rating, 240/415
volts, “C”curve, miniature circuit breaker suitable for
inductive load of following poles in the existing MCB
3.05
DB complete with connections,testing and
commissioning etc. as required.

Sign and Stamp of EPIL 90 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

3.05 a) 2.10.5 Triple pole and neutral 32 amp for Light DB each 61 891 54351
b) 2.10.1 6-32 Amp (10 KA) SP MCB C' Series each 2668 173 461564
c) 2.10.3 Double pole each 27 463 12501
d) N.S.R. 40A FP MCB each 18 3008 54144
e) N.S.R. 63A FP MCB each 73 3008 219584

Supplying and fixing following rating, double pole,


(single phase and neutral), 240 volts, residual
current circuit breaker (RCCB),having a sensitivity
3.06
current upto 300 milliamperes in the existing MCB
DB complete with connections, testing and
commissioning etc. as required.
RCCB's :-
63 Amp SPN RCCB with 30 ma fault current rating
a) 2.14.3 each 168 2242 376656
(1 No. per phase) for L+P- DB
40 Amp SPN RCCB with 30 ma fault current rating
a) 2.14.2 each 48 1719 82512
(1 No. per phase)
40 Amp 4P RCCB with 30 ma fault current rating
b) 2.15.2 each 2 2131 4262
for M/C Room
25 Amp SPN RCCB with 30 ma fault current rating
b) 2.14.1 each 1 1650 1650
(1 No. per phase)

Providing and fixing following rating and breaking


capacity and pole MCCB with thermomagnetic
release and terminal spreaders in existing cubicle
3.07
panel board including drilling holes in cubicle panel,
making connections, etc. as required.

100 A, 16 kA,TPMCCB for (G+IV+1Floor) -UPS &


a) 2.2.1 LDB each 12 3218 38616

b) 2.2.2 125 A, 16 kA,TPMCCB for (G+IV+1Floor) -L DB each 3 3613 10839


150 A, 16 kA,TPMCCB for (G+IV+1Floor) -P DB
c) 2.2.3 each 2 4096 8192
200 A, 25 kA,TPMCCB for (G+IV+1Floor) -P DB
d) 2.2.5 each 4 7964 31856

OT ISOLATION PANEL
Supply only of Indoor, cubical, wall mounted. With
IP 42 protection , 10 KVA ISOLATION
3.08 each 3 419750 1259250
Transformer , single phase 230 Volt air cooled
ISOLATION Panel for OT with following specs

Receiving,installation, testeng ,commisioning of


Indoor, cubical, wall mounted. With IP 42 protection
3.09 , 10 KVA ISOLATION Transformer , single phase each 3 2875 8625
230 Volt air cooled ISOLATION Panel for OT with
following specs

RISING MAIN

Sign and Stamp of EPIL 91 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supplying, installing on wall, testing and
commissioning of following capacity Air Insulated
Compact Type Rising Mains for use on 3 phase 4
wire 415 V, 50Hz A.C. supply with enclosure
having IP-54 rating after fixing the tap off boxes
and all accessories, made of 1.6mm thick steel
sheet duly powder coated in convenient sections
complete with 4 Nos. aluminium bus bars having
3.10 current density of 130 A/ sq cm at nominal
current rating, necessary joints & expansion joints,
fire barrier at each floor, provision of tapping at
every meter, continuous earthing with 2 Nos.
aluminium strip of suitable size (one on each side)
including, G.I. clamping brackets, angle iron
bracket, steel fasteners, connecting to earthing
system etc. as required.

3.8.2 315 A, Isc = 25 kA for 1 second Mtr 21 5806 121926

Supplying, installation, testing & commisioning of


following capacity Plug In/ tap off box on the
existing Air Insulated Compact Type bus trunking/
rising mains for use on 3 phase 4 wire 415 V, 50Hz
3.11
A.C. supply made with 1.6mm thick sheet steel
enclosure (IP54) duly powder coated with provision
of MCCB (but without MCCB) complete etc. as
required
3.12.1 125 A, Isc = 15 kA for 1 second each 6 4621 27726

Supplying, installation, testing & commisioning of


following capacity End Feed Unit for the existing
Air Insulated CompactType bus trunking/ rising
mains for use on 3 phase 4 wire 415V, 50Hz A.C.
supply made with 1.6mm thick steel sheet
3.12 enclosure (IP54) duly powder coated with provision
of MCCB/ ACB (but without MCCB/ACB) complete
with necessary joints including clamping brackets,
angle iron bracket, steel fasteners, connecting to
earthing system etc. as required

3.11.2 315 A, Isc = 25 kA for 1 second Each 1 4169 4169

Providing and fixing following rating and breaking


capacity and pole MCCB with thermomagnetic
release and terminal spreaders in existing cubicle
3.13
panel board including drilling holes in cubicle panel,
making connections, etc. as required.

i) 2.2.18 400 A, 50kA, FP MCCB for EFU Each 1 19089 19089


ii) 2.2.13 100 A, 30kA, FP MCCB for tap off box Each 6 5360 32160

Total carried over to summary Rs. 3776689.00

OT ISOLATION PANEL-SPECIFICATION
1) SYSTEM 230V AC 50Hz Single Phase
2) LOCATION & TYPE Indoor, cubical, wall mounted.
3) ENCLOUSRE IP42
4) ISOLATION PANEL
a) Isolation transformer capacity 10 KVA-PIECO MAKE.
b) Ratio 0.042361
c) Primary Voltage (Volts) 230V
d) Secondary Voltage (Volts) 230V

Sign and Stamp of EPIL 92 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
e) Cooling Air Cooled
f) Winding & type Cooper winding Double wound with
5) OVERALL DIMENSION 1150mm H X 650mm W X 250mm D
6) INCOMER
a) ELCB HI Type 63A 30 mA. DP –Schneider/Siemens make
b) MCB D Curve 63A DP – Schneider/Siemens make
7) OUTGOING
MCB D Curve 12 Nos. 20A DP – Schneider/Siemens make
8) LINE ISOLATION MONITOR Hazard Index 0-10MA. - PIECO MAKE
9) INDICATION
a) Meter Digital – PIECO MAKE
b) Indicating Lamp Red & Green for Zones
10) COOLING FAN 230V 4 inches

SUB HEAD-IV ERRECTION OF LIGHT & FAN FIXTURES

Supplying and fixing brass batten/ angle holder


4.01 1.34 each 3 75 225
including connection etc. as required.

Supplying and fixing of 3 pin, 5 amp ceiling rose ISI


4.02 1.33 marked on the existing junction box / wooden block each 33 46 1518
including connection etc. as required.

Supplying and fixing call bell/ buzzer suitable for


4.03 1.38 single phase,230 volts, complete as required. For each 72 61 4392
consultant -disply board

Providing and fixing plain 16/0.20mm (0.50sqmm)


twin flat flexible,FRLS PVC insulated, copper
4.04 1.39 cable, in PVC sleeve of suitable size on the floor/ Mtr 1975 22 43450
wall, or side of the table/ door etc. as required.

Installation, testing and commissioning of LED Light


Fixture & Exit Light with 1.5 sq. mm FRLS PVC
4.05 1.41 each 2140 100 214000
insulated, copper conductor, single core cable and
earthing etc. as required.

Installation, testing and commissioning of ceiling


fan, including wiring the down rods of standard
length (upto 30 cm) with 1.5 sq.mm FRLS PVC
4.06 1.45 insulated, copper conductor, single core each 390 132 51480
cable,including providing and fixing phenolic
laminated sheet cover on the fan box etc. as
required.

FIXING EXHAUST FAN UPTO 450 MM SWEEP

Installation, testing and commissioning of exhaust


fan up to 450 mm sweep in the existing
opening,including making the hole to suit the size of
4.07 1.50.1 each 34 224 7616
the above fan, making good the damage complete
, connection , etc as required.-M/C ROOM &
PUMP ROOM

Extra for fixing of louvers / shutters complete with


4.08 1.5.1 each 34 99 3366
frame for exhust fan of all sizes.

Total carried over to summary Rs. 326047.00

SUB HEAD-V SUPPLY OF LIGHT & FAN FIXTURES

Sign and Stamp of EPIL 93 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
20W LED tubelight -similar to philips cat no-
5.01 N.S.R. each 410 1537 630170
BN150W LED20S-6500 PSE OD GR

18W LED tubelight with cover -similar to philips cat


5.02 N.S.R. each 253 507 128271
no-BN021C LED20S PSU CDL GR

15 W surface type LED downlighter -similar to


5.03 N.S.R. philips cat no-DN194B LED15S-6500 PSU WH S1 each 174 1220 212280

18W recessed type LED downlighter -similar to


5.04 N.S.R. philips cat no-DN194B LED15S-6500 PSU WH S1 each 560 1510 845600

20 W recessed type LED downlighter -similar to


5.05 N.S.R. philips cat no-DN195B LED20S-6500 PSU WH S1 each 5 1801 9005

36 W 600mmX600mm LED Light (for minor OT) -


5.06 N.S.R. similar to philips cat no-RC383B LED 36S-4000 each 6 3226 19356
PSU OD WH PIR

40 W 600mmX600mm LED Tile Light -similar to


5.07 N.S.R. philips cat no-RC383B LED 36S-4000 PSU OD WH each 149 3226 480674
PIR

Bulk Head LED Light Surface type -similar to C&S


5.08 N.S.R. each 61 613 37393
cat no-CG80IB6WLED

1200mm long antibacterial UV Light (for blood


5.09 N.S.R. bank) -similar to philips cat no-PHILIPS TUV 36W each 6 1008 6048
+ FITTING

5.10 Supply of following Ceiling Fan :


1200mm Sweep similar to Havells CAT no. - Pacer
a) each 386 1698 655428
1400mm Sweep similar to Havells CAT no. - Pacer
b) each 4 1816 7264

Supply of 380mm Heavy Duty Exhaust Fan for


5.11 Machine Room including louvers similar to Havells each 2 3371 6742
CAT no. - Turbo force

5.12 N.S.R. Supplying of Heavy Duty Exhaust Fans


300 mm, 1400 RPM similar to Havells CAT no. -
Each 32.00 2815.00 90080
turbo force

Supplying and fixing call bell/ buzzer suitable for


5.13 1.38 Each 32.00 61.00 1952
single phase,230 V, complete as required

Decorative wall mounting fixture with opal glass


diffuser suitable for 12W LED Bulb similar to philips
5.14 N.S.R. each 120.00 821.00 98520
for type II+Type III - similar to philips Decorative
light fix. GRACE Wall light

Decorative wall mounting fixture with opal glass


diffuser suitable for 12 W LED Bulb similar to
5.15 N.S.R. each 88.00 1085.00 95480
philips for type IV - Decorative light fix. EWC 300
WHIT

Supply of 10W round shaped surface mounted LED


5.16 N.S.R. slim panel, powder coated white finish each 145.00 930.00 134850
housing.similar to polycab cat no PCGLWL 10 R -

Sign and Stamp of EPIL 94 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

Supply of 18W round shaped surface mounted LED


5.17 N.S.R. slim panel, powder coated white finish each 40.00 1563.00 62520
housing.similar to polycab cat no PCGLWL 18 R -

Supply of surface & wall mounted 20 watt LED


TUBE LIGHT with extruded aluminium housing and
5.18 N.S.R. Each 127.00 507.00 64389
robust construction. Similar to philips BN021C
LED20S PSU NW GR

Total carried over to summary Rs. 3586022.00

SUBHEAD VI :- EARTHING

Earthing with G.I. earth plate 600 mm X 600 mm X


6 mm thick including accessories, and providing
masonry enclosure with cover plate having locking
6.01 5.4 each 42 4327 181734
arrangement and watering pipe of 2.7 meter long
etc. with charcoal/ coke and salt as required.

Earthing with copper earth plate 600 mm X 600


mm X 3 mm thick including accessories, and
providing masonry enclosure with cover plate
6.02 5.6 each 48 8289 397872
having locking arrangement and watering pipe of
2.7 meter long etc. with charcoal/ coke and salt as
required.

Supplying and laying 25 mm X 5 mm G.I strip at


0.50 metre below ground as strip earth electrode,
including connection/ terminating with G.I. nut, bolt,
6.03 5.9 spring, washer etc. as required. (Jointing shall be Rmt 260 85 22100
done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)

Supplying and laying 25 mm X 5 mm copper strip at


0.50 metre below ground as strip earth electrode,
including connection/terminating with nut, bolt,
6.04 5.8 spring, washer etc. as required. (Jointing shall be Rmt 240 595 142800
done by overlapping and with 2 sets of brass nut
bolt & spring washer spaced at 50mm)

Supplying and laying 25 mm x 5mm G.I. strip on


6.05 5.15 surface or in recess for connection etc as required. Rmt 1080 129 139320

Providing and fixing 25 mm X 5 mm copper strip on


6.06 5.14 surface or in recess for connections etc. as Rmt 1000 698 698000
required.

Providing and fixing 6 SWG G.I. wire on surface or


6.07 5.16 Rmt 760 37 28120
in recess for loop earthing as required.

Providing and laying earth connection from earth


electrode with 4.00 mm dia copper wire in 15 mm
6.08 5.13 Rmt 200 182 36400
dia G.I. pipe from earth electrode including
connection with copper thimble

Sign and Stamp of EPIL 95 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Providing and fixing 4.00 mm dia copper wire on
surface or in recess for loop earthing along with
6.09 5.19 Rmt 100 73 7300
existing surface/ recessed conduit/ submain wiring/
cable as required.

Providing and fixing earth bus of 50 mm X 5 mm


6.10 5.20 copper strip on surface for connections etc. as Rmt 128 1283 164224
required.

(1.14.5- Supplying and drawing following sizes of FRLS


1.21.2- PVC insulated copper conductor, single core cable
6.11
1.17.2/2) (GREEN Colour ) in the existing surface /
/2 recessed steel / PVC conduit as required.
10 sq. mm green colour Rmt 300 86 25875

Total carried over to summary 1843745.00

SUBHEAD VII :- LIGHTNING ARRESTOR

Providing and fixing of lightning conductor finial,


made of 25 mm dia 300 mm long, G.I. tube, having
7.01 6.2 single prong at top, with 85 mm dia 6 mm thick G.I. each 4 304 1216
base plate including holes etc.complete as
required.

Jointing copper / G.I. tape (with another copper/ G


I tape, base of the finial or any other metallic object)
7.02 6.4 Each 100 57 5700
by riveting / nut bolting / sweating and soldering
etc. as required.

Providing and fixing G.I. tape 20 mm X 3 mm thick


on parapet or on surface of wall for lightning
7.03 6.7 Rmt 250 66 16500
conductor complete as required.(For horizontal run)

Providing and fixing G.I. tape 20 mm X 3 mm thick


7.04 6.8 on parapet or on surface of wall for lightning Rmt 160 100 16000
conductor complete as required. (For vertical run)

Providing and fixing testing joint, made of 20 mm X


3 mm thick G.I. strip, 125 mm long, with 4 Nos. of
7.05 6.12 each 8 73 584
G.I. bolts, nuts, chuck nuts and spring washers etc.
complete as required.

Providing and laying of G.I. tape 32 mm x 6 mm


7.06 6.14 from earth electrode directly in ground as required. Rmt 100 112 11200

Soil Enhancement Material -ADDITIONAL

Total carried over to summary 51200.00

DETAIL OF EARTHING
(HT PANEL) CU 2
TR -N CU 4
DG -N CU 4
LIFT CU 8
OT CU 6
CSSD CU 2
CATH LAB CU 2
OTHER( UPS,SERVER,X-RAY etc) CU 20
TOTAL NOS OF COPPER EARTHING 48

Sign and Stamp of EPIL 96 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
TR -BODY GI 4
2 POLE Structure GI 2
DG- BODY GI 4
PANEL GI 4
BUILDING GI 4
LA GI 8
OTHER GI 10
TOTAL NOS OF GI EARTHING 36

SUBHEAD - VIII . FIRE ALARM & PA SYSTEM


a) Hospital
Supply, installation, testing & commissioning of 4
Loop Microprocessor based inteligent and
electronically addressable, modular, expandable
networkable, Panel (expandable) with each loop
capacity of 250 detectors with Loop length up to 3
KM. Fire alarm control panel with 5.7 inch touch
screen LCD display, multiple acess levels, 10,000
event history logs in the non volatile memory
(EEPROM).The panel should be modular
8.01 microprocessor based in nature and should be Nos. 1 390667.85 390667.85
expandable from single loop to up to 32 loops. The
panel shall have 240V AC power supply, Automatic
battery charger, 24V , ceiled lead acid maintanence
free battries sufficient for 24 hours normal working
and then be capable of operating the system for 30
mins during emergency condtion. Panel shall be
integratable to BMS Backnet software. The panel
shall be EN54/Vds /ULCertification.

supply, Installation, connecting testing and


commissioing of Active and networkable repeater
panel with LCD display complete system function
8.02 Nos. 1 114369.65 114369.65
keys for programming and control like system reset,
alarm acknowledgement, alarm silence, trouble
acknowledgement ...etc. as per specification.

8.03 Supply, Installation, Testing and Commissioning of addressable


Nos. smoke
300detector4366.78
including mounting
1310034base with LED… etc. complet

Supply, Installation, Testing and Commissioning of


addressable Heat detector withfiexed and rate of
raise feature including mounting base with LED…
etc. complete as required with 2 Isolators (one for
incoming and one for outgoing line) integrated in
detector for maintaining operational availability of
8.04 Nos. 10 4267.12 42671.2
all elements in the loop, even in the event of a short
circuit, & Drift Compensation feature & Automatic
addressing. High resistance to electromagnetic
effects in accordance with EFSG agreement
EFSG/F/97/005. Shall be EN54/ VDs/UL
certification. Make : Bosch

Supply, Installation, Testing and Commissioning of


addessable manual break glass unit ( Double
8.05 action) with flexible network structures & necessary Nos. 26 4040.63 105056.38
fixing arrangements with key complete as required.
Shall be EN 54 / Vds/UL Certification. Make: Bosch

Sign and Stamp of EPIL 97 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supply, Installation, Testing and Commissioning of
Addressable Monitor Module with 3 monitoring
8.06 features, monitoring of a line with EOL resistor Nos. 31 5290.86 164016.66
,Potential free contact & voltage monitoring. Shall
be EN54 / Vds/UL Certification. Make : Bosch

Supply, Installation, Testing and Commissioning of


Addressable Control Relay Module with flexible
8.07 network structures with a maximun switching Nos. 31 5290.86 164016.66
current of 1A @ 30V DC. Shall be EN54/ Vds
Certification/UL Make : Bosch

Supply,installation,Testing and commissioning of


Responce Indicator Alarm status is indicated By
Red colour LED, Operates on 12 VDC, Dual LED’s
8.08 for 360deg visibility, Flush / Ceiling wall mount, Nos. 100 1041.87 104187
Operating Voltage : 12 VD.C, Operating Current :
10mA, Alarm Indication : RED LED with required
accessories

Supply, Installation, Testing and Commissioning of


Stand alone Loop Powered detector base sounder
with 32 different tone variants selection options &
adjustable sound pressure by 5 levels, the sound
8.09 Nos. 1 10251.05 10251.05
pressure 92.1 dB(A), with flasher having
Synchronized flash rate of 1 Hz and Light intensity
> 2 cd, should be programmed from the panel.
Shall be EN54 / Vds/UL Certification.

Supply,Installation,Testing and Commissioning of


Voice Alarm Call Station having gooseneck
condenser microphone with 6 zone Selection Keys
and an All-Call-Key, PTT Switch, selectable gain,
8.10 speech filter and limiter for improved intelligibility, Nos. 1 29398.73 29398.73
LED indication for zone selection, fault and
emergncy state, Complete as required (Similar to
Bosch Cat. No. LBB 1956 or equivalent)

Supply,Installation,Testing and Commissioning of


Voice Alarm Controller having features like
announcement to 6 zones expandable to 60 zones,
built in 240W booster amplifier, emergency
microphone on the front panel, 16 priority levels
including emergency, music to selected zones can
8.11 be played, upto 255 messages can be stored in the Nos. 1 195336.19 195336.192
internal 16MB flash ROM, individual BGM volume
control for each zone, Digital pre-recorded
messages can be merged, full system supervision,
Complete as required (Similar to Bosch Cat. No.
LBB 1990 or equivalent)

Supply,Installation,Testing and Commissioning of


Ceiling/wall mounted 6 watt speaker with line
8.12 matching transformer as per specification, Nos. 137 1019.22 139632.592
Complete as required (Similar to Bosch LBD
0606).

8.13 SITC of 12 W Box Speaker Nos. 5 2134.69 10673.45

Sign and Stamp of EPIL 98 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
8.14 SITC of Plena Booster Amplifier 480 W Nos. 4 42435 169740

SITC of CALL/PAGING Station Set of 6 zone


8.15 Nos. 1 126787.5 126787.5
paging controller with set of 4 keypad

8.16 SITC of 240 RMS mixer amplifier Nos. 1 25228.13 25228.13

8.17 SITC of 6 zone router Nos. 4 109968.75 439875

8.18 SITC of 15 U Rack with Accessories Nos. 1 20053.13 20053.13

8.19 SITC of XLR Connectors for paging stations Nos. 8 582.19 4657.52

Supplying and fixing of following sizes of steel


conduit along with the accessories in
surface/recess including painting in case of surface
8.20
conduit or cutting the Wall and making good the
same in case of recessed conduit as required.

1.20.2 25 mm dia Rmt 4800 147 705600


Supplying, Laying and fixing following sizes PVC
insulated / PVC Sheathed XLPE ISI marked
8.21
unarmoured copper conductor cable of 1.1 KV
grade on surface of Wall/Ceiling as reqd

a) 2 x 1.5 sqmm Rmt 3500 77.0075 269526.25

Supply and Laying 2 core 24/.2 mm PVC insulated


8.22 twisted copper conductor wires in existing conduit/ Rmt 2500 58.8881 147220.25
trunking as required.

Supply of Glow Type EXIT Sign Board photo


luminescent of size 300 mm x 250 mm x 1.5 mm
rigid sheet signage containing Zink Sulphate as
bare chemical class – 1 material PSPA fixed on 3
mm acrylic sheet on both side showing marking
8.23 (running man, Arrow and Exit) and hanged with the Nos. 43 2772.27 119207.524
ceiling with chain and fastener including cost of
labour & material required to complete the job in all
respect up to the entire satisfaction of Engineer-in-
Charge of work.

Total carried over to summary ₹ 4808206.7

SUBHEAD - IX . CCTV SYSTEM

SITC of 1/3" Super HAD CCD Colour Dome Fixed


Camera 650TVL, 0.1 Lux, 3.6/4/6/8 mm DC12V, -
10 deg. C to 50 deg.C, Auto White Balance
9.01 (AWB), Back Light Compensation (BLC), 2D DNR, 58 5977.7 346706.6
OSD, suitable for indoor application, 3 Years
Warranty, UL Listed, Inclusive of Taxes .
Nos

SITC of 1/3" Super HAD CCD Colour Dome


Varifocal Camera 650TVL, 0.0001 Lux, 2.8-11 mm
varifocal, DC12V, -10 deg. C to 50 deg.C, Auto
IRIS, Automatic Gain Control (AGC), Auto White
9.02 1 9462.2 9462.2
Balance (AWB), Back Light Compensation (BLC),
2D + 3D DNR, suitable for indoor application, 3
Years Warranty, UL Listed, Inclusive of Taxes .
Nos

Sign and Stamp of EPIL 99 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

SITC of 1/3” Super HAD IR Dome Fixed Camera ,


650 TVL, 0.5 LUX/F2.0 (0 Lux IR On), AWB, 20
meter IR, DC12V -10 deg. C to 50 deg.C, Auto
9.03 5 8068.4 40342
White Balance (AWB), Back Light Compensation
(BLC),2D DNR, IP 66, 3 Years Warranty, UL Listed
, Inclusive of Taxes. Nos

SITC of 1/4" CCD,High Speed Dome PTZ Camera,


6000TVL, 0.003 lux; 0.000001lux(B/W), 37x Optical
Zoom, Automatic Gain Control (AGC), IR Cut Filter,
Back Light Compensation (BLC), Automatic White
Balance (AWB), Auto IRIS, 360 Degree endless
9.04 Pan Travel, 0 Degree to 180 degree tilt, 3D DNR, 1 91114.5 91114.5
WDR, ICR D/N, 256 presets, 3.5 - 129.5 mm lens
for outdoor application, Auto Tracking, 3 Years
Warranty, UL Listed , Inclusive of Taxes.
Nos
11
SITC of 16-Channel NVR(16Ch@1080P NVR, 2
9.05 7 79927.875 559495.125
HDDs, 1x1000M Port, 16 POE Ports, PAL) Nos

9.06 SITC of HDD Surveillance 4 TB Nos 12 17983.125 215797.5

SITC of Gigabit stackeable managed switch with 24-


9.07 port 10/100/1000. Model No: SG300-24PP (CISCO 2 63005.625 126011.25
Make) Nos

9.08 SITC of Rack & Accessories :


a 9U rack including PDU (5 Socket) Nos 3 8797.5 26392.5
b 1U MS cable manager Nos 5 355.781 1778.905
c Mounting Hardware (10 pieces) Nos 10 258.75 2587.5

9.09 SITC of Pasive Component & Accessories :


a Cat-6 patch cord 1m Nos 95 420.469 39944.555
b Cat-6 Patch panel Nos 4 5821.88 23287.52
c RJ-45 connector Nos 1 2328.75 2328.75

9.10 22" TFT Colour Monitor as per specifications. Nos 17 8738.65 148557.05

Supply and Surface Laying of RG11 Co-axial Video


9.11 1950 81.0175 157984.125
cable in PVC conduit. Mtrs

Supply and Laying of 2 Core x 1.0 sq.mm


9.12 unarmoured PVC Sheathed, AneAled Tinned 1560 75.21 117327.6
Copper, Power Cable. IN pvc conduit Mtrs

Power Supply for Cameras 12 V DC ( Procure


9.13 64 754.975 48318.4
Locally) Nos

Power Supply for PTZ cameras 24 V AC (Procure


9.14 1 1452 1452
Locally) Nos

Supply and Surface laying of 2 Core 1 sqmm


9.15 300 81.02 24306
flexiable shielded data cable in PVC conduit. Mtrs

Total carried over to summary ₹ 1983194

SUBHEAD - X . NURSE CALL SYSTEM

Sign and Stamp of EPIL 100 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
10.01 Supplying, fixing testing and commissioning of
modular nurses station LED type terminal monitor
with in built display & alarm, suitable for following
way complete with back up, batteries, battery
charger etc. as per technical specifications and as
required.
i) 30 Way Each 7 58995 412965

10.02 Supplying, fixing testing and commissioning of call


a) push button (with cord), call reset, call indication
Each 184 3933 723672
station for each bed complete as required.

10.02 Toilet Pull Cord Unit


Each 10 4301.7188 43017.1875
b)

10.03 Supply and drawing 0.61, 3 pair PVC insulated


Cable in existing MS Conduit on recessed complete Metre 5820 86.0344 500720.208
as required

10.04 1.20.2 Supplying and fixing of following sizes of steel


conduit along with accessories in surface/recess
including painting in case of surface conduit, or Metre 3492 147 513324
cutting the wall and making good the same in case
of recessed conduit as required. 25 mm Dia

10.05 Supplying, fixing testing and commissioning of


Each 20 1536.3281 30726.5625
LED's Indicators outside each ward

Total carried over to summary ₹ 2224425

SUBHEAD - XI . Local Area Network (LAN)

SITC of Structured cabling for Data, wireless and


voice

11.01 Supplying and fixing following size/ modules, GI


box alongwith modular base & cover plate for
modular switches in recess etc. as required.
1.27.2 3 Module (100 mmX75 mm) for existing RJ 45 each 182 185 33670

11.02 Cat-6 components


a Cat-6 I/O (Data) No/s 200 226.4 45280
b Face Plate - (D) No/s 182 109.97 20014.54
c Cat-6 utp patch cord 1m No/s 160 200.53 32084.8
d Cat-6 utp patch cord 2m No/s 170 213.47 36289.9
e Cat-6 24-port patch panel No/s 14 6210 86940

11.03 Network Rack and accessories


a 42U 600x800 network rack with front glass and
back perforated doors, fan tray with four fans and No/s 1 63135 63135
power strip
b PVC cable manager (1U) Horizontal No/s 10 355.78 3557.8
c Mounting Hardware (10 pieces) No/s 25 323.44 8086

11.04 Switching Component/s (hardware)


a Gigabit stackeable managed switch with 24-port
No/s 1 63005.63 63005.63
10/100/1000. Model No: SG500-28
b Gigabit stackeable managed switch with 24-port
No/s 5 32990.63 164953.15
10/100/1000. Model No: SG300-24

Sign and Stamp of EPIL 101 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
11.05 1.53.1 Supplying and drawing of UTP 4 pair CAT 6 LAN
Cable in the existing surface/ recessed steel/ PVC mtr. 12200 34 414800
conduit as required.

Total carried over to summary ₹ 971817

SUBHEAD - XII . EPABX

Supply, Installation, Testing & commisioning of


following :

12.01 Progility IP PBX “HP 256 T+” System


Supports 14 universal slots and 2 dedicated slots
for PRI/VoIP
Progility HP 256 T+
Expandable System support up to 224 TDM & 256
IP Users
Supports Standalone as well as Networked
scenarios.
19” Rack mountable
Supports Video Telephony on IP
Supported interfaces:-
Analog Extensions
Digital Extensions
SIP Extensions (Native SIP)
Analog Trunks
ISDN Trunks
VoIP Trunks (For networking)
Supports 230V AC power supply as well as
provision for -48 V DC
battery back up
Support In-Skin Voicemail with e-mail integration #

Support In-Skin Voice recording #


Support Redundancy for control card (No
disconnection of calls in case of failover)
Addition of cards
Inbuilt Music on Hold,
08 Party adhoc Conference
CLIP facility for all offered extension & trunks
Call barring (scheduled/Manual based)
Busy call back,
Boss/Secretary feature
Night Service/ Day Service
Analog Extension with CLIP : 104 Nos
Digital Extension : 08 Nos
Analog Trunk Lines : 08 Nos
PRI Line 30 Chs : 01 Nos
In-built IVR for incoming PSTN (Analog & PRI) lines

Supports multi-level tree structures


Simultaneous 32 calls can be handled

12.02 Operator Consol (8150 with DSS 64) (price


inclusive)
Display : 2 Lines Backlit, 16*2 Characters, Key : 16
Fixed
function Keys, Jog Dial, 30 DSS Key, 100 No. of
phone book
entries, Ring Tones : 8 difference ring tones,
Volume

Sign and Stamp of EPIL 102 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
adjustment : 4 Level, Acoustics:- Hands free
talking, DSS 64
Key Module, Support for DSS 64 Key module : Yes,
Name
display of calling party : No
No/s 1 475582.5 475582.5
(item 6.01+6.02)

12.03 Digital Phone 8150 No/s 3 8849.25 26547.75


Display : 2 Lines Backlit, 16*2 Characters,
Key : 16 Fixed function Keys, Jog Dial, 30 DSS
Key,
100 No. of phone book entries,
Ring Tones : 8 difference ring tones,
Volume adjustment : 4 Level
Acoustics:- Hands free talking
Support for DSS 64 Key module : Yes
Name display of calling party : No

12.04 Analog Clip Phone- Progility P100 No/s 170 1164.38 197944.6

12.05 Bittel Uranus Lobby Phone (Fire Communication


No/s 20 3848.91 76978.2
Phone)

Total carried over to summary ₹ 777053

EXTERNAL ELECTRIFICATION

SUBHEAD - XIII HT - 33 kv TWO POLE


STRUCTURE

Supplying of swaged tublear steel poles ( SP-410-


72-13 Mtr) of standerd sizes in cement concrete
foundations 1:3:6 (1 cement :3 coarse sand : 6
graded stone aggregate 20mm nominal size)
including excavation ,back filling,disposal of soil
13.01 N.S.R. and aligning keeping the pole in vertical position Each 2 25609.78 51219.56
with bottom of pole at 1.85mtr.below ground level
on 150mm thick base padding P.C.C. (Pole is to
be used for making D.P. structure for H.T.
tapping point) etc. all as required.(as per
requirement of .S.E.B.)

13.02 a) N.S.R. 33KV Bus Isolator set 1 40145.06 40145.06


13.02 b) N.S.R. 33KV Line Isolator set 1 46374.47 46374.47

Erection of metallic pole of 13 Mtr length in cement


concrete 1:3:6 (1 cement : 3 coarse sand : 6
13.03 11.14 graded stone aggregate 40 mm nominal size) each 2 4688 9376
foundation including excavation and refilling etc. as
required.

Providing and making steel pole collar with cement


concrete (1 cement : 3 coarse sand : 6 stone
aggregate 20 mm) of specified size and shape
13.04 11.16 CUM 0.32 4693 1501.76
including form work, plastering if required, curing
etc. as required. (volume of pole/ pipe not to be
deducted

Sign and Stamp of EPIL 103 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supplying of two lengths of channel iron 100 mm X
50 mm X 6 mm (9.56 kg per meter) double pole
cross arm for three wire 33 kV over head line
conductors complete with through bolts and nuts for
clamping to the poles, 50 mm X 6 mm M.S. flats
13.05 13.21 welded on one side to the channel iron and with set 4 4013 16052
bolts and nuts on the other side for tying the cross
arms together, including drilling holes for insulator
pins/ fittings, bolts, nuts, washers etc. and painting
with primer and finish paint as required.

Supplying and erection of a set of cross bracing


frame work for 33 kV over head line double pole
structure having four members fabricated out of 65
mm X 65 mm X 6 mm angle iron to form a
rectangle of minimum size 2400 mm width X 2800
13.06 13.22 set 2 6027 12054
mm height complete with 50 mm X 6mm M.S. flat
iron clamps, bolts and nuts including drilling holes
for insulator pins, bolts, nuts, washers etc. and
painting with primer and finish paint as required.

Supplying and erection of 33 kV pin insulator


13.07 13.23 complete with large steel head G.I. pin, nuts, set 3 728 2184
washers etc. as required.

Supplying and erection of a set of three 11 kV disc


insulator for 33 kV over head lines with galvanised
13.08 13.24 insulator fittings, ball and socket type and complete set 3 2635 7905
with galvanised strain clamps, bolts, nuts, washers
etc. as required.

Supplying and erection of single piece nonlinear


resistor type lightning arrestor suitable for 3 wire,
33 kV overhead lines with rated voltage 30 kV (rms)
13.09 13.25 with a nominal discharge current rating of 10 kA set 1 18575 18575
(station class) and complete with galvanised
clamping arrangement, G.I. bolts, nuts, washers
etc. as required.

Supplying and erection of galvanised stay set for 33


kV over head lines complete with 19/ 20 mm dia X
1.8 meter long stay rod, anchor plate of size 45 cm
X 45 cm X 7.5 mm thick, thimble, stay clamps, turn
buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay
13.10 13.14 wire and 33 kV strain insulator etc. in cement set 2 3821 7642
concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size)
foundation including excavation and refilling etc. as
required.

Supplying and drawing standard steel


reinforcement aluminum conductor conforming to
IS 398/ 1961 of approved make , stringing on HT
13.11 N.S,R. poles structures including making of complete with
binding jointing, jumpers tearing of connections
atexisting HV insulators with suitable GI hardware
etc. as required.
a) ACSR 3 of 6/7 dog conductor i.e. 6/4.72
kg 60 75 4500
aluminum and 7/1.57mm steel conductor.

Sign and Stamp of EPIL 104 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Total carried over to summary ₹ 217528.85

SUBHEAD XIV :- 33KV SYSTEM

33 KV, H.T. PANEL:( 1 INCOMERS, 1 & 2 NOS


OUTGOINGS)
33 KV Main Panel
Supplying, installation, testing & commissioning of
indoor type floor mounted extendable type, metal
clad, totally enclosed, 3 Panel 33 KV VCB board (1-
Incoming and 2- nos outgoing) single break, trip
free, motorised spring charged wth electrical
closing arrangement with horizontal drawout and
horizontal isolation type VCB with mechanical
ON/OFF indicator and trip device,4 NO + 4 NC
auxilliary contact complete with self contained, fully
14.01 N.S,R. interlocked, rack in and rack out mechanism as per
IS 13118, as amended up to date and additional
specifications, with air insulated encapsulated
copper bus bars of 630 Amps capacity suitable for
use on 33 KV, 3 Phase, 50 Hz AC supply and short
circuit withstand capacity of 25 KA for three
seconds, and bottom entry gland plate suitable for
3 x 240 sqmm. 33 KV XLPE cable.(But without cost
of end termination)

(A) Incoming - 1 No.(Comprising of)


a) 1 No. - 33 KV, 630 Amp VCB with 33 KV / 110V
PT of 100 VA burden and Accuracy Class 1, Shunt
trip Coil suitable for operation on 48 Volt DC.

b) 1 Set - Dual core CTs 100/5/5 A of 15 VA burden


and accuracy Class- 1 for metering and class 5P10
for protection.
c) 1 Set- 0-38 KV Digital Voltmeter with selector
switch and fuses
d) 1No- Local/ Remote selector switch
e) 1No - Trip/ Neutral/ Close switch
f) 1 Set- ON/OFF, Spring Charged LED indication
lamp.
g) 1 No. - Microprocessor based IDMT relay with 3
O/L, 1 E/F element
h) 1 No- Master trip relay
i) 1 No- PT fuse failure relay.
j) 1 No- Trip Circuit supervision relay.
k) Gland plate suitable for 3C x 120 sqmm 33 KV
grade XLPE cable.
(B) Outgoing - 2Nos (each comprising of)
a) 1 No. - 33 KV, 630 Amp VCB with Shunt trip Coil
suitable for operation on 48 Volt DC.
b) 1 Set - Dual core CTs 50/5/5 A of 15 VA burden
and accuracy Class- 1 for metering and class 5P10
for protection.
c) 1No- Local/ Remote selector switch
d) 1No - Trip/ Neutral/ Close switch
e) 1 Set- ON/OFF, Spring Charged LED indication
lamp.
f) 1 No. - Microprocessor based IDMT relay with 3
O/L, 1 E/F element
g) 1 No- Master trip relay
h) 3 Nos- 3 element Aux relay for Buchhotz Alarm &
Trip, Oil Temp Alarm, Winding Temp Alarm, PRV
Trip, MOG Alarm.

Sign and Stamp of EPIL 105 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
i) 1 No- Trip Circuit Supervision Relay.
j) Gland plate suitable for 3c x120 sqmm 33 KV
grade XLPE cable.

(C ) Remote operation panel


Remote operation panel fabricated with 2mm thick
CRCA sheet having three sections ( 1-Incomer, 2-
Out going) provided with
(a) Incoming section: 1 No (comprising of)
i) 1 Set- 0-38 KV Digital Voltmeter with selector
switch and fuses
ii) 1 Set. - 0-100A Digital Ammeter with selector
switch.
iii) 1 No. - Digital multi function meter suitable for
reading Voltage, Current, Power factor, KVA, KW,
KVAR, KWHr, KVAHr
iv) Trip/Neutral/close switch.
v) ON/OFF/ Spring charge LED type Indicating
lamp
vi) Test terminal block
vii) 1 No- 6 Window Annunciation Facia with test,
accept and reset button.
viii) 1 Lot- Instrument Fuses
(b) Outgoing section- 3 nos (Each comprising
of)
i) 1 Set. - 0-100A Digital Ammeter with selector
switch.
ii) Trip/Neutral/close switch.
iii) ON/OFF/ Spring charge Indicating lamp
iv) Test terminal block
v) 1 No- 12 Window Annunciation Facia with test,
accept and reset button.
vi) 1 Lot- Instrument Fuses
Control Supply Voltage:
a) Motor operation, Heater, Panel Illumination Light
: 230V AC
b) Shunt Trip, Closing, Indication & Annunciation
N.S,R. set 1 2648808 2648808.01
: 48 V DC

14.02 N.S,R. 48V, DC Battery Bank (200AH).


Suppy, Installation, Testng and Commissioing of
Lead Acid Battery Bank Type PLANTE having
48Volt cell (24 Nos.) along with connector, link,
insulator and Steel/Wooden Battery shelve. The
following accessories are to be supplied with the
Battery Bank.
a) 2 Set - Rubber Glaves
b) 2 Nos. - 2 Volt measuring Voltmeter
c) 2 Nos. - Hygro meter
d) 2 Sets - Rubber Appron
e) Lot - 40 Lt₹of spare electrolyte in container Set 1 216603 216603

14.03 N.S,R. 48V, DC Battery Charger and DCDB.


Suppy, Installation, Testng and Commissioing of
48V DC Battery charger for the above 48V DC
plante type battery bank,Transformer for Boost and
trickle charging system with indicating, metering
and necessary protective instrument/relays as per
technical specification.
a) 1 No. Ampere - Hour meter has to be included.
b) Battery charger should have a DC Distribution
Board as an integral / separate DB consisting of the
following equipments.

Sign and Stamp of EPIL 106 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
c) 1 - 125A rated DC MCCB as incomer
d) 8 - 20A DP MCB (DC) as outgoing feeder
e) 1 Set - 125A rated DC Busbar (Copper) Set 1 190469 190469

(Transformer)
14.04 1000 KVA transformer with oil soak pit
Making soak pit 2.5 m diameter 3.0 metre deep
with 45 x 45 cm dry brick honey comb shaft with
DSR-14 bricks and S.W. drain pipe 100 mm diameter, 1.8 m
CEVIL_ long complete as per standard design. With Jobs 1 18309.5 18309.5
19.32.1 common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 (The pit shall be adequate to
hold 1000 lt oil).

Supplying installation testing and commissioning of


1000 KVA 33/ 0.433KV, 3 Phase, 50Hz, Dyn l1,
oilcooled ONAN type, copper wound transformer
with ON load tap changing arrangement on HV side
from + 5% to -15% in steps 1.25% along with
remote control panel having cable end boxes on
both sides suitable for 3C x 120 Sq.mm. XLPE
cable on 33KV side and Bus duct on 433V side
complete with buchlotz relay, oil and winding
temperature indicator and alarm contact, PRV,
MOG with all accessories i/c first filling of filtered
14.05 N.S,R. dehydrated oil and confirming to IS 1180 ( STAR-I ) Nos 2 2292813 4585626
including buchholz relay, oil & winding temprature
indicator, marshalling box, interconnections with HT
panel, RTCC panel with Receiving & installation of
copper control cable of size 2.5 Sqmm PVC
armoured Copper cable as required as per
specification. and Including Heat Run Tested as
for real time application.& as per specification
attached complete in all respects on outdoor plinth
as required (to be installed oudoor).
( 1 WORKING +1 STANDBY)

Supply of the following sizes of 33 KV XLPE AL


Earthed armoured cable in cable trenches or in
14.06 NSR ducts over a bed of sand and covering with bricks
as per specifications including excavation of
trenches and back filling complete as required

33 KV, 3C x 120 Sq. mm XLPE Aluminium cable


mtr 30 996.24 29887.2

Laying of one number XLPE power cable of 33 kV


grade of following size direct in ground including
14.07 excavation, sand cushioning, protective covering
and refilling the trench etc. as required.
8.5.1 Upto 120 sq. mm meter 30 275 8250

HV CABLE JOINTING & END TERMINATION

Supplying and making indoor cable end termination


with heat shrinkable jointing kit complete with all
accessories including lugs suitable for following
14.08
size of 3 core, XLPE aluminium conductor cable of
33 kV grade as required.

10.7.2 120 sq. mm each 4 14283 57132

Sign and Stamp of EPIL 107 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supplying and making outdoor cable end
termination with heat shrinkable jointing kit
complete with all accessories including lugs
14.09 10.80
suitable for following size of 3 core, XLPE
aluminium conductor cable of 33 kV grade as
required.
10.8.2 120 sq. mm each 1 18777 18777

Total carried over to summary ₹ 7773861.71

SUBHEAD-XV : SAFETY EQUIPMENT & CABLE


TRAY
15.01 Providing & fixing of SAFETY EQUIPMENT
H.T. (33 KV) DANGER NOTICE PLATE of
250mmx200mm size made of mild steel at least
a) 2.22 2mm thick and vitreous enameled white on both set 6 163 978
sides and with inscription in signal red colour on
front side as required

Providing & fixing M.V. (440 V) Danger notice


plate of 200mmx150mm made of mild steel at least
b) 2.21 2mm thick and vitreous enameled white on both each 10 149 1490
sides and with inscription in signal red colour on
front side as required.

Supply & erection of the following Safety and


testing equipment Including miscellaneous items
15.02 like clamps, nuts & bolts ,rawl plug etc at suitable
places in the substation building as required

G.I.buckets of 3 nos 5 liters capacity duly painted


white inside and red oxide paint out side and
written 'FIRE' with white paint & filled with dry sand
a) and mounted on M.S. angle iron bracket of size set 5 2600 13000
50x50x6mm thick and 1200 mm long including
grouting in wall /floor etc. as required.

First aid box as approved by St.John Ambulance


b) Brigade/Indian Red Cross Society and confirming each 2 410 820
to IS 2217/ 1963.

Shock Treatment chart duly glazed mounted on


c) Aluminum Frame with sheet glass as each 2 509 1018
required.

Providing and laying ISI 5424 marked 20 mm


d) thick nonskid type insulating Rubber mat to sqm 5 2925 14625
withstand 11 KV dielectric strength as required

Providing and laying ISI 5424 marked 12 mm


e) thick nonskid type insulating Rubber mat to sqm 8 1550 12400
withstand 1.1 KV dielectric strength as required

Supplying rubber gloves 11 KV grade as per


f) Pair 2 350 700
I.S. code.

Providing & fixing of M.S. angle iron with fixing


15.03 materials and painting for cable racks in trenches/ Kg 100 65 6500
on walls etc .as required.

Sign and Stamp of EPIL 108 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Providing and fixing of M.S.slotted Angle 'C'
channel/Ladder type rack/Tray i/c fixing materials
grouted in wall or hanging with M.S. rod hanger
15.04 Kg 100 65 6500
from ceiling including 2 coat synthetic enamel
painting over 1 coat of red oxide primer etc. as
required.-

Supplying and installing following size of perforated


painted with powder coating M.S. cable trays with
perforation not more than17.5%, in convenient
15.05 sections, joined with connectors,suspended from
the ceiling with M.S. suspenders including bolts &
nuts, painting suspenders etc. as required.

100 mm width x 50 mm depth x 2 mm thickness


a) 4.1.1 mtr 200 348 69600

150 mm width x 50 mm depth x 1.6 mm thickness


b) 4.1.2 mtr 250 393 98250

300 mm width x 50 mm depth x 1.6 mm thickness


c) 4.1.4 mtr 2000 526 1052000

450 mm width x 50 mm depth x 2.0 mm thickness


d) 4.1.6 mtr 50 782 39100

600 mm width x 50 mm depth x 2.0 mm thickness


e) 4.1.7 mtr 100 950 95000

Total carried over to summary ₹ 1411981

SUBHEAD XVI : MEDIUM VOLTAGE PANEL BOARD

NOTE: ALL ACBs ARE REQUIRED WITH SAFETY


SHUTTER, UNDER VOLTAGE RELEASE /
SHUNT TRIP
General Note for all Panels
The Panels/ Switch-boards shall be fabricated out
of (load bearing member of 2mm and non load
bearing member 1.6 mm thick) CRCA sheet steel,
Compartmentised design, modular construction
with Form 4b separation for Main Panels & 3b for
remaining, Mounting Plates and Internal Partition
shall be made of 1.6/2.0mm Aluzinc sheet for better
Note 1 heat dessipation clear space of 300mm or as
approved shall be left at the bottom.The operating
handle of the topmost switch shall not be higher
than 1800mm from the finished floor and maximum
height of panels shall not more than 2400mm.The
Panel shall be Powder coated to paint of desired
shadend in an approved manner.

Panel Manufacturer must have an established track


Note 2 record in Design, Manufacturing and Supply of IEC
61439 certified Assemblies
Note 3 Undervoltage Relay (27)
Note 4 Reverse power RELAY (32)
Note 5 Inverse Definite minimum time overcurrent relay
Note 6 Overvoltage Relay (59)
Bucholz protection (only transformer switch ) (63)
Note 7
Note 8 Emergency stop on each panel

Sign and Stamp of EPIL 109 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
All incomers and Bus coupler panel door should be
different colour coded for identification and mimic
Note 9
diagram in front of panel should be marks by
reflector paints
All ACB terminals shall have vertical-vertical
configuration for termination of incoming & outgoing
Note 10
bus links. All MCCB’s up to 630A shall be provided
with rear stud type terminations.
Space heater, Thermostat, On/Off switch, LED
Note 11
Lamp , Door operated switch.
Supply, Erection, Testing and commissioning of
Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.01 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted, free standing with compartments in
tier formation, extensible on both sides.The panel
to be provided with PVC Sleeved 4 pole Electrolytic
Al .Maximum Current density for the bus bars shall
meet temp rise condition as per IEC61439. Bus Bar
and PVC insulated solid interconnections and also
provided with 50x6mm. horizontal AL Earth Bus
Bars in each section.(as per drawing- enclosed-
TRF INCOMER:-
2 Nos 1600A FP EDO ACB 50kA With
Microprocessor Based Release (O/C,S/C,E/F)
Protection & S/T(from 1000 KVA transformer
each)
2 Nos Under Voltage Relay (27)
2 Nos Over Voltage Relay (59)
2 Nos IDMT Overcurrent Relay
2 Nos Multifinction Meter With RS-485 port
6 Nos C.T's 1000/5Amp , CL 1.0, 15VA
8 Nos Aux. Contactor
2 Nos Breaker Control Switch
2 Nos A/M Selector switch
2 sets Phase Indicating LED with MCB
2 sets ON,OFF,TRIP Indicating LED
10 Nos Control SP MCB
1 no emergency stop push buttan switch (to control
whole panel)

INTERLOCKING:- (refer SLD)


Electrical & Mechanical Interlocking Between
TRANSFORMER Incomers & BUSCOUPLER

BUSCOUPLER
1 Nos. 1600 A FP EDO ACB 50kA Without release

2 set of ON/OFF indication light


2 No. Breaker Control Switch

Sign and Stamp of EPIL 110 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

BUSBAR :-
2000 Amps 4 pole 50 kA aluminum conductor (
CD 0.8A /sq.mm. ) bus bar (PVC sleeve Heat-
shrinkable busbar insulation) supported by DMC /
FRP insulato₹(MAIN BUSBAR)

OUTGOING
1-All MCCB should be Adjustable thermal magnetic
Release ,Ics=100%Icu with Rotary Handle. Fault
Level minimum 25KA
1-ON Indication Light for all Outgoings. With MCB

L.H.S.

1 No. 500Amps TPN ,MCCB adjustable with rotary


handle for 206 KVAr capacitor panel no-1)

1 Nos 1000A FP EDO ACB 50kA With


Microprocessor Based Release (O/C,S/C,E/F)
Protection & S/T(for Essential panel )
3 Nos. 200Amps FP ,MCCB adjustable with rotary
handle for Ground Floor P.DB, First Floor P.DB,
Spare
2 Nos. 160Amps FP ,MCCB adjustable with rotary
handle for Second Floor P.DB, Spare
2 No. 100Amps FP ,MCCB adjustable with rotary
handle for Spare

4 Nos. 200Amps FP ,MCCB adjustable with rotary


handle for Ground Floor P.DB, First Floor P.DB,
Fourth Floor P.DB, Spare
3 Nos. 160Amps FP ,MCCB adjustable with rotary
handle for Second Floor P.DB, Third Floor
P.DB, Spare

R.H.S.
1 No.630A FP EDO ACB 50kA With Thermal
Magnetic Based Release (O/C,S/C,E/F) Protection
& S/T(for Essential panel )
2 Nos. 320Amps FP ,MCCB adjustable with rotary
handle for 130KVAR, Spare
1 Nos. 200Amps FP ,MCCB adjustable with rotary
handle Fourth Floor P.DB
1 Nos. 160Amps FP ,MCCB adjustable with rotary
handle for Third Floor P.DB
1Nos. 100Amps FP ,MCCB adjustable with rotary
handle for Spare
1 Nos. 63Amps FP ,MCCB adjustable with rotary
handle for Spare

Sign and Stamp of EPIL 111 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
2 nos. of Type 1/Class I surge protection:
According to IEC 61643-1, IEC 62305, IEC 61312-
1; Type 1/Class I encapsulated spark gap
technology surge protection device at the main
incomer LT panel after the breaker in parallel to the
load with the following technical paramete₹03
numbers of 50 KA (10/350 micro sec) to be
connected between each phase & neutral (R,Y,B &
N) and 01 number of 100 KA (10/350 micro sec) to
be connected between neutral & earth with a
voltage protection level of less than 1300 volts, with
the response time of 100 nano seconds. Back-up
tripping provision of 63A MCB in series (in parallel
to the load) with the spd (to be connected before
the spd) to break incase of any abnormal failure of
the spd.
Miscellaneous items
10 nos door switch
10 nos illumination lights with 6 A,10kA MCB
ILLUMINATION LED WITH HOLDER & DOOR
SWITCH
4 nos 6" dia exhaust fan with thermostate &
suitable canopy
Internal illumination in Cable alleys with Door
set 1 3611317.4 3611317.4
operated switch.

Supply, Erection, Testing and commissioning of


Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.02 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted, free standing with compartments in
tier formation, extensible on both sides.The panel
to be provided with PVC Sleeved 4 pole Electrolytic
Al .Maximum Current density for the bus bars shall
be meet temp rise condition as per IEC61439. Bus
Bar and PVC insulated solid interconnections and
also provided with 50x6mm. horizontal AL Earth
Bus Bars in each section.(as per drawing-
INCOMER:-
1 No630A FP EDO ACB 50kA With Microprocessor
Based Release (O/C,S/C,E/F) Protection &
S/T(from Main Panel)
1 No 1000A FP EDO ACB 50kA With
Microprocessor Based Release (O/C,S/C,E/F)
Protection & S/T(from Main Panel)
2 Nos Under Voltage Relay (27)
2 Nos Over Voltage Relay (59)
2 Nos Multifinction Meter With RS-485 port
3 Nos C.T's 630/5Amp , CL 1.0, 15VA

Sign and Stamp of EPIL 112 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
3 Nos C.T's 1000/5Amp , CL 1.0, 15VA
4 Nos Aux. Contactor
2 Nos Breaker Control Switch
2 Nos A/M Selector switch
2 sets Phase Indicating LED with MCB
2 sets ON,OFF,TRIP Indicating LED
10 Nos Control SP MCB
1 no emergency stop push buttan switch (to control
whole panel)
DG Section - Incomer (500KVA)
1 No. 800A FP EDO ACB 50kA With
Microprocessor Based Release (O/C,S/C,E/F)
Protection & S/T (from 500KVA DG)
1 No. Reverse Power Relay
1 No. Under Voltage Relay (27)
1 No. Over Voltage Relay (59)
1 No. Multifinction Meter With RS-485 port
3 Nos C.T's 800/5Amp , CL 1.0, 15VA
1 No. Breaker Control Switch
1 No. 8 Window Annunciator
1 No. Hooter
1 Nos A/M Selector switch
1 set Phase Indicating LED with MCB
1 set ON,OFF,TRIP Indicating LED
15 Nos Control SP MCB

DG Section - Incomer (250KVA)


1 No. 630A FP EDO ACB 50kA With
Microprocessor Based Release (O/C,S/C,E/F)
Protection & S/T(from 250KVA DG)
1 No. Reverse Power Relay
1 No. Under Voltage Relay (27)
1 No. Over Voltage Relay (59)
1 No. Multifinction Meter With RS-485 port
3 Nos C.T's 600/5Amp , CL 1.0, 15VA
1 No. Breaker Control Switch
1 No. 8 Window Annunciator
1 No. Hooter
1 Nos A/M Selector switch
1 set Phase Indicating LED
1 set ON,OFF,TRIP Indicating LED
15 Nos Control SP MCB

INTERLOCKING:- (refer SLD)


Electrical & Mechanical Interlocking Between
Incomer from Main Panels & DG Incomers &
BUSCOUPLER

BUSCOUPLER
1 No. 1000A FP EDO ACB 50kA With
Microprocessor Based Release without proection

1 set of ON/OFF indication light


1 No. Breaker Control Switch
BUSBAR :-
1250 Amps 4 pole 50 kA aluminum conductor (
CD 0.8A /sq.mm. ) bus bar (PVC sleeve Heat-
shrinkable busbar insulation) supported by DMC /
FRP insulato₹(MAIN BUSBAR)

OUTGOING

Sign and Stamp of EPIL 113 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
1-All MCCB should be Adjustable thermal magnetic
Release ,Ics=100%Icu with Rotary Handle. Fault
Level minimum 25KA
1-ON Indication Light for all Outgoings.
L.H.S.

1 No. 800A FP EDO ACB 50kA With Thermal


Magnetic Based Release (O/C,S/C,E/F) Protection
& S/T(for AC Panel)
2 No. 400Amps FP ,MCCB adjustable with rotary
handle for UPS Panel + CATH LAB
2 Nos. 320Amps FP ,MCCB adjustable with rotary
handle for CT SCAN, spare
4 No. 250Amps FP ,MCCB adjustable with rotary
handle for CSSD+MRI+GFL Medical panel+
1 No. 200Amps FP ,MCCB adjustable with rotary
handle for Ventilation Panel
1 Nos. 160Amps FP ,MCCB adjustable with rotary
handle for F FL Medical Panel
1 No 125Amps FP ,MCCB adjustable with rotary
handle for Kitchen Panel
2 Nos. 100Amps FP ,MCCB adjustable with rotary
handle for Spare, Medical Gas Panel
R.H.S.

1 Nos. 400Amps FP ,MCCB adjustable with rotary


handle for UPS Panel
1 No. 320Amps FP ,MCCB adjustable with rotary
handle for Rising Main
1 Nos. 250Amps FP ,MCCB adjustable with rotary
handle for Fire Panel,
2 No. 200Amps FP ,MCCB adjustable with rotary
handle for Pump Panel , Solar
3 Nos. 100Amps FP ,MCCB adjustable with rotary
handle for Spare+ LAUNDRY
3 Nos 63Amps FP ,MCB adjustable with rotary
handle for Lift-1&2,Lift-3&4, Spare
1 Nos 40Amps FP ,MCCB adjustable with rotary
handle for External Lighting
2 nos. of Type 1/Class I surge protection:
According to IEC 61643-1, IEC 62305, IEC 61312-
1; Type 1/Class I encapsulated spark gap
technology surge protection device at the main
incomer LT panel after the breaker in parallel to the
load with the following technical paramete₹03
numbers of 50 KA (10/350 micro sec) to be
connected between each phase & neutral (R,Y,B &
N) and 01 number of 100 KA (10/350 micro sec) to
be connected between neutral & earth with a
voltage protection level of less than 1300 volts, with
the response time of 100 nano seconds. Back-up
tripping provision of 63A MCB in series (in parallel
to the load) with the spd (to be connected before
the spd) to break incase of any abnormal failure of
the spd.
Battery Charger for each DG incomer
230 V, Single Phase, 50 HZ, AC operated Battery
Charger for DC supply to DG Batteries with Boost
and trickle charging facility and protection from over
charging the D.G. set starting battery and a DC DB
with required numbers of outgoing DP MCB's plus 2
Nos. of 15 AMP. DP MCB's as spare feeders.

Sign and Stamp of EPIL 114 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Miscellaneous items
10 nos door switch

10 nos illumination lights with 6 A,10kA MCB


ILLUMINATION LED WITH HOLDER & DOOR
SWITCH
4 nos 6" dia exhaust fan with thermostate &
suitable canopy
Internal illumination in Cable alleys with Door
set 1 4270322.6 4270322.6
operated switch.

Supply, Erection, Testing and commissioning of


Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.03 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation The cubicle should be front operated,
wall mounted,compartments in tier formation,
extensible on both sides.The panel to be provided
with PVC Sleeved 4 pole Electrolytic Al .Maximum
Current density for the bus bars shall be meet temp
rise condition as per IEC61439.Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
each section.(as per drawing- enclosed)) -
INCOMER

1 No. 500Amps TPN ,MCCB adjustable with rotary


handle from Main Panel
1 set of Phase Indication LED lights each backed
up with 6amp. MCB
1 no Digital VIF METER with class-1 accuracy
1 no- RMI-8 APFC Microprocessor based Relay
intelligent type relay setting 0.8 to 0.98 power
factor) for capacitor bank .built in PF meter
suitable contactor for above
3 nos CT's 500/5A class-1(15VA)
5 nos 6 amp SP MCB
1no 6 amp DP MCB
1 no Timer on delay (series 175) 220V AC
Auto / Manual selector switch (3P,2 way with OFF)

1 No Thermostat(30-80 degree)
1 No. Aux. Contactor 8NO+8NC (220V AC)
2 Nos. Aux. Contactor 4NO (220V AC)
2 nos Axial flow fan- 6" ( Heavy Duty)

OUTGOING
7 sets of ON -OFF push buttons station red &
green with ON/OFF indicating lights for each
i)
KVAR capacitor unit to indicate its position.(two
space only)

Sign and Stamp of EPIL 115 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
7 nos Ammeter suitable for each capacitor Bank
ii)
with CT
iii) 1 nos 32 amp TP 10 KA MCB for 12.5 KVAr
iv) 1 nos 40 amp TP 10 KA MCB for 20 KVAr
iv) 3 nos 63 amp TP 10 KA MCB for 25 KVAr
v) 2 nos 100 amp TP 25 KA MCCB for 50 KVAr
1 nos. Capacitor duty contactor suitable rating for
vi)
12.5kVAR Rating
1 nos Capacitor duty contactor suitable rating for 20
vii)
kVAR Rating
3 nos. Capacitor duty contactor suitable rating for
viii)
25kVAR Rating
2 nos. Capacitor duty contactor suitable rating for
ix)
50kVAR Rating
1 nos. 12.5 KVAR, 415 V, MPP supper heavy duty
x) type capacitor bank with 7% detuned reactor
1 nos. 20 KVAR, 415 V, MPP supper heavy duty
xi)
type capacitor bank with 7% detuned reactor
3 nos. 25 KVAR, 415 V, MPP supper heavy duty
xii)
type capacitor bank with 7% detuned reactor
2 nos. 50 KVAR, 415 V, MPP supper heavy duty
xiii)
type capacitor bank with 7% detuned reactor
Miscellaneous items
a 4nos door switch
b 4 nos illumination lights with 6 A,10kA MCB
ILLUMINATION LED WITH HOLDER & DOOR
c
SWITCH
4 nos 6" dia exhaust fan with thermostate &
d
suitable canopy
Internal illumination in Cable alleys with Door
e Each 1 630323 630323
operated switch.

Supply, Erection, Testing and commissioning of


Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.04 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation The cubicle should be front operated,
wall mounted,compartments in tier formation,
extensible on both sides.The panel to be provided
with PVC Sleeved 4 pole Electrolytic Al .Maximum
Current density for the bus bars shall be meet temp
rise condition. Bus Bar and PVC insulated solid
interconnections and also provided with 50x6mm.
horizontal AL Earth Bus Bars in each section.(as
per drawing- enclosed)) -Capacitor Panel-2 ., (as
INCOMER
1 No. 320Amps TPN ,MCCB adjustable with rotary
handle from Main Panel
1 set of Phase Indication LED lights each backed
up with 6amp. MCB
1 no Digital VIF METER with class-1 accuracy

Sign and Stamp of EPIL 116 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
1 no- RMI-8 APFC Microprocessor based Relay
intelligent type relay setting 0.8 to 0.98 power
factor) for capacitor bank .built in PF meter
suitable contactor for above
3 nos CT's 300/5A class-1(15VA)

5 nos 6 amp SP MCB


1no 6 amp DP MCB
1 no Timer on delay (series 175) 220V AC
Auto / Manual selector switch (3P,2 way with OFF)

1 No Thermostat(30-80 degree)
1 No. Aux. Contactor 8NO+8NC (220V AC)
2 Nos. Aux. Contactor 4NO (220V AC)
2 nos Axial flow fan- 6" ( Heavy Duty)

OUTGOING
6 sets of ON -OFF push buttons station red &
green with ON/OFF indicating lights for each
i)
KVAR capacitor unit to indicate its position.(two
space only)
6 nos Ammeter suitable for each capacitor Bank
ii)
with CT
1 nos 25 amp TP 10 KA MCB for 10 KVAr
iii) 2 nos 32 amp TP 10 KA MCB for 12.5 KVAr
iv) 1 nos 40 amp TP 10 KA MCB for 20 KVAr
iv) 1 nos 63 amp TP 10 KA MCB for 25 KVAr
v) 2 nos 100 amp TP 25 KA MCCB for 50 KVAr
1 nos. Capacitor duty contactor suitable rating for
vi)
10kVAR Rating
2 nos. Capacitor duty contactor suitable rating for
vii)
12.5kVAR Rating
1 nos Capacitor duty contactor suitable rating for 20
viii)
kVAR Rating
1 nos. Capacitor duty contactor suitable rating for
ix)
25kVAR Rating
1 nos. Capacitor duty contactor suitable rating for
x)
50kVAR Rating
1 nos. 10 KVAR, 415 V, MPP supper heavy duty
xi)
type capacitor bank with 7% detuned reactor
2 nos. 12.5 KVAR, 415 V, MPP supper heavy duty
xii) type capacitor bank with 7% detuned reactor
1 nos. 20 KVAR, 415 V, MPP supper heavy duty
xiii)
type capacitor bank with 7% detuned reactor
1 nos. 25 KVAR, 415 V, MPP supper heavy duty
xiv)
type capacitor bank with 7% detuned reactor
1 nos. 50 KVAR, 415 V, MPP supper heavy duty
xv)
type capacitor bank with 7% detuned reactor
Miscellaneous items
a 4nos door switch
b 4 nos illumination lights with 6 A,10kA MCB
ILLUMINATION LED WITH HOLDER & DOOR
c
SWITCH
4 nos 6" dia exhaust fan with thermostate &
d
suitable canopy
Internal illumination in Cable alleys with Door
e Each 1 455029 455029
operated switch.

Sign and Stamp of EPIL 117 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supply, Erection, Testing and commissioning of
Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in cubicle
compartmentised modular 4b construction for Main
16.05 N.S.R. Panels & 3b for remaining, Mounting Plates and all
Internal Partition shall be made of 1.6/2.0mm
Aluzinc sheet for better heat dessipation. The
cubicle should be front operated, wall
mounted,compartments in tier formation, extensible
on both sides.The panel to be provided with PVC
Sleeved 4 pole Electrolytic Al .Maximum Current
density for the bus bars shall be meet temp rise
condition as per IEC61439.Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
each section.(as per drawing- enclosed)) -LIFT
PANEL., (as per drawing enclosed))

INCOMER:-
1 No 63Amps FP ,MCCB adjustable with rotary
handle
1 set Phase Indicating LED
1 No. Digital Ammeter with Suitable CT's
1 No.Digital Voltmeter
3 Nos. Control MCB

BUSBAR :-
100 Amps 4 pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING
3 No 32Amps FP ,MCCB adjustable with rotary
handle for Lift-1, Lift-2 & Spare
3Nos 32 AMP TPN 10 ka MCB
2 nos 4 pole 300 ma RCBO each 2 177600 355200

Sign and Stamp of EPIL 118 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supply, Erection, Testing and commissioning of
Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.06 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted,compartments in tier formation,
extensible on both sides.The panel to be provided
with PVC Sleeved 4 pole Electrolytic Al .Maximum
Current density for the bus bars shall be meet temp
rise condition as per IEC61439. Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
each section.(as per drawing- enclosed)) -UPS
INCOMER:-
2 Nos. 400Amps FP ,MCCB adjustable with rotary
handle from Essential Panel
2 sets of phase indication light with MCB
Note : Both shall be interlocked with each other
BUSBAR : 500A FP Aluminium Busbar
3 Nos. 250Amps FP ,MCCB adjustable with rotary
handle before By Pass Switch
3 Nos. 250A By Pass Switch
3 Nos. 250Amps FP ,MCCB adjustable with rotary
handle after By Pass Switch
3 Nos Multifinction Meter With RS-485 port
3 sets ON/OFF indication light with MCB
9 Nos. CT- 250/5A,
10 Nos. Control MCB

BUSBAR :-
400 Amps 3pole & 600 Amps Neutral aluminum
conductor ( CD 0.8A /sq.mm. ) bus bar (PVC
sleeve Heat-shrinkable busbar insulation)
supported by DMC / FRP insulato₹(MAIN
BUSBAR)

OUTGOING
5 Nos. 100 Amps FP ,MCCB adjustable with rotary
handle for II-Fl UPS DB, III-Fl UPS DB, Cath LAB
DB, Dialysis DB, Spare
8 Nos 63 Amps FP ,MCCB adjustable with rotary
handle for IV-Fl UPS DB, OT-1 DB, OT-2 DB, OT-
3 DB, OT-4 DB, ICU UPS DB, NICU UPS DB,
Spare
3 Nos 40 Amps FP ,MCCB adjustable with rotary
each 1 1129772 1129772
handle for GF, 1F & spare

Supply, Erection, Testing and commissioning of


16.07 N.S.R.
Indoor type ( IP 54 Protection ) cubicle pattern

Sign and Stamp of EPIL 119 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
INCOMER:-
1 No. 100Amps FP ,MCCB adjustable with rotary
handle from Essential Panel
1 set Phase Indicating LED
1 Nos Multifinction Meter With RS-485 port
3 Nos. CT- 100/5A,
3 Nos. Control MCB

BUSBAR :-
200 Amps 4pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING
2 Nos. 18KW S/D Starter with 63A TPN MCCB,
ON/OFF/TRIP Indication with ON/OFF Push button
and Ammeter
2 Nos. 7.5KW S/D Starter with 25A TPN MCCB,
ON/OFF/TRIP Indication with ON/OFF Push button
and Ammeter
6 Nos. 63A TP Contactor with (18A-24A) thermal
overload relay
6 Nos. 25A TP Contactor with (8A-12A) thermal
overload relay
2 No 63 Amps TPN ,MCCB adjustable with rotary
handle for Spare
each 1 333375 333375

Supply, Erection, Testing and commissioning of


Indoor type ( IP 54 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
16.08 N.S.R. design, modular construction with Form 4b
separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted,compartments in tier formation,
extensible on both sides.The panel to be provided
with PVC Sleeved 4 pole Electrolytic Al .Maximum
Current density for the bus bars shall be meet temp
rise condition as per IEC61439. Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
each section.(as per drawing- enclosed)) -
INCOMER:-
1 No. 250Amps FP ,MCCB adjustable with rotary
handle from Essential Panel
1 set Phase Indicating LED
1 Nos Multifinction Meter With RS-485 port
3 Nos. CT- 250/5A,
3 Nos. Control MCB

Sign and Stamp of EPIL 120 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
BUSBAR :-
400 Amps 4pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING
2 Nos. 100 Amps FP ,MCCB adjustable with rotary
handle for STEAM STERILIZER, SPARE
1 Nos 160 Amps FP ,MCCB adjustable with rotary
handle for AUTOCLAVE, SPARE
3 Nos. 32Amps FP ,MCCB adjustable with rotary
handle for 2 NO AUTOCLAVE, SPARE
1 No. 63Amps FP ,MCB adjustable with rotary
handle for SPARE
1 No. 32Amps FP ,MCB adjustable with rotary
handle for SPARE
2 Nos. 16 Amps FP ,MCB adjustable with rotary
handle for SPARE
2 Nos. 6 Amps FP ,MCB adjustable with rotary
each 1 300795 300795
handle for E.T.O. M/C-1 & 2

Supply, Erection, Testing and commissioning of


Indoor type ( IP 55 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP 55
with double door & canopy as per IEC 61439,
fabricated out of (load bearing member of 2mm and
non load bearing member 1.6 mm thick) CRCA
16.09 N.S.R. sheet steel in Compartmentised design, modular
construction with Form 4b separation for Main
Panels & 3b for remaining, Mounting Plates and all
Internal Partition shall be made of 1.6/2.0mm
Aluzinc sheet for better heat dessipation. The
cubicle should be front operated, floor
mounted,compartments in tier formation, extensible
on both sides.The panel to be provided with PVC
Sleeved 4 pole Electrolytic Al .Maximum Current
density for the bus bars shall be meet temp rise
condition as per IEC61439. Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
INCOMER:-
1 No. 250Amps FP ,MCCB adjustable with rotary
handle from ESSENTIAL Panel
1 set Phase Indicating LED
1 Nos Multifinction Meter With RS-485 port
3 Nos. CT-250/5A,
3 Nos. Control MCB

BUSBAR :-
300 Amps 4pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING

Sign and Stamp of EPIL 121 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
3 Nos.100 Amps FP ,MCCB adjustable with rotary
handle for X-RAY-1+2 & SPARE
2 No. 32 Amps FP ,MCB 10kA for Physiotheraty
2 No. 10 Amps FP ,MCB 10kA for MINOR OT
3 No. 06 Amps FP ,MCB 10kA for ECG &SPARE
each 1 233341 233341

Supply, Erection, Testing and commissioning of


Indoor type ( IP 55 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP 55
with double door & canopy as per IEC 61439,
fabricated out of (load bearing member of 2mm and
non load bearing member 1.6 mm thick) CRCA
16.10 N.S.R. sheet steel in Compartmentised design, modular
construction with Form 4b separation for Main
Panels & 3b for remaining, Mounting Plates and all
Internal Partition shall be made of 1.6/2.0mm
Aluzinc sheet for better heat dessipation. The
cubicle should be front operated, floor
mounted,compartments in tier formation, extensible
on both sides.The panel to be provided with PVC
Sleeved 4 pole Electrolytic Al .Maximum Current
density for the bus bars shall be meet temp rise
condition as per IEC61439. Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
INCOMER:-
1 No. 160Amps FP ,MCCB adjustable with rotary
handle from ESSENTIAL Panel
1 set Phase Indicating LED
1 Nos Multifinction Meter With RS-485 port
3 Nos. CT- 160/5A,
3 Nos. Control MCB

BUSBAR :-
300 Amps 4pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING
3 No. 63 Amps FP ,MCB 10kA for Histopathology
bio-chemistry + spare
2 No.32 Amps FP ,MCB 10kA for blood bank
4 No. 16 Amps FP ,MCB 10kA f
8 No. 10 Amps FP ,MCB 10kA for Physiotheraty each 1 190993 190993

Sign and Stamp of EPIL 122 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supply, Erection, Testing and commissioning of
Outdoor type ( IP 55 Protection ) cubicle pattern
LT Switch-Board with a rupturing capacity of 50
KA at 415 V for 1 sec or as called for in individual
items, openable in front and back suitable for 3
phase, 4 wire, 50Hz AC supply at an ambient
temperature of 45 C. The cubicle should be
weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP 55
with double door & canopy as per IEC 61439,
fabricated out of (load bearing member of 2mm and
non load bearing member 1.6 mm thick) CRCA
16.11 N.S.R. sheet steel in Compartmentised design, modular
construction with Form 4b separation for Main
Panels & 3b for remaining, Mounting Plates and all
Internal Partition shall be made of 1.6/2.0mm
Aluzinc sheet for better heat dessipation. The
cubicle should be front operated, floor
mounted,compartments in tier formation, extensible
on both sides.The panel to be provided with PVC
Sleeved 4 pole Electrolytic Al .Maximum Current
density for the bus bars shall be meet temp rise
condition as per IEC61439.Bus Bar and PVC
insulated solid interconnections and also provided
with 50x6mm. horizontal AL Earth Bus Bars in
INCOMER:-
1 No. 500Amps FP ,MCCB adjustable with rotary
handle from Housing Transformer
1 set Phase Indicating LED
1 Nos Multifinction Meter With RS-485 port
3 Nos. CT- 500/5A,
3 Nos. Control MCB

BUSBAR :-
600 Amps 4pole aluminum conductor ( CD 0.8A
/sq.mm. ) bus bar (PVC sleeve Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulato₹(MAIN BUSBAR)

OUTGOING
2 Nos.200 Amps FP ,MCCB adjustable with rotary
handle for 4 BHK, SPARE
4 Nos. 100 Amps FP ,MCCB adjustable with rotary
handle for 2 BHK-1, 2 BHK-2, 3 BHK & SPARE

1 No. 63 Amps FP ,MCCB adjustable with rotary


each 1 362501 362501
handle for COMMON

Fabrication, supply, installation, testing and


commissionings of cubicle type out door type ,
floor mounted L.T. panel made out of 16mm thick
CRCA sheet including connection, inter-connection
alongwith 4 stsrip aluminium bus bar as per CP WD
specifications, ( Part IV - Sub-station) and IS: 8623
comprising of followings panel mounting
switchgears etc. as required., EXTERNAL
LIGHTING PANEL for Hospital

Sign and Stamp of EPIL 123 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Fabrication, supply, installation, testing and
commissionings of cubicle type out door type ,
floor mounted L.T. panel made out of 16mm thick
CRCA sheet including connection, inter-connection
16.12 N.S.R. alongwith 4 stsrip aluminium bus bar as per CP WD
specifications, ( Part IV - Sub-station) and IS: 8623
comprising of followings panel mounting
switchgears etc. as required., EXTERNAL
LIGHTING PANEL for Hospital

(all MCCB are min. 25 KA fault rating )


A) Incoming
i) 1 Nos.40 Amps TPN MCCB adjustable Thermal
magnetic release with with rotary handle
ii) 100 amp 4 pole AL Busbar of 100 Amp
iii) 1 set of phase indication lights.
iv) 1 set of 3 phase contactor
iii) 1 set of Photo electric switch
iv) 3 nos of timer switch & contactor
v) 10 nos 32 amp DP MCB 10 kA
vi) 2 nos industrial plug & socket with 15 amp SP
MCB
vii) 1no 10 watt LED Lamp with holder & switch
set 1 130183 130183
,socket

Supply, Erection, Testing and commissioning of


indoor type cubicle pattern L T Switch-Board with a
rupturing capacity of 50 KA at 415 V or as called
for in individual items, openable in front and back
suitable for 3 phase, 4 wire, 50Hz AC supply at an
ambient temperature of 45 C. The cubicle should
be weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
design, modular construction with Form 4b
16.13 N.S.R. separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation The cubicle should be front operated,
floor mounted, free standing with compartments in
tier formation, extensible on both sides. The panel
to be provided with PVC Sleeved TPN Electrolytic
Al. Bus Bar and PVC insulated solid
interconnections and also provided with 50x6mm.
horizontal tinned copper Earth Bus Bars in each
section.(as per drawing no- EL-01- enclosed)) -
METER BOARD for TYPE-III

i) 1 Nos. 100 Amps TPN MCCB adjustable Thermal


magnetic release with with rotary handle

ii) 1 set of phase indication lights.

iii) Bus bar :- 150 Amps TP&N 50 kA aluminum


conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulators.

OUTGOING
i) 8 Nos. 32 Amps , 10 ka,D Corve, DP MCB

Sign and Stamp of EPIL 124 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
ii) 8 Nos. space for Kwh meter along with locking
set 1 104696.92 104696.92
arrangements

Supply, Erection, Testing and commissioning of


indoor type cubicle pattern L T Switch-Board with a
rupturing capacity of 50 KA at 415 V or as called
for in individual items, openable in front and back
suitable for 3 phase, 4 wire, 50Hz AC supply at an
ambient temperature of 45 C. The cubicle should
be weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
design, modular construction with Form 4b
16.14 N.S.R. separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted, free standing with compartments in
tier formation, extensible on both sides. The panel
to be provided with PVC Sleeved TPN Electrolytic
Al. Bus Bar and PVC insulated solid
interconnections and also provided with 50x6mm.
horizontal tinned copper Earth Bus Bars in each
section.(as per drawing no- EL-01- enclosed)) -
METER BOARD for TYPE -II

i) 1 Nos. 100 Amps TPN MCCB adjustable Thermal


magnetic release with with rotary handle

ii) 1 set of phase indication lights.

iii) Bus bar :- 150 Amps TP&N 50 kA aluminum


conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulators.

OUTGOING
i) 8 Nos.32 Amps , 10 ka,D Corve, DP MCB
ii) 8 Nos. space for Kwh meter along with locking
set 1 104696.92 104696.92
arrangements

Sign and Stamp of EPIL 125 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Supply, Erection, Testing and commissioning of
indoor type cubicle pattern L T Switch-Board with a
rupturing capacity of 50 KA at 415 V or as called
for in individual items, openable in front and back
suitable for 3 phase, 4 wire, 50Hz AC supply at an
ambient temperature of 45 C. The cubicle should
be weather proof, dust proof vermin proof, well
ventilated and enclosure protection shall be IP-54
as per IEC 61439, fabricated out of (load bearing
member of 2mm and non load bearing member 1.6
mm thick) CRCA sheet steel in Compartmentised
design, modular construction with Form 4b
16.15 N.S.R. separation for Main Panels & 3b for remaining,
Mounting Plates and all Internal Partition shall be
made of 1.6/2.0mm Aluzinc sheet for better heat
dessipation. The cubicle should be front operated,
floor mounted, free standing with compartments in
tier formation, extensible on both sides. The panel
to be provided with PVC Sleeved TPN Electrolytic
Al. Bus Bar and PVC insulated solid
interconnections and also provided with 50x6mm.
horizontal tinned copper Earth Bus Bars in each
section.(as per drawing no- EL-01- enclosed)) -
METER BOARDfor TYPE -IV

i) 1 Nos. 200 Amps TPN MCCB adjustable Thermal


magnetic release with with rotary handle

ii) 1 set of phase indication lights.

iii) Bus bar :- 300 Amps TP&N 50 kA aluminum


conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulators.

OUTGOING
i) 8 Nos. 63 Amps , 10 ka,D Corve, TPN MCB
ii) 8 Nos. space for Kwh meter along with locking
set 2 145331.02 290662.04
arrangements

Fabrication, supply, installation, testing and


commissionings of cubicle type out door floor
mounted L.T. panel made out of 16mm thick
CRCA sheet including connection, inter-connection
alongwith 4 stsrip aluminium bus bar as per IEC
61439, fabricated out of (load bearing member of
2mm and non load bearing member 1.6 mm thick)
16.16 N.S.R. CRCA sheet steel in Compartmentised design,
modular construction with Form 4b separation for
Main Panels & 3b for remaining, Mounting Plates
and all Internal Partition shall be made of
1.6/2.0mm Aluzinc sheet for better heat
dessipation. comprising of followings panel
mounting switchgears etc. as required., Utility
Panel-common area
from main ESSENTIAL PANEL
(all MCCB are min. 25 KA fault rating )
A) Incoming
i) 1 Nos.63 Amps FP ONLOAD CHANGEOVER
ii) 1 Nos.63 Amps TPN MCCB adjustable Thermal
magnetic release with with rotary handle

Sign and Stamp of EPIL 126 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

PROTECTION INSTRUMENT
i) 1 set of phase indication lights.
ii) 1 sets of indication lights, phase, breaker ON-
OFF, , etc.
iii) 1 no 3 phase combined voltmeter, ammeter &
frequency meter , approved make with following
feature with suitable CT's
a) Latest Micro controller based technology,three
indipendent windows to view V,A & Hz per
phasesimultanously
b) Ultra bright LED Display for clear front & long
distance viewing
c)CT's ratio programable through front key ped
d) Four digit frequency meter with 0.01Hz
resolution

iv) Bus bar :- 100 Amps TP&N 50 kA aluminum


conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP
insulators.

1 no space for Dual source ( normal & DG supply )


3 phase Kwh meter board and space for its CT's
along with double locking arrangements
OUTGOING
i) 2 Nos. 63 Amps, 10 ka, TPN MCB
ii) 2 Nos. 32 Amps, 10 ka, TPN MCB
iii) 3 Nos. 16 Amps, 10 ka, SPN MCB
iv) 7 Nos. 6 Amps, 10 ka, SPN MCB
v)2 no 10 watt LED Lamp with holder & switch 342879.4
set 1 342879.4
,socket

Total carried over to summary ₹ 12846087.28

SUBHEAD -XVII . CABLES AND TERMINATION


a) hospital
Supply,Receiving of 1100V grade XLPE AA Cable
17.01
as per follows;
a) 4x6 sqmm mtr 200 125.75 25150
b) 4x10 sqmm mtr 200 158.59 31718
c) 3.5*35 sqmm mtr 100 273.16 27316
d) 3.5*50 sqmm mtr 400 352.11 140844
e) 3.5*70 sqmm mtr 750 477.86 358395
h) 3.5*95 sqmm mtr 200 594.53 118906
g) 3.5*120 sqmm mtr 350 741.94 259679
h) 3.5*150 sqmm mtr 1300 880.27 1144351
i) 3.5*185 sqmm mtr 650 1095.44 712036
j) 3.5*240 sqmm mtr 1250 1380.48 1725600
k 3.5*400 sqmm mtr 1150 2152.46 2475329

Laying and fixing of one number PVC insulated and


PVC sheathed / XLPE power cable of 1.1 KV grade
17.02
of following size on wall surface as required.

Upto 35 sq. mm (clamped with 1mm thick saddle)


a) 7.7.1 mtr 100 25 2500
Above 35 sq. mm and upto 95 sq. mm (clamped
b) 7.7.2 mtr 500 72 36000
with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped
c) 7.7.3 mtr 450 84 37800
with 25/ 40x3mm MS flat clamp)

Sign and Stamp of EPIL 127 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Above 185 sq. mm and upto 400 sq. mm
d) 7.7.4 mtr 450 120 54000
(clamped with 40x3mm MS flat clamp)

Laying of one number PVC insulated and PVC


sheathed / XLPE power cable of 1.1 KV grade of
17.03
following size in the existing masonry open duct as
required.
a) 7.6.1 Upto 35 sq. mm mtr 50 14 700
b) 7.6.2 Above 35 sq. mm and upto 95 sq. mm mtr 200 22 4400
c) 7.6.3 Above 95 sq. mm and upto 185 sq. mm mtr 600 31 18600
d) 7.6.4 Above 185 sq. mm and upto 400 sq. mm mtr 500 56 28000

Laying of one number PVC insulated and PVC


sheathed / XLPE power cable of 1.1 kV grade of
17.04 following size direct in ground including excavation,
sand cushioning, protective covering and refilling
the trench etc. as required.
a) 7.1.1 Upto 35 sq. mm mtr 100 206 20600
b) 7.1.2 Above 35 sq. mm and upto 95 sq. mm mtr 100 214 21400
c) 7.1.3 Above 95 sq. mm and upto 185 sq. mm mtr 300 223 66900
d) 7.1.4 Above 185 sq. mm and upto 400 sq. mm mtr 7 248 1736

Laying of one number additional PVC insulated


and PVC sheathed / XLPE power cable of 1.1 kV
grade of following size direct in ground in the same
17.05
trench in one tier horizontal formation including
excavation, sand cushioning, protective covering
and refilling the trench etc. as required.
a) 7.2.1 Upto 35 sq. mm mtr 100 141 14100
b) 7.2.2 Above 35 sq. mm and upto 95 sq. mm mtr 50 149 7450
c) 7.2.3 Above 95 sq. mm and upto 185 sq. mm mtr 300 158 47400
d) 7.2.4 Above 185 sq. mm and upto 400 sq. mm mtr 750 183 137250

CABLE ENDS
Supplying and making end termination with double
brass compression gland and aluminium lugs for
17.06 following size of PVC insulated and PVC sheathed /
XLPE aluminium conductor cable of 1.1 KV grade
as required.
a) 9.1.32 4x6 sqmm set 10 203 2030
b) 9.1.32 4x10 sqmm set 12 203 2436
c) 9.1.21 3.5*35 sqmm set 2 282 564
d) 9.1.22 3.5*50 sqmm set 10 354 3540
e) 9.1.23 3.5*70 sqmm set 10 394 3940
h) 9.1.24 3.5*95 sqmm set 8 482 3856
g) 9.1.25 3.5*120 sqmm set 4 500 2000
h) 9.1.26 3.5*150 sqmm set 22 592 13024
i) 9.1.27 3.5*185 sqmm set 6 804 4824
j) 9.1.29 3.5*240 sqmm set 14 989 13846
k) 9.1.31 3.5*400 sqmm set 48 1389 66672

b) housing
Supply,Receiving of 1100V grade XLPE AA Cable
17.07
as per follows;
a) 4x6 sqmm mtr 600 125.75 75450
b) 4x10 sqmm mtr 100 158.59 15859
c) 3.5x50 sqmm mtr 275 352.107 96829.425
d) 3.5x70 sqmm mtr 60 477.86 28671.6
e) 3.5x95 sqmm mtr 175 594.53 104042.75

Sign and Stamp of EPIL 128 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Laying and fixing of one number PVC insulated and
PVC sheathed / XLPE power cable of 1.1 KV grade
17.08
of following size on wall surface as required.

Upto 35 sq. mm (clamped with 1mm thick saddle)


a) 7.7.1 mtr 10 25 250
Above 35 sq. mm and upto 95 sq. mm (clamped
b) 7.7.2 mtr 10 72 720
with 25x3mm MS flat clamp)

Laying of one number PVC insulated and PVC


sheathed / XLPE power cable of 1.1 kV grade of
17.09 following size direct in ground including excavation,
sand cushioning, protective covering and refilling
the trench etc. as required.
a) 7.1.1 Upto 35 sq. mm mtr 570 206 117420
b) 7.1.2 Above 35 sq. mm and upto 95 sq. mm mtr 400 214 85600

Laying of one number additional PVC insulated


and PVC sheathed / XLPE power cable of 1.1 kV
grade of following size direct in ground in the same
17.10 trench in one tier horizontal formation including
excavation, sand cushioning, protective covering
and refilling the trench etc. as required.

a) 7.2.1 Upto 35 sq. mm mtr 20 141 2820


b) 7.2.2 Above 35 sq. mm and upto 95 sq. mm mtr 110 149 16390

CABLE ENDS
Supplying and making end termination with double
brass compression gland and aluminium lugs for
17.11 following size of PVC insulated and PVC sheathed /
XLPE aluminium conductor cable of 1.1 KV grade
as required.
a) 9.1.32 4x6 sqmm set 30 203 6090
b) 9.1.32 4x10 sqmm set 4 203 812
c) 9.1.11 3.5*50 sqmm set 8 286 2288
d) 9.1.12 3.5*70 sqmm set 2 361 722
e) 9.1.13 3.5*95 sqmm set 8 431 3448

Total carried over to summary ₹

Total carried over to summary ₹ 8192304.775

SUBHEAD -XVIII . EXTERNAL LIGHTING


Hospital
Supplying of 6 mtr High 3 mm thich Octagonal GI
Pole along with base plate 200x200x12 mm
thick,foundation bolt size 4 nos 20 mm dia ,600 mm
long ,200 mm pitch circle dia (PCD) and 100 mm
18.01 N.S.R. Each 23 27002 621046
projected bolt length suitable for 600 mm long for
pole having top70 mm dia and bottam 130 mm dia
A/F single bracket ,suitable for 60 watt LED
luminairs

Supplying of 3 mtr High 3 mm thich Octagonal GI


Pole along with base plate 200x200x12 mm
thick,foundation bolt size 4nos 16 mm dia ,450 mm
long ,200 mm pitch circle dia (PCD) and 80 mm
18.02 N.S.R. Each 15 20516 307740
projected bolt length suitable for 450 mm long for
pole having top70 mm dia and bottam 130 mm dia
A/F single bracket ,suitable for 40 watt LED lamp
luminairs

Sign and Stamp of EPIL 129 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

Supplying & assambling single arm bracket 1.0 mtr


18.03 N.S.R. long for pole having top 70 mm A/F t ,suitable for each 23 2461 56603
60 watt LED

Erection of metallic pole of following length in


cement concrete 1:3:6 (1 cement : 3 coarse sand :
18.04 11.3.1 6 graded stone aggregate 40 mm nominal size) each 57 2760 157320
foundation including excavation and refilling etc. as
required.
upto 6.5 meter

Providing, laying and fixing following dia G.I. pipe


(medium class) in ground complete with G.I. fittings
18.05
including trenching (75 cm deep) and re-filling etc.
as required
i) 14.13.3 100 mm dia for Gate crossing Mtr 20 828 16560
ii) 14.13.4 150 mm dia for bridge crossing Mtr 20 1265 25300

Supplying and laying of following size DWC HDPE


pipe ISI marked along with all accessories like
socket, bend, couplers etc. conforming to IS 14930,
18.06
Part II complete with fitting and cutting, jointing etc.
in the existing trench, complete as required.

63 mm dia (OD-63 mm & ID-51 mm nominal) for


14.15.1 Mtr 43 79 3397
pole

street light
SITC of street LED light- Decorative Energy
Saving LED Street light with PDC Aluminium Body
and Clear Polycarbonate cover. Wide beam
18.07 each 23 9784 225032
distribution. CCT 5700K. IP 66.similar to polycab
cat no PUB0504006 PCGLS TO 70 70 W 5700 K 1

SITC of Post Top LED light-Powder coated PDC


Aluminium body with opal diffuser. Suitable for
18.08 each 15 12218 183270
landscape lighting.Available CCT 3000K. IP 54.

SITC of LED Flood Light- Energy Saving LED


Flood light, powder coated PDC Aluminium body
with toughened glass visor fitted in frame. Efficacy
18.09 each 6 11535 69210
> 90 Lm/W.Available CCT 6000K. IP 65.similar to
polycab cat no-PAR0201005 PCGLF 02 80 80 W
6000 K
solar street light

SITC of solar stand alon street light system


18.10 includes 20 watts LED street Light DC Luminaire , each 19 36627.5 695922.5
100 Wp SPV Panel module capacity , 12V / 75 Ah
Lead Acid Battery, 5 mtr Powder Coated MS pole

Providing, laying and fixing following dia RCC pipe


NP2 class (light duty) in ground complete with RCC
18.11 collars, jointing with cement mortar 1:2 (1 cement :
2 fine sand) including trenching (75 cm deep) and
refilling etc as required.
i) 14.14.1 100 mm dia mtr 50 355 17750
ii) 14.14.2 150 mm dia mtr 100 405 40500
iii) 14.14.3 250 mm dia mtr 100 478 47800

Sign and Stamp of EPIL 130 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
b HOUSING

N.S.R. Supplying of 6 mtr High 3 mm thich Octagonal GI


Pole along with base plate 200x200x12 mm
thick,foundation bolt size 4 nos 20 mm dia ,600 mm
long ,200 mm pitch circle dia (PCD) and 100 mm
18.12 Each 16 27002 432032
projected bolt length suitable for 600 mm long for
pole having top70 mm dia and bottam 130 mm dia
A/F single bracket ,suitable for 60 watt LED
luminairs

N.S.R. Supplying of 3 mtr High 3 mm thich Octagonal GI


Pole along with base plate 200x200x12 mm
thick,foundation bolt size 4nos 16 mm dia ,450 mm
long ,200 mm pitch circle dia (PCD) and 80 mm
18.13 Each 7 20516 143612
projected bolt length suitable for 450 mm long for
pole having top70 mm dia and bottam 130 mm dia
A/F single bracket ,suitable for 40 watt LED lamp
luminairs

N.S.R. Supplying & assambling single arm bracket 1.0 mtr


18.14 long for pole having top 70 mm A/F t ,suitable for each 16 2208 35328
60 watt LED

11.3.1 Erection of metallic pole of following length in


cement concrete 1:3:6 (1 cement : 3 coarse sand :
6 graded stone aggregate 40 mm nominal size) each 35 2760 96600
foundation including excavation and refilling etc. as
required. upto 6.5 meter

Providing, laying and fixing following dia G.I. pipe


(medium class) in ground complete with G.I. fittings
including trenching (75 cm deep) and re-filling etc.
as required
14.13.3 100 mm dia for Gate crossing Mtr 10 828 8280
14.13.4 150 mm dia for bridge crossing Mtr 20 1265 25300
Supplying and laying of following size DWC HDPE
pipe ISI marked along with all accessories like
socket, bend, couplers etc. conforming to IS 14930,
Part II complete with fitting and cutting, jointing etc.
in the existing trench, complete as required.

14.15.1 63 mm dia (OD-63 mm & ID-51 mm nominal) for 79


Mtr 30 2370
pole

street light
SITC of street LED light- Decorative Energy
Saving LED Street light with PDC Aluminium Body
and Clear Polycarbonate cover. Wide beam
18.15 each 16 9784 156544
distribution. CCT 5700K. IP 66.similar to polycab
cat no PUB0504006 PCGLS TO 70 70 W 5700 K 1

SITC of Post Top LED light-Powder coated PDC


Aluminium body with opal diffuser. Suitable for
18.16 each 7 12218 85526
landscape lighting.Available CCT 3000K. IP 54.

Solar street light

Sign and Stamp of EPIL 131 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

SITC of solar stand alon street light system


18.17 includes 20 watts LED street Light DC Luminaire , each 12 36627 439524
100 Wp SPV Panel module capacity , 12V / 75 Ah
Lead Acid Battery, 5 mtr Powder Coated MS pole

Providing, laying and fixing following dia RCC pipe


NP2 class (light duty) in ground complete with RCC
18.18 collars, jointing with cement mortar 1:2 (1 cement :
2 fine sand) including trenching (75 cm deep) and
refilling etc as required.
a) 14.14.1 100 mm dia mtr 20 355 7100
b) 14.14.2 150 mm dia mtr 50 405 20250
c) 14.14.3 250 mm dia mtr 30 478 14340

Total carried over to summary ₹ 3934256.5

SUBHEAD - XIX . DIESEL GENERATOR

19.01 Sub-head 'A' (Equipments)

SITC of “Silent Type” following KVA Sound


Attenuated DG Set comprising of engine coupled to
415V, following KVA alternator mounted on a
common Base Frame along with other accessories
i.e. Engine Control Panel Auto/Manual (Mounted on
Engine), Fuel tank, Batteries with leads i/c AMF
Panel etc. as reqd. complete. The DG Set should
19.01
be supplied with cable end box to accommodate
suitable size and no. of cable on alternator
complete as reqd. The canopy should be designed
in such a way so that the Noise level can be
restricted to 75 db level at a distance of 1 meter
away from the DG Set.

a)Diesel Engine:
Diesel engine 4 stroke, water cooled, electric start,
of suitable BHP at 1500 RPM suitable for following
KVA output of alternator at 40 Degree C, 50%RH &
at 1000 Meter MSL and conforming to BS 5514, BS
649, IS 10000, capable of taking 10% over loading
for one hour after 12 hours of continuous operation.
The engine will be fitted complete with all the
required accessories.

b) Engine mounted Instrument Panel


(Auto/Manual) fitted with and having digital
display for following:
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lub. Oil trip pressure indication
(ix) Engine Hours indication
c) Alternator :

Sign and Stamp of EPIL 132 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
Synchronous alternator rated at following KVA, 415
volts at 1500 RPM, 3 phase 50 Hz, AC supply with
0.8 lagging power factor at 40 Degree C, 50% RH &
at 1000 Meter MSL. The alternator shall be having
SPDP enclosure, brushless, continuous duty, self-
excited and self-regulated through AVR conforming
to IS: 4722/BS 2613 suitable for tropical conditions
and with class-F/H insulation.

d)Base Frame & Foundation FOR Engine and


Alternator:
Both the engine and alternator shall be mounted on
suitable base frame made of MS channel with
necessary reinforcement which shall be installed on
suitable cement concrete foundation and vibration
isolation arrangement as per recommendations of
manufacturer.
e)Base Frame & Foundation For Daily Service
Fuel Tank:
Daily service fuel tank of 990 liters capacity
fabricated out of 3mm thick M.S. sheet complete
with all standard accessories and fuel piping
between fuel tank and diesel engine with MS class
'C' pipes of suitable dia. Complete with valves, level
indications & accessories as required as per
specifications.
f) Exhaust System:
Dry exhaust manifold with hospital exhaust silencer
and catalytic convertor.
g) Starting System:
24v DC starting system comprising of starter
motors: voltage regulator and arrangement for
initial excitation complete with suitable nos. of
batteries (25 plates, 180 Amp / as per OEM.-Hour
capacity lead acid type) as required as per
specifications.
h) Acoustic and weather proof enclosure
Acoustic and weather proof enclosure with
arrangement for fresh air intake for cooling of the
engine & alternator, extraction, discharging hot air
into the atmosphere as per specifications.

19.01-A a ) 500 KVADG Set Set 1 3625351 3625351

19.01-B b ) 250 KVADG Set Set 1 2154795 2154795

Supplying, Installing, Testing and Commissioning at


site of automatic mains failure control including
auto by-pass panel, suitable for 500 KVA silent
type Dg set complete with relays, timers, set of CTs
for metering & protection and energy analyser to
indicate currents, phase and line voltages,
19.01.2 frequency, power factor, KWH, KVARH & provision
for overload, short circuit, restricted earth fault,
under frequency, control cabling from AMF panel to
diesel engine and elsewhere if required, all
complete and inter locking including the folloewing
and as per specification.:

Sign and Stamp of EPIL 133 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
1 No. 800 amps 4 pole electrically operated
electrically draw out type air circuit breaker with
microprocessor release unit for short circuit, over
(a) current ,shunt trip. and earth fault protection with
adjustable setting including suitable rating of CT's
as required and as per specification .

(b) Auto/Manual/Test/Off selector switch


(c) 1 Nos. reverse power relay .
3 Sets of current transformers 15 p 10 accuracy for
(d)
protection and 15 VA class-1 for metering
Energy analyser unit to indicate current voltage
(e)
frequency power factor and KWH
(f) Indicating lamps for load on mains and load on set
(g) MCB for instruments
Battery charger, complete with transformer/rectifier,
(h) D.C. voltmeter and ammeter, selector switch for
trickle, off and boost and current adjustment.
(i) Main supply failure monitor
(j) Supply failure timer
(k) Restoration timer
Control unit with three impulse automatic engine
(l)
start/stop and failure to start lockout.
(m) Impulse counter with locking and reset facility.
(n) ON/OFF/Control circuit switch with indicator
(o) Audio/Video annunication for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning set 1 535156 535156

Supplying, Installing, Testing and Commissioning at


site of automatic mains failure control including
auto by-pass panel, suitable for 250 KVA silent
type Dg set complete with relays, timers, set of CTs
for metering & protection and energy analyser to
indicate currents, phase and line voltages,
19.01.3
frequency, power factor, KWH, KVARH & provision
for overload, short circuit, restricted earth fault,
under frequency, control cabling from AMF panel to
diesel engine and elsewhere if required, all
complete and inter locking including the folloewing
and as per specification.:

1 No. 630 amps 4 pole electrically operated


electrically draw out type air circuit breaker with
microprocessor release unit for short circuit, over
(a)
current ,shunt trip. and earth fault protection with
adjustable setting including suitable rating of CT's
as required and as per specification .

(b) Auto/Manual/Test/Off selector switch


(c) 1 Nos. reverse power relay .

Sign and Stamp of EPIL 134 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount

3 Sets of current transformers 15 p 10 accuracy for


(d)
protection and 15 VA class-1 for metering
Energy analyser unit to indicate current voltage
(e)
frequency power factor and KWH
(f) Indicating lamps for load on mains and load on set
(g) MCB for instruments
Battery charger, complete with transformer/rectifier,
(h) D.C. voltmeter and ammeter, selector switch for
trickle, off and boost and current adjustment.
(i) Main supply failure monitor
(j) Supply failure timer
(k) Restoration timer
Control unit with three impulse automatic engine
(l)
start/stop and failure to start lockout.
(m) Impulse counter with locking and reset facility.
(n) ON/OFF/Control circuit switch with indicator
(o) Audio/Video annunication for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning set 1 535156 535156

FOUNDATION
14.1 Providing and laying in position reinforced cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) in
19.02 CUM 15.144 5487 83095
foundation of pump, DG set etc. including form
work etc. as required (excluding reinforcement).
cum 5487

For “Operation and Comprehensive


19.03 maintenance of 500 KVA & 250 KVA DG Sets”
after DLP
Description of Work
Operation Charges for 500 & 250 KVA DG Sets Per
1 during DLP including all taxes annum
per set
Operation and comprehensive annual Per
2 maintenance charges for 500 & 250 KVA DG annum
Sets for 1st year after DLP per set

Operation and comprehensive annual Per


3 maintenance charges for 500 & 250 KVA DG annum
Sets for 2nd year after DLP per set

Operation and comprehensive annual Per


4 maintenance charges for 500 & 250 KVA DG annum
Sets for 3rd year after DLP per set

Operation and comprehensive annual Per


5 maintenance charges for 500 & 250 KVA DG Sets annum
for 4th year after DLP per set

Total carried over to summary ₹ 6933553

SUBHEAD - XX . UPS SYSTEM

Sign and Stamp of EPIL 135 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
SUPPLYING, testing & commissioning of 3 x 100
KVA True Online double conversion and fully
Microprocessor Controlled UPS system with IGBT
Rectifier and connected in “Parallel Redundant
load sharing Configuration.” including RS 485
Modbus Communication port with inbuilt galvanic
and electronic isolation at the output with
20.01
accessories and suitable Power Management
software in each UPS as per specification Suitable
for SERVER , COMPUTER , TELEPHONE
EXCHANGE ,FAX MACHINE , CCTV,PA SYSTEM,
,BMS SYSTEM , MEDICAL EQUIPMENTS & FIRE
ALARM PANEL load
Nos. 3 1617187.5 4851562.5

UPS SYSTEM ALONG WITH SMF BATTERY


BACKUP USING 12V BATTERIES OF APPROVED
MAKE EQVT MAKE, DISCONNECTOR FOR
BATTERY PROTECTION, MS RACK,
INTERLINKS AND DC CABLE UPTO 10 MTRS
FROM UPS TO BATTERIES.

12VDC /120AH X40 Nos./UPS /as per vender


calculation

Including supplying , testing & commissioning of


APPROVED MAKES 100 KVA 3PH-3PH TRUE
ONLINE UPS SYSTEM IN PARALLEL
CONFIGURATION ALONG WITH SMF BATTERY
OF 12V-120 AH-40 NOS FOR UPTO 20 MIN .
BACK-UP BATTERY AS PER APPROVED MAKE ,
UPS- APPROVED MODEL WITH MS
RACK,INTERLINKS AND DC CABLE UPTO 5
MTRS FROM UPS TO BATTERIES. (20Min.
Back-up (3UPS IN Parallel )

SPECIAL FEATURES :
IGBT BASED RECTIFIER AND INVERTER
INPUT VOLT 415V - 15% + 10%, THREE PHASE
4 WIRE
OUTPUT VOLT 415V +/- 1%, THREE PHASE 4
WIRE
OVERALL EFFICEINCY UPTO 94%
OUTPUT FREQUENCY 50 HZ +/- 0.1 HZ
INPUT POWER FACTOR >0.99, CURRENT
HARMONICS <3%
OUTPUT POWER FACTOR 0.9 LAGGING
INBUILT ISOLATION TRANSFORMER
Inclusive SUPPLYING OF BATTERY
ACCESSORIES
a) Battery Rack for 100 KVA UPS
b)Battery Interconnecting Links for 100 KVA UPS

c) Battery to UPS Cable (Maximum 10 meters) for


100 KVA UPS
d) Battery Fuse Box for 100 KVA UPS.

INSTALLATION AND COMMISSIONING OF 100


20.02 KVA UPS WITH BATTERY AND ACCESSORIES
set 3 23000 69000

Sign and Stamp of EPIL 136 Sign and Stamp of Bidder


Sl.no. DSR-16 Description of items Unit QTY Rate Amount
SUPPLYING, testing & commissioning of 1 x 10
KVA True Online double conversion and fully
Microprocessor Controlled UPS system with IGBT
Rectifier including RS 485 Modbus
20.03 Communication port with inbuilt galvanic and
electronic isolation at the output with accessories
and suitable Power Management software in each
UPS as per specification Suitable for OT load
Nos. 3 162366 487098

UPS SYSTEM ALONG WITH SMF BATTERY


BACKUP USING 12V BATTERIES OF APPROVED
MAKE EQVT MAKE, DISCONNECTOR FOR
BATTERY PROTECTION, MS RACK,
INTERLINKS AND DC CABLE UPTO 5 MTRS
FROM UPS TO BATTERIES.

12vdc, 26Ahx15 Nos./UPS / as pervender


calculation

including Supplying , testing & commissioning of


APPROVED MAKES 10 KVA 1PH-1PH TRUE
ONLINE UPS SYSTEM (Standalone) ALONG
WITH SMF BATTERY OF 12V-26 AH-15 NOS
FOR UPTO 20 MIN . BACK-UP BATTERY AS PER
APPROVED MAKE , UPS- APPROVED MODEL
WITH MS RACK,INTERLINKS AND DC CABLE
UPTO 10 MTRS FROM UPS TO BATTERIES.

SPECIAL FEATURES :
IGBT BASED RECTIFIER AND INVERTER
INPUT VOLT 230V - 15% + 10%, SINGLE PHASE
4 WIRE
OUTPUT VOLT 230V +/- 1%, SINGLE PHASE
&NEUTRAL
OVERALL EFFICEINCY UPTO 94%
OUTPUT FREQUENCY 50 HZ +/- 0.1 HZ
INPUT POWER FACTOR >0.99, CURRENT
HARMONICS <3%
OUTPUT POWER FACTOR 0.9 LAGGING
INBUILT ISOLATION TRANSFORMER
SUPPLYING OF BATTERY ACCESSORIES
a) Battery Rack for 10 KVA UPS
b)Battery Interconnecting Links for 20 KVA UPS
c) Battery to UPS Cable (Maximum 10 meters) for
10 KVA UPS
d) Battery Fuse Box for 10 KVA UPS.

INSTALLATION AND COMMISSIONING OF 10


20.04 KVA UPS WITH BATTERY AND ACCESSORIES
set 3 5175 15525

Total carried over to summary 5423186


GRAND TOTAL 79098581

Sign and Stamp of EPIL 137 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai

Schedule of Items - Fire fighting- BOQ


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)

SUBHEAD-I(A): FIRE PUMPS AND HYDRANT WORKS (NON SCHEDULED ITEMS)

1.1 M.R. FIRE PUMPS - ELECTRICAL


Supply, installation, testing and
commissioning of horizontal single stage
centrifugal type factory assembled fire
pumps suitable for autometic operation at
synchoronous speed of 2900 rpm, TEFC
conforming to IP-55 & flexible coupling
gaurd mounted on a common structural
base plate with 150mm dia gun metal
pressure gauges with isolation cock and
piping, suitable vibration elimination pads
of approved design for pump foundation,
motor to be suitable for 415 volts, 3 phase
50 cycles AC.

Capacity 2280 LPM at 7.0 Kg/cm2 delivery


pressure for Fire Hydrant Network.
1.1.1 Set 1 381,225.00 381,225.00
Capacity 180 LPM at 7.0 Kg/cm2 (Jockey
1.1.2 Pump). Set 1 111,435.00 111,435.00
Capacity 900 LPM at 3.5 Kg/cm2 (Roof Fire
1.3.1 Pump). Set 3 134,895.00 404,685.00
ROOF PANELS:
Supply, installation, testing and
commissioning of following integrated,
cubicle type,dead front, extensible, sheet
steel control panel. The panel shall be
suitable for 440 volts, 50 cycles, 4 wire
supply
The following components and accessories
shall be mounted with ineach control
panel.
One no 60 amps TP incoming MCCB with
the following:
0-500 volts 96 x96 square mm voltmeter
with slector switch and control fuses- 1
SET
0-100 amps 96 x96 square mm ammeter
with CT's and slector switch- 1 SET
Phase indicating lamp with toggle
switches.
Indication lamps for ON/OFF/TRIP status

Outgoing Feeders / Starters as below:


60 ATP MCCB with star / delta as starter
suitable for 15 HP motor for Downcomer
Pump - 1 Set

Sign and Stamp of EPIL 138 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Provision in control panel to connect flow
switch for autmatic operation of roof fire
pumps.

1.2 M.R. FIRE PUMPS - DIESEL


Supply, installation, testing and
commissioning of horizontal single stage
centrifugal pumping set with CI volute and
bronze impeller with mechanical seals
directly coupled to automatic Diesel
Engine complete with all accessories like
self starting by means of Battery powered
electric starter motor, Paper Filter type air
cleaner, exhaust silencer etc. complete in
all respects. The engine & the pump will
be mounted on common base plate on
anti-vibration mountings.

Capacity 2280 LPM at 7.0 Kg/cm2 delivery


pressure for Fire Hydrant & Sprinkler
Network. Set 1 639,285.00 639,285.00

Exhaust piping
Providing & fixing 150 mm diameter M.S.
Class 'C' diesel pump exhaust pipe
includings all fittings, like bends, tees etc.
clamps / structural steel supports. The
pipe shall be provided with 75mm thick
fiberglass insulation & covering the
insulation with 500 g polythene sheet
giving proper overlaps & sealing the joints
with suitable adhesive compound. The
pipe shall be provided with 24 gauge
aluminium sheet cladding
1.3 M.R. RM 20 1,712.35 34,246.91

1.5 M.R. PRESSURE SWITCH


Supplying, installing, testing and
commissioning 0 to 12 Kg/ cm2 ON/OFF
pressure switch in delivery line of pump
along with control wiring for auto starting
and auto stopping of hydrant and jockey
1.5.1 pumps. Each 6 4,855.07 29,130.42

Supply, fabrication (as per code),


installation, testing and commissioning of
Pressure vessels 450mm diameter and
1000mm high fabricated from 8-10mm
M.S. plate with accessories inside painting
with epoxy paint and outside with enamel.
1.6 M.R. Each 1 19,309.94 19,309.94

Sign and Stamp of EPIL 139 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Providing, fixing, testing & commissioning
of resilient rubber lined single arch
vibration eliminators suitable for raw
water up to 45 deg. C temperature,
working pressure 8.8 Kg/cm2 and test
pressure 14 Kg/cm2 for :-
1.7 M.R.
1.7.1 150 mm dia Each 4 5,014.58 20,058.30
100 mm dia Each 7 3,989.37 27,925.61
80 mm dia Each 1 3,287.33 3,287.33

Supply, installation, testing, trial run and


commissioning of hydrants all complete as
1.8 M.R. required and as approved
1.8.1 Fire Hose Cabinet
1.6mm thick MS door frame 900x2100
door capable of accommodating fire hose
reel, landing valve, hose pipes, fittings &
accessories. The door shall have a front
glass with lock and key arrangement &
shall be painted with post office red colour
1.8.1.1 (approval shall be taken on the basis of
submitted sample before ordering) Cost of
fire extinguishers not included in item
rate. (Liasioing with civil contractor for
making 900x600x2100 Recessed type
mansoary box (by civil contractor).
Each 28 36,949.50 1,034,586.00
TAC approved 1.6mm thick M.S. fire hose
cabinet (750x600x250mm) made out of 16
gauge M.S. sheet capable of
accommodating landing valve, hose pipes,
fittings & accessories. The box shall have a
front glass door with lock and key
arrangement & shall be painted with post
office red colour (approval shall be taken
on the basis of submitted sample before
ordering) - for external and roof hydrant.
1.8.1.2 Each 12 2,640.80 31,689.63
63mm dia single outlet GM landing valve IS
marked with suitable size bolts, nuts,
washers and gaskets. Landing valve shall
be TAC Approved Make.
1.8.2 Each 28 6,607.44 185,008.32
63mm dia twin outlet GM landing valve IS
marked with suitable size bolts, nuts,
washers and gaskets. Landing valve shall
be TAC Approved Make.
1.8.3 Each 6 13,986.47 83,918.84
First aid hose reel with 25 mm dia, 30 m
long rubber hose, ball valve, piping and
1.8.4 GM nozzle Each 28 3,966.64 111,065.85

Sign and Stamp of EPIL 140 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
63mm reinforced rubber hoses (RRL) with
male and female GM coupling, IS marked-
1.8.5 15 m long Each 68 5,520.69 375,406.92
standard short size GM branch pipe with
nozzle of 20mm nomnal bor outlet with
instaneous type 63 mm dia coupling
complete IS marked & TAC approved.
1.8.6 Each 34 2,173.50 73,899.00
1.8.7 Fire Axe Each 28 516.21 14,453.78

Supply, installation, testing and


commissioning ss orifice plates in pipelines
to reduce pressure from 8 kg. to 3.5
1.9 M.R. kg/sq.cm. Each 47 1,304.10 61,292.70

Providing, installing, testing &


commisioning of fire brigade inlet
connection (fire department connection)
consisting of 4 Nos. 63 mm dia
instantaneous inlet arranged on a 50 mm
dia header, 1 No. 150 mm diameter
Butterfly valve, 1 No. 150mm dia. Non-
return valve and wall mounted box of
M.S. construction with glass door to house
the above mentioned components.
1.10 M.R. Set 5 22,785.89 113,929.44

Providing, installing, testing &


commisioning of fire brigade draw out
connection (fire department connection)
with suction pipe MS class 'C' 100 mm dia.
& 100 mm dia. foot valve & steel chain
including wall mounted box M.S.
construction with glass door to house the
above mentioned componenets.
1.11 M.R. Set 1 12,723.07 12,723.07

TOTAL C/F TO SUMMARY 3,768,562.05

Sign and Stamp of EPIL 141 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
SUBHEAD-I (B): PIPING FOR FIRE FIGHTING SYSTEM (AS PER DSR-2016)

DSR ITEM Excavating trenches of required width for


NO 2.10 pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of
bottoms, depth upto 1.5 m including
getting out the excavated soil, and then
returning the soil as required, in layers not
exceeding 20 cm in depth including
consolidating each deposited layer by
ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a
lead of 50 m :
1.1
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia.
but not exceeding 300 mm dia. Cum 510 225.45 114,979.50

DSR ITEM Providing and fixing up to floor five level


NO 4.5 precast cement concrete string or lacing
courses, copings, bed plates, anchor
blocks, plain window sills, shelves, louvers,
steps, stair cases, etc. including hoisting
and setting in position with cement mortar
1:3 (1 Cement : 3 coarse sand), cost of
required centering, shuttering and
finishing smooth with 6mm thick cement
plaster 1:3 (1 Cement : 3 fine sand) on
exposed surfaces complete.
1.2
1:1.5:3 (1 cement : 1.5 coarse sand : 3
graded stone aggregate 20mm nominal
4.5.1 size). Cum 51 6772.45 345,394.95

Constructing masonary chamber 90 x 90


x100 cm. inside with 75 class designation
brickwork in cement mortar 1:5 ( 1 cement
: 5 fine sand) for sluice valve with CI
surface box 100 mm top dia. 180 mm
bottom dia. And 180 mm deep (inside)
with chained lid and RCC top slab 1:2:4 mix
( 1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) necessary
excavation foundation concrete 1 :5 :10 (1
cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size and inside
plastering with 1:3 (1 cement : 3 coarse
sand) 12 mm thick finished with a floating
coat of neat cement complete as per
standard design with FPS bricks
DSR Item
1.3 18.34.1 Each 11 11842.75 130,270.25

Sign and Stamp of EPIL 142 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Providing and fixing C.I. double acting air
valves of approved quality with bolts, nuts,
rubber insertions etc. complete ( The tail
pieces, tapers etc. if reqd. will be paid
1.4 18.59 separately)
1.4.1 18.59.1 50 mm dia. Each 9 4662.45 41,962.05

Providing & Fixing C.I.sluice valve(with cap)


complete with bolts,nuts,rubber insertions
etc.(the tail pieces if required will be paid
1.5 18.31 separately)
1.5.1 18.31.3 150 mm dia.pipe
1.5.1.1 18.31.3.2 Class II Each 11 5387.2 59,259.20

Y - STRAINER of Ductile CI Body flanged


ELECT. DSR ends with stainless steel strainer for
2016 / chilled / hot water circulation including
1.6 16.7.4 insulation as specified.
16.7.4.2 150 mm dia. Each 2 10530 21,060.00

NON - RETURN VALVE with duel plate of C I


body SS plates vulcanized NBR seal flanged
ELECT. DSR end & PN 16 pressure rating for chilled /
2016 / hot water circulation including insulation
1.7 16.11.2 as specified.
A 16.11.2.5 80 mm dia Each 2 2392 4,784.00
B 16.11.2.4 100 mm dia Each 2.00 3327 6,654.00
C 16.11.2.2 150 mm dia Each 10.00 5772 57,720.00
d 16.11.2.1 200 mm dia Each 1.00 8805 8,805.00

BUTTERFLY VALVE (MANUAL) with C I body


SS Disc, Nitrile Rubber Seal & O- Ring PN
ELECT. DSR 16 pressure rating for chilled water/ hot
2016 / eater circulation as specified
1.8 16.11.1
A 16.11.1.5 80 mm dia Each 2.00 3302 6,604.00
B 16.11.1.4 100 mm dia Each 2 4685 9,370.00
C 16.11.1.2 150 mm dia Each 8.00 5914 47,312.00
D 16.11.1.1 200 mm dia Each 1.00 10261 10,261.00

Providing and fixing in position the


industrial type Pressure Gauges with
ELECT. DSR gun metal / brass valves complete as
1.9 2016 / 16.8 required Each 4.00 973 3,892.00

TOTAL C/F TO SUMMARY 868,327.95


SUBHEAD-II(B):PIPING FOR FIRE FIGHTING SYSTEM (NON SCHEDULED ITEMS)

Sign and Stamp of EPIL 143 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Providing laying, testing & commissioning
of “C” class heavy duty MS pipe
conforming to IS 1239/3589 (all pipes shall
be ISI marked and of makes specified in
the specifications) i/c fittings like elbows,
tees, flanges, tapers, nuts bolts, gaskets
etc. in ground including excavation &
providing cement concrete blocks as
supports and anti-corrosive treatment to
burried pipes by wrapping & coating with 4
mm thk. (OR 2 COATS of 2mm thick tape)
anticorrosion tape along with two coat of
black japan primer for under-ground pipe
including digging and backfilling upto 1.0
mtr. below from G.L.for external work as
per IS-909 (Specification for Underground
Fire Hydrant Make: Jindal Hissar/ Surya/
Tata/ SAIL. (Under ground)

2.1
a M.R. 150 nominal bore (class C) M 440 1,883.95 828,939.02
b M.R. 100 nominal bore (class C) M 70 1,360.82 95,257.10

Providing, laying, testing & commissioning


of “C” class heavy duty MS pipe
conforming to IS 3589 and 1239 (all pipes
shall be ISI marked and shall be one of
approved makes) including fittings like
elbows, tees, flanges, tapers, nuts bolts,
gaskets etc. fixing the pipe on the
wall/ceiling with suitable clamps and
painting with two or more coats of
synthetic enamel paint of required shade
complete as per specificatipns and as
required. (Above Ground)
2.2
Note:
Threaded joint upto 50mm diameter pipe.
A
Welded joint above 50mm diameter pipe.
B
M.R. 250 mm nominal bore (class C - 9.5mm) Rm 25 5,009.92 125,248.11
a M.R. 200 mm nominal bore (class C - 9.5mm) Rm 25 4,073.56 101,839.11
b M.R. 150 mm nominal bore (class C) Rm 475 1,757.45 834,789.85
c M.R. 100 mm nominal bore (class C) Rm 977.76 1,228.57 1,201,242.40
d M.R. 80 mm nominal bore (class C) Rm 1079.56 861.24 929,761.93
e M.R. 65 mm nominal bore (class C) Rm 920.2 729.22 671,029.67
f M.R. 50 mm nominal bore (class C) Rm 904.6 572.52 517,897.77
g M.R. 40 mm nominal bore (class C) Rm 1142.5 420.10 479,967.87
h M.R. 32 mm nominal bore (class C) Rm 421 366.75 154,401.49
i M.R. 25 mm nominal bore (class C) Rm 6571.3 295.91 1,944,494.92

Sign and Stamp of EPIL 144 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Supply, installation, testing and
commissioning of 150 mm dia Installation
Control Valve inclusive of 2 nos 150 mm
dia Butterfly Valve, strainer, Alarm Valve
with Water Motor Gong, Pressure Gauges,
Test Lines with Ball Valves with necessary
GI (H) piping with threaded fittings of
required sizes complete
2.3 M.R. Set 1 56,511.00 56,511.00

Supply, installation, testing and


commissioning of 150 mm dia Zonal
Control Valve inclusive of 1 nos 150 mm
dia butterfly valve, 150mm diam. non
return valve, Flow Switch, water pressure
gauges & 25 mm dia. Auxillary Drain valve
with sight glass with necessary GI (H)
piping with threaded fittings of required
sizes complete
2.4 M.R. Set 12 49,447.13 593,365.50

Providing, fixing, testing and


commissioning of quick response 15 mm
dia. gunmetal quartz bulb type sprinkler
head to operate at 68 degree centigrade
2.5 M.R.
Side wall type Each 100 358.63 35,862.75
Pendent / Upright type Each 2056 336.89 692,650.98

Providing and fixing 25 mm dia, 1200mm


long flexible stainless steel (SS 304) pipe
for making final connection of sprinkler
head with sprinkler system piping network
including 2 nos. 25mm diameter G.I.
connector, G.I. Nipple, Reducer, elbow and
threaded jointing complete as per detail.

2.6 M.R. Each 546 1,756.63 959,117.25

TOTAL C/F TO SUMMARY 10,222,376.71

SUBHEAD- III (B): FIRE EXTINGUSHER (NON SCHEDULED ITEMS)

Providing and fixing carbon-di-oxide type


fire extinguishers consisting of welded
M.S. cylindrical body, internal discharge
tube, discharge nozzle, suspension
bracket, conforming to IS 2878, finished
externally with red enamel paint and fixed
to wall with brackets complete with
internal charges.
3.1 M.R.
a Capacity 4.5 kg Nos. 66 5,754.34 379,786.52

Sign and Stamp of EPIL 145 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)

Providing & Fixing of stored pressure Fire


Extinguisher ABC powder type (Mono
Ammonium Phosphate Powder) Magnetic
Pressure Gauge having the facility to check
at site, Discharge Time less than 9 Secs,
Controllable discharge mechanism, Range
minimum 4 Meters, applicable on Class
A,B,C and electrically started Fire, A Rating-
21A, B Rating 55B as per BS EN-3 BIS
15683 marked, Can Construction : Deep
drawn & CO2 Mig welded, Valve
Construction : Forging & Machining,
Internal Coating of Can : Epoxy Powder
coating, External Coating ofCan : Epoxy
Polyster Powder coating, Sheet metal
thickness : 1.60MM, Helium LeakDetection
Tested, Warranty.
3.2 M.R.
a Capacity 6 Kg. Nos. 66 2,097.43 138,430.22
Providing and fixing mechanical foam
type Trolley Mounted Fire Extinguisher
of bearing to
3.3 IS:10568/IS13385/IS13386 with dis
Capacity 50 Lit. Nos. 1 10,101.34 10,101.34
Providing and fixing Carbon Dioxide Type
Trolley Mounted Fire Extinguisher of as per
IS: 2878 with discharge time of 10 to 20
sec/15 to 36sec/20 to 60sec respectively.
3.4
22.5 Kg. CO2 Fire Extinguisher Nos. 1 16,708.78 16,708.78

TOTAL C/F TO SUMMARY 545,026.86


SUBHEAD-IV (B): FIRE ELECTRICAL WORKS (NON SCHEDULED ITEMS)

4.1 MR Fabricating, supplying, testing and


commissioning of electrical control panel
of cubicle construction, floor mounted
type, fabricated out of 2mm thick crca
sheet, compartmentallised and hinged
lockable doors, dust and vermin proof,
powder coated approved shade after 7
tank treatment process, cable alley
interconnection, having switchgears and
accessories mounting and internal wiring,
earth terminals, numbering etc., complete
in all respects, suitable for operation on
415V, 3 phase 50 Hz., AC supplywith
enclosure protection class IP-42as
required.
Set 1 381,225.00 381,225.00
A COMMON PANEL IN FIRE PUMP HOUSE.

Sign and Stamp of EPIL 146 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
(i) INCOMER
(a) 400 Amps. TP & N SFU with HRC fuses.
(b) Voltmeter (0-500 Volts) with selector
switch.
(c) Ameter (0- 400 Amps.) with selector
switch & CT's etc.
(d) Set of 3 phase indicating lamp.
(e) Set of Al. bus bar 200 Amps.
(ii) OUTGOING.
(a) Main fire pump and Sprinkler pump
200 Amps. TP& N SFU with HRC fuses with
suitable HP fully automatic star/delta
starter with over load protection, current
sensing type single phase preventor
complete with all acessories and internal
wiring required for automatic operation,
selector switch for local / remote, auto/
manual OFF operation.

(b) Jockey pump


40 Amps. TP& N SFU with HRC fuses with
suitable HP fully automatic star / delta
starter with over load protection, current
sensing type single phase preventor
complete with all accessories and internal
wiring required for automatic operation,
selector switch for local / remote, auto /
manual / OFF operation.

(c) Diesel Engine Control


Control for Diesel Engine comprising:-

Sign and Stamp of EPIL 147 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
(i) Auto / Manual selector switch & 3 attempt
starting device, timers and relays as
required, push buttons, start / stop in
manual mode.
(ii) Indication lamp for High / Low Lub. Oil
pressure, High Water Temp. and Engine
ON indication.
(iii) Battery charger suitable for 12V / 24 V DC
with boost and tickle selector switch, 0-30
V DC volt meter, 0-20A DC Ammeter.

(iv) All standard relays and acessories for


automatic operation of diesel engine.
B DIESEL ENGINE CONTROL
Control for Diesel Engine comprising:-
(a) Auto / Manual selector switch & 3 attempt
starting device, timers and relays as
required, push buttons, start / stop in
manual mode.
(b) Indication lamp for High / Low Lub. Oil
pressure, High Water Temp. and Engine
ON indication.
(c) Battery charger suitable for 12 V / 24 V DC
with boost and tickle selector switch, 0-15
V / 0-30 V DC volt meter, 0-20A DC
Ammeter.
C MAIN FIRE PUMP CONTROL
(a) 200 Amps. TP&N SFU with HRC fuses
(b) Voltmeter (0-500 Volts) with selector
switch.
(c) Ammeter (0-200 Amps.) with selector
switch, CTs etc.
(d) Set of 3 phase indication lamp.
(e) Suitable HP fully automatic Star / Delta
Starter with over load protection, current
sensing type single phase preventor
complete with all acessories and internal
wiring required for automatic operation.

(f) Selector switch for local / remote, auto /


manual / off operation.
D SYSTEM CONTROLLER
Designing, Supply, Installation, Testing and
Commissioning of system controller to
control operation of Main Electric Fire
Pump, Diesel Pump, Pressurisation Pump,
Terrace Pump in sequence as per
specification consisting of relays, timets,
sensors, annunciation window for fault
indication, complete as per specification.

TOTAL C/F TO SUMMARY 381,225.00

Sign and Stamp of EPIL 148 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
SUBHEAD- IV: FIRE ELECTRICAL WORKS (DSR 2016)

Supplying and Earthing with GI earth plate


600mm x 600 mm x 6mm thick including
accessories and providing masonary
enclosure with cover plate having locking
arrangement and watering pipe etc, with
charcoal/ coke and salt as required.
5.1 5.4 Set 5 4,327.00 21,635.00
Supplying and laying 25 mm x 5 mm. G.I.
strip in 40 mm dia. G.I. Pipe from earth
electrode, including connection with GI
nut, bolt, spring, washer excavation and re-
filling etc as required.
5.2 5.11 Rm 100 351.00 35,100.00
Providing & fixing 25mm x 5mm G.I. strip
on surface or in recess for connections
5.3 5.15 etc. as required. Rm 300 129.00 38,700.00
Providing and Fixing 6 SWG dia G.I. wire on
surface or in recess for loop earthing
alongwith existing surface/ recessed
conduit/ submain wiring/ cable as
5.4 5.18 required. Rm 435 23.00 10,005.00
Supplying, fabricating and installing
following size of perforated painted with
powder coating M.S. cable trays,with
perforation not more than 17.5%, in
covenient section, joined with connectors,
suspended from the ceiling with MS
suspenders including bolts & nuts, painting
suspenders etc. as required.
5.5 4.1
100 mm width X 50 mm depth X 1.6 mm
5.5.1 4.1.1 thickness Rm 70 348.00 24,360.00
300 mm width X 50 mm depth X 1.6 mm
5.5.2 4.1.4 thickness Rm 54 526.00 28,404.00
Laying and fixing of One number PVC
Insulated and PVC Sheathed/XLPE power
cable of 1.1 kV grade of size not exceeding
35 sqmm on surface as required.
5.6 7.7.1 RM 61 25.00 1,525.00
Laying and fixing of One number PVC
Insulated and PVC Sheathed/XLPE power
cable of 1.1 kV grade of folloing size on
wall surface as required.
5.7 7.7
Aboved 35 sq mm and upto 95 sq mm
7.7.2 (clamed with 25x3mm MS flat clam) RM 265 72.00 19,080.00

Sign and Stamp of EPIL 149 Sign and Stamp of Bidder


S. NO. (DSR-2016) DESCRIPTION UNIT QUT. RATE
Item NO (IN FIGURES) AMOUNT (IN RS.)
Supplying of all materials and making
terminations of 1.1 KV grade aluminium
multicore cables of the following sizes.
The work includes cable glanding using
brass plated double compression glands,
sizing the core leads, removing insulation,
fixing suitable crimping type copper lugs/
thimbles by using hydraulic crimping tools
with correct size of the dies, shaping the
leads and neatly connecting the same to
the equipment terminals.
5.8 9.1
3.5 Core 120 sq. mm. Armoured
5.8.1 9.1.25 Aluminium cable. Mtr 25 500.00 12,500.00
3.5 Core 35 sq. mm. Armoured Aluminium
5.8.2 9.1.21 cable. Mtr 155 282.00 43,710.00
3.5 Core 16 sq. mm. Armoured Aluminium
5.8.3 9.1.8 cable. Mtr 44 202.00 8,888.00

Control Cabling (PVC insulated and PVC


sheathed, armoured, Copper Conductor of
5.9 1.1 KV grade on existing cable trays).
MR 5C x 1.5 Sq. mm RM 180 160.00 28,800.00

TOTAL 272,707.00
Grand Total 16,058,225.56

Sign and Stamp of EPIL 150 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai
schedule of items : Plumbing Work - BOQ
S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
SUBHEAD-I (A): SANITARY INSTALLATIONS (As per D.S.R.2016)

1 17.1 Providing and fixing water closet squatting pan


(Indian type W.C. pan ) with 100 mm sand cast
Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with
manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required :
17.1.1 White Vitreous china Orissa pattern W.C. pan of
size 580x440 mm with integral type foot rests
Each 29 3,494.20 101,331.80

2 17.2 Providing and fixing white vitreous china pedestal


type water closet (European type W.C. pan) with
seat and lid, 10 litre low level white P.V.C. flushing
cistern, including flush pipe, with manually
controlled device
(handle lever), conforming to IS : 7231, with all
fittings and fixtures complete, including cutting
and making good the walls and floors wherever
required : Each 166 3,418.70 567,504.20
17.2.1 W.C. pan with ISI marked white solid plastic seat
and lid

3 17.7 Providing and fixing wash basin with C.I.brackets,


15 mm C.P. brass pillar taps, 32 mm C.P. brass
waste of standard pattern, including painting of
fittings and brackets, cutting and making good the
walls where required :

4 17.7.1 White vitreous china flat back wash basin size 630
x 450 mm with a pair of 15 mm C.P. brass pillar
taps. Each 163 2,298.55 374,663.65

5 17.7A Providing and fixing wash bashin with C.I. brackets,


15mm dia cp brass singal hole basin mixer of
approved quility and make, including painting of
fittings and brackets, cutting and making good the
walls wherever required -
a) White vitreous china wash basin size 550x400
mm with a 15 mm cp brass singal hole basin mixer.
Each 37 2984.2 110,415.40

6 8.10 Providing & fixing stone slab table rubbed, edges


rounded and polished of size 75 X 50cm deep and
1.8 cm thick fixed in urinal patitions by cutting
chase of appropriate width with chase cutter and
embedding the stone in chase with epoxy grout or
with cement concrete 1:2:4 ( 1 cement : 2 coarse
sand : 4 graded stone aggregste 6mm nominal
size) as per Engineer-in-charge and finished
smooth
8.10.1 White Agaria Marble Stone sqm 34 2,831.95 96,286.30

Sign and Stamp of EPIL 151 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
7 17.80 Providing and fixing white vitreous china battery
based infrared sensor operated urinal of approx.
size 610 x 390 x 370 mm having pre & post
flushing with water ( 250 ml & 500 ml
consumption), having water inlet from back side,
including fixing to wall with suitable brackets all as
per manufacturers specification and direction of
Engineer-in-charge.. Each 34 5,162.20 175,514.80

8 17.10 Providing and fixing Salem Stainless Steel A ISI 304


(18/8) kitchen sink as per IS: 13983 with CI
brackets and stainless steel waste with plug 40mm
including painting of fittings and brackets, cutting
and making good the walls wherever required.

17.10. Kitchen sink with drain board


1
17.10. 510X1040mm bowl depth 200mm.
1.3 Each 34 3,772.35 128,259.90
17.10.
2 Sink without drain board (For JC)
17.10.
2.1 610X510 mm bowl depth 200mm. Each 20 2,476.60 49,532.00

9 17.11 Providing and fixing white vitreous china


laboratory sink with C.I. brackets, C.P. brass chain
with rubber plug, 40 mm C.P brass waste and
40mm C.P. brass trap with necessary C.P. brass
unions complete, including painting of fittings and
brackets, cutting and making good the wall
wherever required :
17.11.
1 Size 450x300x150 mm Each 4 2,392.60 9,570.40

10 17.28 Providing & fixing PVC waste pipe for sink


oncluding PVC waste fitting Complete
17.28. Flexible Pipe
2
17.28. 32mm Dia
2.1 Each 58 73.25 4,248.50

11 17.32 Providing and fixing mirror of superior glass (of


approved quality) and of required shape and size
with plastic moulded frame of approved make and
shade with 6 mm thick hard board backing :

17.32. Rectangular shape 453x357 mm


1 Each 194 752.80 146,043.20

12.0 17.70 Providing and fixing PTMT Bottle Trap for Wash
basin and sink.
17.70. Bottle trap 31 mm single piece moulded with
1 height of 270 mm, effective length of tail pipe 260
mm from the centre of the waste coupling 77 mm
breadth with 25 mm minimum water seal,
weighing not less than 260 gms. Each 200 293.95 58,790.00

Sign and Stamp of EPIL 152 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
17.70.2 Bottle trap 38 mm single piece moulded with
height of 270 mm, effective length of tail pipe 260
mm from the centre of the waste coupling 77 mm
breadth with 25 mm minimum water seal,
weighing not less than 260 gms.(sink & urinal)
Each 92 305.55 28,110.60

14 17.71 Providing and fixing PTMT liquid soap container


109 mm wide, 125 mm high and 112 mm distance
from wall of standard shape with bracket of the
same materials with snap fittings of approved
quality and colour weighing not less than 105 gms.
Each 250 137.85 34,462.50

15.00 17.72 Providing & fixing PTMT towel ring trapezoidal


shape 215 mm long 200 mm wide with minimum
distance of 37 mm from wall face with concealed
fittings arrangement of approved quality and
colour weighing not less than 88 gms
Each 178 197.55 35,163.90

16.00 18.49 Providing and fixing C.P. brass bib cock of


approved quality confirming to IS:8931

18.49. 15mm nominal bore 371.70


1 Each 227 84,375.90

17 18.51 Providing and fixing C.P. brass long body bib cock
of approved quality conforming to IS standards
and weighing not less than 690 gms.

18.51. 15mm nominal bore 492.55


1 Each 58 28,567.90

18 18.53 Providing and fixing C.P. brass angle valve for


basin mixer and geyser points of approved quality
conforming to IS 8931 a) 15 mm nominal bore.

18.53. 15 mm nominal bore


1 Each 989 475.70 470,467.30

19.00 17.34 Providing and fixing toilet paper holder :


17.34. C.P. brass
1 Each 187 385.35 72,060.45

20 17.73 Providing and fixing PTMT towel rail complete


with brackets fixed wooden cleats with CP brass
screws with concealed fittings arrangement of
approved quality and colour.
17.73. 600 mm long towel rail with total length of 645
2 mm, width 78 mm and effective height of 88 mm,
weighing not less than 190 gms Each 90 422.7 38,043.00

21 17.16 Providing and fixing 8 mm dia C.P. / S.S. Jet with


A flexible tube upto 1 metre long with S.S. triangular
plate to Eureopean type W.C. of quality and make
as approved by Engineer - in-charge
Each 80 254.8 20,384.00

Sign and Stamp of EPIL 153 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
22 18.22 Providing and fixing CP Brass shower rose with 15
or 20 mm inlet
18.22. 100 mm diameter
1 Each 90 71.65 6,448.50

TOTAL 2,640,244.20
SUBHEAD-II(A): INTERNAL DRAINAGE INSTALLATIONS (As per D.S.R.2016)

1 Providing and fixing cast iron trap of self cleansing


design with cast iron screwed down or hinged
grating with or without vent arm complete,
including cost of cutting and making good the
walls and floors.
17.60. 100 mm inlet and 100 mm outlet centrifugally
1 cast (spun) iron S&S. Each 300 1,034.45 310,335.00
17.60. 100 mm inlet and 75 mm outlet centrifugally cast
2 (spun) iron S&S. Each 112 1,034.45 115,858.40

2 17.35 Providing and fixing soil, waste, vent and rain


water pipes
Centrifugally cast (spun) iron S&S pipe
100mm dia cast (spun) iron S&S pipe
17.35.
1.2 Rm 2257.5 921.65 2,080,624.88

3.0 17.37 Providing and fixing MS holder bat clamps of


approved design to cast iron (spun) pipe
embedded in and Including cement concrete
blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm
nominal size) including cost of cutting holes and
making good the walls etc.
17.37. For 100mm dia. Pipe
1 Each 717 140.65 100,846.05

4.0 17.38 Providing and fixing bend of required degree with


access door, insertion rubber washer 3mm thick,
bolts and nuts complete.
17.38. 100x100x100mm
1
17.38. Centrifugally cast (spun) iron pipe S&S
1.2 Each 480 384.90 184,752.00

5 17.39 Providing and fixing plain bend of required degree.

17.39. 100mm dia


1
17.39. Sand cast iron S&S as per IS : 3989
1.2 Each 312 307.10 95,815.20

6 17.40. Providing and fixing heel rest sanitary bend, in


1.2 100mm Centrifugally cast (spun) iron pipe S&S Each 178 370.95 66,029.10

7 17.42 Providing and fixing double equal plain junction of


required degree.
17.42. 100x100x100x100 mm
1
17.42. Sand cast iron S&S as per IS - 3989
1.2 Each 178 747.30 133,019.40

Sign and Stamp of EPIL 154 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
8 17.43 Providing and fixing single equal plain junction of
reqd. degree with access door, insertion rubber
washer 3mm thick, bolts and nuts complete.

17.43. 100x100x100mm
1
17.43. Standard cast (spun) iron pipe IS-3989
1.2 Each 178 623.00 110,894.00

9.00 17.44 Providing and fixing single equal plain junction of


required degree :
17.44. 100X100X100mm
1
17.44. Sand cast iron S&S as per IS - 3989
1.2 Each 178 575.40 102,421.20

10 17.48 Providing and fixing single unequal plain junction


of required degree
17.48. 100x 100x75 mm
1
17.48. Sand cast iron S&S as per IS -3989
1.2 Each 178 689.20 122,677.60

11 17.55 Providing and fixing door piece, insertion rubber


washer 3mm thick, bolts & nuts complete :

100 mm
17.55.
1
Providing and fixing door piece, insertion rubber
17.55. washer 3mm thick, bolts and nuts complete, in
1.2 100mm Centrifugally cast (spun) iron pipe S&S
Each 178 512.65 91,251.70

12 17.56 Providing and fixing terminal guard:


17.56. 100mm
1
17.56. Sand cast iron S&S as per IS - 3989
1.2 Each 57 333.80 19,026.60

13.00 17.57 Providing and fixing collar.


17.57. 100mm
1
17.57. Centrifugally cast (spun) iron pipe S&S
1.2 Each 57 351.20 20,018.40

14.00 17.65 Painting sand cast iron / centrifugally cast iron(


spun) iron soil, waste and vent pipes and fittings
with paint of any colour such as chocolate, grey or
buff etc. over a coat of primer (of approval quality)
for new work
17.65. 100mm dia cast (spun) iron S&S pipe
1 Rm 1144 40.65 46,503.60

15 18.28 Providing lead caulked joints to spun iron or C.I.


pipes and specials, including testing of joints but
excluding the cost of pig lead :
18.28. 100 & 150 mm diameter pipe
1 Each 7224 224.65 1,622,871.60

Sign and Stamp of EPIL 155 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
16 18.58 Providing and fixing PTMT grating of approved
quality and colour
18.58. Circular type
1
18.58. 100 mm nominal dia
1.1 Each 312 32.75 10,218.00

17.00 19.2 Providing and laying cement concrete 1:5:10 (1


cement: 5 coarse sand: 10 graded stone aggregate
40 mm nominal size) alround SW including bed
concrete as per standard design
Note: This work shall be done all-round CI pipe at
ground floor's toilet.
19.2.1 100mm diameter Rm 1113.5 622.95 693,654.83

18 19.18 Supplying and fixing C.I. cover without frame for


manholes :
19.18. 560 mm diameter C.I. cover (heavy duty) the
3 weight of the cover to be not less than 108 kg Each 5,891.20 -

19 12.41 Providing & fixing on wall face unplasticised -Rigid


PVC rain water pipes conforming to IS:13592
Tyape A included jointing with seal ring conforning
to IS:5382 leaving 10 mm gap for thermal
expansion. (i)Single socketed pipes.

12.41. 110 mm diameter Metre


2 1,146.00 231.65 265,470.90

20 12.42. Providing, fixing on wall face unplasticised - PVC


moulded fittings /accessories for unplasticised -
Rigid PVC rain water pipes conforming to IS ;
13592 Type A including jointing with seal ring
conforming to IS ; 5382 leaving 10 mm gap for
thermal expansion.
12.42. Coupler -110 mm diameter Each
1.2 52 138.30 7,191.60
12.42. Bend -87.5 deg -110 mm diameter Each
5.2 52 161.55 8,400.60
12.42. Shoe -110mm shoe Each
6.2 52 295.10 15,345.20

21 12.43 Providing & fixing unplasticised - PVC pipe clips of


approved design to unplasticised - PVC rain water
pipes by means of 50x50x50mm hard wood plugs,
screwed with .M.S. screws of required length
including cutting brick work and fixing in cement
mortar 1:4(1cement : 4 coarse sand) and making
good the wall etc. complete.

12.43. 110 mm dia Each


2 393 189.05 74,296.65

22 7760 P/F M.S. cap 100 mm dia Each 62 150.00 9,300.00

TOTAL 6,306,822.50
SUBHEAD-III(A): WATER SUPPLY INSTALLATIONS (As per D.S.R.2016)

Sign and Stamp of EPIL 156 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
1 17.30 Providing and fixing in position 25 mm diameter
mosquito proof coupling of approved municipal
design. Each 6 38.50 231.00

2 18.7 Providing and fixing CPVC pipes having thermal


stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including
fixing the pipe with clamps at 1.00 mt spacing. this
includes jionting of pipes and fittings with one step
CPVC solvent cement and testing of joints
complete as per direction of engineer in charge.

Internal work -Exposed on Wall


18.7.1 15 mm nominal outer dia pipes Rm 840 142.95 120,078.00
18.7.2 20 mm nominal outer dia pipes Rm 1260 179.95 226,737.00
18.7.3 25 mm nominal outer dia pipes Rm 1155 216.20 249,711.00
18.7.4 32 mm nominal outer dia pipes Rm 945 289.05 273,152.25
18.7.5 40 mm nominal outer dia pipes Rm 525 385.50 202,387.50
18.7.6 50 mm nominal outer dia pipes Rm 420 548.55 230,391.00

3 18.8 Providing and fixing CPVC pipes having thermal


stability for hot and cold water supply including all
CPVC plain and brass threaded fittings including
fixing the pipe with clamps at 1.00 mt spacing. this
includes jionting of pipes and fittings with one step
CPVC solvent cement and the cost of cutting
chases and making good the wall same including
testing of joints complete as per the direction of
engineer incharge
concealed work including cutting chases and
making good the wall etc.
18.8.1 15 mm nominal outer dia pipes Rm 2439.2 246.20 600,531.04
18.8.2 20 mm nominal outer dia pipes Rm 583.2 284.85 166,124.52
18.8.3 25 mm nominal outer dia pipes Rm 488 333.60 162,796.80
18.8.4 32 mm nominal outer dia pipes Rm 390.8 412.90 161,361.32

4 DSR Providing and fixing G.I. pipes complete with GI


Item fittings and clamps including cutting and making
18.10 good the walls etc. (internal work)
For roof level
18.10. 15 mm dia, nominal bore 215.10
1 Rm 20 4,302.00
18.10. 20 mm dia, nominal bore 249.30
2 Rm 40 9,972.00
18.10. 25 mm dia, nominal bore 304.15
3 Rm 100 30,415.00
18.10. 32 mm dia, nominal bore 343.20
4 Rm 150 51,480.00
18.10. 40 mm dia, nominal bore 425.65
5 Rm 125 53,206.25
18.10. 50 mm dia, nominal bore 527.20
6 Rm 180 94,896.00
18.12. 65 mm dia, nominal bore 524.25
7 Rm 157 82,307.25

5 DSR Painting with synthetic enamel paint of approved


Item drand and manufacture to give an even shade
13.61

Sign and Stamp of EPIL 157 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
13.61. Two more coast on new work 78.40
1 sqm 222.6 17,451.84

6 18.17 Providing and fixing of gun metal gate valve with


CI wheel of approved quality (screwed ends)

18.17. 25mm dia, nominal bore 428.20


1 Each 18 7,707.60
18.17. 32 mm dia, nominal bore 500.75
2 Each 8 4,006.00
18.17. 40 mm dia, nominal bore 584.70
3 Each 6 3,508.20
18.17. 50 mm dia, nominal bore 749.90
4 Each 6 4,499.40
18.17.5 65mm nominal bore Each 5 1286.80 6,434.00
18.17.6 80mm nominal bore Each 1 1919.50 1,919.50

7 18.19 Providing and fixing gun metal non- return valve of


approved quality (PN 1.6)
18.19. 80 nominal bore 2,944.55
6.2 Each 4 11,778.20

8.0 18.16 Providing and fixing brass stop cock of approved


quality
18.16. 15mm nominal bore
1 Each 102 260.00 26,520.00
18.16. 20mm nominal bore
2 Each 164 280.00 45,920.00

9.0 10.2 Structual steel work welded in built up sections,


trusses and framed work including cutting,
hoisting, fixing in position and applying a priming
coat of approved steel primer all complete.
kg 140 67.60 9,464.00

10.00 18.46 Providing and fixing G.I. union in G.I. pipe


including cutting and threading the pipe and
making long screws etc. complete (new work)
18.46. 15mm nominal bore 147.75
1 Each 24 3,546.00
18.46. 20mm nominal bore 170.95
2 Each 22 3,760.90
18.46. 25mm nominal bore 205.80
3 Each 22 4,527.60
18.46. 32mm nominal bore 240.65
4 Each 22 5,294.30
18.46. 40mm nominal bore 298.75
5 Each 22 6,572.50
18.46. 50mm nominal bore 384.90
6 Each 22 8,467.80

11.00 18.49 Providing and fixing C.P. brass bib cock of


approved quality confirming to IS:8931
18.49. 15mm nominal bore 371.70
1 Each 102 37,913.40

Sign and Stamp of EPIL 158 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
12 18.48 Providing and placing on terrace (at all floor levels) 7.25
polyethylene water storage tank, ISI : 12701
marked, with cover and suitable locking
arrangement and making necessary holes for inlet,
outlet and overflow pipes but without fittings and per
the base support for tank. litre 22000 159,500.00

13 18.33. Constructing masonry chamber 60x60x75 cm,


1 inside with 75 class designation brick work in
cement mortar 1:4 (1 cement:4 fine sand) for
sluice valve, with C.I. surface box 100mm, to
diameter, 160mm bottom diameter and 180mm
deep (inside) with chained lid and RCC top slab
1:2:4 mix (1 cement : 2 corase sand: 4 graded
stonr aggregate 20mm nominal size) necessary
excavation foundation concret 1:5:10 (1 cement:5
fine sand : 10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement
mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick
finished with a floating coat of neat cement
complete as per standard design.
Each 14 6,849.60 95,894.40

14 16.7.1 BUTTERFLY VALVE (MANUAL) with C I body SS


Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure
rating for chilled water/hot eater circulation as
specified
ELECT. 65 nominal bore
DSR
2016 /
16.7.1.
6
Each 14 3,351.00 46,914.00
ELECT. 80 nominal bore
DSR
2016 /
16.7.1.
5
Each 20 3,719.00 74,380.00
ELECT. 100 nominal bore
DSR
2016 /
16.7.1.
4
Each 6 5,330.00 31,980.00

15 ELECT. Providing, laying and fixing following dia G.I. pipe


DSR (medium class) in ground complete with G.I.
2016 / fittings including trenching (75 cm deep) and re-
14.13 filling etc. as required

14.13. 80 mm dia, NB
2 M 100 592.00 59,200.00
14.13. 100 mm dia, NB
3 M 56 828.00 46,368.00

TOTAL 3,443,607.57
SUBHEAD-III (B) : WATER SUPPLY- INTERNAL WORK (NON-SCHEDULED ITEMS)

Sign and Stamp of EPIL 159 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
16 M.R. Solar Water Heaters
Supply, erection, testing & commissioning of solar
water heating system with following details :

System temperature output : 60 degree C (during


clear sunny days)
System type : Thermo syphon
System : Non Pressurised
Application : Bathing / Washing / Cooking
Type of Solar Collectors : Copper tube Flat Plate
Collectors as per BIS with following specifications -

Size of Collector : 2080 x 1070 x 100 mm


Number of Collector : To suit system requirement.

Absorber area : 2 sq M
Type : Cu - Cu
Weight : 46 Kg (Dry)
Absorber Coating : Selective - NALSUN
Absorbivity : > 0.95
Emissivity : < 0.2
Frame Material : 16 SWG extruded Aluminium
Glazing : Toughened Glass
Glass beeding : EPDM
Finish : Painted by approved shade
Hot water return pump
Hardware : SS 304
Electrical heating back up required
Insulation : PUF
Collector Stand : 35x35x3 mm MS angle
Hot Water Tank : Cylindrical - vertical / horizontal,
Stainless steel 304 grade with 100 mm thick Rock
Wool insulation including 22 SWG aluminium
cladding.
The entire system should be complete with
internal piping in G.I. (class B) with 50 mm rock
wool insulation of density 48 kg/m3 with 26
SWG Al cladding, necessary isolation valves, Y type
CI strainer, hardwares, temperature gauge of
range 0 - 120oC, water meter, MS angle iron
structure of min thickness 3 mm duly painted etc
as required to complete the system in all respects.

The entire system should be approved by BIS as


per IS : 12933 and as per local regulations.
System Capacity : 4200 liters ( storage tank of
4200 litres ) per day (LPD) having 42 collectors.
ITEM 1 1,134,554.00 1,134,554.00
System Capacity : 600 liters ( storage tank of 600
litres ) per day (LPD) having 6 collectors. ITEM 3 163,941.00 491,823.00

Sign and Stamp of EPIL 160 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
17 MR Providing and fixing Double Faucet Storage type
Water Cooler ( Size 564 mm wide x 705 mm deep
x 1521 mm height, weight 88 kg) fully stainless
body having storage capacity of 150 ltrs, Cooling
Capacity of 150 Ltrs./hr., 2 nos of cold water outlet
with hermetic type compressor, gas cooled motor
equipped with over load protector, condensor for
propeller type, thermostat autometically
controlled temperature, refrigerent R -22, 230
volt, single phase 50 hertz, maximum current 6.8
amp including plug top and electrical lead wire
connection upto 3 metres from the cooler, water
inlet and drain out connections complete in all
respects of Voltas Model No 150/150 Tushar PSS
type or similar type of approved make.

Each 10 50,449.00 504,490.00

TOTAL 2,130,867.00

[1] EXTERNAL SEWERAGE SYSTEM


SECTION - IV SEWERAGE NETWORK

1 Providing laying and jointing glazed stoneware


pipes grade ‘A’ with stiff mixture of cement mortar
in the proportion of 1:1 (1 cement : 1 fine sand)
including testing of joints etc. complete.

19.1.2 150 mm diameter metre 10.00 327.05 3,270.50


19.1.4 250 mm diameter metre 585.00 692.50 405,112.50

2 19.2 Providing and laying cement concrete 1:5:10 (1


cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) alround SW pipes
including bed concrete as per standard design.

19.2.2 150 mm diameter metre 5.00 761.85 3,809.25


19.2.4 250 mm diameter metre 585.00 1027.00 600,795.00

3 19.11 Constructing brick masonry circular manhole 1.22


m internal dia at bottom and 0.56 m dia at top in
cement mortar 1:4 (1 cement :4 coarse sand)
inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement foundation
concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size) and
making necessary channel in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a
floating coat of neat cement, all complete as per
standard design :

Sign and Stamp of EPIL 161 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
19.11.1 1.68 m deep with SFRC Cover and frame (heavy
duty HD-20 grade designation) 560 mm internal
diameter conforming to I.S. 12592, total weight of
cover and frame to be not less than 182 kg. fixed
in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal
size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement
plaster at the external surface shall be paid for
separately) :

19.11.1.2With Sewer bricks conforming IS : 4885 each 2.00 16720.90 33,441.80

4 19.12 Extra depth for circular type manhole 1.22 m


internal dia (at bottom) beyond 1.68 m to 2.29 m :

19.12.2 With Sewer bricks conforming IS : 4885 metre 2.00 6505.15 13,010.30

5 Constructing brick masonry manhole with F.P.S.


bricks in cement mortar 1 : 4 (1 cement : 4 coarse
sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2
coarse sand : 4 grade stone aggregate 20mm
nominal size); foundation concrete 1:4:8 mix (1
cement : 4 coarse sand : 8 graded stone
aggregate 40 mm nominal size) inside plastering
12 mm thick with cement mortar 1:3 (1cement 3
coarse sand ) finished with a floating coat of neat
cement and making channels in cement concrete
1:2:4 (1cement : 2 coarse sand: 4 graded stone
aggregate 20 mm nominal size) finishd with a
floating coat of neat cement complete as per
standard design

19.7.1. Inside size 90 x 80 cm & 45 cm deep including CI


1 cover with frame (light duty) 455 x 610mm
internal dimension total wt. of cover & frame to
be not less than 38 kg (wt. of cover 23 kg and wt.
of frame 15 kg)
each 45.00 8,634.10 388,534.50

6 Extra for depth for manhole with F.P.S. bricks


19.8.1.1size 90 X 80 cm m 18.00 5,718.60 102,934.80

7 19.15 Providing M.S. foot rests including fixing in


manholes with 20x20x10 cm cement concrete
blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) as per
standard design
19.15. With 20x20 mm square bar
1 Each 25.00 267.95 6,698.75

8 7087 Providing and fixing C.I. tee 150mm at the inlet


and outlet of septic tank. Each 3.00 600.00 1,800.00

9 17.35 Providing and fixing soil, waste and vent pipes :

Sign and Stamp of EPIL 162 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
17.35. Providing & fixing 75mm dia vent pipes.
2.1 Rm. 20.00 712.20 14,244.00

10 17.56 Providing and fixing terminal guard :


17.56. Providing & fixing of 75mm dia cast iron terminal
2.1 guard. Each 3.00 197.10 591.30

11 19.19 Providing and fixing in position precast RCC


manhole cover and frame of required shape and
approved quality.
19.19. M.D. -10- Circular shape 500mm internal diameter
2.2 Each 3.00 908.35 2,725.05

12 19.16 Providing orange colour safety foot rest of


minimum 6 mm thick plastic encapsulated as per
IS : 10910, on 12 mm dia steel bar conforming to
IS : 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm
and width as 165 mm with minimum 112 mm
space between protruded legs having 2 mm tread
on top surface by ribbing or chequering besides
necessary and adequate anchoring projections on
tail length on 138 mm as per standard drawing
and suitable to with stand the bend test and
chemical resistance test as per specifications and
having manufacture's permanent identification
mark to be visible even after fixing, including fixing
in manholes with 30x20x15 cm cement concrete
block 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) complete as
per design.

each 22.00 311.60 6,855.20

13 Providing and fixing square mouth SW gully trap


grade ‘A’ complete CI grating brick masonry
chamber with bricks of class designation 75 and
water tight CI cover with frame of 300 x 300 mm
size (inside) the weight of cover to be not less than
13.00 kg and frame to be not less than 5 kg. as per
standard design. (COVER MIN. 4.5 KG & FRAME
MIN.2.7 KG )

19.4.3.1180x150 mm size P type With FPS bricks each 31.00 1664.80 51,608.80

14 19.32 Making soak pit 2.5 m diameter 3.0 metre deep


with 45 x 45 cm dry brick honey comb shaft with
bricks of class designation 75 and S.W. drain pipe
100 mm diameter, 1.8m long complete as per
standard design.
19.32. With F.P.S. bricks
1 Each 2.00 20,681.55 41,363.10

Sign and Stamp of EPIL 163 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
15 19.21. Making connection of drain or sewer line with
1 existing manhole including breaking into and
making good the walls, floors with cement cincrete
1:2:4 mix (1cement: 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) cement plastered
on both sides with cement mortar 1:3 (1cement : 3
coarse sand) finished with a floating coat of neat
cement and making necessary channels for the
drain etc. complete for pipes 100 to 230mm dia.
Item 1.00 364.60 364.60

TOTAL 1,677,159.45

[2] EXTERNAL DRAINAGE SYSTEM


SECTION - V DRAINAGE NETWORK

1 19.6 Providing and laying non-pressure NP2 class (light


duty) RCC pipes with collars jointed with stiff
mixture of cement mortar in the proportion of 1:2
(1 cement : 2 fine sand) including testing of joints
etc. complete. (for storm drainage)

19.6.2 150 mm dia RCC pipe Meter 95.00 356.70 33,886.50


19.6.3 250 mm dia RCC pipe Meter 195.00 482.05 93,999.75
19.6.4 300 mm dia RCC pipe Meter 155.00 518.55 80,375.25
19.6.5 450 mm dia RCC pipe Meter 85.00 720.95 61,280.75
19.6.7 600 mm dia RCC pipe Meter 5.00 1,397.10 6,985.50

2 Constructing brick masonry road gully chamber


50x45x60 cm with bricks of class designation 75 in
cement mortar 1:5 (1 cement : 5 fine sand)
including 500 x 450 mm (heavy duty) precast RCC
horizontal grating with frame complete as per
standard design:
19.27. with FPS bricks
1 Each 42.00 4,043.10 169,810.20

3 19.1 Providing, laying and jointing glazed stoneware


pipes grade 'A' with stiff mixture of cement mortar
in the proportion of 1:1 (1 cement: 1 fine sand)
including testing of joints etc. complete:

19.1.3 200 mm diameter R.M. 12.00 423.35 5,080.20


4 23.7 Supplying, filling, spreading & leveling coarse sand
of size range 1.5 mm to 2 mm in recharge pit, in
required thickness over gravel layer, for all leads &
lifts, all complete as per direction of Engineer –in-
charge. Cu.M 3.54 1038.05 3,674.70

5 19.19 Providing and fixing in position pre-cast R.C.C.


manhole cover and frame of required shape and
approved quality
19.19.1 L D- 2.5
19.19.1.1Rectangular shape 600x450mm internal
dimensions Each 8.00 1,073.05 8,584.40

Sign and Stamp of EPIL 164 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
6 23.1 Boring/drilling bore well of required dia for
Casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and
submitting strata chart/bore log, including hire &
running charges of all equipments, tools, plants &
machineries required for the job, all complete as
per direction of Engineer –in-charge, upto 90
metre depth below ground level.

23.1.1 All types of soil


23.1.1.1300 mm dia. R.M. 40.00 370.70 14,828.00

7 23..3 Supplying, assembling, lowering and fixing in


vertical position in bore well, unplasticized PVC
medium well casing (CM) pipe of required dia,
conforming to IS: 12818, including required hire
and labour charges, fittings & accessories etc. all
complete, for all depths, as per direction of
Engineer –in-charge.
23.3.2 150 mm nominal size dia. R.M. 50.00 572.30 28,615.00

8 23.6 Supplying, filling, spreading & leveling gravels of


size range 4.6 mm to 4.8 mm, in the recharge pit,
over the existing layer of boulders, in required
thickness, for all leads & lifts, all complete as per
direction of Engineer-in-charge.
Cu.M 9.80 1038.05 10,172.89

9 23.5 Supplying, filling, spreading & leveling stone


boulders of size range 5 cm to 20 cm, in recharge
pit, in the required thickness, for all leads & lifts,
all complete as per direction of Engineer-in-
charge. Cu.M 9.80 921.90 9,034.62

TOTAL 526,327.76

SECTION- VI CIVIL WORKS

1 2.6 Earth work In excavation by mechanical means


(Hydraulic excavator)/manual means over areas
(exceeding 30cm in depth. 1.5m in width as per as
10 sq.m on plan) including disposal of excavated
earth, lead up to 50m and lift up to 1.5m, disposed
earth to be levelled and neatly dressed.

2.6.1 All kinds of soil Cu.M 106.80 125.95 13,451.46

2 2.6.1& In all kind of soil upto 1.5m to 3.0m. depth


2.26 Cum 66.01 177.70 11,729.41

3 2.25 Filling available excavated earth (excluding rock) in


trenches, plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating Each
deposited layer by ramming and watering , lead up
to 50 m and lift up to 1.5m.
Cu.M 62.50 125.75 7,859.38

Sign and Stamp of EPIL 165 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
4 2.26 Extra for every additional lift of 1.5 m or part there
of in:
(a) Depth exe. 1.5m but not exceeding 3.0m. Cu.M 52.50 51.75 2,716.88
(b) Depth exe. 3.0m but not exceeding 4.5m. Cu.M 30.10 51.75 1,557.68

5 4.1 Providing and laying in position cement cncrete of


specified grade excluding the cost of centring and
shuttering - all work upto plinth level.
4.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) Cum 15.00 5,481.95 82,229.25
4.1.8 1:4:8 (1 cement :4 coarse sand : 8 graded stone
aggregate 40 mm nominal size) Cu.M 2.40 4,478.15 10,747.56

4.1.10 1:5:10 (1 cement : 5 coarse sand : 10 graded ston


aggregate 40 mm nominal size) CUM 133.75 4,209.05 562,960.44

6.00 2.10 Excavating trenches of required width for pipes,


cables etc. including excavation for sockets and
dressing of sides, ramming of bottom depth upto
1.5 M including getting out the excavated soil
(HARD OR SOFT) and then returning the soil as
required in layers not exceeding 20 cms in depth
including consolidating each deposited layer by
ramming, watering etc. and disposing of surplus
excavated soil as directed within a lead of 50m.
[hard/Dense soil]

2.10.1 All kind of soil


2.10.1.2Pipes,cables etc.exceeding 80mm dia.but not
exceeding 300mm dia. Mtr. 1331.00 225.45 300,073.95

7.00 DSR 2.11Extra for excavating trenches for pipes, cables etc.
in all kinds of soil for depth exceeding 1.5m,but
not exceeding 3 m.(Rate is over corresponding
basic item for depth up to 1.5 metre).
Mtr. 89.50 324.42 29,035.59

8 5.3 Reinforced cement concrete work in slab with


1:2:4 (1 cement : 2 course sand : 4 graded stone
aggregate 20mm normal size). Cum 12.00 7,390.80 88,689.60

9 5.9 Centring and shuttering including strutting,


proppintg etc. and removal of form for:
5.9.3 Suspended floors,roofs, landings, balconies and
access platform. Sq.M 83.50 422.30 35,262.05

10 5.9.16 Edges of slabs and breaks in floors and walls, 0.00


5.9.16.1Under 20 cm wide R.M. 37.12 122.20 4,536.06

11 5.22 Steel reinforcement for R.C.C. work including


straightening, cutting, bending, placing in position
and binding all complete upto plinth level.

5.22.6 Thermo Mechanically Treated bars. Kg. 1296.10 56.60 73,359.26

Sign and Stamp of EPIL 166 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
12 5.33 Providing and laying in position machine batched
and machine mixed design mix M-25 grade
cement concrete for reinforced cement concrete
work, using cement content as per approved
design mix, including pumping of concrete to site
of laying but excluding the cost of centering,
shuttering, finishing and reinforcement, including
admixtures in recommended proportions as per IS:
9103 to accelerate, retard setting of concrete,
improve workability without impairing strength
and durability as per direction of Engineer-in-
charge.

(Note :- Cement content considered in this item is


@ 330 kg/cum. Excess/less cement used as per
design mix is payable/recoverable separately).

5.33.1 All works upto plinth level. Cu.M 7.56 6,446.45 48,735.16

13 6.1 Brick work with F.P.S. bricks of class designation


75 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand) Cu.M 58.80 4,970.30 292,253.64

14 13.1.1 12 mm thick cement plaster of mix 1:4 (1 cement :


4 fine sand). Cum 90.00 172.95 15,565.50

15 13.5 15 mm cement plaster on rough side of single or


half brick wall of mix
13.5.1. 1:4 (1 cement: 4 coarse sand)
Sqm 150.00 209.65 31,447.50

16 2.8 Earth work in excavation by mechanical means


(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5m
in width or 10 Sq.M on plan) including dressing of
sides and ramming ob bottoms, lift upto 1.5m,
including getting out the excavated soil and
disposal of surplus excavated soil as directed,
withen a lead of 50m.

2.8.1 All kinds of soil Cu.M 118.34 166.40 19,691.78

17 9.50 Providing and fixing hard drawn steel wire fabric


75x25 mm mesh of weight not less than 7.75 Kg
per sqm to window frames etc. including 62x19
mm beading of second class teak wood and
priming coat with approved steel primer all
complete. Sq.M 18.84 1,054.00 19,857.36

TOTAL 1,651,759.49

EXTERNAL WATER SUPPLY SYSTEM


SECTION- VII DISTRIBUTION NETWORK FOR FRESH WATER
SUPPLY
(D.S.R. 2016 ITEMS)

Sign and Stamp of EPIL 167 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
1 18.12 Providing and fixing G.I. pipes complete with G.I.
fittings including ,trenching and refilling etc.

external works
18.12.1 15mm nominal bore RM 20 160.20 3,204.00
18.12.2 20mm nominal bore RM 20 186.30 3,726.00
18.12.6 50mm nominal bore RM 550 342.70 188,485.00
18.12.7 65mm nominal bore RM 65 451.70 29,360.50
18.12.8 80mm nominal bore RM 50 576.30 28,815.00

2.00 DSR Painting GI pipes and fittings with two coats of anti
Item corrosive bitumastic paint of approved quality
18.40
18.40. 15 mm dia, nominal bore 6.00
1 Rm 20 120.00
18.40. 20 mm dia, nominal bore 7.10
2 Rm 20 142.00
18.40. 50 mm dia, nominal bore 14.80
6 Rm 550 8,140.00
18.40. 65 mm dia, nominal bore 18.25
7 Rm 65 1,186.25

3.0 Providing and filling sand of grading zone V or


coarser grade all-round the G.I. pipes in external
work.
18.41.1 15mm nominal bore RM 20 66.80 1,336.00
18.41.2 20mm nominal bore RM 20 67.70 1,354.00
18.41.6 50mm nominal bore RM 550 74.95 41,222.50
18.41.7 65mm nominal bore RM 65 118.30 7,689.50
18.41.8 80mm nominal bore RM 50 121.90 6,095.00
18.41.9 100 mm nominal bore RM 30 129.10 3,873.00
18.41.10150 mm nominal bore RM 0 192.30 -

4.0 Providing and fixing C.I. double acting air valve of


approved quality with bolts, nuts, rubber
18.59 insertions etc. complete (The tail pieces, tapers etc
if required will be paid separately) :

18.59. 50 mm dia
1 Each 4 4662.45 18,649.80
18.59. 80 mm dia
2 Each 1 5649.75 5,649.75
18.59. 100 mm dia
3 Each 1 7410.80 7,410.80

5.0 18.31.1 Providing & Fixing C.I.sluice valve(with cap)


complete with bolts,nuts,rubber insertions etc.(the
tail pieces if required will be paid separately)

18.31.1. 100 mm dia.pipe


1 Each 3 3317.55 9,952.65
18.31.3. 150 mm dia.pipe
1 Each 0 4881.25 -

Sign and Stamp of EPIL 168 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
6.0 18.32. Constructing masonry chamber 30x30x50
1 cm,inside with 75 class designation brick work in
cement mortar 1:4 (1 cement:4 coarce sand) for
stop cock complete with C.I. surface box
100x100x75mm (inside) with locking arrangement
and RCC top slab 1:2:4 mix (1 cement : 2 corase
sand: 4 graded stonr aggregate 20mm nominal
size) necessary excavation foundation concret
1:5:10 (1 cement:5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside
plastering with cement mortor 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a floating
coat of neat cement complete as per standard
design.
Each 10 1,195.35 11,953.50

7.00 18.13. Making connection of GI distribution branch with


2 GI main of 50-80mm nominal bore by providing
and fixing tee, including cutting and threading the
pipe etc. complete. Item 4 771.20 3,084.80

8.00 Providing & fixing of Garden hydrant outlet


consisting 1 No. 20mm dia. Ball valve, Bib cock
(Brass) for connecting rubber hose, pipes &
fittings including brick masonary chamber
300x300x500mm.
18.15 Bib Cock - 20mm 280.40 -
18.18 Ball Valve - 20mm 327.05 -
TOTAL Each 8 607.45 4,859.60

9.00 NON - RETURN VALVE with duel plate of C I body


SS plates vulcanized NBR seal flanged end & PN 16
16.7.3 pressure rating for chilled / hot water circulation
including insulation as specified.

ELECT. 100 nominal bore 4 3,893.00


DSR
2014 /
16.7.3.
4
Each 15,572.00
ELECT. 80 nominal bore 8 2,811.00
DSR
2014 /
16.7.3.
5
Each 22,488.00

10.00 17.30 Providing and fixing in position 25 mm diameter 6 38.50


mosquito proof coupling of approved municipal
design. Each 231.00

TOTAL 424,600.65

SECTION- VIII PUMPS( NON SCHEDULED ITEMS)

1 Mr Raw Water Treatment Feed Pump set Set 1 327,267.00 327,267.00

Sign and Stamp of EPIL 169 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Providing, fixing, commissioing and testing
package vertical raw water pumps, comprising of
Electrical Driven inline pumping with all
accessories, Pumps shall be with C.I. Base, S.S 304,
impeller, shaft, mechanical seal, S.S. Shaft directly
coupled to motor suitable for operation on
400/440 volts, 3 phase 2900 RPM. TEFC electronic
motor mounted on a common channel baseplate
150mm dia pressure gauge, GM isolation cock and
cement concrete foundation with plaster with
dunlop cushy foot mountings with all accessories
such as NRVs, valves, pressure guage bourden
type, common suction and delivery header,
bellows on sucton and delivery side complete in all
repsects.

Pumps shall be suitable for 415 ± 10% volts 3


phase 50 Hz A.C supply & shall be having the
following requirement complete with foundation
and associated civil works.
Suction & Delivery Header - SS 304
Control Valve On suction and Delivery - Ball Valve
Only (No Butterfly Valve Accepted).
Flow Prevention - Only Check Valve
Suction & delivery header including all pipes,
suction & delivery sides valves, NRV, Pressure
gauges & accessories complete.
Flow Rate : 7.0 LPS (1 working + 1 stand by)
Head : 35 M
Min. Motor HP : 7.5 H.P. (Each)

2 Mr Water Booster Pumpset (Treated Water Supply)


Set 1 897,345.00 897,345.00
Supplying & supervision of testing &
commissioning of Booster Pumpset
(Hydropneumatic systems) as described below
Supplying & supervision of testing &
commissioning of package vertical
Hydropneumatic system, comprising of 2.0 nos. (1
duty + 1 stand by) Electrical Driven inline pumping
sets each of 7.0 LPS to a head to 80 meter with
all accessories, Pumps shall be with C.I. Base, S.S
304, impeller, shaft, mechanical seal, S.S. Shaft
directly coupled to motor suitable for operation on
400/440 volts, 3 phase 2900 RPM. TEFC electronic
motor mounted on a common channel baseplate
150mm dia pressure gauge, GM isolation cock and
cement concrete foundation with plaster with
dunlop cushy foot mountings with all accessories
such as NRVs, valves, pressure switch, common
suction and delivery header, bellows on sucton
and delivery side complete in all repsects.

Sign and Stamp of EPIL 170 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Pump mounted or wall mounted microprocessor
based controller, Electronic control panel with
frequency inverter, logic controller relays, pressure
sensor, pressure sensor transmitter, electrical
wiring, cabling from panel to pumps, level
controller, two lined LCD display, diodes to
indicate pump ready, pump running and fault
capable to communicate with toher RS 485
interface. with Power box equipped with fuses or
isolators or circuit breakers as required. complete
with all accessories as per manufacturer
specifications.

Suction & Delivery Header - SS 304


Control Valve On suction and Delivery - Ball Valve
Only (No Butterfly Valve Accepted).
Flow Prevention - Only Check Valve
One Number Variable frequency Drive
Impeller : Stainless Steel
Shaft : Stainless Steel
RPM : 2900.
Mover : Electric Motor
HP - As required.
Necessary foundation with bolts
Ball valve on suction & delivery
NRV on delivery
Dust & vermin proof cubicle type motor control
centre fabricated from powder coated 16 SWG MS
sheet suitable to automatic working of above
mentioned pumps.

Sign and Stamp of EPIL 171 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
3 Mr Sump Pumps
Supply & Installation, testing and commissioning
of centrifugal non clogging submersible sump
pumps for plant room drainage. Pump capable
capable of handling 25 mm dia soft solids. Motor
suitable for 415 + 10% volts, 3 phase, 50 Hz AC
Power supply. Pumps shall be suitable for
automatic/manual operation (Overall depth of
sump – 1.5 M). Submersible sump pump shall be
provided with dry running protection. Inclusive of
supporting arrangement for stationary type.

Two nos. of pump installed in one sump pit 1


working & 1 standby with automatic/manual
opration as requireds.

Waste Water Drainage Sump Pump (PLANT


ROOM) Each 2 68,621.00 137,242.00
Flow rate : 2 LPS
Head : 10 Mtrs.
Min. Motor HP : 2.0 (Each)

4 Mr Supply & installation, testing & commissioning of


sand filter having FRP pressure vessel suitable for
test pressure of 7 Kg. / cm2 including valves for
back-wash arrangement complete with initial
charge of media to remove the total suspended
particles from the water.

Capacity : 7.0 LPS


Working Pressure : (5 ± 2.5)MWC Each 1 269,204.00 269,204.00

5 Mr Supplying, storing, handling, installation, testing &


commissioning of Activated Carbon Filter having
FRP pressure vessel suitable for test pressure of 7
Kg./cm2 including valves for back-wash
arrangement complete with initial charge of media
to remove the total suspended particles from the
water.
Capacity : 7.0 LPS
Working Pressure : (5 ± 2.5)MWC Each 1 290,318.00 290,318.00

6 Mr Supplying, storing, handling, installation, testing &


commissioning of water softening system having
FRP pressure vessel suitable for test pressure of 7
Kg/cm2 including dished end, ion- exchange resin,
Frontal piping, C.I. diaphragm type valve, brine
injection assembly for regeneration of softener,
brine measuring cum salt water tank, inter
connected flexible polypropylene MS Rubber lined
(MSRL) piping, valves including provision of bye-
pass arrangement complete with inside and
outside painting etc. as required.

Receiving, storing, handling and fixing of


PVC/HDPE/FRP tank for Brine solution along with
Hydraulic Injector with control valve and piping
for brine injection.
Capacity : 7.0 LPS

Sign and Stamp of EPIL 172 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Working Pressure : (5 ± 2.5)MWC Each 1 448,673.00 448,673.00

7 Mr Supplying and fixing of PVC/HDPE/FRP tank


including electrical operated metering/dosing
pump for dosing of alum/sodium hypo-chlorite
solutions in pipeline (all contacting parts shall be
of stainless steel). Capacity - 0-12 LPH Each 1 34,839.00 34,839.00

8 Mr Supplying & fixing of float based visual flow meter


(Rotameter) suitable for water flow rate of 25200
litres per hour in the input line of water softener
including matching flanges, nuts, bolts and 3 mm
thick rubber insertions/gaskets complete. to
assess the water flow rate in water softener.
Each 1 23,460.00 23,460.00

TOTAL 2,428,348.00

SECTION- IX ELECTRICAL WORKS (NON SCHEDULED ITEMS)

1 MR CUBICAL PANEL BOARD - PLUMBING PH Item 1 250,728.75 250,728.75


i) For 2 x 7.5 HP Filter Feed Pumps (1 duty + 1
stand by)
ii) For 2 x 18.0 HP Treated Water Transfer Pumps
Set (1 Duty + 1 Stand by) - (only isolator).

iii) For 2 x 2.0 HP Waste Sump Pumps pump room


(1 Duty + 1 Stand by) - (only isolator). - Pump room

iv) For 3 x 3.7 HP Bore well Pump (only isolator).

Supply, installation, testing and commissioning of


Cubical type sectionalised floor standing switch
board of 31 MVA fault capacity at 415 V complete
with 3.5 strip, 160 A capacity Aluminium Bus - Bar
Electrolytic grade, cable alley, switchgears of
following capacity & as per specifications.

A) INCOMER
100 A TP MCCB with heavy duty solid neutral link
with (0-100A) ammeter with 3 CT and selector
switch, (0 - 500 V) voltmeter with selector switch,
phase indication light with protection fuse. - 01
Set

B) OUTGOINGS
i) For 2 x 7.5 HP Filter Feed Pumps
12 A TP MCB with 10 A DOL starter, overload
relay, 96 mm (0-25A) ammeter with single CT,
start / stop push buttons, on / off / trip indication
lights with protection fuse, single phase preventer.
- 01 set.

ii) For 2 x 18.0 HP Treated Water Transfer Pumps


(H.S)
40.0 A TP MCB with isolator

Sign and Stamp of EPIL 173 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
iii) For 2 x 2.0 HP Waste Water Transfer Pumps -
only feeder to sub panels.
12 A TP MCB with 10 A DOL starter, overload
relay, 96 mm (0-25A) ammeter with single CT,
start / stop push buttons, on / off / trip indication
lights with protection fuse, single phase preventer.
- 01 set.
iv) For 3.0 No. - 3.7 HP Borewell Pump
32 A TP MCB with isolator

NOTE :
i) All the drainage pumps shall be work cyclic
process i.e. in first operation duty pump work on
duty and stand by pump duty pump work on stand
by and stand by pump work as duty pump.

ii) The drainage Stand by pumps automatically


work as drainage assist pump for Duty pump when
level of water rises in drainage sump pumps i.e.
Both pumps can work at a time & operation shall
be controlled with the help of level controllers and
float switches.

TOTAL 250,728.75

2 POWER & CONTROL CABLING (DSR 2016


SCHEDULED ITEMS)

2.1
Supplying and Earthing with GI earth plate 600mm
x 600 mm x 6mm thick including accessories and
providing masonary enclosure with cover plate
having locking arrangement and watering pipe
DSR etc, with coke and salt ) as required.
5.3 Set 2.0 3,583.00 7,166.00
2.2 Supplying and laying 25 mm x 5 mm. G.I. strip in
40 mm dia. G.I. Pipe from earth electrode, as
required.
5.11 Rm 40.0 351.00 14,040.00
2.3 Providing & fixing 25mm x 5mm G.I. strip on
surface or in recess for connections etc. as
required.
5.15 Rm 200.0 129.00 25,800.00
2.3.1 Providing and Fixing 6 SWG dia G.I. wire on surface
or in recess for loop earthing alongwith existing
surface/ recessed conduit/ submain wiring/ cable
as required.
5.18 Rm 300.0 23.00 6,900.00
2.3.2 Supplying, fabricating and installing following size
of perforated M.S. cable trays, including horizontal
and vertical bends, reducers, tees, cross members
and other accessories as required and duly
suspended from the ceiling with M.S. suspenders
4.1 and including paint

4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness Rm 40.0 348.00 13,920.00


2.4
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Rm 30.0 526.00 15,780.00

Sign and Stamp of EPIL 174 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
2.4.1 Laying and fixing of One number PVC Insulated
and PVC Sheathed/XLPE power cable of 1.1 kV
grade of size not exceeding 25 sqmm on surface as
7.7.1 required. RM 25.0 25.00 625.00
Laying and fixing of One number PVC Insulated
and PVC Sheathed/XLPE power cable of 1.1 kV
grade of size exceeding 25 sqmm but not
exceeding 120 sqmm on surface as required.
7.7.3 RM 240.0 84.00 20,160.00

Supplying of all materials and making terminations


of 1.1 KV grade aluminium multicore cables of the
following sizes. The work includes cable glanding
using brass plated double compression glands,
sizing the core leads, removing insulation, fixing
suitable crimping type copper lugs/ thimbles by
using hydraulic crimping tools with correct size of
the dies, shaping the leads and neatly connecting
the same to the equipment terminals.

9.1.25 3.5 Core 120 sq. mm. Armoured Aluminium cable. Nos 10.0 500.00 5,000.00
2.5
9.1.21 3.5 Core 35 sq. mm. Armoured Aluminium cable. Nos 80.0 282.00 22,560.00

Control Cabling ( PVC insulated and PVC sheathed,


armoured, Copper Conductor of 1.1 KV grade on
existing cable trays).
MR 5C x 1.5 Sq. mm RM 150.0 160.00 24,000.00

TOTAL 155,951.00

SECTION - X TECHNOLOGY - SBR (120+25 = 145 KLD)


Technology

A EFFLUENT TREATMENT PLANT - 25 KLD

Design, Supplying, Installing, Testing &


Commissioning of Effluent Treatment Plant of
Capacity 25 KLD. The plant proposed shall be with
a common pump room. The plant is proposed to
be installed in the basement accessible from the
pump room itself for future maintenance. No
opening shall be provided on main slab above for
this purpos. :
All the equipment, piping, pumps, air blowers and
electrical panel to be housed in the skid including
inlet, outlet, overflow, vent, moving ladders &
railing. The Plant shall be completed with a
central Electrical Power and Control panel fully
pre/site wired and with all power and control
cables to all pumps and equipment including all
instrumentation, level and other controls. The cost
will also include any consequential civil work
including making only foundations for the pumps,
blowers etc.

Sign and Stamp of EPIL 175 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Effluent from OT Scrubs, blood bank, labs etc.
Some solvent/ chemical waste originating typically
from hospital complex shall also be discharged
into the ETP. Design to take consideration of same.

Anticipated effluent parameters before treatment:


Daily average flow : 25 cubm/Day
● PH : 5.5 - 9.0
● BOD5 : 250 - 600 mg/l
● S. Solids : 200 - 650 Mg/l
● COD : 600 - 1200 mg/l

Desired Effluent discharge standard after teritary


treatment:
● PH : 7.0 - 8.5
● BOD5 : Less than 100 mg/l

● S. Solids : Less than 100 mg/l

● COD : Less than 250 mg/l

Effluent treatment plant shall include the


following items:
- Bar Screen Chamber
- Equalization tank/sump - RCC Construction
- Flocculation Tank - FRP Construction
- Tube Settler - RCC Construction
- Lime/alum/polyelectrolyte dosing
- Equity pumps/ Sludge recirculation pumps
- Piping, valves etc
( All RCC / brick work shall be in Civil Contractor's
scope)
Note: ETP contactor has to provide necessary
details regarding the above said works. All the
structural work shall be subject to the appoval of
structural consultants.

1.0 Shop Drawings.


Detailed GA drawing, flow diagram, equipment
list, power load requirement with design
calculations of all elements of the plant, electrical
and mechanical work to satisfy / supply adequacy
of design followed by submission of detailed
GOOD FOR CONSTRUCTION' architectural,
structural, construction, electrical, mechanical and
piping drawing for approval.

Contractor shall ensure submission of detailed GA


drawings (Plan & Section), P & I diagram,
schematic diagram for the above mentioned
components and additional components such as
inserts, puddle flanges, vent pipes etc. if so
required for the complete work.

Sign and Stamp of EPIL 176 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
2.0 Supply, installation, testing & commissioning of 2
Nos Stainless Steel Perforated Screen with
suitable lifting arrangement(size 400 x 500 mm
high approx). Required perforation of 10 mm and
8 mm respectively. - Jash / Ecologix / Hydrocon
Set 1 25000 25000

3.0 Supply, installation, testing & commissioning of


level controllers & indicators for automatic
operation of the complete system. - Pune Techtrol
/ Equivalent Lot 1 30000 30000

4.0 Providing, fixing, testing & commissioning of


Horizontal self priming, non-clog type effluent
handling pumps capable of handling solids upto 7-
10mm for incoming effluent from equalization
tank to Coagulation tanks and by pass the effluent
to municipal sewer in the time of maintenance .
The pump shall have CI casing & SS shaft & bronze
impeller, TEFC induction motor including pressure
gauge, all necessary piping (Inlet & outlet pipe),
suction & delivery header valves, level controller
with wiring to control the level of sump
automatically. etc. Receiving tanks shall be
completed with inlet, outlet, drain arrangement
(Pipe + Valve).

Equalized Effluent Water Lifting Pumps : DP /


Ebara / ITT
(2 Nos. - 1 W +1 S)
Flow rate (each pump) - 10 m3 / hr
Head - 8-10 Mtr
Solid Handling - 7- 10mm Set 1 55000 55000

5.0 Providing, fixing, testing & commissioning of non


clog type centrifugal semi open impeller type
pumps for sludge lifting 2 nos. (1W+1S) for the
disposal of sludge from settling tank to sludge
holding tank. The pumps shall have CI casing, CI
Impeller, CS shaft & sleeve with mechanical rotary
shaft seal connected by a flexible tier type
coupling to TEFC induction motor mounted on a
common channel base-plate with coupling guard,
150 mm dia pressure gauge with GM isolation
cock. Motor to be suitable for 415 + 10% volt, for 3
phase, 50 cycle AC supply including all necessary
piping, valves and other accessories complete as
required.

Sludge Transfer pump - Kirloskar / Matter and


Plat / Johnson
(2 Nos. - 1 W +1 S)
Flow Rate (each pump) - 10 m3 / hr
Head - 12 Mtr
Solid Handling - 7-10 mm
Type of Pump - Centrifugal Sludge transfer pump
No 1 115,000.00 115000

Sign and Stamp of EPIL 177 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
6.0 Supply, installation, testing & commissioning of
lime/alum/polyelectrolyte dosing system
consisting of one HDPE tank of 100 liters capacity
with a positive displacement diaphragm dosing
pump having variable flow rate of (0-6 LPH). The
motor shall be suitable for operation at 240V/
single phase/50 Hertz supply. The pump shall be
supplied complete with necessary polypropylene
piping, valves, strainers & injection fittings for
complete automatic dosing. - Asia LMI /
Toshiniwal / Nivo
Each 3 140,000.00 420000

7.0 Supplying, installing, testing and commissioning of


high speed Agitator of SS 304for floculation
complete with single phase motor for flash mixer. -
Hydrocon / Remi Set 1 55,000.00 55000

8.0 Supply, installation, testing & commissioning of


Flash mixer cum Flocculation tank in MSFRP
construction complete with puddle flange,
inlet/outlet connections etc - Hydrocon / Remi
Set 1 55,000.00 55000

9.0 Interconnectiong Pipelines, valves & fittings for


hospital waste water pretreatment. - Jindal / Tata
Job 1 55,000.00 55000

A SEWAGE TREATMENT PLANT AND ETP - 120 KLD

Design, Supplying, Installing, Testing &


Commissioning of Sewage Treatment Plant based
on SBR technology with Capacity 120 KLD & 25
KLD ETP . The plant proposed shall be with a
common pump room. The plant is proposed to be
installed in the basement accessible from the
pump room itself for future maintenance. No
opening shall be provided on main slab above for
this purpos. :
All the equipment, piping, pumps, air blowers and
electrical panel to be housed in the skid including
inlet, outlet, overflow, vent, moving ladders &
railing. The Plant shall be completed with a
central Electrical Power and Control panel fully
pre/site wired and with all power and control
cables to all pumps and equipment including all
instrumentation, level and other controls. The cost
will also include any consequential civil work
including making foundations for the pumps,
blowers etc.

1.0 Shop Drawings.

Sign and Stamp of EPIL 178 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Detailed GA drawing, flow diagram, equipment
list, power load requirement with design
calculations of all elements of the plant, electrical
and mechanical work to satisfy / supply adequacy
of design followed by submission of detailed
GOOD FOR CONSTRUCTION' architectural,
structural, construction, electrical, mechanical and
piping drawing for approval.

Contractor shall ensure submission of detailed GA


drawings (Plan & Section), P & I diagram,
schematic diagram for the above mentioned
components and additional components such as
inserts, puddle flanges, vent pipes etc. if so
required for the complete work.

Nature of Waste - Domestic Sewage/Laundry


waste/Kitchen waste Water/Filter Backwash/
Cleaning

Daily average flow - -120 cum/day

Anticipated effluent parameters before treatment:

PH - 7.5-8.5
BOD5 - 300 mg/ltr
COD - 500 mg/ltr.
SS - 300 mg/ltr.
Oil & Grease - 150 mg/ltr
Ecoli - >106 MPN
Ammonical Nitrogen - 50 ppm

Desired treated sewage standard after teritary


treatment:
PH - 6.5 – 8.0
BOD5 - Less than 10 Mg/L
COD - Less than 50 Mg/L
S. Solids - Less than 10 Mg/L
Hardness - Less than 5 ppm
Oil & Grease - < 10 Mg/L
Ecoli - < 10 3 MPN
Chlorine dosing - 0.5 ppm
Ammonical Nitrogen - 5 ppm

Sewage treatment plant shall include the following


items:
- Bar Screen Chamber
- Oil & Grease chamber
- Sewage equalization tank/sump
- SBR Reactor
- Chlorine Contact Tank
- Sludge Holding Tank
- Filtration through MGF & ACF
- Softener
UV
- UF for Flushing Water Demand Only
- Treated / Soft Water Tank
- Air Blowers, Pumps & equipment

Sign and Stamp of EPIL 179 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
- Centrifuge
- Piping, valves etc
- Electrical Panel & Cabling

Note: STP contactor has to provide necessary


details regarding the abovesaid works. All the
structural work shall be subject to the appoval of
structural consultants.

1.0 Supply & fixing of MS hot dip galvanized puddle


flanges in accordance to BS:10 table D as required
to be provided (in the structural slab and wall) of
various diameters. Puddle flanges shall be
provided for all the structural component of the
STP. The installation of the puddle flanges shall be
carried out by the Civil contractor in accordance
with Civil GA drawing (to be prepared by the STP
contractor) at the required levels & position;
under the supervision of the STP contractor.
Job 1 40000 40000

2.0 Supply & fixing of plastic manhole step/foot rest


(@ 300 mm c/C) with polypropelene compound
injection molded around 12 mm dia (Fe-415) steel
reinforcing bar. Provision of the foot rest is
envisaged in various tanks/ components of the STP
for the purpose of accessability. The installation of
the foot rest shall be done by the civil contractor
as per civil GA drawing.
Job 1 24550 24550

3.0 Supply & fixing of DI Medium duty rectangular


manhole cover with frame for the feasibility of
access in the tanks
Size 600x 900 Nos. 1 15000 15000
Size 600x 600 Nos. 1 10000 10000

4.0 Supply & fixing of vent pipes of 150 mm dia with


mosquito proof grating suitable for the ventilation
purpose of the various tanks. Nos. 1 15000 15000

5.0 Supply & fixing of DI grating for drain covers of


300X600mm sizing. Nos. 1 30000 30000

6.0 Providing and fixing manually cleaned Bar Screens,


to remove coarse and fine material in the waste
water made up of SS complete as required
including handle for lifting. Civil construction of
bar screen chamber by cilvil contractor as per
design submitted by STP vendor. - Hydrocon /
Jash / Ecologix
6.1 Coarse Screen (for 0.6 m/s inlet velocity and 0.9
m/s outlet velocity, with 12mm c/c spacing of
bars. Nos. 1 25000 25000
6.2 Fine Screen (for 0.6 m/s inlet velocity and 0.9 m/s
outlet velocity, with 6mm c/c spacing of bars.
Nos. 1 20000 20000

Sign and Stamp of EPIL 180 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
7.0 Supply, installation, testing & commissioning of
chlorine dosing system consisting of one HDPE
tank of 100 liters capacity with a positive
displacement diaphragm dosing pump having
variable flow rate of (0-6 LPH). The motor shall be
suitable for operation at 240V/ single phase/50
Hertz supply. The pump shall be supplied
complete with necessary polypropylene piping,
valves, strainers & injection fittings for complete
automatic dosing.
Set 1 30000 30000

8.0 Supply, installation, testing & commissioning of


level controllers & indicators for automatic
operation of the complete system. Job 1 45000 45000

9.0 Providing, fixing, testing & commissioning of fully


submersible, centrifugal non-clog type sewage
handling pumps capable of handling solids upto
35-40mm for raw sewage transfer from
equalization tank to SBR tanks and by pass the
sewage to municipal sewer in the time of
maintenance . The pump shall have CI casing &
impeller, SS shaft, TEFC induction motor including
pressure gauge, lifting arrangement for the pump,
all necessary piping (flexible pipe with coupling),
delivery header valves, tube type level indicator,
level controller with wiring to control the level of
sump automatically. etc. Receiving tanks shall be
completed with inlet, outlet, drain arrangement
(Pipe + Valve). Arrangement shall be provided in
the header for future connection of pumps. All
pipe sizes shall be desinged on the full capacity of
STP or provision of alternate arrangement to be
done as per vendor design.

Equalized Waste Water Transfer Pumps : DP /


Ebara / ITT
(2 Nos. - 1 W +1 S)
Flow rate (each) - 12 m3 / hr
Head - 10 Mtr
Solid Handling - 35- 40mm
Total No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 165,000.00 165000

Sign and Stamp of EPIL 181 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
10.0 Providing, fixing, testing & commissioning of
horizontal, centrifugal Sludge Recirculation Pump
for the disposal of sludge to settling tanks of ETP &
STP to sludge holding tank and Aeration tank. The
pumps shall have CI casing, Impeller, SS shaft &
sleeve with mechanical rotary shaft seal connected
by a flexible tier type coupling to TEFC induction
motor mounted on a common channel base-plate
with coupling guard with efficiency class IE3 or EFF-
1 whichever is more efficient, 150 mm dia
pressure gauge with GM isolation cock, suitable
vibration eliminator pads of approved design.
Motor to be suitable for 415 + 10% volt, for 3
phase, 50 cycle AC supply including all necessary
piping, valves and other accessories complete as
required.

Sludge Transfer / Recircualation pumps - Kirloskar


/ M&P / Johnson
(2 Nos. -1 W + 1S )
Flow Rate (each) - 4 m3 / hr
Head - 10 Mtr
Solid Handling - 10-12 mm
Type of Pump - Centrifugal Sludge recirculation
pump
Total No. of Pumps (2 Nos. – 1 W + 1 S)
No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 115,000.00 115000

11.0 Air diffusion system shall include the following:

11.1 Twin type rotary air blowers casing - CI, shaft-


Alloy Steel, capable of delivering 260 cum/hr
(each) of free air at 0.55 kg/sq.cm driven through
“V” belt or directly coupled through flexible
coupling to a TEFC motor of suitable HP Suitable
for 415 ± 10% volts, 3 phase, 50 cycles A/C
supply. Arrangement shall be provided in the
header for future connection of blowers. All pipe
sizes shall be desinged on the full capacity of STP
or provision of alternate arrangement to be done
as per vendor design for future connection. -
Evereset / Beta / Kay / Usha

Total no. of Blowers - 2 Nos.


No. of Blowers (2 Nos. – 1 W + 1 S) Set 1 145,000.00 145000

11.2 Air piping shall comprise of pipes droppers/


laterals with SS 304 Header complete with all
fittings such as tees, crosses, plugs, sockets,
elbows, reducers, supports & clamps etc cutting
chases & making good. Contactor to submit
detailed P & I indicating their proposal for
complete system. - Jindal / Tata Job 1 135,000.00 135000

Sign and Stamp of EPIL 182 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
11.3 Non-clog type air dispersion system capable of
handling 3-5 cfm of air with oxygen transfer
efficiency of 3-4% per/meter water depth. Air
dispersion grid shall be assembled in modular
form so that they can be replaced / repaired
easily from platform at the top. (Imported fine
bubble membrane diffusers) - Rehau / OTT / EDI
Job 1 145,000.00 145000
Note :
Air dispersion system shall be provided for Sewage
Sumps for ETP & STP, Settling tanks & SBR Tanks.

12.0 Providing and fixing all interconnecting piping (as


described below) and isolation control valves for
making the system complete. The piping material
shall be GI otherwise 10 bar pressure rating. -
Jindal / Tata
a) All piping submerged in sewage waste/pumping
sewage waste shall be HDPE.
b) All piping for treatment plant & post treatment
plant shall also be in GI (medium duty).
Job 1 195,000.00 195000

13.0 Supplying, installing, testing & commissioning of


Submersible Jet Areator in Eqalization Tank 2 Nos. -
Wastech Enviro / ABS / Sulzer

Capacity : 150 M3/Hr


MOC :CI
No. 1 115,000.00 115000

14 Supply, installation, testing & commissioning of


motorized Moving Decanter to suit SBR tank with
MOC SS-304 with scum guard and connected with
ultrasonic level transmitter & ultrasonic level
element for automatic control etc. complete as
required. Make of Decanter : Premier Tech /
C-Tech / Wastech - Wastech Envrio
Solution / Hydrocon
No 1 675,000.00 675,000.00

Sign and Stamp of EPIL 183 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
15.0
Supplying, installation & commissioning of
centrifuge non-submersible type pumps, TEFC
induction motor with efficiency class IE3 or EFF-1
whichever is more efficient, to feed semi tested
water to secondary treatment process through
sand pressure filter, activated carbon filter and
softener (Dry run protection). 1 no pressure gauge
4”dial with valve tee and fittings. 2 Nos cast iron
lever operated slim seal type butterfly valves of CI
body and spheroidal graphite iron disc with nitrile
rubber seal tested to 10 Kg /sq cm conforming to
BS 5155/MF6 standards and including a set of GI
flanges as BS -10 table including bolts, GI washers,
neoprene rubber gaskets, complete etc.
Arrangement shall be provided in the header for
future connection of pumps. All pipe sizes shall be
desinged on the full capacity of STP or provision of
alternate arrangement to be done as per vendor
design to meet the future requirement.

15.1 Filter Feed Pumps: - Kirloskar / M&P / Johnson

Capacity : 10 Cum/hr.
Head : 30 - 35 Mtrs
Type of Pump : Horizonal Centrifugal pump
Total No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 135,000.00 135000

16.0 Providing, fixing, testing and commissioning of


horizontal centrifugal treated/Soft water transfer
pumps. The pumps shall be made of C.I. casing, CI
impeller, SS shaft & sleeve. Mechanical seal
connected by to a TEFC induction motor mounted
on a common channel base-plate with efficiency
class IE3 or EFF-1 whichever is more efficient with
coupling guard 150 mm dia pressure gauge with
GM isolation cock, suitable vibration eliminator,
pads of approved design. Motor to be suitable for
400/440V, 3 phase 50 cycles AC power supply,
including all necessary piping, suction and delivery
header, individual suction and delivery of pump,
valves, NRV, pressure gauge and other accessories
and concrete foundation complete as required.

16.1 Flushing/Soft Water Transfer Pump - DP / Ebara /


ITT
Capacity : 5 LPS
Head : 70 Mtrs
Type of Pump : Horizonal Centrifugal pump
No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 210,000.00 210000

16.2 Irrigation pumps: - DP / Ebara / ITT


Capacity : 5 LPS
Head : 50 Mtrs
Type of Pump : Horizonal Centrifugal pump
No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 180,000.00 180000

Sign and Stamp of EPIL 184 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.

18.0 Supply, installation, testing & commissioning of


single stage single entry drainage pumps
connected to TEFC submersible motor for 415 +
10% volts, 3 phase, 50 cycles A.C. power supply
with mechanical seal, pump connector unit with
rubber diaphragm and bend, vertical. discharge
pipe, in built level controller with operational
moded as one pump working at low level, both
pumps at high level with a hooter alarm and cut
off at dry level as determined. The pump shall be
provided with a lifting devise of pull chain/guide
rail & minimum 80 mm dia (G.I. heavy class) rising
main of 5m length including interconnecting
piping, valves (Ball Valve / Butterfly), Non return
valves (GM/CI) 15 m cable etc. as per requirement
complete in all respects. The pump panel with all
automation to be included in the scope of works.

(Pumps to be suitable to handle solids upto 10-12


mm size with CI body, CI impeller, S.S. shaft with
15 mtrs cable, double mechanical seal).
Cost shall be inclusive of GI piping for lifting water
from sump to outside.
Provision of guide ropes to guide submersible
pump from upper level to operational level in
sump basin with channels / angle section of MSEP
shall be made by the STP contractor.
Plant room Drainage Pump: - DP / Ebara / ITT
Flow rate = 25 M3/Hr
Head = 10-12 Mts
Solid Handling = 10-12mm
1 Set = Two(2) Nos.Pumps (1 W + 1 SB) Set 1 165,000.00 165000

19.0 Multigrade Pressure Sand Filter:

Sign and Stamp of EPIL 185 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Supply, installation, testing and commissioning of
vertical self supporting Multigrade pressure
Pressure Sand Filter fabricated out of 8mm thick
M.S. plate with 10mm dished ends MS sheet as
per IS : 2825, pressure gauges at inlet & outlet,
sample cock, air vent valve, PVC/GI face piping,
distribution pipe with diffuser on top, manholes
and side holes with cover, under drains,
supporting legs flanged piping, CI butterfly valves
and all accessories, with initial charge of filter
media, painting inside with food grade epoxy paint
and outside with two coat of red oxide primer and
two or more coat of synthetic enamel paint
complete with bypass arrangement including
piping and valves of required no. and size. Filter
shall be supplied with initial charge of Filter media
like special graded sand with supporting media like
silex, gravel etc. The vender shall submit the
certificate of having tested the same. The filter
shall complete with pressure gauge at inlet &
outlet, sample cock, GI/PVC face
piping/interconnected piping, automatic timer
based multiport valve (control valve) and all
necessary accessories. Arrangement shall be
Grain size of media =0.6- 1.2 mm
Flow rate per filter= 24000 lph
Filtration rate=18,000 lph / m 2
Working presssure= 3.5 kg / cm2
Test Pressure= 7 kg / cm2
Filter dia approximate: 1200 mm
Backwash duration: once in 16 hours for 20 min
Valve = Butterfly Valve Nos. 1 210,000.00 210000
PipeLine = GI / MS C Class

20.0 Activated Carbon Filter:

Sign and Stamp of EPIL 186 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Supply, installation, testing and commissioning of
vertical self supporting Activated Carbon Filter
fabricated out of 8mm thick M.S. plate with
10mm dished ends MS sheet as per IS : 2825,
pressure gauges at inlet & outlet, sample cock, air
vent valve, PVC/GI face piping, distribution pipe
with diffuser on top, manholes and side holes
with cover, under drains, supporting legs flanged
piping, CI butterfly valves and all accessories, with
initial charge of filter media, painting inside with
food grade epoxy paint and outside with two coat
of red oxide primer and two or more coat of
synthetic enamel paint complete with bypass
arrangement including piping and valves of
required no. and size. Filter shall be supplied with
initial charge of media like Activated Carbon
Media of 900 iodine value, with supporting media
like silex, gravel etc. The vender shall submit the
certificate of having tested the same. The filter
shall complete with pressure gauge at inlet &
outlet, sample cock, GI/PVC face
piping/interconnected piping, automatic timer
based multiport valve (control valve) and all
necessary accessories. Arrangement shall be
provided in the header for future connection of
Flow rate per filter= 24000 lph
Filtration rate=18,000 lph / m 2
Working presssure= 3.5 kg / cm2
Test Pressure= 7 kg / cm2
Filter dia approximate: 1200 mm Nos. 1 205,000.00 205000
Valve = Butterfly Valve
PipeLine = GI / MS C Class

22.0 Hypo Dosing system:


Supplying, installation & commissioning of on line
automatic electronic sodium hypo chlorine dosing
unit with automatically operated dosing pump . -
Asia LMI / Toshcon / Prominent
The free chlorine in the filtered water shall not be
less than 0.5ppm.
Type: Diaphragm
Capacity= 10 LPH
Min Actuating Pressure= 0.3 bar
Max Working pressure= 0.5 bar
Maximum Suction Pressure=1.5m
Motor = 0.5 HP
PP Storage Tank= 500 ltrs
No. of Pumps (2 Nos. – 1 W + 1 S) Set 1 45000 45000

Sign and Stamp of EPIL 187 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
23.0 Providing & fixing of sludge handling arrangement
(Centrifuge) solid bowl type of required size for
upto 100 deg. celsius temperature to be placed on
a platform above the ground with arrangement for
sludge feed to centrifuge from centrifugal semi
open impeller sludge pumps at a distance as
required with watering and flushing arrangement.
Effluent from Centrifuge to be connected to
equilization tank and the entire equipment
mounted on MS base frame bolted to cement
concrete foundation complete with testing &
commissioning as required and as specify. -
Hydrocon / Penwalt / Humboldth
Set 1 50000 50000

24.0 Fabrication and supply of Sludge Trolley in


Galvanized Steel with min. Dimensions of 950 mm
x 600mm x 500 mm depth (min. sheet thickness
2.0 mm) with handle and wheel barrow for
transport of sludge complete as per requirements
and as specified. - Fabricated Nos. 1 100000 100000

25.0 Supply, installing, testing & commissioning of


Ultravoilet dis-infection unit. The unit shall have
over 99.9 % colifirm from inlet to outlet. The dis-
infection chamber shall be constructed of SS 316L
on all weted parts. The UV lamp shall be of low
pressure mercury vapour type with hard glass
enclosure, the sockets shall be water tight &
vibration resistant. The lamp life shall be rated for
9000 hours. The access to the UV lamp shall be
without the need to interrupt the ballast circuit. -
Wastech / Alfa - Mumbai

The unit shall be designed for the transmission for


the 65% to 75% of the stp water complete with,
lamp out alert circuit & UV radiometer with 4 – 20
mA output.
The UV unit shall have with reactor, cabinet
housing, cabinet cooling, treatment chamber,
electrical panel, temperature safety control,
lampout alert, UV radiometer along with UV
monitoring system and UV monitoring readout
panel. The UV Dosage should be > 60,000 uW –
Sec /sq.cm. The lamps should be selected based
upon the flow requirement of respective unit.
Automatic cleaning arrangement for the quartz
glass with the automatic wiper

Providing, installing, testing and commissioning of


UV system for treatment of tertiary treated water
of 15 m3/hr. Set 1 240,000.00 240000

26.0
Variable Pore Microfiltration System for Flushing

Sign and Stamp of EPIL 188 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.

Supplying, installing, testing and commissioning of


VPMF System piping and Valves with all the
1 required accessories & chemical cleaning system,
complete in all respects. - System Supplier -
Wastech / Brisanzia / Hydrocon

VPMF Module (Fully Backwashable top to bottom


filtration with 1 Micron Rating) including SS 304,
1.1 Pneumatic Valve, PLC Electrical Panel, flow meter,
compressor and all other accessories making the
system complete
Flow rate : 5 cum/hr Output
Inlet TSS :- 30-50 mg/lt
Membrane MOC - Polymer - Fiber and SS 316
Housing
Membrane Type :- Auto Backwashable
Microfiltration
No. of VPMF Module - 3 Number
Make of System - Wastech / Hydrocon / Brisanzia Set 1
550,000.00 550000

1.2 VPMF Feed Pump


Capacity 12 M3/hr each (1 W + 1 SB)
Head 20-25 Mts
RPM 2900
Make - Grundfos / Equivalent Set 1 135,000.00 135000

Supplying, installing, testing, commissioning of


centrifugal Backwash pumps with Complete SS -
304 with motor, pressure gauge with isolation
1.4
cock, Isolation valve, NRV on delivery line.
Isolation valve, strainer at suction. The pump shall
be suitable for 415±10% volts 3 phase AC supply .
Capacity : - 8 m³/h
Head : - 18- 20 m
No. of Pumps: 2 Nos. (1W + 1S)
Note-CIP pumps can be common with item no.c
Make - Grudfos / Equivalent Set 1 12,000.00 12000

Supplying, Installation, testing and commissioning


of PAC dosing system compromising of Sintex Tank
1.5 Set 1
with inlet/ outlet connection, piping and valves
alongwith metering pump of 6 LPH for dosing.
35,000.00 35000
Make - Asia LMI

Supply installation commissioning of PLC control


panel with all automation required like Pneumatic
valves, piping in UPVC PLC and other required
1.6 Set 1
accessories.
Make PLC - Siemens, Pneumatic Valve - Danfos,
UPVC Pipe - Astral, Compressor - Elgi 225,000.00 225000

Sign and Stamp of EPIL 189 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Supply, installation & commissioning of HDPE
1.8 backwash tank of 1000 Litre capacity including Set 1
required level controller 15,000.00 15000

27.0
Providing, installing, testing and commissioning of
Water Flow meter Electro magnetic type suitable
for 0-25000 LPH - suitable sizes /dia ( Inlet To STP
& Treated water Line)
Nos. 2 15,000.00 30000

28.0
Providing, installing, testing and commissioning of
Online digital type pH meter.
Nos. 1 50,000.00 50000

29.0 Bypass arrangement (During maintenance of STP)


including earth work in excavation/backfilling in all
types 80 NB of soil upto 1.5m depth and piping
from Equalization tank to municipal sewer
including all fittings, isolation
valves/NRV/Accessories and protection of under
ground pipes with anticorresive tapes etc required
to complete the system. (Approx. length
considered is 50 mtr.)
Job 1 50,000.00 50000

Note:
All technical liasioning, inputs, documents,
meeting with Pollution Control Board for
“Consent to operate” including arranging raw
sewage for testing and commissioning shall be in
the scope of Contractor. Contractor shall include
the cost of all chemicals consumed during testing
& commissioning and the cost of such items of
works which are not explicitly mentioned above
but are mandatory to have pollution board
approval. However responsibility of obtaining
license for consent to operate shall be in other
agency's scope.

C. ELECTRICAL INSTALLATION

Note Electrical Control Panel - Vee4 tech / Tricolite /


Adlec / Advance panel / Sudhir Panel
The rates for the control panels apart from the
switches and instruments shall also include the
following :
1 Supporting rigid steel frame work.
2 Cubicle type, 2mm thick CRCA sheet steel enclosed

3 Complete with interconnections and distribution


bus bars
4 Proper bonding to earth
5 Painting / Lettering on switches and control
panels, the location they serve, providing on each
panels its circuit diagram
6 All Panels shall have provision for the following :

a) Padlocking of panel doors

Sign and Stamp of EPIL 190 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
b) Padlocking of MCCB's handles in 'OFF' position

7 Providing cable clamps / supports within panels


cable alley
8 TPN MCCB shall means 3 Pole MCCB with separate
neutral link of adequate size.
9 All MCB's shall be minimum 10 kA breaking
capacity
10 The breaking capacity of MCCB's are mentioned
panel wise. All MCCB's shall be provided with
static release and setting plugs.
11 All motor feeders MCCB's shall be of motor duty

12 Rubber mats shall be provided in front of all


panels and shall be provided at th back where they
are accessible from the back as per IS 5424 - 1969

13 Control Panel shall be painted with light grey paint


shade No. 631 of IS - 5
14 Degree of protection for following type of
distribution panel enclosure shall be as per IS
13947 - 1993
a) IP 42 for indoor panels
b) IP 55 for outdoor panels
15 All MCCB shall be provided with operating
mechanism for door interlock.
16 Minimum bus bar cross section shall be required
for following fault level.
a) 50 x 6 mm Aluminium for 20 kA. 1 Sec
17 Current density of Aluminium shall be 1 Sq. mm
for 1 Amp fire rated current of bus bars.
18 GI flat earth bus shall be provided through out the
length of each panel
19 MCC for submersible drainage pumps and
tubewells to be supplied by the pumps
manufacturers for complete compatibility
20 Providing, installing, testing & commissioning of
motor control centres fabricated from 16 gauges
MS sheet with powder coated finish. The Control
Panels should be comparable with HP of the motor
as specified

ELECTRICAL PANEL

For filter feed pump, equalization pumps, sludge


recirculation pumps, Irrigation pumps, transfer
pumps, slurry pumps etc in plant room.

Incomer
200A TP+N MCCB (35KA)

Metering
(0-500) volts digital voltmeter with selector switch
protected by 2A control MCB's
(0-200A) Digital ammeter with Selector Switch and
suitable ratio, CL-1, 10VA CT's
Phase indicating lamps with toggle switches

Bus Bar:

Sign and Stamp of EPIL 191 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
300A TPN aluminium , colour coded bus bars
suitable for 415V, 50Hz. (after deration)

Outgoing:
1 No. 63A TPN MCCB for Hydropneumatic system

4 Nos. 40A TPN MCCB for Filter Feed Pumps


4 Nos. 40A TPN MCCB for Sewage Transfer Pumps

2 Nos. 32A TPN MCCB for Sewage Transfer Pumps


(ETP)
2 Nos. 40A TPN MCCB for Sludge Recirculation
Pumps
2 Nos. 40A TPN MCCB for Irrigation lifting Pumps

1 No. 40A TPN MCCB for Sump Pumps


5 Nos. 40A TPN MCB for Slurry Pumps/air blower

2 Nos. 63A TPN MCCB for Soft water Transfer


Pumps
2 Nos. 40A TPN MCB for Softner feed Pumps
5 Nos. 32A TPN MCB for dosing pumps
1 Nos. 63A TPN MCCB for UF System
1 Nos. 40A TPN MCCB for UV System
1 Nos. 40A TPN MCCB for Centrifuge
2 Nos. 63A TPN MCCB spare
1 No. 32A TPN MCB spare
1 No. 40A TPN MCB spare

One (1) Nos. 15 HP motor with single phasing


prevention arrangement, O/L relays, ammeters
with CTs, ON/OFF / Trip indication lamps and push
buttons, potential free contacts for remote / local
operations, indication, interlocking and Auto
Manual Selector Switch as required for
Hydropneumatic system
Four (4) Nos. DOL starter for 5 HP motor with
single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Filter Feed pumps.

Two (2) Nos. DOL starter for 1 HP motor with


single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for waste water transfer pumps (ETP)

Sign and Stamp of EPIL 192 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Four (4) Nos. DOL starter for 5 HP motor with
single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for waste water transfer pumps (STP)

Two (2) Nos. DOL starter for 5 HP motor with


single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Sludge Recirculation Pumps

Two (2) Nos. DOL starter for 7.5 HP motor with


single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Soft water transfer Pumps

Two (2) Nos. DOL starter for 5 HP motor with


single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Softner Feed Pumps

Two (2) Nos. DOL starter for 5 HP motor with


single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Irrigation lifting Pumps

One (1) Nos. 3 HP motor with single phasing


prevention arrangement, O/L relays, ammeters
with CTs, ON/OFF / Trip indication lamps and push
buttons, potential free contacts for remote / local
operations, indication, interlocking and Auto
Manual Selector Switch as required for Sump
Pumps
Two (2) Nos. DOL starter for 3 HP motor with
single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Slurry Pumps

Sign and Stamp of EPIL 193 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
Four (4) Nos. DOL starter for 3 HP motor with
single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Air Blower
Five (5) Nos. DOL starter for 0.5 HP motor with
single phasing prevention arrangement, O/L
relays, ammeters with CTs, ON/OFF / Trip
indication lamps and push buttons, potential free
contacts for remote / local operations, indication,
interlocking and Auto Manual Selector Switch as
required for Dosing Pumps.
Panel shall be designed on the actual HP as per
model selection of pumps and makes.
Notes :
All MCCBs / MCBs shall be of 15 KA breaking
capacity and suitable for motor duty application.

All motor starters shall be provided with


Automatic level controller
DOL starters shall be used for mototrs below 10HP
and Star-Delta Starters for other motors .
Provision shall be made for providing potential
free contacts to all pumps starters
All motor starters shall be provided with
Automatic level controller.
DOL starters shall be used for mototrs below 10HP
and Star-Delta Starters for other motors.
Provision shall be made for providing potential
free contacts to all pumps starters
Provision for auto starters for all motors with level
controllers shall be made in the panel.
Provision for dry run protection shall be made in
the panel.
MCC for STP as described above
All Control system to make the STP fully
automatic. The operation of the pumps shall be
controlled by the level controller. Set 1 280,000.00 280,000.00
The panel should have sufficient no. of potential
free contacts for monitoring purposes.

PLC PANEL

1 Supply, installation, testing & commissioning of


the PLC based control panel with interlocking
arrangement with supply pumps,suction pumps,
modulating or shut-off valves including necessary
wiring, magnetic switches & sensors complete to
make the system functional with following
interlocking

i Construction: Compartmentalized Type Skid


Mounted, MCC Cum PLC Control panel will be free
standing; vertical, fabricated from CRCA steel
sheet 14/16 G conforming to degree of protection
IP-52 or better. Cable entry will be from bottom.
Colour shade - RAL 7032

Sign and Stamp of EPIL 194 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.
ii System Voltage: 380 to 410 Volts & 50HZ ( 415 V
±10% , AC, 50 HZ ±5% for India ). Surge protection
to be provided at every applicable point.

iii PLC: The Programmable Logic Controller [PLC]


shall consist of a PLC hardware, with 16k (min)
program memory shall be protected by a backup
battery with further memory protection from an
EEPROM.

iv HMI: 5.5 Inch Colour Touch screen HMI, will be


mounted on A Man-Machine Interface Terminal
(MMI) shall be mounted on the front of the main
control panel for control of the activated sludge
plant. It will provide a display of the process
parameters and equipment status. The display will
have an associated keypad. The system will allow
operator changes to set points and control of
equipment. The terminal shall include an alarm
annunciation with a dedicated alarm page and
allow acknowledgment of alarms.
Make:Siemens / ABB
Set 1 300,000.00 300000

TOTAL 5,976,550.00

SECTION - XI
BORE WELL INSTALLATIONS (As per D.S.R.2016)

1.0 23.1 Boring/drilling bore well of required dia for casing/


strainer pipe, by suitable method prescribed in IS:
2800 (part I), including collecting samples from
different strata, preparing and submitting strata
chart/ bore log, including hire & running charges
of all equipments, tools, plants & machineries
required for the job, all complete as per direction
of Engineer -in-charge, upto 90 metre depth below
ground level.

23.1.1 All types of soil


23.1.1. 350 mm dia metre 40
2 405.45 16218.00
23.1.2 Rocky strata including Boulders
23.1.2. 350 mm dia
2 metre 15 895.25 13428.75

2 23.15 Providing and fixing Ball plug/bottom plug of


required dia to the bottom of pipe assembly of
tubewell as per IS:2800 (Part I)
23.15. 150 mm dia
2 metre 2 230.75 461.50

3 23.8 `Gravel packing in tubewell construction in


accordance with IS: 4097, including providing
gravel fine/ medium/ coarse, in required grading &
sizes as per actual requirement, all complete as
per direction of Engineer-in-charge.
cum 9 1175.6 10580.40

Sign and Stamp of EPIL 195 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.

4 23.10 Supplying, assembling, lowering and fixing in


vertical position in bore well, ERW (Electric
Resistance Welded) FE 410 mild steel screwed and
socketed/ plain ended casing pipes of required dia,
conforming to IS: 4270, of reputed & approved
make, including painted with outside surface with
two coats of anticorrosive paint of approved brand
and manufacture, including required hire & labour
charges, fittings & accessories, all complete, for all
depths, as per direction of Engineer-in-charge.

23.10. 150 mm nominal size dia having minimum wall


2 thickness 5.00 mm. metre 40 1,210.60 48424.00

5 23.11 Supplying, assembling, lowering and fixing in


vertical position in bore well, ERW (Electric
Resistance Welded) FE 410 plain slotted (having
slot of size 1.6/3.2 mm) mild steel threaded and
socketed / plain bevel ended pipe (type A) of
required dia, conforming to IS:8110, of reputed
and approved make, having wall thickness not less
than 5.40 mm, including painted with outside
surface with two coats of anticorrosive bitumestic
paint of approved brand and manufacture,
including hire & labour charges, fittings &
accessories, all complete, for all depths, as per
direction of Engineer -in-charge.

23.11. 150 mm nominal size dia


2 metre 8 1,291.50 10332.00

6 Development of tube well in accordance with IS :


2800 (part I) and IS: 11189, to establish maximum
rate of usable water yield without sand content
(beyond permissible limit), with required capacity
air compressor, running the compressor for
required time till well is fully developed,
measuring yield of well by "V" notch method or
any other approved method, measuring static level
& draw down etc. by step draw down method,
collecting water samples & getting tested in
approved laboratory, i/c disinfection of tubewell,
all complete, including hire & labour charges of air
compressor, tools & accessories etc., all as per
requirement and direction of Engineer-in-charge.

23.12 hour 12 542.2 6506.40

7 Providing and Fixing MS Clamp of required dia to


the top of casing housing pipe of tubewell as per
IS:2800 (Part I), including necessary bolts & nuts of
23.14 required size complete.
23.14. 150 mm dia
2 each 1 1017.7 1017.70
COST OF 1 BORE WELL 106,968.75

COST OF 3.0 BORE WELL 320,906.25

Sign and Stamp of EPIL 196 Sign and Stamp of Bidder


S. NO. (DSR-
2016) DESCRIPTION UNIT QTY. RATE AMOUNT
No.

SECTION- XI BORE WELL INSTALLATIONS (NON-SCHEDULED ITEMS)

8 Supplying & Installation of suitable Hp submersible


pump B.S or K.S.B or equivalent make with finolex
cable 1x3x2.5 squmm(upto 75mtr) withflexible
conduit 25mm dia, electrical out door pannel with
required electrical fitting such as MCB of 0-25Amp
(Havell or Indocopp or MDS make), Volt & Ampere
meter (AE make), single phase preventer (Minilac
or VSP -1 make) starter (L&T or BCH make) etc of
approved make, 40mm HDPE Pipe (25 mtr) and all
accessories complete as per requirement of site.

MR Each 3 123,000.00 369,000.00


NOTES
a) Contractor shall include the rate of electrical
control panels complete with all accessories
&controls, all Electrical/Mechanical items as
required to operate the system automatic/manual.

b) Contractor to select suitable HP of pumps .


c) Level Controller with sufficient nos. of low / high
level alarms, contacts with electrodes and control
wiring for the automatic operation of water supply
pumps, Submersible Sump Pumps, to achieve the
functional requirement shall be provided. Control
wiring between these pumps and water tanks shall
be provided.Domestic water pumps must start at
low water level in overhead domestic water tank
& stop at high level in that water tank. Dry running
protection shall be provided for all the
pumps.Sequencing shall be provided for each set
of pumps.

total 28,302,872.62

Sign and Stamp of EPIL 197 Sign and Stamp of Bidder


Name of Work: Construction of 100 Bedded Hospital for ESIC at Bhilai
BOQ for Lift
S. NO. Non DSR
DESCRIPTION UNIT QTY. RATE AMOUNT
Providing , designing , installing Lift of capacity 26
1 MR No 4 3200000 12800000
persons (1768Kg) , macine room type
The Broad specification/requirment are as follows
Basik data
Capacity- 1768 kg
Control- Selective collective
Drive type- Variable Voltage Variable Frequency
Elevator type- Bed/ Hospital elevator
Grouping- Single
No. of stops- 5
Rated Load- 1768 kg
Rated speed - 1m/s
Car in side Height -2200mm
Door Height- 2000mm
Door type- power with door lock
Head room -4500mm
pit height- 1800mm
Car depth-2400mm
Car width- 1600mm
Door width- 1100mm
Car Indicator- Dot Matrix
Intercom Type- 2- station Intercom
Car Finish- Stainless steel haireline
Landing door - Stainless steel haireline with two
speed power door and railing- standerd
The lift should be with - Automatic Rescue device ,
Emergency light invertor, fire man Drive , Lift
announcement system , load weighing device ,
Regeneration
Required device
capacity etc and mechanical devices
motor
should be of good quality
Total 12800000

Sign and Stamp of EPIL 198 Sign and Stamp of Bidder